1.
Magn Reson Med ; 92(5): 2051-2064, 2024 Nov.
Article in English | MEDLINE | ID: mdl-39004838

ABSTRACT

PURPOSE: For reliable DCE MRI parameter estimation, k-space undersampling is essential to meet resolution, coverage, and signal-to-noise requirements. Pseudo-spiral (PS) sampling achieves this by sampling k-space on a Cartesian grid following a spiral trajectory. The goal was to optimize PS k-space sampling patterns for abdomin al DCE MRI. METHODS: The optimal PS k-space sampling pattern was determined using an anthropomorphic digital phantom. Contrast agent inflow was simulated in the liver, spleen, pancreas, and pancreatic ductal adenocarcinoma (PDAC). A total of 704 variable sampling and reconstruction approaches were created using three algorithms using different parametrizations to control sampling density, halfscan and compressed sensing regularization. The sampling patterns were evaluated based on image quality scores and the accuracy and precision of the DCE pharmacokinetic parameters. The best and worst strategies were assessed in vivo in five healthy volunteers without contrast agent administration. The best strategy was tested in a DCE scan of a PDAC patient. RESULTS: The best PS reconstruction was found to be PS-diffuse based, with quadratic distribution of readouts on a spiral, without random shuffling, halfscan factor of 0.8, and total variation regularization of 0.05 in the spatial and temporal domains. The best scoring strategy showed sharper images with less prominent artifacts in healthy volunteers compared to the worst strategy. Our suggested DCE sampling strategy also showed high quality DCE images in the PDAC patient. CONCLUSION: Using an anthropomorphic digital phantom, we identified an optimal PS sampling strategy for abdominal DCE MRI, and demonstrated feasibility in a PDAC patient.


Subject(s)
Abdomen , Algorithms , Contrast Media , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Pancreatic Neoplasms , Phantoms, Imaging , Humans , Magnetic Resonance Imaging/methods , Contrast Media/chemistry , Abdomen/diagnostic imaging , Image Processing, Computer-Assisted/methods , Pancreatic Neoplasms/diagnostic imaging , Pancreas/diagnostic imaging , Liver/diagnostic imaging , Signal-To-Noise Ratio , Carcinoma, Pancreatic Ductal/diagnostic imaging , Adult , Male , Spleen/diagnostic imaging , Healthy Volunteers , Female , Image Interpretation, Computer-Assisted/methods , Reproducibility of Results
2.
Quant Imaging Med Surg ; 14(5): 3447-3460, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38720850

ABSTRACT

Background: Magnetic resonance elastography (MRE) is a non-invasive method to measure the viscoelastic properties of tissue and has been applied in multiple abdominal organs. However, abdominal MRE suffers from detrimental breathing motion causing misalignment of structures between repeated acquisitions for different MRE dimensions (e.g., motion encoding directions and wave phase offsets). This study investigated motion correction strategies to resolve all breathing motion on sagittal free-breathing MRE acquisitions in a phantom, in healthy volunteers and showed feasibility in patients. Methods: First, in silico experiments were performed on a static phantom dataset with simulated motion. Second, eight healthy volunteers underwent two sagittal MRE acquisitions in the pancreas and right kidney. The multi-frequency free-breathing spin-echo echo-planar-imaging (SE-EPI) MRE consisted of four frequencies (30, 40, 50, 60 Hz), eight wave-phase offsets, with 3 mm3 isotropic voxel size. Following data re-sorting in different number of motion states (4 till 12) based on respiratory waveform signal, three intensity-based registration methods (monomodal, multimodal, and phase correlation) and non-rigid local registration were compared. A ranking method was used to determine the best registration method, based on seven signal-to-noise and image quality measures. Repeatability was assessed for no motion correction (Original) and the best performing method (Best) using Bland-Altman analysis. Lastly, the best motion correction method was compared to no motion correction on patient MRE data [pancreatic ductal adenocarcinoma (PDAC, n=5) and metabolic dysfunction-associated steatotic liver disease (MASLD) (n=1)]. Results: In silico experiments showed a deviation of shear wave speed (SWS) with simulated motion to the ground truth, which was (partially) resolved using motion correction. In healthy volunteers ranking resulted in the best motion correction method of monomodal registration using nine motion states, while no motion correction was ranked last. Limits of agreement were (-0.18, 0.14), and (-0.25, 0.18) m/s for Best and Original, respectively. Using motion correction in patients resulted in a significant increase in SWS in the pancreas (Original: 1.39±0.10 and Best: 1.50±0.17 m/s). After motion correction PDAC had a mean SWS of 1.56±0.27 m/s (Original: 1.42±0.25 m/s). The fibrotic liver mean SWS was 2.07±0.20 m/s (Original: 2.12±0.18 m/s). Conclusions: Motion correction in sagittal free-breathing abdominal MRE results in improved data quality, inversion precision, repeatability, and is feasible in patients.

3.
JHEP Rep ; 6(3): 100998, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38379586

ABSTRACT

Background & Aims: Individuals with obesity may develop intrapancreatic fat deposition (IPFD) and fatty pancreas disease (FPD). Whether this causes inflammation and fibrosis and leads to pancreatic dysfunction is less established than for liver damage in metabolic dysfunction-associated steatotic liver disease (MASLD). Moreover, the interrelations of FPD and MASLD are poorly understood. Therefore, we aimed to assess IPFD and fibro-inflammation in relation to pancreatic function and liver disease severity in individuals with MASLD. Methods: Seventy-six participants from the Amsterdam MASLD-MASH cohort (ANCHOR) study underwent liver biopsy and multiparametric MRI of the liver and pancreas, consisting of proton-density fat fraction sequences, T1 mapping and intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI). Results: The prevalence of FPD was 37.3%. There was a clear correlation between pancreatic T1 relaxation time, which indicates fibro-inflammation, and parameters of glycemic dysregulation, namely HbA1c (R = 0.59; p <0.001), fasting glucose (R = 0.51; p <0.001) and the presence of type 2 diabetes (mean 802.0 ms vs. 733.6 ms; p <0.05). In contrast, there was no relation between IPFD and hepatic fat content (R = 0.03; p = 0.80). Pancreatic IVIM diffusion (IVIM-D) was lower in advanced liver fibrosis (p <0.05) and pancreatic perfusion (IVIM-f), reflecting vessel density, inversely correlated to histological MASLD activity (p <0.05). Conclusions: Consistent relations exist between pancreatic fibro-inflammation on MRI and endocrine function in individuals with MASLD. However, despite shared dysmetabolic drivers, our study suggests IPFD is a separate pathophysiological process from MASLD. Impact and implications: Metabolic dysfunction-associated steatotic liver disease (MASLD) is the most common chronic liver disease worldwide and 68% of people with type 2 diabetes have MASLD. However, fat infiltration and inflammation in the pancreas are understudied in individuals with MASLD. In this cross-sectional MRI study, we found no relationship between fat accumulation in the pancreas and liver in a cohort of patients with MASLD. However, our results show that inflammatory and fibrotic processes in the pancreas may be interrelated to features of type 2 diabetes and to the severity of liver disease in patients with MASLD. Overall, the results suggest that pancreatic endocrine dysfunction in individuals with MASLD may be more related to glucotoxicity than to lipotoxicity. Clinical trial number: NTR7191 (Dutch Trial Register).

4.
J Magn Reson Imaging ; 59(5): 1582-1592, 2024 May.
Article in English | MEDLINE | ID: mdl-37485870

ABSTRACT

BACKGROUND: Pancreatic ductal adenocarcinoma (PDAC) stromal viscoelasticity can be measured using MR elastography (MRE). Bowel preparation regimens could affect MRE quality and knowledge on repeatability is crucial for clinical implementation. PURPOSE: To assess effects of four bowel preparation regimens on MRE quality and to evaluate repeatability and differentiate patients from healthy controls. STUDY TYPE: Prospective. POPULATION: 15 controls (41 ± 16 years; 47% female), 16 PDAC patients (one excluded, 66 ± 12 years; 40% female) with 15 age-/sex-matched controls (65 ± 11 years; 40% female). Final sample size was 25 controls and 15 PDAC. FIELD STRENGTH/SEQUENCE: 3-T, spin-echo echo-planar-imaging, turbo spin-echo, and fast field echo gradient-echo. ASSESSMENT: Four different regimens were used: fasting; scopolaminebutyl; drinking 0.5 L water; combination of 0.5 L water and scopolaminebutyl. MRE signal-to-noise ratio (SNR) was compared between all regimens. MRE repeatability (test-retest) and differences in shear wave speed (SWS) and phase angle (ϕ) were assessed in PDAC and controls. Regions-of-interest were defined for tumor, nontumorous (n = 8) tissue in PDAC, and whole pancreas in controls. Two radiologists delineated tumors twice for evaluation of intraobserver and interobserver variability. STATISTICAL TESTS: Repeated measures analysis of variance, coefficients of variation (CoVs), Bland-Altman analysis, (un)paired t-test, Mann-Whitney U-test, and Wilcoxon signed-rank test. P-value<0.05 was considered statistically significant. RESULTS: Preparation regimens did not significantly influence MRE-SNR. Therefore, the least burdensome preparation (fasting only) was continued. CoVs for tumor SWS were: intrasession (12.8%) and intersession (21.7%), and intraobserver (7.9%) and interobserver (10.3%) comparisons. For controls, CoVs were intrasession (4.6%) and intersession (6.4%). Average SWS for tumor, nontumor, and healthy tissue were: 1.74 ± 0.58, 1.38 ± 0.27, and 1.18 ± 0.16 m/sec (ϕ: 1.02 ± 0.17, 0.91 ± 0.07, and 0.85 ± 0.08 rad), respectively. Significant differences were found between all groups, except for ϕ between healthy-nontumor (P = 0.094). DATA CONCLUSION: The proposed bowel preparation regimens may not influence MRE quality. MRE may be able to differentiate between healthy tissue-tumor and tumor-nontumor. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Subject(s)
Elasticity Imaging Techniques , Pancreatic Neoplasms , Humans , Female , Middle Aged , Aged , Male , Magnetic Resonance Imaging/methods , Elasticity Imaging Techniques/methods , Prospective Studies , Pancreas/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Reproducibility of Results , Water
5.
J Magn Reson Imaging ; 59(2): 688-698, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37194646

ABSTRACT

BACKGROUND: Pancreatic ductal adenocarcinoma (PDAC) stromal disposition is thought to influence chemotherapy efficacy and increase tissue stiffness, which could be quantified noninvasively via MR elastography (MRE). Current methods cause position-based errors in pancreas location over time, hampering accuracy. It would be beneficial to have a single breath-hold acquisition. PURPOSE: To develop and test a single breath-hold three-dimensional MRE technique utilizing prospective undersampling and a compressed sensing reconstruction (CS-MRE). STUDY TYPE: Prospective. POPULATION: A total of 30 healthy volunteers (HV) (31 ± 9 years; 33% male) and five patients with PDAC (69 ± 5 years; 80% male). FIELD STRENGTH/SEQUENCE: 3-T, GRE Ristretto MRE. ASSESSMENT: First, optimization of multi breath-hold MRE was done in 10 HV using four combinations of vibration frequency, number of measured wave-phase offsets, and TE and looking at MRE quality measures in the pancreas head. Second, viscoelastic parameters delineated in the pancreas head or tumor of CS-MRE were compared against (I) 2D and (II) 3D four breath-hold acquisitions in HV (N = 20) and PDAC patients. Intrasession repeatability was assessed for CS-MRE in a subgroup of healthy volunteers (N = 15). STATISTICAL TESTS: Tests include repeated measures analysis of variance (ANOVA), Bland-Altman analysis, and coefficients of variation (CoVs). A P-value <.05 was considered statistically significant. RESULTS: Optimization of the four breath-hold acquisitions resulted in 40 Hz vibration frequency, five wave-phases, and echo time (TE) = 6.9 msec as the preferred method (4BH-MRE). CS-MRE quantitative results did not differ from 4BH-MRE. Shear wave speed (SWS) and phase angle differed significantly between HV and PDAC patients using 4BH-MRE or CS-MRE. The limits of agreement for SWS were [-0.09, 0.10] m/second and the within-subject CoV was 4.8% for CS-MRE. DATA CONCLUSION: CS-MRE might allow a single breath-hold MRE acquisition with comparable SWS and phase angle as 4BH-MRE, and it may still enable to differentiate between HV and PDAC. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 2.


Subject(s)
Elasticity Imaging Techniques , Pancreatic Neoplasms , Humans , Male , Female , Prospective Studies , Elasticity Imaging Techniques/methods , Reproducibility of Results , Breath Holding , Pancreas/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods
6.
JHEP Rep ; 6(1): 100928, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38089550

ABSTRACT

Background & Aims: Pathologists quantify liver steatosis as the fraction of lipid droplet-containing hepatocytes out of all hepatocytes, whereas the magnetic resonance-determined proton density fat fraction (PDFF) reflects the tissue triacylglycerol concentration. We investigated the linearity, agreement, and correspondence thresholds between histological steatosis and PDFF across the full clinical spectrum of liver fat content associated with non-alcoholic fatty liver disease. Methods: Using individual patient-level measurements, we conducted a systematic review and meta-analysis of studies comparing histological steatosis with PDFF determined by magnetic resonance spectroscopy or imaging in adults with suspected non-alcoholic fatty liver disease. Linearity was assessed by meta-analysis of correlation coefficients and by linear mixed modelling of pooled data, agreement by Bland-Altman analysis, and thresholds by receiver operating characteristic analysis. To explain observed differences between the methods, we used RNA-seq to determine the fraction of hepatocytes in human liver biopsies. Results: Eligible studies numbered 9 (N = 597). The relationship between PDFF and histology was predominantly linear (r = 0.85 [95% CI, 0.80-0.89]), and their values approximately coincided at 5% steatosis. Above 5% and towards higher levels of steatosis, absolute values of the methods diverged markedly, with histology exceeding PDFF by up to 3.4-fold. On average, 100% histological steatosis corresponded to a PDFF of 33.0% (29.5-36.7%). Targeting at a specificity of 90%, optimal PDFF thresholds to predict histological steatosis grades were ≥5.75% for ≥S1, ≥15.50% for ≥S2, and ≥21.35% for S3. Hepatocytes comprised 58 ± 5% of liver cells, which may partly explain the lower values of PDFF vs. histology. Conclusions: Histological steatosis and PDFF have non-perfect linearity and fundamentally different scales of measurement. Liver fat values obtained using these methods may be rendered comparable by conversion equations or threshold values. Impact and implications: Magnetic resonance-proton density fat fraction (PDFF) is increasingly being used to measure liver fat in place of the invasive liver biopsy. Understanding the relationship between PDFF and histological steatosis fraction is important for preventing misjudgement of clinical status or treatment effects in patient care. Our analysis revealed that histological steatosis fraction is often significantly higher than PDFF, and their association varies across the spectrum of fatty liver severity. These findings are particularly important for physicians and clinical researchers, who may use these data to interpret PDFF measurements in the context of histologically evaluated liver fat content.

7.
J Med Imaging Radiat Oncol ; 67(8): 895-902, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38062853

ABSTRACT

Imaging and image processing is the fundamental pillar of interventional oncology in which diagnostic, procedure planning, treatment and follow-up are sustained. Knowing all the possibilities that the different image modalities can offer is capital to select the most appropriate and accurate guidance for interventional procedures. Despite there is a wide variability in physicians preferences and availability of the different image modalities to guide interventional procedures, it is important to recognize the advantages and limitations for each of them. In this review, we aim to provide an overview of the most frequently used image guidance modalities for interventional procedures and its typical and future applications including angiography, computed tomography (CT) and spectral CT, magnetic resonance imaging, Ultrasound and the use of hybrid systems. Finally, we resume the possible role of artificial intelligence related to image in patient selection, treatment and follow-up.


Subject(s)
Artificial Intelligence , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Ultrasonography , Image Processing, Computer-Assisted , Medical Oncology
8.
Eur Radiol Exp ; 7(1): 53, 2023 09 18.
Article in English | MEDLINE | ID: mdl-37718360

ABSTRACT

BACKGROUND: Creeping fat is a pathological feature of small bowel Crohn's disease (CD), with literature suggesting that bowel resection with extended mesenteric resection is related to less postoperative recurrences. Conventional imaging is unable to accurately quantify the disease involvement (i.e., fibrosis) of creeping fat. Quantification of disease involvement could be useful in decision-making for additional extended mesenteric resection. We investigated the feasibility of magnetic resonance elastography (MRE) of the mesentery and if MRE is capable to detect fibrotic disease involvement of mesentery in active CD. METHODS: Multifrequency MRE yielded spatial stiffness (shear wave speed, SWS, |G*|) and fluidity maps (φ). Viscoelastic properties of seven CD patients' mesentery were compared to age- and sex-matched healthy volunteers (HV) (Mann-Whitney U-test). Within CD patients, the affected and "presumably" unaffected mesentery were compared (Wilcoxon-signed rank test). Repeatability was tested in 15 HVs (Bland-Altman analysis, coefficient of variation [CoV]). Spearman rank correlations were used to investigate the relation between microscopically scored amount of mesenteric fibrosis and viscoelastic parameters. RESULTS: SWS, |G*|, and φ of affected mesentery in CD were higher compared to HV (p = 0.017, p = 0.001, p = 0.017). Strong correlations were found between percentage of area of mesenteric fibrosis and SWS and |G*| (p < 0.010). No differences were found within CD between affected and presumably unaffected mesentery. Repeatability of SWS showed 95% limits of agreement of (-0.09, 0.13 m/s) and within-subject CoV of 5.3%. CONCLUSION: MRE may have the potential to measure fibrotic disease involvement of the mesentery in CD, possibly guiding clinical decision-making with respect to extended mesenteric resection. TRIAL REGISTRATION: Dutch trial register, NL9105 , registered 7 December 2020. RELEVANCE STATEMENT: MRE may have the potential to measure the amount of mesenteric fibrosis of the affected mesenteric fat in active Crohn's disease, giving more insight into disease progression and could potentially play a role in clinical decision-making for extended mesenteric resection. KEY POINTS: • MRE of the mesentery in patients with active CD is feasible. • Fluidity and stiffness of the mesentery increase in active CD, while stiffness correlates with the histopathological amount of mesenteric fibrosis. • MRE provides biomarkers to quantify mesenteric disease activity in active CD.


Subject(s)
Crohn Disease , Elasticity Imaging Techniques , Humans , Crohn Disease/diagnostic imaging , Cross-Sectional Studies , Fibrosis , Mesentery/diagnostic imaging , Prospective Studies , Male , Female
9.
Front Physiol ; 13: 942495, 2022.
Article in English | MEDLINE | ID: mdl-36148303

ABSTRACT

Recent literature suggests that tri-exponential models may provide additional information and fit liver intravoxel incoherent motion (IVIM) data more accurately than conventional bi-exponential models. However, voxel-wise fitting of IVIM results in noisy and unreliable parameter maps. For bi-exponential IVIM, neural networks (NN) were able to produce superior parameter maps than conventional least-squares (LSQ) generated images. Hence, to improve parameter map quality of tri-exponential IVIM, we developed an unsupervised physics-informed deep neural network (IVIM3-NET). We assessed its performance in simulations and in patients with non-alcoholic fatty liver disease (NAFLD) and compared outcomes with bi-exponential LSQ and NN fits and tri-exponential LSQ fits. Scanning was performed using a 3.0T free-breathing multi-slice diffusion-weighted single-shot echo-planar imaging sequence with 18 b-values. Images were analysed for visual quality, comparing the bi- and tri-exponential IVIM models for LSQ fits and NN fits using parameter-map signal-to-noise ratios (SNR) and adjusted R 2. IVIM parameters were compared to histological fibrosis, disease activity and steatosis grades. Parameter map quality improved with bi- and tri-exponential NN approaches, with a significant increase in average parameter-map SNR from 3.38 to 5.59 and 2.45 to 4.01 for bi- and tri-exponential LSQ and NN models respectively. In 33 out of 36 patients, the tri-exponential model exhibited higher adjusted R 2 values than the bi-exponential model. Correlating IVIM data to liver histology showed that the bi- and tri-exponential NN outperformed both LSQ models for the majority of IVIM parameters (10 out of 15 significant correlations). Overall, our results support the use of a tri-exponential IVIM model in NAFLD. We show that the IVIM3-NET can be used to improve image quality compared to a tri-exponential LSQ fit and provides promising correlations with histopathology similar to the bi-exponential neural network fit, while generating potentially complementary additional parameters.

11.
Comput Biol Med ; 142: 105191, 2022 03.
Article in English | MEDLINE | ID: mdl-35026571

ABSTRACT

Automatic cardiac chamber and left ventricular (LV) myocardium segmentation over the cardiac cycle significantly extends the utilization of contrast-enhanced cardiac CT, potentially enabling in-depth assessment of cardiac function. Therefore, we evaluate an automatic method for cardiac chamber and LV myocardium segmentation in 4D cardiac CT. In this study, 4D contrast-enhanced cardiac CT scans of 1509 patients selected for transcatheter aortic valve implantation with 21,605 3D images, were divided into development (N = 12) and test set (N = 1497). 3D convolutional neural networks were trained with end-systolic (ES) and end-diastolic (ED) images. Dice similarity coefficient (DSC) and average symmetric surface distance (ASSD) were computed for 3D segmentations at ES and ED in the development set via cross-validation, and for 2D segmentations in four cardiac phases for 81 test set patients. Segmentation quality in the full test set of 1497 patients was assessed visually on a three-point scale per structure based on estimated overlap with the ground truth. Automatic segmentation resulted in a mean DSC of 0.89 ± 0.10 and ASSD of 1.43 ± 1.45 mm in 12 patients in 3D, and a DSC of 0.89 ± 0.08 and ASSD of 1.86 ± 1.20 mm in 81 patients in 2D. The qualitative evaluation in the whole test set of 1497 patients showed that automatic segmentations were assigned grade 1 (clinically useful) in 98.5%, 92.2%, 83.1%, 96.3%, and 91.6% of cases for LV cavity and myocardium, right ventricle, left atrium, and right atrium. Our automatic method using convolutional neural networks performed clinically useful segmentation across the cardiac cycle in a large set of 4D cardiac CT images, potentially enabling in-depth assessment of cardiac function.


Subject(s)
Deep Learning , Four-Dimensional Computed Tomography , Heart/diagnostic imaging , Humans , Image Processing, Computer-Assisted/methods , Neural Networks, Computer
12.
J Magn Reson Imaging ; 54(6): 1937-1949, 2021 12.
Article in English | MEDLINE | ID: mdl-33991378

ABSTRACT

BACKGROUND: Noninvasive diagnostic methods are urgently required in disease stratification and monitoring in nonalcoholic fatty liver disease (NAFLD). Multiparametric magnetic resonance imaging (MRI) is a promising technique to assess hepatic steatosis, inflammation, and fibrosis, potentially enabling noninvasive identification of individuals with active and advanced stages of NAFLD. PURPOSE: To examine the diagnostic performance of multiparametric MRI for the assessment of disease severity along the NAFLD disease spectrum with comparison to histological scores. STUDY TYPE: Prospective, cohort. POPULATION: Thirty-seven patients with NAFLD. FIELD STRENGTH/SEQUENCE: Multiparametric MRI at 3.0 T consisted of magnetic resonance (MR) spectroscopy (MRS) with multi-echo stimulated-echo acquisition mode, magnitude-based and three-point Dixon using a two-dimensional multi-echo gradient echo, MR elastography (MRE) using a generalized multishot gradient-recalled echo sequence and intravoxel incoherent motion (IVIM) using a multislice diffusion weighted single-shot echo-planar sequence. ASSESSMENT: Histological steatosis grades were compared to proton density fat fraction measured by MRS (PDFFMRS ), magnitude-based MRI (PDFFMRI-M ), and three-point Dixon (PDFFDixon ), as well as FibroScan® controlled attenuation parameter (CAP). Fibrosis and disease activity were compared to IVIM and MRE. FibroScan® liver stiffness measurements were compared to fibrosis levels. Diagnostic performance of all imaging parameters was determined for distinction between simple steatosis and nonalcoholic steatohepatitis (NASH). STATISTICAL TESTS: Spearman's rank test, Kruskal-Wallis test, Dunn's post-hoc test with Holm-Bonferroni P-value adjustment, receiver operating characteristic curve analysis. A P-value <0.05 was considered statistically significant. RESULTS: Histological steatosis grade correlated significantly with PDFFMRS (rs  = 0.66, P < 0.001), PDFFMRI-M (rs  = 0.68, P < 0.001), and PDFFDixon (rs  = 0.67, P < 0.001), whereas no correlation was found with CAP. MRE and IVIM diffusion and perfusion significantly correlated with disease activity (rs  = 0.55, P < 0.001, rs  = -0.40, P = 0.016, rs  = -0.37, P = 0.027, respectively) and fibrosis (rs  = 0.55, P < 0.001, rs  = -0.46, P = 0.0051; rs  = -0.53, P < 0.001, respectively). MRE and IVIM diffusion had the highest area-under-the-curve for distinction between simple steatosis and NASH (0.79 and 0.73, respectively). DATA CONCLUSION: Multiparametric MRI is a promising method for noninvasive, accurate, and sensitive distinction between simple hepatic steatosis and NASH, as well as for the assessment of steatosis and fibrosis severity. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: 2.


Subject(s)
Elasticity Imaging Techniques , Non-alcoholic Fatty Liver Disease , Biopsy , Humans , Liver/diagnostic imaging , Magnetic Resonance Imaging , Non-alcoholic Fatty Liver Disease/diagnostic imaging , Prospective Studies
13.
Sci Rep ; 11(1): 1403, 2021 01 14.
Article in English | MEDLINE | ID: mdl-33446701

ABSTRACT

Changes in myocardial stiffness may represent a valuable biomarker for early tissue injury or adverse remodeling. In this study, we developed and validated a novel transducer-free magnetic resonance elastography (MRE) approach for quantifying myocardial biomechanics using aortic valve closure-induced shear waves. Using motion-sensitized two-dimensional pencil beams, septal shear waves were imaged at high temporal resolution. Shear wave speed was measured using time-of-flight of waves travelling between two pencil beams and corrected for geometrical biases. After validation in phantoms, results from twelve healthy volunteers and five cardiac patients (two left ventricular hypertrophy, two myocardial infarcts, and one without confirmed pathology) were obtained. Torsional shear wave speed in the phantom was 3.0 ± 0.1 m/s, corresponding with reference speeds of 2.8 ± 0.1 m/s. Geometrically-biased flexural shear wave speed was 1.9 ± 0.1 m/s, corresponding with simulation values of 2.0 m/s. Corrected septal shear wave speeds were significantly higher in patients than healthy volunteers [14.1 (11.0-15.8) m/s versus 3.6 (2.7-4.3) m/s, p = 0.001]. The interobserver 95%-limits-of-agreement in healthy volunteers were ± 1.3 m/s and interstudy 95%-limits-of-agreement - 0.7 to 1.2 m/s. In conclusion, myocardial shear wave speed can be measured using aortic valve closure-induced shear waves, with cardiac patients showing significantly higher shear wave speeds than healthy volunteers. This non-invasive measure may provide valuable insights into the pathophysiology of heart failure.


Subject(s)
Elasticity Imaging Techniques , Hypertrophy, Left Ventricular/diagnostic imaging , Magnetic Resonance Imaging , Models, Cardiovascular , Myocardial Contraction , Myocardial Infarction/diagnostic imaging , Female , Humans , Male
14.
Eur Radiol ; 31(3): 1588-1596, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32910234

ABSTRACT

OBJECTIVES: To determine the diagnostic accuracy of controlled attenuation parameter (CAP) on FibroScan® in detecting and grading steatosis in a screening setting and perform a head-to-head comparison with conventional B-mode ultrasound. METHODS: Sixty children with severe obesity (median BMI z-score 3.37; median age 13.7 years) were evaluated. All underwent CAP and US using a standardized scoring system. Magnetic resonance spectroscopy proton density fat fraction (MRS-PDFF) was used as a reference standard. RESULTS: Steatosis was present in 36/60 (60%) children. The areas under the ROC (AUROC) of CAP for the detection of grade ≥ S1, ≥ S2, and ≥ S3 steatosis were 0.80 (95% CI: 0.67-0.89), 0.77 (95% CI: 0.65-0.87), and 0.79 (95% CI: 0.66-0.88), respectively. The AUROC of US for the detection of grade ≥ S1 steatosis was 0.68 (95% CI: 0.55-0.80) and not significantly different from that of CAP (p = 0.09). For detecting ≥ S1 steatosis, using the optimal cutoffs, CAP (277 dB/m) and US (US steatosis score ≥ 2) had a sensitivity of 75% and 61% and a specificity of 75% and 71%, respectively. When using echogenicity of liver parenchyma as only the scoring item, US had a sensitivity of 70% and specificity of 46% to detect ≥ S1 steatosis. The difference in specificity of CAP and US when using only echogenicity of liver parenchyma of 29% was significant (p = 0.04). CONCLUSION: The overall performance of CAP is not significantly better than that of US in detecting steatosis in children with obesity, provided that the standardized scoring of US features is applied. When US is based on liver echogenicity only, CAP outperforms US in screening for any steatosis (≥ S1). KEY POINTS: • The areas under the ROC curves of CAP and ultrasound (US) for detecting grade ≥ S1 steatosis were 0.80 and 0.68, respectively, and were not significantly different (p = 0.09). • For detecting grade ≥ S1 steatosis in severely obese children, CAP had a sensitivity of 75% and a specificity of 75% at its optimal cutoff value of 277 dB/m. • For detecting grade ≥ S1 steatosis in clinical practice, both CAP and US can be used, provided that the standardized scoring of US images is used.


Subject(s)
Elasticity Imaging Techniques , Fatty Liver , Non-alcoholic Fatty Liver Disease , Obesity, Morbid , Adolescent , Biopsy , Child , Fatty Liver/complications , Fatty Liver/diagnostic imaging , Humans , Liver/diagnostic imaging , ROC Curve , Ultrasonography
15.
Hepatol Commun ; 4(11): 1578-1590, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33163830

ABSTRACT

The intestinal microbiota has been linked to the development and prevalence of steatohepatitis in humans. Interestingly, steatohepatitis is significantly lower in individuals taking a plant-based, low-animal-protein diet, which is thought to be mediated by gut microbiota. However, data on causality between these observations in humans is scarce. In this regard, fecal microbiota transplantation (FMT) using healthy donors is safe and is capable of changing microbial composition in human disease. We therefore performed a double-blind randomized controlled proof-of-principle study in which individuals with hepatic steatosis on ultrasound were randomized to two study arms: lean vegan donor (allogenic n = 10) or own (autologous n = 11) FMT. Both were performed three times at 8-week intervals. A liver biopsy was performed at baseline and after 24 weeks in every subject to determine histopathology (Nonalcoholic Steatohepatitis Clinical Research Network) classification and changes in hepatic gene expression based on RNA sequencing. Secondary outcome parameters were changes in intestinal microbiota composition and fasting plasma metabolomics. We observed a trend toward improved necro-inflammatory histology, and found significant changes in expression of hepatic genes involved in inflammation and lipid metabolism following allogenic FMT. Intestinal microbial community structure changed following allogenic FMT, which was associated with changes in plasma metabolites as well as markers of . Conclusion: Allogenic FMT using lean vegan donors in individuals with hepatic steatosis shows an effect on intestinal microbiota composition, which is associated with beneficial changes in plasma metabolites and markers of steatohepatitis.

17.
PLoS One ; 14(8): e0220835, 2019.
Article in English | MEDLINE | ID: mdl-31415613

ABSTRACT

PURPOSE: Pharmacokinetic models facilitate assessment of properties of the micro-vascularization based on DCE-MRI data. However, accurate pharmacokinetic modeling in the liver is challenging since it has two vascular inputs and it is subject to large deformation and displacement due to respiration. METHODS: We propose an improved pharmacokinetic model for the liver that (1) analytically models the arrival-time of the contrast agent for both inputs separately; (2) implicitly compensates for signal fluctuations that can be modeled by varying applied flip-angle e.g. due to B1-inhomogeneity. Orton's AIF model is used to analytically represent the vascular input functions. The inputs are independently embedded into the Sourbron model. B1-inhomogeneity-driven variations of flip-angles are accounted for to justify the voxel's displacement with respect to a pre-contrast image. RESULTS: The new model was shown to yield lower root mean square error (RMSE) after fitting the model to all but a minority of voxels compared to Sourbron's approach. Furthermore, it outperformed this existing model in the majority of voxels according to three model-selection criteria. CONCLUSION: Our work primarily targeted to improve pharmacokinetic modeling for DCE-MRI of the liver. However, other types of pharmacokinetic models may also benefit from our approaches, since the techniques are generally applicable.


Subject(s)
Contrast Media/pharmacokinetics , Gadolinium DTPA/pharmacokinetics , Liver Neoplasms/diagnostic imaging , Liver/diagnostic imaging , Magnetic Resonance Imaging/methods , Aged , Algorithms , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Models, Biological
18.
Abdom Radiol (NY) ; 44(8): 2740-2750, 2019 08.
Article in English | MEDLINE | ID: mdl-31069479

ABSTRACT

BACKGROUND: Survival outcomes of patients with hepatocellular carcinoma (HCC) treated with transarterial chemoembolization (TACE) are heterogeneous. Measuring the apparent diffusion coefficient (ADC) using diffusion-weighted imaging (DWI) may improve overall survival prediction. AIM: To assess the value of measuring the ADC before and after TACE in predicting overall survival. METHODS: A retrospective analysis was performed in HCC patients treated with TACE at a tertiary referral center between 2008 and 2017. The ADC values and changes in ADC value (ΔADC) of HCC lesions (≥ 1 cm) and liver parenchyma were assessed by DWI ≤ 3 months before and after first TACE. Pre- and post-TACE ADC values were compared with tumor response according to mRECIST and correlated with overall survival (OS) in a univariable and multivariable Cox-regression analysis. RESULTS: A total of 89 patients were included, mostly Child-Pugh A (85%) and BCLC stage B (53%) with a median OS of 21.7 months (95% CI 17.6-25.9). Tumor ADC increased from 1081 mm2/s before (IQR 964-1225) to 1328 mm2/s (IQR 1197-1560) after TACE (p < 0.001). Responders according to mRECIST showed a higher ΔADC after first TACE than non-responders (26 vs. 14%, p = 0.048). Pre-TACE ADC and ΔADC were not significantly associated with OS in both univariable and multivariable analysis, whereas response according to mRECIST remained an independent predictor of OS. CONCLUSION: mRECIST was confirmed as an independent prognostic factor of OS, but pre- or post-TACE ADC measurements were not. Response according to mRECIST was associated with a higher increase in ADC than non-response.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/therapy , Diffusion Magnetic Resonance Imaging/methods , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/therapy , Aged , Carcinoma, Hepatocellular/mortality , Chemoembolization, Therapeutic , Female , Humans , Image Interpretation, Computer-Assisted , Liver Neoplasms/mortality , Male , Middle Aged , Retrospective Studies , Survival Analysis
19.
Phys Med Biol ; 64(4): 045007, 2019 02 06.
Article in English | MEDLINE | ID: mdl-30566925

ABSTRACT

BACKGROUND: Magnetic resonance elastography (MRE) is used to non-invasively estimate biomechanical tissue properties via the imaging of propagating mechanical shear waves. Several factors including mechanical transducer design, MRI sequence design and viscoelastic reconstruction influence data quality and hence the reliability of the derived biomechanical properties. PURPOSE: To design and characterize a novel mechanical MRE transducer concept based on a rotational eccentric mass, coined the gravitational transducer. MATERIALS AND METHODS: Table top measurements were performed using accelerometers to characterize the frequency response of the new transducer concept at different driving frequencies (f VIB) and different rotating masses. These were compared to a commercially available pneumatically driven MRE transducer. MR data were acquired on a 3T scanner using a fractionally encoded gradient echo MRE sequence in three healthy volunteers. Acceleration and displacement spectra were plotted in units of g and mm, respectively, and visually compared, emphasizing the ratio between the peaks at f VIB and its 2nd harmonic, a known cause of error in the reconstruction of biomechanical properties as is explored in more detail in numerical simulations here. No formal statistical testing was performed in this proof-of-principle paper. RESULTS: The new transducer concept shows-as expected from theory-a quadratic or linear increase of acceleration amplitude with increase in f VIB or mass, respectively. Furthermore, different versions of the transducer show markedly lower 2nd harmonic-to-f VIB ratios compared to the commercially available pneumatically driven transducer. Displacement was constant over a range of f VIB, in accordance with theory. Phantom and in vivo data show low nonlinearity and excellent data quality. CONCLUSION: The table top measurements are in concordance with the theory behind a transducer based on a rotational eccentric mass. The resulting constant displacement amplitude irrespective of f VIB and low 2nd harmonic-to-f VIB ratio result in low nonlinearity and high data fidelity in both phantom and in vivo examples.


Subject(s)
Elasticity Imaging Techniques/methods , Liver/diagnostic imaging , Magnetic Resonance Imaging/methods , Models, Theoretical , Phantoms, Imaging , Transducers , Computer Simulation , Gravitation , Healthy Volunteers , Humans
20.
NMR Biomed ; 31(5): e3908, 2018 05.
Article in English | MEDLINE | ID: mdl-29601114

ABSTRACT

Magnetic resonance elastography (MRE) utilizes phase contrast magnetic resonance imaging (MRI), which is phase locked to externally generated mechanical vibrations, to measure the three-dimensional wave displacement field. At least four measurements with linear-independent encoding directions are necessary to correct for spurious phase contributions if effects from imaging gradients are non-negligible. In MRE, three encoding schemes have been used: unbalanced four- and six-point and balanced four-point ('tetrahedral') encoding. The first two sensitize to motion with orthogonal gradients, with the four-point method acquiring a single reference scan without motion sensitization, whereas three additional scans with inverted gradients are used with six-point encoding, leading to two-fold higher displacement-to-noise ratio (DNR) and 50% longer scan duration. Balanced four-point (tetrahedral) encoding encodes along the four diagonals of a cube, with one direction serving as a reference for the other three encoding directions, similar to four-point encoding. The objective of this work is to introduce a theoretical framework to compare different motion sensitization strategies with respect to their motion encoding efficiency in two fundamental encoding limits, the gradient strength limit and the dynamic range limit, which are both placed in relation to conventional gradient recalled echo (GRE)- and spin echo (SE)-based MRE sequences. We apply the framework to the three aforementioned schemes and show that the motion encoding efficiency of unbalanced four- and six-point encoding schemes in the gradient-limited regime can be increased by a factor of 1.5 when using all physical gradient channels concurrently. Furthermore, it is demonstrated that reversing the direction of the reference in balanced four-point (tetrahedral) encoding results in the Hadamard encoding scheme, which leads to increased DNR by 2 compared with balanced four-point encoding and 2.8 compared with unbalanced four-point encoding. As an example, we show that optimal encoding can be utilized to reduce the acquisition time of standard liver MRE in vivo from four to two breath holds.


Subject(s)
Elasticity Imaging Techniques , Magnetic Resonance Imaging , Motion , Echo-Planar Imaging , Humans , Phantoms, Imaging