Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Biosens Bioelectron ; 206: 114123, 2022 Jun 15.
Article in English | MEDLINE | ID: mdl-35259608

ABSTRACT

We integrated a magnetohydrodynamic fluid extractor with an amperometric glucose biosensor to develop a wearable device for non-invasive glucose monitoring. Reproducible fluid extraction through the skin and efficient transport of the extracted fluid to the biosensor surface are prerequisites for non-invasive glucose monitoring. We optimized the enzyme immobilization and the interface layer between the sensing device and the skin. The monitoring device was evaluated by extracting fluid through porcine skin followed by glucose detection at the biosensor. The biosensor featured a screen-printed layer of Prussian Blue that was coated with a layer containing glucose oxidase. Both physical entrapment of glucose oxidase in chitosan and tethering of glucose oxidase to electrospun nanofibers were evaluated. Binding of glucose oxidase to nanofibers under mild conditions provided a stable biosensor with analytical performance suitable for accurate detection of micromolar concentrations of glucose. Hydrogels of varying thickness (95-2000 µm) as well as a thin (30 µm) nanofibrous polycaprolactone mat were studied as an interface layer between the biosensor and the skin. The effect of mass transfer phenomena at the biosensor-skin interface on the analytical performance of the biosensor was evaluated. The sensing device detected glucose extracted through porcine skin with an apparent (overall) sensitivity of -0.8 mA/(M·cm2), compared to a sensitivity of -17 mA/(M·cm2) for measurement in solution. The amperometric response of the biosensor correlated with the glucose concentration in the fluid that had been extracted through porcine skin with the magnetohydrodynamic technique.


Subject(s)
Biosensing Techniques , Glucose Oxidase , Blood Glucose , Blood Glucose Self-Monitoring , Enzymes, Immobilized , Extracellular Fluid , Glucose
2.
Sci Rep ; 11(1): 7609, 2021 04 07.
Article in English | MEDLINE | ID: mdl-33828144

ABSTRACT

Out of 463 million people currently with diabetes, 232 million remain undiagnosed. Diabetes is a threat to human health, which could be mitigated via continuous self-monitoring of glucose. In addition to blood, interstitial fluid is considered to be a representative sample for glucose monitoring, which makes it highly attractive for wearable on-body sensing. However, new technologies are needed for efficient and noninvasive sampling of interstitial fluid through the skin. In this report, we introduce the use of Lorentz force and magnetohydrodynamics to noninvasively extract dermal interstitial fluid. Using porcine skin as an ex-vivo model, we demonstrate that the extraction rate of magnetohydrodynamics is superior to that of reverse iontophoresis. This work seeks to provide a safe, effective, and noninvasive sampling method to unlock the potential of wearable sensors in needle-free continuous glucose monitoring devices that can benefit people living with diabetes.


Subject(s)
Blood Glucose Self-Monitoring/methods , Extracellular Fluid/chemistry , Glucose/analysis , Animals , Biosensing Techniques/instrumentation , Diabetes Mellitus/metabolism , Glucose/metabolism , Hydrodynamics , Magnets/chemistry , Models, Animal , Skin/metabolism , Skin Physiological Phenomena , Swine , Wearable Electronic Devices
SELECTION OF CITATIONS
SEARCH DETAIL