Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-39276322

ABSTRACT

The most popular model of the bone healing considers the fracture callus as poroelastic medium. As such it requires an assumption of the callus' external permeability. In this work a systematic study of the influence of the permeability of the callus boundary on the simulated bone healing progress is performed. The results show, that these conditions starts to play significant role with the decrease of the callus size. Typically enforced impermeability inhibits the progress of healing during simulation. A remedy for this effect is imposing drainage conditions at the callus' boundary.

2.
J Biomed Mater Res B Appl Biomater ; 112(8): e35463, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39115314

ABSTRACT

Secondary healing of fractured bones requires an application of an appropriate fixator. In general, steel or titanium devices are used mostly. However, in recent years, composite structures arise as an attractive alternative due to high strength to weight ratio and other advantages like, for example, radiolucency. According to Food and Drug Administration (FDA), the only unidirectionally reinforced composite allowed to be implanted in human bodies is carbon fiber (CF)-reinforced poly-ether-ether-ketone (PEEK). In this work, the healing process of long bone assembled with CF/PEEK plates with cross- and angle-ply lay-up configurations is studied in the framework of finite element method. The healing is simulated by making use of the mechanoregulation model basing on the Prendergast theory. Cells transformation is determined by the octahedral shear strain and interstitial fluid velocity. The process runs iteratively assuming single load cycle each day. The fracture is subjected to axial and transverse forces. In the computations, the Abaqus program is used. It is shown that the angle-ply lamination scheme of CF/PEEK composite seems to provide better conditions for the transformation of the soft callus into the bone tissue.


Subject(s)
Benzophenones , Bone Plates , Carbon Fiber , Fracture Healing , Ketones , Polyethylene Glycols , Polymers , Ketones/chemistry , Carbon Fiber/chemistry , Polyethylene Glycols/chemistry , Polymers/chemistry , Humans , Carbon/chemistry , Fractures, Bone , Finite Element Analysis
3.
PLoS One ; 19(5): e0303752, 2024.
Article in English | MEDLINE | ID: mdl-38753866

ABSTRACT

BACKGROUND: First metatarsophalangeal joint arthrodesis is a typical medical treatment performed in cases of arthritis or joint deformity. The gold standard for this procedure is arthrodesis stabilisation with the dorsally positioned plate. However, according to the authors' previous studies, medially positioned plate provides greater bending stiffness. It is worth to compare the mechanical conditions for bone formation in the fracture callus for both placements of the locking plate. METHODS: Two finite element models of the first metatarsophalangeal joint with the dorsally and medially positioned plate were defined in the Abaqus software to simulate differentiation of the fracture callus. A simplified load application, i.e. one single step per each day and the diffusion of the mesenchymal stem cells into the fracture region were assumed in an iterative hardening process. The changes of the mesenchymal stem cells into different phenotypes during the callus stiffening were governed by the octahedral shear strain and interstitial fluid velocity according to Prendergast mechanoregulation theory. Basing on the obtained results the progress of the cartilage and bone tissues formation and their distribution within the callus were compared between two models. FINDINGS: The obtained results suggest that after 6 weeks of simulation the healing progress is in general comparable for both plates. However, earlier closing of external callus was observed for the medially positioned plate which had greater vertical bending stiffness. This process enables faster internal callus hardening and promotes symmetrical bridging.


Subject(s)
Arthrodesis , Bone Plates , Finite Element Analysis , Metatarsophalangeal Joint , Arthrodesis/methods , Humans , Metatarsophalangeal Joint/surgery , Biomechanical Phenomena , Bony Callus , Fracture Healing
4.
J Biomech ; 157: 111736, 2023 08.
Article in English | MEDLINE | ID: mdl-37517283

ABSTRACT

Connective fibrous tissues, such as tendons and ligaments, in humans and animals exhibit hyperelastic behaviour. The constitution of the material of these tissues is anisotropic due to the presence of the collagen fibres, where one family of fibres is the typical case. Traumatic events and/or aging may sometimes lead to the damage of the tissue. The study of motion of affected joints or limbs is usually not permitted in vivo. This is where finite element method (FEM) becomes useful as a premise for general analysis, surgical planning or designing of implants and medical treatment. One of the most often used FEM commercial programs is the field of the biomechanics is Abaqus. The present study discusses the potential of user subroutine UANISOHYPER_INV in this code to analyse response of transversely isotropic tissue with damage in quasi-static range. This subroutine requires providing the material energy function and its derivatives only. The stress tensor and constitutive matrix are computed by the software automatically. To the best of the Authors' knowledge this procedure provides the easiest way to simulate the anisotropic hyperelastic material behaviour in Abaqus. In this study its usage is extended onto the damage response simulation. The verification of the approach and its validation against experimental data indicates its efficiency.


Subject(s)
Ligaments , Software , Animals , Humans , Elasticity , Finite Element Analysis , Stress, Mechanical , Computer Simulation , Ligaments/physiology , Models, Biological
5.
PLoS One ; 16(5): e0250397, 2021.
Article in English | MEDLINE | ID: mdl-33945554

ABSTRACT

BACKGROUND: Soft tissue tension is treated as a crucial factor influencing the post-THA dislocation. The femoral offset is regarded as one of the major parameters responsible for the stabilization of the prosthesis. It is unclear which soft tissue is mostly affected by the offset changes. METHODS: A finite element model of the hip was created. The model comprised muscles, bones, a stem, the acetabular component and a liner. The muscles were modelled as a Hill-type musculo-tendon nonlinear springs. Nonlinear analyses of the hip flexion and internal rotation were performed for the two values of the femoral stem offset. RESULTS: We observed that the quadratus femoris and gluteus medius produce the largest resisting moment opposing the external load excreted by the surgeon during the intraoperative hip dislocation test. CONCLUSIONS: An increased femoral offset increases the stretching of the quadratus femoris muscle significantly and provides the growth of its initial passive force. This muscle serves as a stiff band, providing stabilisation of the hip prosthesis, measured during the simulated intraoperative test.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Computer Simulation , Femur/physiology , Muscle, Skeletal/physiology , Prosthesis Failure/etiology , Arthroplasty, Replacement, Hip/adverse effects , Biomechanical Phenomena , Femur/surgery , Finite Element Analysis , Hip/physiology , Hip/surgery , Humans , Muscle, Skeletal/surgery
SELECTION OF CITATIONS
SEARCH DETAIL