Arch Cardiovasc Dis ; 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38704288

ABSTRACT

BACKGROUND: In patients with congenital long QT syndrome (LQTS), the risk of ventricular arrhythmia is correlated with the duration of the corrected QT interval and the changes in the ST-T wave pattern on the 12-lead surface electrocardiogram (12L-ECG). Remote monitoring of these variables could be useful. AIM: To evaluate the abilities of two wearable electrocardiogram devices (Apple Watch and KardiaMobile 6L) to provide reliable electrocardiograms in terms of corrected QT interval and ST-T wave patterns in patients with LQTS. METHODS: In a prospective multicentre study (ClinicalTrials.gov identifier: NCT04728100), a 12L-ECG, a 6-lead KardiaMobile 6L electrocardiogram and two single-lead Apple Watch electrocardiograms were recorded in patients with LQTS. The corrected QT interval and ST-T wave patterns were evaluated manually. RESULTS: Overall, 98 patients with LQTS were included; 12.2% were children and 92.8% had a pathogenic variant in an LQTS gene. The main genotypes were LQTS type 1 (40.8%), LQTS type 2 (36.7%) and LQTS type 3 (7.1%); rarer genotypes were also represented. When comparing the ST-T wave patterns obtained with the 12L-ECG, the level of agreement was moderate with the Apple Watch (k=0.593) and substantial with the KardiaMobile 6L (k=0.651). Regarding the corrected QT interval, the correlation with 12L-ECG was strong for the Apple Watch (r=0.703 in lead II) and moderate for the KardiaMobile 6L (r=0.593). There was a slight overestimation of corrected QT interval with the Apple Watch and a subtle underestimation with the KardiaMobile 6L. CONCLUSIONS: In patients with LQTS, the corrected QT interval and ST-T wave patterns obtained with the Apple Watch and the KardiaMobile 6L correlated with the 12L-ECG. Although wearable electrocardiogram devices cannot replace the 12L-ECG for the follow-up of these patients, they could be interesting additional monitoring tools.

2.
Eur Heart J ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748258

ABSTRACT

BACKGROUND AND AIMS: Patients with repaired tetralogy of Fallot remain at risk of life-threatening ventricular tachycardia related to slow-conducting anatomical isthmuses (SCAIs). Preventive ablation of SCAI identified by invasive electroanatomical mapping is increasingly performed. This study aimed to non-invasively identify SCAI using 3D late gadolinium enhancement cardiac magnetic resonance (3D-LGE-CMR). METHODS: Consecutive tetralogy of Fallot patients who underwent right ventricular electroanatomical mapping (RV-EAM) and 3D-LGE-CMR were included. High signal intensity threshold for abnormal myocardium was determined based on direct comparison of bipolar voltages and signal intensity by co-registration of RV-EAM with 3D-LGE-CMR. The diagnostic performance of 3D-LGE-CMR to non-invasively identify SCAI was determined, validated in a second cohort, and compared with the discriminative ability of proposed risk scores. RESULTS: The derivation cohort consisted of 48 (34 ± 16 years) and the validation cohort of 53 patients (36 ± 18 years). In the derivation cohort, 78 of 107 anatomical isthmuses (AIs) identified by EAM were normal-conducting AI, 22 were SCAI, and 7 blocked AI. High signal intensity threshold was 42% of the maximal signal intensity. The sensitivity and specificity of 3D-LGE-CMR for identifying SCAI or blocked AI were 100% and 90%, respectively. In the validation cohort, 85 of 124 AIs were normal-conducting AI, 36 were SCAI, and 3 blocked AI. The sensitivity and specificity of 3D-LGE-CMR were 95% and 91%, respectively. All risk scores showed an at best modest performance to identify SCAI (area under the curve ≤ .68). CONCLUSIONS: 3D late gadolinium enhancement cardiac magnetic resonance can identify SCAI with excellent accuracy and may refine non-invasive risk stratification and patient selection for invasive EAM in tetralogy of Fallot.

3.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38582974

ABSTRACT

AIMS: The ultra-low-temperature cryoablation (ULTC) ablation system using -196°C N2 cryogen has been reported to create lesions with freeze duration-dependent depth titratable to over 10 mm with minimum attenuation by scar. Cryocure-VT (NCT04893317) was a first-in-human clinical trial evaluating the safety and efficacy of a novel, purpose-built ULTC catheter in endocardial ablation of scar-dependent ventricular tachycardias (VTs). METHODS AND RESULTS: This prospective, multi-centre study enrolled patients referred for de novo or second ablations of recurrent monomorphic VT of both ischaemic and non-ischaemic aetiologies. Primary safety and efficacy endpoints of the study were freedom from device- or procedure-related major adverse events (MAEs) up to 30 days post-ablation, acute non-inducibility of clinical VTs at the end of the procedure, and freedom from sustained VT or implantable defibrillator intervention at 6 months. Ultra-low-temperature cryoablation was performed in 64 patients (age 67 ± 11 years, 78% ischaemic, ejection fraction = 35 ± 10%) at 9 centres. The primary acute effectiveness endpoint was achieved in 94% (51/54) of patients in whom post-ablation induction was attempted. There were no protocol-defined MAEs; four procedure-related serious adverse events resolved without clinical sequelae. At 6-month follow-up, 38 patients (60.3%) remained VT-free, and freedom from defibrillator shock was 81.0%, with no significant difference between ischaemic and non-ischaemic cohorts. In 47 patients with defibrillator for at least 6 months prior to the ablation, the VT burden was reduced from median of 4, inter-quartile range (IQR, 1-9) to 0, IQR (0-2). CONCLUSION: In this first-in-human multi-centre experience, endocardial ULTC ablation of monomorphic VT appears safe and effective in patients with both ischaemic-cardiomyopathy and non-ischaemic-cardiomyopathy. CLINICAL TRIAL REGISTRATION: NCT04893317.


Subject(s)
Cardiomyopathies , Catheter Ablation , Cryosurgery , Tachycardia, Ventricular , Aged , Humans , Middle Aged , Cardiomyopathies/complications , Cardiomyopathies/diagnosis , Cardiomyopathies/surgery , Catheter Ablation/adverse effects , Cicatrix/complications , Cryosurgery/adverse effects , Prospective Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Temperature , Treatment Outcome
5.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38445836

ABSTRACT

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Subject(s)
Brugada Syndrome , Defibrillators, Implantable , Pacemaker, Artificial , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Brugada Syndrome/therapy , Electrocardiography/methods , Electrocardiography, Ambulatory/methods , Adult
6.
Arch Cardiovasc Dis ; 117(3): 224-231, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38302391

ABSTRACT

Sustainability in healthcare, particularly within the domain of cardiac electrophysiology, assumes paramount importance for the near future. The escalating environmental constraints encountered necessitate a proactive approach. This position paper aims to raise awareness among physicians, spark critical inquiry and identify potential solutions to enhance the sustainability of our practice. Reprocessing of single-use medical devices has emerged as a potential solution to mitigate the environmental impact of electrophysiology procedures, while also offering economic advantages. However, reprocessing remains unauthorized in certain countries. In regions where it is possible, stringent regulatory standards must be adhered to, to ensure patient safety. It is essential that healthcare professionals, policymakers and manufacturers collaborate to drive innovation, explore sustainable practices and ensure that patient care remains uncompromised in the face of environmental challenges. Ambitious national/international programmes of disease prevention should be the cornerstone of the strategy. It is equally vital to implement immediate actions, as delineated in this position paper, to bring about tangible change quickly.


Subject(s)
Cardiology , Defibrillators, Implantable , Pacemaker, Artificial , Humans , Arrhythmias, Cardiac/therapy , Societies, Medical
7.
Heart Rhythm ; 2024 Jan 27.
Article in English | MEDLINE | ID: mdl-38286245

ABSTRACT

BACKGROUND: Differentiating between atypical atrioventricular nodal reentrant tachycardia (AVNRT) and orthodromic reciprocating tachycardia utilizing a septal accessory pathway is a complex challenge. OBJECTIVE: The purpose of this study was to describe the "local VA index," a straightforward method based on signals from the coronary sinus catheter, to distinguish between these arrhythmias during tachycardia and entrainment. The ventriculoatrial (VA) interval on the coronary sinus catheter is measured during tachycardia and entrainment, at the site of earliest atrial activity. The difference between these 2 situations defines the "local VA index." We also propose a mechanism to clarify the limitations of historical pacing maneuvers, such as postpacing interval minus tachycardia cycle length (PPI-TCL) and stimulus-atrial interval minus ventriculoatrial interval (SA-VA), by examining nodal decrement and intraventricular conduction delay. METHODS: In a retrospective study of 75 patients referred for supraventricular tachycardia evaluation, 37 were diagnosed with atrioventricular reentrant tachycardia (AVRT) with orthodromic reciprocating tachycardia, and 38 with AVNRT (27 typical, 11 atypical). RESULTS: In comparison to AVRT patients, AVNRT patients exhibited longer PPI-TCL (176 ± 47 ms vs 113 ± 42 ms; P <.01) and SA-VA (138 ± 47 ms vs 64 ± 28 ms; P <.01). The AVRT group had mean local VA index of -1 ± 13 ms, whereas the AVNRT group had a significantly longer index of 91 ± 46 ms (P <.01). An optimal threshold for differentiation was a local VA index of 40 ms. Importantly, there was no significant correlation between pacing cycle length and nodal decrement as well as intraventricular delay related to pathway location. This interindividual variability might explain misleading interpretations of PPI-TCL and SA-VA. CONCLUSION: This novel approach is advantageous because of its simplicity and effectiveness, requiring only 2 diagnostic catheters. A local VA interval difference <40 ms provides a clear distinction for AVRT.

8.
JACC Clin Electrophysiol ; 10(3): 502-511, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38206261

ABSTRACT

BACKGROUND: Desmoplakin (DSP) pathogenic variants are rare causes of arrhythmogenic cardiomyopathy and often involve the right and left ventricles. Ventricular tachycardia (VT) ablations may be required in these patients, but procedural characteristics have not been reported. OBJECTIVES: In this study, the authors sought to report a multicenter experience of VT ablation in patients with DSP pathogenic variants. METHODS: VT ablations performed in patients with known DSP pathogenic variants were analyzed across 6 centers in 3 countries. Patient characteristics and acute and long-term procedural outcomes were reported. RESULTS: A total of 20 patients (13 men, median age 43 years [Q1-Q3: 41.5-53.0 years], left ventricular ejection fraction 43.0% [Q1-Q3: 41.5%-53.0%], 11 previous failed ablations) were referred for VT ablation procedures. All patients had symptomatic VTs, with ICD therapy in 19 patients. Epicardial procedures were performed in 16 of the 20 patients. VT target sites were located in the right ventricular (RV) endocardium (n = 11), the RV epicardium (n = 4), the left ventricular (LV) endocardium (n = 2) and the LV epicardium (n = 7). In 3 patients, the VT target sites were in close proximity to coronary arteries, limiting ablation. During follow-up, VTs recurred in 11 patients, and repeated ablations were performed in 9 patients. Allowing for multiple procedures, 19 of the 20 patients remained free of VT recurrence after a median follow-up of 18 months [Q1-Q3: 5-60 months]. CONCLUSIONS: Patients with DSP cardiomyopathy often have biventricular involvement, and ablation procedures often require ablation in both ventricles and the epicardium. Recurrences are not uncommon, and the pathologic substrate can be located in close proximity to epicardial coronary arteries, limiting the success rate of ablations.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Catheter Ablation , Tachycardia, Ventricular , Male , Humans , Adult , Desmoplakins/genetics , Stroke Volume , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/surgery , Ventricular Function, Left , Cardiomyopathies/complications , Cardiomyopathies/surgery , Catheter Ablation/methods
9.
Article in English | MEDLINE | ID: mdl-38191005

ABSTRACT

Patients treated with cardiac stereotactic body radiation therapy (radioablation) for refractory ventricular arrhythmias are patients with advanced structural heart disease and significant comorbidities. However, data regarding 1-year mortality after the procedure are scarce. This systematic review and pooled analysis aimed at determining 1-year mortality after cardiac radioablation for refractory ventricular arrhythmias and investigating leading causes of death in this population. MEDLINE/EMBASE databases were searched up to January 2023 for studies including patients undergoing cardiac radioablation for the treatment of refractory ventricular arrhythmias. Quality of included trials was assessed using the NIH Tool for Case Series Studies (PROSPERO CRD42022379713). A total of 1,151 references were retrieved and evaluated for relevance. Data were extracted from 16 studies, with a total of 157 patients undergoing cardiac radioablation for refractory ventricular arrhythmias. Pooled 1-year mortality was 32 % (95 %CI: 23-41), with almost half of the deaths occurring within three months after treatment. Among the 157 patients, 46 died within the year following cardiac radioablation. Worsening heart failure appeared to be the leading cause of death (52 %), although non-cardiac mortality remained substantial (41 %) in this population. Age≥70yo was associated with a significantly higher 12-month all-cause mortality (p<0.022). Neither target volume size nor radiotherapy device appeared to be associated with 1-year mortality (p = 0.465 and p = 0.199, respectively). About one-third of patients undergoing cardiac stereotactic body radiation therapy for refractory ventricular arrhythmias die within the first year after the procedure. Worsening heart failure appears to be the leading cause of death in this population.

10.
Heart Rhythm ; 21(3): 313-320, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37956775

ABSTRACT

BACKGROUND: The efficacy of beta-blocker treatment in type 3 long QT syndrome (LQT3) remains debated. OBJECTIVES: The purpose of this study was to test the hypothesis that beta-blocker use is associated with cardiac events (CEs) in a French cohort of LQT3 patients. METHODS: All patients with a likely pathogenic/pathogenic variant in the SCN5A gene (linked to LQT3) were included and followed-up. Documented ventricular tachycardia/ventricular fibrillation, torsades de pointes, aborted cardiac arrest, sudden death, and appropriate shocks were considered as severe cardiac events (SCEs). CEs also included syncope. RESULTS: We included 147 patients from 54 families carrying 23 variants. Six of the patients developed symptoms before the age of 1 year and were analyzed separately. The 141 remaining patients (52.5% male; median age at diagnosis 24.0 years) were followed-up for a median of 11 years. The probabilities of a CE and an SCE from birth to the age of 40 were 20.5% and 9.9%, respectively. QTc prolongation (hazard ratio [HR] 1.12 [1.0-1.2]; P = .005]) and proband status (HR 4.07 [1.9-8.9]; P <.001) were independently associated with the occurrence of CEs. Proband status (HR 8.13 [1.7-38.8]; P = .009) was found to be independently associated with SCEs, whereas QTc prolongation (HR 1.11 [1.0-1.3]; P = .108) did not reach statistical significance. The cumulative probability of the age at first CE/SCE was not lower in patients treated with a beta-blocker. CONCLUSION: In agreement with the literature, proband status and lengthened QTc were associated with a higher risk of CEs. Our data do not show a protective effect of beta-blocker treatment.


Subject(s)
Heart Arrest , Long QT Syndrome , Humans , Male , Young Adult , Adult , Female , Electrocardiography , Long QT Syndrome/drug therapy , Long QT Syndrome/genetics , Long QT Syndrome/diagnosis , Syncope , Heart Arrest/complications , Adrenergic beta-Antagonists/therapeutic use
11.
Circ Arrhythm Electrophysiol ; 17(1): e012072, 2024 01.
Article in English | MEDLINE | ID: mdl-38099441

ABSTRACT

Although there is consensus on the management of patients with Brugada Syndrome with high risk for sudden cardiac arrest, asymptomatic or intermediate-risk patients present clinical management challenges. This document explores the management opinions of experts throughout the world for patients with Brugada Syndrome who do not fit guideline recommendations. Four real-world clinical scenarios were presented with commentary from small expert groups for each case. All authors voted on case-specific questions to evaluate the level of consensus among the entire group in nuanced diagnostic and management decisions relevant to each case. Points of agreement, points of controversy, and gaps in knowledge are highlighted.


Subject(s)
Brugada Syndrome , Heart Arrest , Humans , Brugada Syndrome/diagnosis , Brugada Syndrome/therapy , Electrocardiography , Heart Arrest/diagnosis , Heart Arrest/therapy , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Consensus
12.
JACC Clin Electrophysiol ; 9(12): 2507-2519, 2023 12.
Article in English | MEDLINE | ID: mdl-37804259

ABSTRACT

BACKGROUND: Electrophysiological mapping of ventricular tachycardia (VT) is tedious and poorly reproducible. Substrate analysis on imaging cannot explicitly display VT circuits. OBJECTIVES: This study sought to introduce a computed tomography-based model personalization approach, allowing for the simulation of postinfarction VT in a clinically compatible time frame. METHODS: In 10 patients (age 65 ± 11 years, 9 male) referred for post-VT ablation, computed tomography-derived wall thickness maps were registered to 25 electroanatomical maps (sinus rhythm, paced, and VT). The relationship between wall thickness and electrophysiological characteristics (activation-recovery interval) was analyzed. Wall thickness was then employed to parameterize a fast and tractable organ-scale wave propagation model. Pacing protocols were simulated from multiple sites to test VT induction in silico. In silico VTs were compared to VT circuits mapped clinically. RESULTS: Clinically, 6 different VTs could be induced with detailed maps in 9 patients. The proposed model allowed for fast simulation (median: 6 min/pacing site). Simulations of steady pacing (600 milliseconds) from 100 different sites/patient never triggered any arrhythmia. Applying S1-S2 or S1-S2-S3 induction schemes allowed for the induction of in silico VTs in the 9 of 10 patients who were clinically inducible. The patient who was not inducible clinically was also noninducible in silico. A total of 42 different VTs were simulated (4.2 ± 2 per patient). Six in silico VTs matched a VT circuit mapped clinically. CONCLUSIONS: The proposed framework allows for personalized simulations in a matter of hours. In 6 of 9 patients, simulations show re-entrant patterns matching intracardiac recordings.


Subject(s)
Tachycardia, Ventricular , Humans , Male , Middle Aged , Aged , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Tomography, X-Ray Computed
13.
Article in English | MEDLINE | ID: mdl-37783852

ABSTRACT

BACKGROUND: A novel method to measure atrial fibrillation cycle length (AF-CL) was recently described, based on the average of 10 consecutive signals (FARS10). FARS10 accurately identified pulmonary vein isolation (PVI)-responders among patients with persistent AF. Whether this method is applicable to patients with paroxysmal AF is unknown. OBJECTIVE: The aim of this study is to evaluate the prognostic value of FARS10 measurements in patients with paroxysmal AF. METHODS AND RESULTS: We enrolled paroxysmal AF patients undergoing PVI in a prospective multicenter study. After AF induction with a standardized protocol, the AF-CL was measured using FARS-10 method. The primary endpoint was AF/AT-recurrence. One-hundred and four patients were included (61 ± 14 years, 25% females). After a mean follow-up of 12 ± 4 months, AF/AT recurrence rate was 20%. The fastest PV CL (fPV-CL) was independently associated with the primary endpoint at multivariate analysis (HR 1.02, p < 0.001). Every 10 ms increase in fPV-CL, AF recurrences increased by 20%. The value of 160 ms was found to be the optimal cut-off (specificity 81%, sensitivity 76%). Patients with fPV-CL < 160 ms experienced lower AF recurrences as compared to patients with fPV-CL > 160 ms (8% vs. 32% at 1 year; HR = 0.17, p < 0.001). Progression to persistent AF was observed in 13% of patients with fPV-CL > 160 ms. CONCLUSION: fPV-CL measured with the FARS-10 method accurately predicts PVI success in paroxysmal AF patients undergoing PVI. Patients with slow PV activity (fPV-CL > 160 ms) experience higher AF recurrence rate after PVI and more frequent progression to persistent AF. In 104 patients with paroxysmal atrial fibrillation (AF) undergoing AF ablation, AF was induced at the beginning of the procedure. Pulmonary vein activity was measured using FARS10 measurement (10 consecutive fastest atrial repetitive similar morphology signals). The value of 160 ms was found to be the best cut-off to discriminate outcomes. At 1-year follow-up, patients with fast veins (< 160 ms) experienced significantly fewer AF recurrences as compared to patients with slow veins (> 160 ms). PV activity measured with FARS10 method accurately discriminates pulmonary vein isolation responders, in patients with paroxysmal AF. ABBREVIATIONS: AF atrial fibrillation, AT atrial tachycardia, CL cycle length, FARS10: 10 consecutive fastest atrial repetitive similar morphology signal, fPV fastest pulmonary vein, HR hazard ratio, ms milliseconds.

14.
Circulation ; 148(25): 2029-2037, 2023 12 19.
Article in English | MEDLINE | ID: mdl-37886885

ABSTRACT

BACKGROUND: In severely affected patients with catecholaminergic polymorphic ventricular tachycardia, beta-blockers are often insufficiently protective. The purpose of this study was to evaluate whether flecainide is associated with a lower incidence of arrhythmic events (AEs) when added to beta-blockers in a large cohort of patients with catecholaminergic polymorphic ventricular tachycardia. METHODS: From 2 international registries, this multicenter case cross-over study included patients with a clinical or genetic diagnosis of catecholaminergic polymorphic ventricular tachycardia in whom flecainide was added to beta-blocker therapy. The study period was defined as the period in which background therapy (ie, beta-blocker type [beta1-selective or nonselective]), left cardiac sympathetic denervation, and implantable cardioverter defibrillator treatment status, remained unchanged within individual patients and was divided into pre-flecainide and on-flecainide periods. The primary end point was AEs, defined as sudden cardiac death, sudden cardiac arrest, appropriate implantable cardioverter defibrillator shock, and arrhythmic syncope. The association of flecainide with AE rates was assessed using a generalized linear mixed model assuming negative binomial distribution and random effects for patients. RESULTS: A total of 247 patients (123 [50%] females; median age at start of flecainide, 18 years [interquartile range, 14-29]; median flecainide dose, 2.2 mg/kg per day [interquartile range, 1.7-3.1]) were included. At baseline, all patients used a beta-blocker, 70 (28%) had an implantable cardioverter defibrillator, and 21 (9%) had a left cardiac sympathetic denervation. During a median pre-flecainide follow-up of 2.1 years (interquartile range, 0.4-7.2), 41 patients (17%) experienced 58 AEs (annual event rate, 5.6%). During a median on-flecainide follow-up of 2.9 years (interquartile range, 1.0-6.0), 23 patients (9%) experienced 38 AEs (annual event rate, 4.0%). There were significantly fewer AEs after initiation of flecainide (incidence rate ratio, 0.55 [95% CI, 0.38-0.83]; P=0.007). Among patients who were symptomatic before diagnosis or during the pre-flecainide period (n=167), flecainide was associated with significantly fewer AEs (incidence rate ratio, 0.49 [95% CI, 0.31-0.77]; P=0.002). Among patients with ≥1 AE on beta-blocker therapy (n=41), adding flecainide was also associated with significantly fewer AEs (incidence rate ratio, 0.25 [95% CI, 0.14-0.45]; P<0.001). CONCLUSIONS: For patients with catecholaminergic polymorphic ventricular tachycardia, adding flecainide to beta-blocker therapy was associated with a lower incidence of AEs in the overall cohort, in symptomatic patients, and particularly in patients with breakthrough AEs while on beta-blocker therapy.


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Female , Humans , Adolescent , Male , Flecainide/adverse effects , Incidence , Cross-Over Studies , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/drug therapy , Tachycardia, Ventricular/epidemiology , Adrenergic beta-Antagonists/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control
15.
Front Cardiovasc Med ; 10: 1267800, 2023.
Article in English | MEDLINE | ID: mdl-37799779

ABSTRACT

Background: Stereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR. Methods: Delineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient. Results: Ten electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02-0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52-1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51-1.55 cm, Dice-coefficient mean: 0.31 ± 0.21). Conclusions: Interobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation.

16.
Circ Arrhythm Electrophysiol ; 16(10): e012241, 2023 10.
Article in English | MEDLINE | ID: mdl-37728002

ABSTRACT

BACKGROUND: Abnormal atrial potentials (AAPs) recorded during sinus rhythm/atrial pacing may indicate areas of slow conduction capable of supporting reentrant atrial tachycardia (AT). Therefore, we sought to examine the relationship between AAPs and AT circuits. METHODS: One hundred twenty-three reentrant ATs in 104 patients were analyzed. AAPs, consisting of fragmented potentials and split potentials, were assessed using the Rhythmia LUMIPOINT algorithm. RESULTS: There was 93±13% overlap between areas with AAPs during sinus rhythm/atrial pacing and areas of slow conduction along the reentry circuit during AT. The cumulative area of AAPs was smaller in patients with localized-reentrant ATs compared with anatomic macro-reentrant ATs (20.0 [14.6-30.5] versus 28.9 [21.8-35.6] cm2; P=0.021). Patients with perimitral ATs had larger areas of AAPs on the lateral wall whereas patients with roof-dependent ATs had larger areas of AAPs on the roof and posterior wall (P≤0.018 for all comparisons). The patchy scar that was associated with localized-reentrant AT exhibited a larger area of AAPs at its periphery than the scar that did not participate in localized-reentrant AT (3.1 [2.4-4.5] versus 1.0 [0.7-1.6] cm2; P<0.001). CONCLUSIONS: AAPs recorded during sinus rhythm/atrial pacing are associated with areas of slow conduction during reentrant AT. The burden and distribution of AAPs may provide actionable insights into AT circuit features, including in cases in which ATs are difficult to map.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Cicatrix , Heart Atria , Heart Rate , Cardiac Pacing, Artificial
17.
JACC Clin Electrophysiol ; 9(10): 2054-2066, 2023 10.
Article in English | MEDLINE | ID: mdl-37715740

ABSTRACT

BACKGROUND: Substrate abnormalities can alter atrial activation during atrial tachycardias (ATs) thereby influencing AT-wave morphology on the surface electrocardiogram. OBJECTIVES: This study sought to identify determinants of isoelectric intervals during ATs with complex atrial activation patterns. METHODS: High-density activation maps of 126 ATs were studied. To assess the impact of the activated atrial surface on the presence of isoelectric intervals, this study measured the minimum activated area throughout the AT cycle, defined as the smallest activated area within a 50-millisecond period, by using signal processing algorithms (LUMIPOINT). RESULTS: ATs with isoelectric intervals (P-wave ATs) included 23 macro-re-entrant ATs (40%), 26 localized-re-entrant ATs (46%), and 8 focal ATs (14%), whereas those without included 46 macro-re-entrant ATs (67%), 21 localized-re-entrant ATs (30%), and 2 focal ATs (3%). Multivariable regression identified smaller minimum activated area and larger very low voltage area as independent predictors of P-wave ATs (OR: 0.732; 95% CI: 0.644-0.831; P < 0.001; and OR: 1.042; 95% CI: 1.006-1.080; P = 0.023, respectively). The minimum activated area with the cutoff value of 10 cm2 provided the highest predictive accuracy for P-wave ATs with sensitivity, specificity, and positive and negative predictive values of 96%, 97%, 97%, and 95%, respectively. In re-entrant ATs, smaller minimum activated area was associated with lower minimum conduction velocity within the circuit and fewer areas of delayed conduction outside of the circuit (standardized ß: 0.524; 95% CI: 0.373-0.675; P < 0.001; and standardized ß: 0.353; 95% CI: 0.198-0.508; P < 0.001, respectively). CONCLUSIONS: Reduced atrial activation area and voltage were associated with isoelectric intervals during ATs.


Subject(s)
Catheter Ablation , Tachycardia, Supraventricular , Tachycardia, Ventricular , Humans , Electrophysiologic Techniques, Cardiac , Heart Rate , Electrocardiography
18.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Article in English | MEDLINE | ID: mdl-37558371

ABSTRACT

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Subject(s)
Defibrillators, Implantable , Heart Defects, Congenital , Transposition of Great Vessels , Humans , Female , Young Adult , Adult , Middle Aged , Defibrillators, Implantable/adverse effects , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Cohort Studies , Treatment Outcome , Retrospective Studies , Heart Defects, Congenital/complications , Heart Defects, Congenital/therapy
20.
Heart Rhythm ; 20(10): 1370-1377, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37414109

ABSTRACT

BACKGROUND: Omnipolar technology (OT) was recently proposed to generate electroanatomic voltage maps with orientation-independent electrograms. We describe the first cohort of patients undergoing ventricular tachycardia (VT) ablation guided by OT. OBJECTIVE: The purpose of this study was to compare omnipolar and bipolar high-density maps with regard to voltage amplitude, late potential (LP) annotation, and isochronal late activation mapping distribution. METHODS: A total of 24 patients (16 [66%] ischemic cardiomyopathy and 12 [50%] redo cases) underwent VT ablation under OT guidance. Twenty-seven sinus rhythm substrate maps and 10 VT activation maps were analyzed. Omnipolar and bipolar (HD Wave Solution algorithm, Abbott, Abbott Park, IL) voltages were compared. Areas of LPs were correlated with the VT isthmus areas, and late electrogram misannotation was evaluated. Deceleration zones based on isochronal late activation maps were analyzed by 2 blinded operators and compared to the VT isthmuses. RESULTS: OT maps had higher point density (13.8 points/cm2 vs 8.0 points/cm2). Omnipolar points had 7.1% higher voltages than bipolar points within areas of dense scar and border zone. The number of misannotated points was significantly lower for OT maps (6.8% vs 21.9%; P = .01), showing comparable sensitivity (53% vs 59%) but higher specificity (79% vs 63%). The sensitivity and specificity of detection of the VT isthmus in the deceleration zones were, respectively, 75% and 65% for OT and 35% and 55% for bipolar mapping. At 8.4 months, 71% freedom from VT recurrence was achieved. CONCLUSION: OT is a valuable tool for guiding VT ablation, providing more accurate identification of LPs and isochronal crowding due to slightly higher voltages.