Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
J Infect Chemother ; 29(9): 838-842, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37178974

ABSTRACT

BACKGROUND: In blood cultures that test positive for staphylococcal bacteria, rapid identification of methicillin-resistant Staphylococcus aureus (MRSA) or methicillin-susceptible Staphylococcus aureus (MSSA) by molecular assay is useful for appropriate antimicrobial treatment of bloodstream infections. Although the Xpert MRSA/SA BC assay is widely available in clinical settings in Japan, its efficacy has not yet evaluated thoroughly. METHODS: We retrospectively studied 100 blood culture cases positive for S. aureus at Sapporo Medical University Hospital between March 2019 and May 2022. Cycle threshold (CT) values for target genes from the Xpert MRSA/SA BC assay were compared to phenotypic results. Genotyping and genetic analysis of the orfX-SCCmec junction region was performed for selected isolates. RESULTS: We analyzed 25 and 75 isolates assigned to MRSA and MSSA, respectively, using the Xpert MRSA/SA BC assay. Of these, 99 isolates from agar cultures showed compatible susceptibility to oxacillin. One genetically misidentified case of MRSA was found to be caused by the mixed growth of MSSA and methicillin-resistant S. hominis on agar culture. Of the 73 MSSA with pure growth on agar culture, 45 (61.6%) were found to be orfX-SCCmec-positive, spa-positive, and mecA-negative in this assay. These MSSA belong to diverse spa and coa types. CONCLUSION: The Xpert MRSA/SA BC assay accurately identified MRSA and MSSA in positive blood cultures. However, over half of the MSSA isolates showed positive results for orfX-SCCmec, presumably due to genetic diversity in the orfX-associated region of MSSA. Therefore, the coexistence of MSSA and mecA-harboring coagulase-negative staphylococci may cause confusion about identification of MRSA.


Subject(s)
Methicillin-Resistant Staphylococcus aureus , Staphylococcal Infections , Humans , Methicillin-Resistant Staphylococcus aureus/genetics , Methicillin/pharmacology , Methicillin/therapeutic use , Staphylococcus aureus/genetics , Blood Culture , Agar , Pathology, Molecular , Retrospective Studies , Staphylococcal Infections/diagnosis , Staphylococcal Infections/microbiology , Staphylococcus , Microbial Sensitivity Tests , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use
2.
J Infect Chemother ; 29(8): 764-768, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37100241

ABSTRACT

INTRODUCTION: Gram staining is a convenient method for bacterial estimation. Urine culture is typically used to diagnose urinary tract infections. Therefore, urine culture is also performed on Gram stain-negative urine specimens. However, the frequency of uropathogen identification in these samples remains unclear. METHODS: From 2016 to 2019, we retrospectively compared the results of Gram staining and urine culture tests on midstream urine specimens submitted for the diagnosis of urinary tract infections to confirm the significance of urine culture on Gram stain-negative specimens. Analysis was performed according to the patients' sex and age, and the frequency of uropathogen identification in the culture was examined. RESULTS: A total of 1763 urine specimens (women, 931; men, 832) were collected. Of these, 448 (25.4%) were not positive on Gram staining but were positive on culture. In specimens without bacteria on Gram staining, the frequencies of specimens with uropathogens detected on culture were 20.8% (22/106) in women aged <50 years, 21.4% (71/332) in women aged ≥50 years, 2.0% (2/99) in men aged <50 years, and 7.8% (39/499) in men aged ≥50 years. CONCLUSIONS: In men aged <50 years, the frequency of uropathogenic bacteria identification by urine culture was low in Gram stain-negative specimens. Therefore, urine cultures may be excluded from this group. In contrast, in women, a small number of Gram stain-negative specimens showed significant culture results for the diagnosis of urinary tract infection. Therefore, urine culture should not be omitted in women without careful consideration.


Subject(s)
Urinalysis , Urinary Tract Infections , Male , Humans , Female , Retrospective Studies , Urinalysis/methods , Urinary Tract Infections/drug therapy , Bacteria , Staining and Labeling , Urine/microbiology
3.
J Infect Chemother ; 29(2): 157-162, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36288777

ABSTRACT

INTRODUCTION: Early diagnosis and appropriate infection control are important to prevent the transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this study, we aimed to assess the diagnostic performance of SARS-CoV-2 rapid antigen detection (RAD) tests and the factors that cause nonspecific reactions. METHODS: Nasopharyngeal swab specimens (n = 100), sputum specimens (n = 10), and lithium-heparin plasma samples (n = 100) were collected. We evaluated Espline®SARS-CoV-2 (Espline) and SARS-CoV-2 Rapid Antigen Test that also known as STANDARD Q® (STANDARD Q), with reverse transcription-polymerase chain reaction (RT-PCR) and Lumipulse® Presto SARS-CoV-2 Ag as reference tests. In addition, we investigated the effects of inadequate pretreatment methods and five potential causes of nonspecific reactions. RESULTS: The sensitivities of Espline and STANDARD Q were 60% and 57%, respectively, and their specificity was 100%. It was confirmed that the judgment line for the positive insufficiently mixed specimens was faint. A false-positive result was observed with STANDARD Q when sputum was used as a specimen to investigate judgment the effect of viscosity. CONCLUSIONS: Espline and STANDARD Q show good sensitivity for specimens with Ct values less than 25, but specimens collected within 9 days of symptom onset may still give false negatives. The test should be performed carefully, and the results should be judged comprehensively, taking into account clinical symptoms and patient background.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19 Testing , Clinical Laboratory Techniques/methods , Sensitivity and Specificity
4.
J Infect Chemother ; 28(11): 1590-1593, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35953013

ABSTRACT

INTRODUCTION: Compared to nasopharyngeal swabs (NPS), there has been insufficient evaluation of the diagnostic performance of nasal swabs (NS) for the detection of severe acute respiratory coronavirus 2 (SARS-CoV-2) in the nucleic acid amplification test (NAAT) and quantitative SARS-CoV-2 antigen test (QAT). METHODS: We prospectively compared healthcare worker-collected and flocked NS within nine days after symptom onset to paired NPS to detect SARS-CoV-2 in NAAT and QAT on the fully automated Lumipulse system. The agreement between sample types was evaluated, and cycle threshold (Ct) values and antigen levels were used as surrogate viral load measures. RESULTS: Sixty sets of NPS and NS samples were collected from 40 patients with COVID-19. The overall agreements between NAAT and QAT samples were 76.7% and 65.0%, respectively. In NAAT, the Ct value of NS was significantly higher, 5.9, than that of NPS. Thirty-nine (95.1%) NS tested positive in 41 positive-paired NPS with Ct ≤ 30. The negative correlation was observed between antigen levels of NS in QAT and Ct values of NS in NAAT (r = -0.88). In QAT, the antigen level of NS was significantly lower than that of NPS. Thirty-six (90.0%) NS tested positive in 40 positive-paired NPS with antigen levels >100 pg/mL, which were collected significantly earlier than those with antigen levels ≤100 pg/mL. CONCLUSIONS: In NAAT and QAT, NS had limited performance in detecting SARS-CoV-2 compared to NPS. However, NS may be helpful for patients with COVID-19 with high viral loads or those in the early stages of the illness.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Humans , Nasopharynx , Nucleic Acid Amplification Techniques , SARS-CoV-2/genetics , Sensitivity and Specificity , Serologic Tests , Viral Load
5.
J Infect Chemother ; 28(7): 1033-1036, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35428574

ABSTRACT

INTRODUCTION: This study aimed to evaluate rapid antigen detection (RAD) and rapid nucleic acid amplification tests (NAATs) to detect influenza virus (IV). METHODS: The conventional RAD test (Quick Chaser Flu A, B: QC), using silver amplified immunochromatography (Quick Chaser Auto Flu A, B: QCA), as well as two NAATs (Xpert Xpress Flu/RSV: Xpert, cobas Influenza A/B & RSV: cobas) were evaluated using nasopharyngeal swabs from suspected cases of influenza. A reference method was performed using real-time reverse transcription polymerase chain reaction according to the manual of the Japanese National Institute of Infectious Disease (NIID). RESULTS: From a total of 177 samples, 51 were positive according to the NIID assay. The kappa (κ) coefficient in Xpert and cobas for influenza A virus (IAV)/influenza B virus (IBV) was 1.00, which was the highest among the four detection assays. However, the κ coefficients in QC and QCA for IAV/IBV were 0.71-0.77 and 0.87-0.89, respectively. The sensitivities of the RAD tests were 41.7% in QC and 50.0% in QCA at < 6 h after onset, and 100.0% in both QC and QCA at 24-48 h after onset. The cycle threshold (Ct) values were significantly lower in the group in which all detection assays were positive for IAV. CONCLUSIONS: Xpert and cobas have comparable analytical performances and are highly useful as influenza virus detection assays. QC and QCA could show false negatives frequently in the early stage of infection and when viral load is low.


Subject(s)
Influenza A virus , Influenza, Human , Humans , Influenza A virus/genetics , Influenza B virus/genetics , Influenza, Human/diagnosis , Molecular Diagnostic Techniques/methods , Nasopharynx , Nucleic Acid Amplification Techniques/methods , Sensitivity and Specificity
6.
J Infect Chemother ; 28(7): 1012-1014, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35339382

ABSTRACT

We evaluated the optimal timing of saliva sample collection to diagnose the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. We obtained 150 saliva samples at four specific time points from 13 patients with confirmed SARS-CoV-2 infection. The time points were (1) early morning (immediately after waking), (2) immediately after breakfast before tooth brushing, (3) 2 h after breakfast, and (4) before lunch. On the 2nd hospital day, patients collected saliva at the four time points by themselves. We collected samples at two time points, (1) and (3), from the 3rd hospital day to day 9 following symptom onset. In 52 samples collected at the four time points, there was no significant difference. Meanwhile, there was no significant difference in the positive proportion or the viral load between the two time points in both analyses by the day from symptom onset and by all samples. In this study, there was no difference in the positive proportions in saliva collected at various time points within 9 days after symptom onset. The timing of saliva collection was not affected by the diagnosis of SARS-CoV-2 infection.


Subject(s)
COVID-19 , COVID-19/diagnosis , COVID-19 Testing , Humans , Nasopharynx , SARS-CoV-2 , Saliva , Specimen Handling
7.
J Infect Chemother ; 27(10): 1477-1481, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34238663

ABSTRACT

INTRODUCTION: Highly sensitive reagents for detecting SARS-CoV-2 antigens have been developed for accurate and rapid diagnosis till date. In this study, we aim to clarify the frequency of false-positive reactions and reveal their details in SARS-CoV-2 quantitative antigen test using an automated laboratory device. METHODS: Nasopharyngeal swab samples (n = 4992) and saliva samples (n = 5430) were collected. We measured their SARS-CoV-2 antigen using Lumipulse® Presto SARS-CoV-2 Ag and performed a nucleic acid amplification test (NAAT) using the Ampdirect™ 2019 Novel Coronavirus Detection Kit as needed. The results obtained from each detection test were compared accordingly. RESULTS: There were 304 nasopharyngeal samples and 114 saliva samples were positive in the Lumipulse® Presto SARS-CoV-2 Ag test. All positive nasopharyngeal samples in the antigen test were also positive for NAAT. In contrast, only three (2.6%) of all the positive saliva samples in the antigen test were negative for NAAT. One showed no linearity with a dilute solution in the dilution test. Additionally, the quantitative antigen levels of all the three samples did not decrease after reaction with the anti-SARS-CoV-2 antibody. CONCLUSIONS: The judgment difference between the quantitative antigen test and NAAT seemed to be caused by non-specific reactions in the antigen test. Although the high positive and negative predictive value of this quantitative antigen test could be confirmed, we should consider the possibility of false-positives caused by non-specific reactions and understand the characteristics of antigen testing. We recommend that repeating centrifugation before measurement, especially in saliva samples, should be performed appropriately.


Subject(s)
COVID-19 , SARS-CoV-2 , False Positive Reactions , Humans , Nasopharynx , Saliva , Sensitivity and Specificity
8.
J Infect Chemother ; 27(7): 1115-1118, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33814351

ABSTRACT

INTRODUCTION: Norovirus is highly contagious, and a few particles of this virus are sufficient to make people sick. It is desirable to develop quick and accurate laboratory methods to detect norovirus. METHODS: We evaluated two commercial molecular diagnostic assays, the Xpert Norovirus and the TRCReady NV, using clinical fecal samples. A reference method was performed using in-house real-time reverse transcriptase polymerase chain reaction (real-time RT-PCR). RESULTS: The results of the real-time RT-PCR analysis of 60 suspected cases of norovirus infection showed 5 cases of Genogroup I (GI) positives and 21 cases of GII positives, among which was 1 GI and GII coinfection. The viral titers of the norovirus-positive samples ranged from 1.54 × 101 to 3.14 × 108 copies/µL. Norovirus GII.17 (12 cases, 48%) was the most frequently detected genotype in this study, followed by GII.4 (6 cases, 24%), GII.13 (2 cases, 8%), GI.2 (2 cases, 8%), GI.3 (2 cases, 8%), GI.1 (1 case, 4%), and GII.2 (1 case, 4%). The kappa coefficient was 1.000 (95% CI: 1.000-1.000) for Xpert Norovirus and 0.966 (95% CI: 0.896-1.000) for TRCReady NV, indicating a strong agreement. CONCLUSIONS: Norovirus detection using Xpert Norovirus and TRCReady NV is highly useful for diagnosis and infection control because these assays are easy to operate, quick, and exhibit almost the same performance as that of real-time RT-PCR.


Subject(s)
Caliciviridae Infections , Norovirus , Caliciviridae Infections/diagnosis , Feces , Genotype , Humans , Norovirus/genetics , Pathology, Molecular , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction , Reverse Transcriptase Polymerase Chain Reaction
9.
J Infect Chemother ; 26(1): 38-42, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31362903

ABSTRACT

Escherichia coli (E. coli) causes urinary tract infections, pneumonia, surgical site infections, and bloodstream infections and is the important pathogen for both community-acquired and healthcare-associated infections. To investigate the clonality of E. coli is important for infection control and prevention. We aimed to investigate the clonality of clinical E. coli isolates using Cica Geneus E. coli polymerase chain reaction (PCR)-based open-reading frame typing (POT) KIT and clarify the clinical usefulness of this kit. About 124 E. coli isolates obtained from inpatients at Sapporo Medical University Hospital were used. The POT method was used to classify 124 clinical isolates into 87 POT numbers. In addition to the clonality, it was possible to obtain additional information that 20 of the 124 isolates were extended-spectrum ß-lactamase (ESBL) producing E. coli (5 isolates of CTX-M-1 group and 15 isolates of CTX-M-9 group) and 13 were sequence type (ST) 131 clone. Furthermore, when these ESBL-producing 20 isolates were compared with pulsed-field gel electrophoresis (PFGE) or multilocus sequence typing (MLST), Simpson's index of diversity was 0.968 in POT method, 0.979 in PFGE, and 0.584 in MLST. POT method had an analytical power similar to that of PFGE. In conclusion, attention should be paid to the difference in the interpretation of the results between the POT method and the PFGE, but POT method may be useful to timely monitor the spread of E. coli in medical facilities.


Subject(s)
Escherichia coli Infections/microbiology , Escherichia coli/genetics , Open Reading Frames/genetics , Polymerase Chain Reaction/methods , Cross Infection , Electrophoresis, Gel, Pulsed-Field/methods , Escherichia coli/classification , Genes, Bacterial/genetics , Humans , Multilocus Sequence Typing/methods
10.
J Infect Chemother ; 24(3): 212-215, 2018 Mar.
Article in English | MEDLINE | ID: mdl-29198902

ABSTRACT

The existence of a cefazolin inoculum effect (InE) of methicillin-susceptible Staphylococcus aureus (MSSA), which is speculated to be a reason for cefazolin treatment failure in MSSA infections, is controversial. In Japan, although cefazolin is one of the therapeutic choices for patients with MSSA infection, there are few reports of this effect. Additionally, the association between InE and blaZ type in beta-lactams other than cefazolin has not been well documented. In this study, we confirmed an MSSA InE in several beta-lactams, including cefazolin, and its relationship with blaZ, using 52 MSSA isolates from blood cultures. Three isolates (5.8%) that possessed type A blaZ showed a pronounced cefazolin InE. Five isolates (9.6%) showed pronounced InE with sulbactam/ampicillin; four isolates had type C blaZ and one had type A blaZ. However, we confirmed InE in MSSA isolates with blaZ not only type A and C but also B and D. For cefotaxime, ceftriaxone, imipenem, and meropenem, regardless of the presence of blaZ, we did not observe a significant increase in MICs at a high inoculum of MSSA. Hence, our results suggest that the above four beta-lactams are good alternatives to cefazolin if InE leads to treatment failure in a patient.


Subject(s)
Anti-Bacterial Agents/pharmacology , Cefazolin/pharmacology , Methicillin/pharmacology , Staphylococcal Infections/microbiology , Staphylococcus aureus/drug effects , Genotype , Humans , Japan , Microbial Sensitivity Tests , Staphylococcus aureus/classification , Staphylococcus aureus/genetics , Staphylococcus aureus/isolation & purification , Treatment Failure , beta-Lactamases/genetics
11.
Int J Oncol ; 35(3): 511-5, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19639171

ABSTRACT

Target molecules for a highly sensitive and specific diagnosis of breast cancer in its early clinical stages have not yet been identified. Here, we show the first evidence for diagnostic performance of the molecule B cell-specific Moloney murine leukemia virus integration site 1 (Bmi-1) in breast cancer patients. Only 5 out of 46 non-cancerous samples were positive for Bmi-1 mRNA expression resulting in a sensitivity and specificity of 72.0 and 91.3%, respectively. The mRNA expression was estimated using the cut-off value obtained from the receiver operating characteristic curve analysis. Further, Bmi-1 mRNA expression was found to be elevated in 97.8% (45/46) of cancerous tissues in comparison to the expression in paired cancerous tissues and non-cancerous tissues obtained from identical patients. Bmi-1 mRNA was found to be highly expressed even in the early clinical stages of breast cancer. Our results suggest that Bmi-1 mRNA might be a new tool to support the diagnosis of breast cancers, irrespective of the clinical stage.


Subject(s)
Biomarkers, Tumor/analysis , Breast Neoplasms/genetics , Breast Neoplasms/pathology , Gene Expression , Nuclear Proteins/genetics , Proto-Oncogene Proteins/genetics , Repressor Proteins/genetics , Female , Humans , Immunohistochemistry , Nuclear Proteins/biosynthesis , Polycomb Repressive Complex 1 , Proto-Oncogene Proteins/biosynthesis , RNA, Messenger/analysis , ROC Curve , Repressor Proteins/biosynthesis , Reverse Transcriptase Polymerase Chain Reaction , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...