Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Bioengineering (Basel) ; 10(6)2023 Jun 20.
Article in English | MEDLINE | ID: mdl-37370674

ABSTRACT

Chronic otitis media is often connected to Eustachian tube dysfunction. As successful treatment cannot be guaranteed with the currently available options, the aim is to develop a stent for the Eustachian tube (ET). Over the course of this development, different prototypes were generated and tested in ex vivo experiments. Four different prototypes of an ET stent and one commercially available coronary stent were implanted in the ET of seven human donor bodies. The position of the stents was verified by cone beam CT. The implanted ETs were harvested, embedded in resin and ground at 200 µm steps. Resulting images of the single steps were used to generate 3D models. The 3D models were then evaluated regarding position of the stent in the ET, its diameters, amount of squeezing, orientation of the axes and other parameters. Virtual reconstruction of the implanted ET was successful in all cases and revealed one incorrect stent placement. The cross-section increased for all metal stents in direction from the isthmus towards the pharyngeal orifice of the ET. Depending on the individual design of the metal stents (open or closed design), the shape varied also between different positions along a single stent. In contrast, the cross-section area and shape remained constant along the polymeric prototype. With the current investigation, insight into the behavior of different prototypes of ET stents was gained, which can help in defining the specifications for the intended ET stent.

2.
Anat Cell Biol ; 54(1): 25-34, 2021 03 31.
Article in English | MEDLINE | ID: mdl-33583827

ABSTRACT

The vertebral trabecular bone has a complex three-dimensional microstructure with an inhomogeneous morphology. Correct identification and assessment of the weakest segments of the cancellous bone may lead to better prediction of fracture risk. The aim of this study was to compare cancellous bone from 240 vertebrae of the cervical, thoracic and lumbar spine of ten body donors with osteoporosis in regard to bone volume fraction (BVF), trabecular thickness, separation, trabecular number and degree of anisotropy, to ascertain why cervical vertebrae rarely fracture, even with severe osteoporosis. Samples were obtained from all vertebrae with a Jamshidi needle (8 Gauge). The investigations were performed with a micro-computed tomography (micro-CT) device (SKYSCAN 1172, RJL Micro & Analytic GmbH, Karlsdorf-Neuthard, Germany). Existing vertebral fractures and the bone mineral density of the lumbar spine were assessed with quantitative CT. Regarding the micro-CT parameters, statistically significant differences were observed between the various sections of the spine. We found a higher BVF, trabecular number and trabecular thickness, as well as a lower trabecular separation of the cervical vertebrae compared to other vertebrae. In addition, the degree of anisotropy in the cervical spine is lower than in the other spinal column sections. These results are age and sex dependent. Thus, the cervical spine has special structural features, whose causes must be determined in further investigations.

SELECTION OF CITATIONS
SEARCH DETAIL
...