Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters











Publication year range
1.
Opt Lett ; 48(20): 5273-5276, 2023 Oct 15.
Article in English | MEDLINE | ID: mdl-37831845

ABSTRACT

Optical scanning holography (OSH) can be applied to 3D fluorescent imaging. However, the optical setup for OSH is complicated due to the requirement of a phase shifter, a 2D mechanical scanner, and an interferometer. Although motionless optical scanning holography (MOSH) can overcome the problem, quantitative phase imaging (QPI) has not yet been realized because MOSH can only obtain incoherent holograms. If QPI in MOSH is realized, MOSH can be applied to various applications. In this Letter, MOSH-based QPI (MOSH-QPI) is proposed. In addition, a simple description of a coherent mode of OSH is presented. In the proof-of-principle experiment, the spatially divided phase-shifting technique is applied to reduce the number of measurements. The feasibility of MOSH-QPI is confirmed by measuring a phase distribution of a microlens array. MOSH-QPI is also applied to measure practical samples, and its results are compared with the experimental results of the conventional one using a Mach-Zehnder interferometer.

2.
Opt Express ; 30(11): 18134-18144, 2022 May 23.
Article in English | MEDLINE | ID: mdl-36221620

ABSTRACT

Common-path off-axis single-pixel holographic imaging (COSHI) is proposed to obtain complex amplitude information using an in-line interferometer and a single-pixel (point-like) detector. COSHI is more robust to disturbances such as vibration than the conventional single-pixel digital holography technique because of its common-path configuration. In addition, the number of measurements can be reduced due to COSHI's reconstruction process based on the Fourier fringe analysis. In COSHI, an off-axis digital hologram can be obtained using the structured patterns composed of Hadamard basis patterns and stationary tilted phase distribution. Interestingly, COSHI's space bandwidth is larger than of the conventional off-axis digital holography because COSHI does not reconstruct the self-correlation term of an object. The proposed method is theoretically confirmed and numerical and experimental results show its feasibility.

3.
Appl Opt ; 61(5): 1106-1111, 2022 Feb 10.
Article in English | MEDLINE | ID: mdl-35201161

ABSTRACT

Commercially available hyperspectral cameras are useful for remote sensing, but in most cases snapshot imaging is difficult due to the need for scanning. The coded aperture snapshot spectral imager (CASSI) has been proposed to simultaneously acquire a target scene's spatial and spectral dimensional data, employing a refractive prism as a disperser. This paper proposes a CASSI-based technique using a generally available diffraction grating of a Ronchi ruling and blazed grating and its improvement using the undispersed zeroth-order light. The feasibility and performance of the proposed technique are experimentally validated, and the grating parameters are identified.

4.
Appl Opt ; 60(28): 8802-8808, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-34613106

ABSTRACT

Single-shot higher-order transport-of-intensity quantitative phase imaging (SHOT-QPI) is proposed to realize simple, in-line, scanless, and single-shot QPI. However, the light-use efficiency of SHOT-QPI is low because of the use of an amplitude-type computer-generated hologram (CGH). Although a phase-type CGH overcomes the problem, the accuracy of the measured phase is degraded owing to distortion of the defocused intensity distributions, which is caused by a quantization error of the CGH. Alternative SHOT-QPI with the help of deep learning, termed Deep-SHOT, is proposed to solve a nonlinear problem between the distorted intensities and the phase. In Deep-SHOT, a neural network learns the relationship between a series of distorted intensity distributions and the ground truth phase distribution. Because the distortion of intensity distributions is intrinsic to an optical system, the neural network is optimized for the system, and the proposed method improves the accuracy of the measured phase. The results of a proof-of-principle experiment indicate that the use of multiple defocused intensities also improves accuracy, even the nonlinear problem.

5.
Opt Lett ; 46(12): 2920-2923, 2021 Jun 15.
Article in English | MEDLINE | ID: mdl-34129574

ABSTRACT

An unconventional angular-multiplexed recording technique is proposed for holographic data storage based on a computer-generated hologram (CGH) technique. While general angular-multiplexed recording techniques require a Mach-Zehnder interferometer to record data pages as volume holograms, the proposed method records ones with a common-path configuration with the help of a CGH technique, which prevents the optical setup from being bulky. In the proposed method, the CGH reconstructs signal and reference beams simultaneously, and these beams interfere in a recording medium. By changing the diffraction angle of the reference beam from the CGH, angular multiplexing is accomplished with a common-path optical setup without additional optical elements. Multiplexed recording of four data pages is demonstrated in a proof-of-principle experiment, which indicates the feasibility of the proposed method.

6.
Opt Express ; 29(4): 4783-4801, 2021 Feb 15.
Article in English | MEDLINE | ID: mdl-33726027

ABSTRACT

The imaging quality of quantitative phase imaging (QPI) based on the transport of intensity equation (TIE) can be improved using a higher-order approximation for defocused intensity distributions. However, this requires mechanically scanning an image sensor or object along the optical axis, which in turn requires a precisely aligned optical setup. To overcome this problem, a computer-generated hologram (CGH) technique is introduced to TIE-based QPI. A CGH generating defocused point spread function is inserted in the Fourier plane of an object. The CGH acts as a lens and grating with various focal lengths and orientations, allowing multiple defocused intensity distributions to be simultaneously detected on an image sensor plane. The results of a numerical simulation and optical experiment demonstrated the feasibility of the proposed method.

7.
Opt Lett ; 45(12): 3184-3187, 2020 Jun 15.
Article in English | MEDLINE | ID: mdl-32538938

ABSTRACT

Optical scanning holography (OSH) is an attractive technique since 3D information can be obtained with a single pixel detector. However, OSH requires an interferometer, scanning architecture, and a frequency shifter to scan a time-varying Fresnel zone plate (FZP), which makes the optical setup complicated. To reduce the complexity, the polarization sensitivity of a spatial light modulator (SLM) is applied. The proposed method implements a time-varying FZP with an in-line optical setup by using only an SLM. Observing results for a USAF pattern and a fluorescent bead reveals the feasibility of the new motionless holographic 3D imaging technique.

8.
Opt Lett ; 45(10): 2796-2799, 2020 May 15.
Article in English | MEDLINE | ID: mdl-32412469

ABSTRACT

A reconstruction method for multilevel complex encoded data-pages is proposed to increase the recording density of computer-generated-hologram-based holographic data storage by using off-axis digital holography. Although the detection process is based on off-axis digital holography, the proposed method keeps the optical setup a simple and common-path configuration owing to the computer-generated holography. Five-level complex encoded data-pages can be experimentally reconstructed.

9.
Appl Opt ; 58(12): 3083-3090, 2019 Apr 20.
Article in English | MEDLINE | ID: mdl-31044781

ABSTRACT

Conventional computer-generated-hologram-based holographic data storage (CGH-HDS) needs to use a multilevel modulatable spatial light modulator (SLM). A binary SLM usually has a higher refresh rate than a multilevel one, and it enables HDS to increase the data transfer rate. To increase the data transfer rate by using a binary SLM, the introduction of a binary CGH is proposed. In general, a binary CGH degrades the image quality of reconstructed intensity distribution and emphasizes high spatial frequency components of datapages. In the proposed method, reconstructed intensity distributions that satisfy image quality as datapages can be obtained with low-pass filtering with an aperture at a plane of a recording medium. The optimum size of an aperture is numerically evaluated. The proposed method is experimentally verified. Moreover, the proposed method can achieve single and multiplexed recording of three datapages by a spherical reference beam with a binary CGH.

10.
Appl Opt ; 57(30): 8836-8840, 2018 Oct 20.
Article in English | MEDLINE | ID: mdl-30461865

ABSTRACT

To increase the recording density of computer-generated-hologram (CGH)-based holographic data storage, a phase data page reconstruction method by the transport of intensity equation (TIE) is proposed. The TIE generally requires a scanning image sensor because the phase retrieval process needs at least two defocused intensity distributions. Although the TIE is applied, the proposed method enables detection of the distributions simultaneously by utilizing an extra conjugate component reconstructed from the CGH. Experimental results show that the proposed method allows reconstructing of a phase data page without any additional elements, which keeps the optical setup simple and low cost.

11.
Appl Opt ; 55(20): 5413-8, 2016 Jul 10.
Article in English | MEDLINE | ID: mdl-27409319

ABSTRACT

A Shack-Hartmann wavefront sensor (SHWFS) that consists of a microlens array and an image sensor has been used to measure the wavefront aberrations of human eyes. However, a conventional SHWFS has finite dynamic range depending on the diameter of the each microlens. The dynamic range cannot be easily expanded without a decrease of the spatial resolution. In this study, an adaptive spot search method to expand the dynamic range of an SHWFS is proposed. In the proposed method, spots are searched with the help of their approximate displacements measured with low spatial resolution and large dynamic range. By the proposed method, a wavefront can be correctly measured even if the spot is beyond the detection area. The adaptive spot search method is realized by using the special microlens array that generates both spots and discriminable patterns. The proposed method enables expanding the dynamic range of an SHWFS with a single shot and short processing time. The performance of the proposed method is compared with that of a conventional SHWFS by optical experiments. Furthermore, the dynamic range of the proposed method is quantitatively evaluated by numerical simulations.

12.
Appl Opt ; 53(19): 4136-40, 2014 Jul 01.
Article in English | MEDLINE | ID: mdl-25089971

ABSTRACT

A design method of an input phase mask for holographic memory is proposed. In the method, a modification of a design procedure and another restraint condition are applied to our conventional design method. The light use efficiency and the quality of a reconstructed image are improved. The performance of an input phase mask designed by the method is confirmed by numerical simulations. Finally, a suitable design condition of an input phase mask is determined from simulation results.

SELECTION OF CITATIONS
SEARCH DETAIL