1.
Heart Rhythm ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38759918

ABSTRACT

BACKGROUND: Novel diamond-embedded catheter enables precise temperature-controlled ablation. However, the effects of contact angle on lesion formation of this catheter are poorly understood. OBJECTIVE: This study evaluated lesion formation using the temperature-controlled ablation catheter embedded with diamond at different angles in a porcine experimental model. METHODS: We used freshly sacrificed porcine hearts, and radiofrequency catheter ablation was performed at 50 watts for 15 s at an upper-temperature setting of 60°C. The contact force (5, 10, and 30 g) and catheter contact angles (30°, 45°, and 90°) were changed in each set (n = 13 each). The surface width, maximum lesion width, lesion depth, surface area, distance from the distal edge to the widest area, and impedance drop were evaluated. RESULTS: The surface width and maximum lesion width were longer at 30° than at 90° (p<0.05). There were no significant differences in the lesion depth by catheter angle except at 30 g. The surface area was larger at 30° than at 90° (p<0.05). The distance from the distal edge to the widest area was longer at 30° than at 90° (p<0.05). There were no significant differences in the impedance drop according to the catheter angle. CONCLUSION: With the diamond-embedded temperature-controlled ablation catheters, the lesion width increased at a shallower contact angle, whereas the lesion depth did not. The surface area also increased at a shallower contact angle. This catheter created a large ablation lesion on the proximal side of the catheter, which looked like a "Honey pot."

2.
Sci Rep ; 14(1): 9874, 2024 04 30.
Article in English | MEDLINE | ID: mdl-38684785

ABSTRACT

To efficiently allocate medical resources at disaster sites, medical workers perform triage to prioritize medical treatments based on the severity of the wounded or sick. In such instances, evaluators often assess the severity status of the wounded or sick quickly, but their measurements are qualitative and rely on experience. Therefore, we developed a wearable device called Medic Hand in this study to extend the functionality of a medical worker's hand so as to measure multiple biometric indicators simultaneously without increasing the number of medical devices to be carried. Medic Hand was developed to quantitatively and efficiently evaluate "perfusion" during triage. Speed is essential during triage at disaster sites, where time and effort are often spared to attach medical devices to patients, so the use of Medic Hand as a biometric measurement device is more efficient for collecting biometric information. For Medic Hand to be handy during disasters, it is essential to understand and improve upon factors that facilitate its public acceptance. To this end, this paper reports on the usability evaluation of Medic Hand through a questionnaire survey of nonmedical workers.


Subject(s)
Biometry , Triage , Wearable Electronic Devices , Humans , Triage/methods , Biometry/methods , Biometry/instrumentation , Male , Female , Adult , Surveys and Questionnaires
3.
Acute Med Surg ; 10(1): e890, 2023.
Article in English | MEDLINE | ID: mdl-37841963

ABSTRACT

Sepsis is the leading cause of death worldwide. Considering regional variations in the characteristics of patients with sepsis, a better understanding of the epidemiology in Japan will lead to further development of strategies for the prevention and treatment of sepsis. To investigate the epidemiology of sepsis, we conducted a systematic literature review of PubMed between 2003 and January 2023. Among the 78 studies using a Japanese administrative database, we included 20 that defined patients with sepsis as those with an infection and organ dysfunction. The mortality rate in patients with sepsis has decreased since 2010, reaching 18% in 2017. However, the proportion of inpatients with sepsis is increasing. A study comparing short-course (≤7 days) and long-course (≥8 days) antibiotic administration showed lower 28-day mortality in the short-course group. Six studies on the treatment of patients with septic shock reported that low-dose corticosteroids or polymyxin B hemoperfusion reduced mortality, whereas intravenous immunoglobulins had no such effect. Four studies investigating the effects of treatment in patients with sepsis-associated disseminated intravascular coagulation demonstrated that antithrombin may reduce mortality, whereas recombinant human soluble thrombomodulin does not. A descriptive study of medical costs for patients with sepsis showed that the effective cost per survivor decreased over an 8-year period from 2010 to 2017. Sepsis has a significant impact on public health, and is attracting attention as an ongoing issue. Further research to determine more appropriate prevention methods and treatment for sepsis should be a matter of priority.

4.
Prehosp Disaster Med ; 38(3): 319-325, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37272378

ABSTRACT

INTRODUCTION: Capillary refill time (CRT) is an indicator of peripheral circulation and is recommended in the 2021 guidelines for treating and managing sepsis. STUDY OBJECTIVE: This study developed a portable device to realize objective CRT measurement. Assuming that peripheral blood flow obstruction by the artery occlusion test (AOT) or venous occlusion test (VOT) increases the CRT, the cut-off value for peripheral circulatory failure was studied by performing a comparative analysis with CRT with no occlusion test (No OT). METHODS: Fourteen (14) healthy adults (age: 20-26 years) participated in the study. For the vascular occlusion test, a sphygmomanometer was placed on the left upper arm of the participant in the supine position, and a pressure of 30mmHg higher than the systolic pressure was applied for AOT, a pressure of 60mmHg was applied for VOT, respectively, and no pressure was applied for No OT. The CRT was measured from the index finger of the participant's left hand. RESULTS: Experimental results revealed that CRT was significantly longer in the AOT and did not differ significantly in the VOT. The cut-off value for peripheral circulatory failure was found to be 2.88 seconds based on Youden's index by using receiver operating characteristic (ROC) analysis with AOT as positive and No OT as negative. CONCLUSION: Significant results were obtained in a previous study on the evaluation of septic shock patients when CRT > three seconds was considered abnormal, and the cut-off value for peripheral circulatory failure in the current study validated this.


Subject(s)
Shock, Septic , Shock , Humans , Young Adult , Adult , Hemodynamics/physiology , Shock/diagnosis , Shock, Septic/diagnosis , Shock, Septic/therapy , Blood Pressure/physiology , ROC Curve
6.
J Interv Card Electrophysiol ; 66(2): 485-492, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36074285

ABSTRACT

BACKGROUND: The lesion size index (LSI) predicts radiofrequency (RF) ablation lesion size and is an established parameter for pulmonary vein isolation. However, the effectiveness and safety of LSI for cavotricuspid isthmus (CTI) linear ablation remain unclear. METHODS: This single-center retrospective study included 50 of patients (67 ± 10 years, 68% male) who underwent de novo CTI linear ablation between July 2020 and December 2020. The LSI target was set at 5.0 and 4.0 for the anterior 2/3 and posterior 1/3 segments, respectively. Acute procedural parameters of ablation were evaluated. RESULTS: Acute bidirectional CTI block was achieved in all patients with an RF application time of 4.0 min (3.1-5.0 min), RF application number of 15 ± 7, and length of CTI of 36.9 ± 9.3 mm. First-pass bidirectional conduction block of the CTI was achieved in 39/50 (78%) patients. No major complications were observed. The contact force (CF) per application was significantly lower in the gap tag group than in the non-gap tag group (7 g [7-8 g] vs. 10 g [7-12 g], P = 0.0284). CONCLUSIONS: LSI-guided CTI linear ablation is an effective and safe treatment approach. CF affects gap formation, even when the target LSI is the same.


Subject(s)
Atrial Flutter , Catheter Ablation , Humans , Male , Female , Atrial Flutter/surgery , Treatment Outcome , Retrospective Studies , Catheter Ablation/adverse effects , Tricuspid Valve/surgery
7.
J Arrhythm ; 38(6): 991-996, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36524028

ABSTRACT

Background: Previous studies have identified noninvasive methods for predicting atrial fibrillation (AF) recurrence after catheter ablation (CA). We assessed the association between AF recurrence and atrial late potentials (ALPs), which were measured using P-wave signal-averaged electrocardiography (P-SAECG). Methods: Consecutive patients with paroxysmal AF who underwent their first CA at our institution between August 2015 and August 2019 were enrolled. P-SAECG was performed before CA. Two ALP parameters were evaluated: the root-mean-square voltage during the terminal 20 ms (RMS20) and the P-wave duration (PWD). Positive ALPs were defined as an RMS20 <2.2 µV and/or a PWD >115 ms. Patients were allocated to either the recurrence or nonrecurrence group based on the presence of AF recurrence at the 1-year follow-up post-CA. Results: Of the 190 patients (age: 65 ± 11 years, 37% women) enrolled in this study, 21 (11%) had AF recurrence. The positive ALP rate was significantly higher in the recurrence group than in the nonrecurrence group (86% vs. 64%, p = .04), despite the absence of differences in other baseline characteristics between the two groups. In the multivariate analysis, positive ALP was an independent predictor of AF recurrence (odds ratio: 3.83, 95% confidence interval: 1.05-14.1, p = .04). Conclusions: Positive ALP on pre-CA P-SAECG is associated with AF recurrence after CA.

10.
Sensors (Basel) ; 22(6)2022 Mar 09.
Article in English | MEDLINE | ID: mdl-35336279

ABSTRACT

In recent years, environmental information monitoring in the agricultural field has become an important issue. There is an increasing demand for meteorological information in local areas such as a rice field, a greenhouse, etc., owned by an agricultural worker. Conventional research has been actively conducted on weather stations in local areas. However, weather stations that are inexpensive, highly accurate, and have achieved stable measurements indoors and outdoors for long periods of time (over a year) are not reported. In addition, there is a lack of research that simultaneously acquires weather information, stores weather information, and provides weather information to farmers. These three functions are important in the agricultural field. In this paper, we discuss the development of a meteorological observation device, the construction of a cloud server for storing meteorological information, and the provision of information to users. First, we develop the novel meteorological observation device (KOSEN-Weather Station), which applies a simple Aßmann's aspiration psychrometer for highly accurate temperature and humidity measurements. To evaluate the reliability of KOSEN-WS, we compare the weather information measured by KOSEN-WS with that of WXT520. As a result, it is shown that KOSEN-WS is viable. Then, KOSEN-WS is installed in the field, and the stability and durability of KOSEN-WS are examined. As a result, the KOSEN-WS has been operating stably over 19 months and provides weather information to users. Then, it is shown that the KOSEN-WS is able to operate continuously under the environment of -16.5 °C to 44.9 °C. Next, for the storage of meteorological information, we construct the cloud server. Then, a webpage is created to provide easy-to-understand weather information to farmers. Furthermore, to prevent damage to crops, if the current temperature is lower than the set temperature, or if the current temperature is higher than the set temperature, an alert is sent to the farmers. As a result, the system is highly evaluated by agricultural workers and JA staff. From the above results, the effectiveness of this system is shown.


Subject(s)
Farmers , Weather , Humans , Humidity , Meteorology , Reproducibility of Results
11.
J Arrhythm ; 38(1): 160-162, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35222764

ABSTRACT

We performed cavotricuspid isthmus (CTI) linear ablation for atrial flutter; however, the tachycardia cycle length was not changed at all. In such cases, repeated or broad line ablation is usually performed. We presented that high-density three-dimensional mapping after the first CTI linear ablation, which revealed the complex tachycardia circuit with the epicardial and endocardial breakthrough.

12.
J Cardiovasc Electrophysiol ; 33(3): 380-388, 2022 03.
Article in English | MEDLINE | ID: mdl-35018687

ABSTRACT

BACKGROUND: Local impedance (LI) can indirectly measure catheter contact and tissue temperature during radiofrequency catheter ablation (RFCA). However, data on the effects of catheter contact angle on LI parameters are scarce. This study aimed to evaluate the influence of catheter contact angle on LI changes and lesion size with two different LI-sensing catheters in a porcine experimental study. METHODS: Lesions were created by the INTELLANAV MiFi™ OI (MiFi) and the INTELLANAV STABLEPOINT™ (STABLEPOINT). RFCA was performed with 30 W and a duration of 30 s. The contact force (CF) (0, 5, 10, 20, and 30 g) and catheter contact angle (30°, 45°, and 90°) were changed in each set (n = 8 each). The LI rise, LI drop, and lesion size were evaluated. RESULTS: The LI rise increased as CF increased. There was no angular dependence with the LI rise under all CFs in the MiFi. On the other hand, the LI rise at 90° was lower than at 30° under 5 and 10 g of CF in STABLEPOINT. The LI drop increased as CF increased. Regarding the difference in catheter contact angles, the LI drop at 90° was lower than that at 30° for both catheters. The maximum lesion widths and surface widths were smaller at 90° than at 30°, whereas there were no differences in lesion depths. CONCLUSION: The LI drop and lesion widths at 90° were significantly smaller than those at 30°, although the lesion depths were not different among the 3 angles for the MiFi and STABLEPOINT.


Subject(s)
Catheter Ablation , Animals , Catheter Ablation/adverse effects , Catheters , Electric Impedance , Equipment Design , Swine
14.
Heart Vessels ; 37(4): 628-637, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34613425

ABSTRACT

The recurrence of atrial fibrillation (AF) after catheter ablation (CA) is still an unsolved issue. Although structural remodeling is relatively well defined, the method to assess electrical remodeling of the atrium is not well established. In this study, we evaluated the relationship between atrial conduction properties and recurrence after CA for AF. One hundred six consecutive patients (66 ± 11 years old, male: 68%) who underwent CA for AF with a CARTO system from July 2016 to July 2019 were enrolled in this study. An activation map of both atria was constructed to precisely evaluate the total conduction time, distance, and conduction velocity between the earliest and latest activation sites during sinus rhythm. All parameters were compared between the patients with or without AF recurrence. Of the patients, 27 had an AF recurrence (Rec group). The left atrial (LA) conduction velocity was significantly slower in the Rec group than in the non-Rec group (101.2 ± 17.9 vs. 116.9 ± 18.0 cm/s, P < 0.01). Likewise, the right atrial (RA) conduction velocity was significantly slower in the Rec group than in the non-Rec group (81.1 ± 17.5 vs. 103.6 ± 25.4 cm/s, P < 0.01). A multivariate logistic analysis demonstrated that the LA and RA conduction velocities were independent predictors of AF recurrence, with adjusted odds ratios of 0.95 (95% confidential interval: 0.91-0.98, P < 0.01) and 0.94 (0.89-0.98, P < 0.01), respectively. In conclusion, slower conduction velocity of the atrium was associated with AF recurrence after pulmonary vein isolation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Atria , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
15.
Circ Rep ; 3(9): 497-503, 2021 Sep 10.
Article in English | MEDLINE | ID: mdl-34568628

ABSTRACT

Background: The incidence of new-onset atrial high-rate episode (AHRE) is higher among patients with cardiac implantable electronic devices (CIEDs) than in the general population. We sought to elucidate the clinical factors associated with AHRE in CIED patients, including P-wave dispersion (PWD) in sinus rhythm. Methods and Results: In all, 101 patients with CIEDs newly implanted between 2010 and 2014 were included in the study. PWD was measured at the time of device implantation via a body-surface electrocardiogram. AHRE was defined as any episode of sustained atrial tachyarrhythmia (>170 beats/min) recorded in the device's memory. Patients were divided into an AHRE (n=34) and non-AHRE (n=67) group based on the presence or absence of AHRE within 1 year of device implantation and compared. Mean (±SD) patient age was 75±11 years. A greater incidence of sick sinus syndrome (P=0.05) and longer PWD (62.6±13.1 vs. 38.2±13.9 ms; P<0.0001) were apparent in the AHRE than non-AHRE group. Multivariate analysis revealed that PWD was an independent predictor of new-onset AHRE (odds ratio 1.11; 95% confidence interval 1.06-1.17; P<0.0001). In logistic regression analysis, receiver-operating characteristic curve analysis (area under the curve 0.90; P<0.001) suggested the best cut-off value for PWD was 48 mm (sensitivity 73.8%, specificity 77.9%). Conclusions: PWD is a simple but feasible predictor of new-onset AHRE in patients with CIEDs.

17.
J Arrhythm ; 37(3): 558-565, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34141008

ABSTRACT

BACKGROUND: Although the lesion size index (LSI) has been well established, it is sometimes difficult to achieve first-pass pulmonary vein isolation (PVI) and to avoid acute pulmonary vein reconnections, even with LSI-guided procedures. The purpose of this study was to assess the predictive accuracy of a novel parameter, the optimized lesion size index (o-LSI), to perform PVI. METHODS: The voltage maps created by the Advisor™ high-density (HD) grid catheter before PVI in 35 atrial fibrillation (AF) patients were examined for an association between the voltage amplitude and insufficient ablation sites (IAS), which were defined as either (i) spontaneous reconnection sites, (ii) dormant PV conduction sites unmasked with 20 mg of adenosine triphosphate disodium hydrate (ATP) injection, or (iii) PV-LA gap sites after the initial PVI. RESULTS: IAS was observed in 25/1417 of the total ablation sites. IAS was significantly associated with higher bipolar voltage areas (4.20 ± 2.68 vs 2.43 ± 1.93 mV, P < .0001) but not with LSI. A novel index, o-LSI (defined as LSI/bipolar voltage), was significantly lower in IAS than in others (1.14 [0.82, 1.81] vs 2.35 [1.31, 4.80] LSI/mV). By receiver operating characteristic analysis, an o-LSI of 2.04 was the best cutoff value for the prediction of IAS (88% sensitivity and 55% specificity, P < .0001, areas under the curve: 0.742). CONCLUSION: Low o-LSI was strongly associated with IAS, potentially providing a novel index to improve first-pass PV isolation.

18.
Ann Vasc Surg ; 75: 534.e11-534.e14, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33945862

ABSTRACT

Proximal aortic clamping under normothermia is generally adequate for operative repair of abdominal aortic rupture; however, the hypothermic circulatory arrest (HCA) technique is not as common. Proximal exposure and clamping are sometimes difficult due to the risk of bleeding, rerupture, and ischemia. We present a successful case of a ruptured abdominal aortic aneurysm (AAA) that was repaired using cardiopulmonary bypass with HCA. A 75-year-old man presented with sudden back pain and was diagnosed with a ruptured AAA using computed tomography. The aneurysm had a maximal diameter of 100 mm and protruded anteriorly just below the renal arteries. The rupture site was close to the renal arteries, and thus, there was a high risk of bleeding and shock during proximal exposure. Cardiopulmonary bypass was established by cannulation of the right axillary artery and right femoral vein, following which open laparotomy was performed. Proximal exposure and anastomosis could be safely performed using HCA. This cardiopulmonary bypass with HCA technique may be useful as a surgical strategy for ruptured juxta-renal AAAs.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortic Rupture/surgery , Blood Vessel Prosthesis Implantation , Circulatory Arrest, Deep Hypothermia Induced , Aged , Anastomosis, Surgical , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Rupture/diagnostic imaging , Cardiopulmonary Bypass , Humans , Ligation , Male , Treatment Outcome
19.
Kyobu Geka ; 74(3): 221-223, 2021 Mar.
Article in Japanese | MEDLINE | ID: mdl-33831878

ABSTRACT

The patient was a 67-year-old man. At 22 years of age, he underwent aortic valve replacement with Starr-Edwards ball valve. At 67 years of age, he complained of fatigue of the New York Heart Association (NYHA) class Ⅲ condition. He was diagnosed with mitral regurgitation, tricuspid regurgitation, ascending aortic aneurysm and chronic atrial fibrillation. Transthoracic and transesophageal echocardiograms showed a mobile, elongated echogenic mass attached to the valve cage and floating downstream. We performed Bentall procedure, ascending aortic replacement, mitral valve replacement, tricuspid annuloplasty and left atrial appendage closure. Explanted ball valve showed extensive cloth destruction and partial cloth tear. Mild pannus formation was observed beneath the valve. Despite 45 years after initial operation, significant valve dysfunction was not observed.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Prosthesis Failure , Reoperation
20.
Gen Thorac Cardiovasc Surg ; 69(8): 1267-1270, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33770347

ABSTRACT

A 79-year-old man with atrial fibrillation and heart failure due to grade 4 + mitral valve regurgitation after coronary artery bypass underwent the MitraClip procedure using two clips. Three days after the procedure, chest radiographs indicated migration of one of the two clips into the left ventricle. He suffered from 3 + recurrent mitral regurgitation, tricuspid valve regurgitation. The echocardiogram and computed tomography scans indicated migration of the clip into the left ventricular apex; he underwent mitral valve replacement, removal of the migrated clip to prevent embolism, left atrial appendage closure, and tricuspid valve ring-annuloplasty. In the postoperative acute phase, embolism by detached and lost MitraClip device is possible, which can be difficult to remove.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Aged , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Treatment Outcome