Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
JACC Clin Electrophysiol ; 5(10): 1158-1167, 2019 10.
Article in English | MEDLINE | ID: mdl-31648740

ABSTRACT

OBJECTIVES: This study sought to evaluate the association between contrast-enhanced multidetector computed tomography (CE-MDCT) attenuation and local epicardial conduction speed (ECS) and electrographic abnormalities in patients with arrhythmogenic right ventricular cardiomyopathy (ARVC) and ventricular tachycardia (VT). BACKGROUND: CE-MDCT is a widely available and fast imaging technology with high spatial resolution that is less prone to defibrillator generator-related safety issues and image artifacts. However, the association between hypoattenuation on MDCT and VT substrates in ARVC remains unknown. METHODS: Patients with ARVC who underwent CE-MDCT followed by endocardial (n = 30) and epicardial (n = 21) electroanatomical mapping (EAM) and VT ablation were prospectively enrolled. Right ventricular (RV) mid-myocardial attenuation was calculated from 3-dimensional MDCT images and registered to EAM. Local ECS was calculated by averaging the ECS between each point and 5 adjacent points with concordant wave front direction. RESULTS: A total of 17,311 epicardial and 5,204 endocardial points were included. In multivariable regression analysis clustered by patient, RV myocardial attenuation was associated with epicardial bipolar voltage amplitude (2.5% decrease in amplitude per 10 HU decrease in attenuation; p < 0.001), with endocardial unipolar voltage amplitude (0.9% decrease in amplitude per 10 HU decrease in attenuation; p < 0.001), and with ECS (0.4% decrease in ECS per 10 HU decrease in attenuation; p = 0.001). CONCLUSIONS: CE-MDCT attenuation distribution is associated with regional ECS and electrographic amplitude in ARVC. Regions with low attenuation likely reflect fibro-fatty involvement in the RV and may serve as important VT substrates in patients with ARVC who are undergoing VT ablation.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia/diagnostic imaging , Epicardial Mapping , Multidetector Computed Tomography , Pericardium/diagnostic imaging , Tachycardia, Ventricular/diagnostic imaging , Adult , Arrhythmogenic Right Ventricular Dysplasia/physiopathology , Electrocardiography , Electrophysiologic Techniques, Cardiac , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Pericardium/physiopathology , Tachycardia, Ventricular/physiopathology , Young Adult
2.
Heart Rhythm ; 16(4): 588-594, 2019 04.
Article in English | MEDLINE | ID: mdl-30935494

ABSTRACT

BACKGROUND: Cardiac magnetic resonance imaging has been shown to be beneficial for identification of the ventricular tachycardia (VT) substrate before catheter ablation. Contrast-enhanced perfusion multidetector computed tomography (CEP-MDCT) is more generalizable to clinical practice, and wall thickness and regional hypoenhancement on CEP-MDCT can identify potential substrate sites, albeit with decreased specificity. OBJECTIVE: The purpose of this study was to evaluate the association between wall thickness and attenuation on CEP-MDCT with local conduction velocity (CV) and electrogram abnormalities in patients with postinfarct VT. METHODS: Fourteen patients with postinfarct VT underwent preprocedural CEP-MDCT followed by endocardial electroanatomic mapping (EAM) and ablation. Myocardial attenuation and wall thickness were calculated from 3-dimensional MDCT images using ADAS-VT software (Galgo Medical). EAM was registered with 3-dimensional MDCT images using the CartoMERGE module of CARTO3 software (Biosense Webster). Local CV was calculated by averaging the velocity between each point and 5 adjacent points with concordant wavefront direction. RESULTS: A total of 3689 points were included. In multivariable regression analysis clustered by patient, local CV was positively associated with myocardial attenuation, bipolar voltage, unipolar voltage, and wall thickness. Each 10-HU drop in full-thickness attenuation correlated to 2.6% decrease in CV (P <.001) and 5.5% decrease in bipolar voltage amplitude (P <.001), after adjusting for wall thickness. CONCLUSION: Myocardial attenuation distribution on CEP-MDCT is associated with regional CV and electrogram amplitude. Regions with low CV identified with low attenuation on CEP-MDCT may serve as important VT substrates in postinfarct patients.


Subject(s)
Heart Conduction System/physiopathology , Multidetector Computed Tomography/methods , Myocardial Infarction/complications , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/etiology , Contrast Media , Electrocardiography , Epicardial Mapping , Humans , Imaging, Three-Dimensional , Iopamidol , Middle Aged , Prospective Studies , Radiographic Image Interpretation, Computer-Assisted , Tachycardia, Ventricular/physiopathology , Triiodobenzoic Acids
3.
Heart Rhythm ; 15(11): 1617-1625, 2018 11.
Article in English | MEDLINE | ID: mdl-29870783

ABSTRACT

BACKGROUND: Contrast-enhanced cardiac computed tomography (CE-CT) provides useful substrate characterization in patients with ventricular tachycardia (VT). OBJECTIVE: The purpose of this study was to describe the association between endocardial electrogram measurements and myocardial characteristics on CE-CT, in particular the field of view of electrogram features. METHODS: Fifteen patients with postinfarct VT who underwent catheter ablation with preprocedural CE-CT were included. Electroanatomic maps were registered to CE-CT, and myocardial attenuation surrounding each endocardial point was measured at a radius of 5, 10, and 15 mm. The association between endocardial voltage and attenuation was assessed using a multilevel random effects linear regression model, clustered by patient, with best model fit defined by highest log likelihood. RESULTS: A total of 4698 points were included. There was a significant association of bipolar and unipolar voltage with myocardial attenuation at all radii. For unipolar voltage, the best model fit was at an analysis radius of 15 mm regardless of the mapping catheter used. For bipolar voltage, the best model fit was at an analysis radius of 15 mm for points acquired with a conventional ablation catheter. In contrast, the best model fit for points acquired with a multipolar mapping catheter was at an analysis radius of 5 mm. CONCLUSION: Myocardial attenuation on CE-CT indicates a smaller myocardial field of view of bipolar electrograms using multipolar catheters with smaller electrodes in comparison to standard ablation catheters despite similar interelectrode spacing. Smaller electrodes may provide improved spatial resolution for the definition of myocardial substrate for VT ablation.


Subject(s)
Body Surface Potential Mapping/methods , Cardiac Catheters , Electrophysiologic Techniques, Cardiac/methods , Imaging, Three-Dimensional , Multidetector Computed Tomography/methods , Tachycardia, Ventricular/diagnosis , Triiodobenzoic Acids/pharmacology , Aged , Catheter Ablation , Contrast Media/pharmacology , Equipment Design , Female , Follow-Up Studies , Humans , Male , Middle Aged , Pericardium , Reproducibility of Results , Retrospective Studies , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...