Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Orthopedics ; 43(3): e177-e181, 2020 May 01.
Article in English | MEDLINE | ID: mdl-32191950

ABSTRACT

Historically, extra-articular scapular body fractures were treated nonsurgically, but displaced fractures of the glenoid neck can lead to dysfunction. Controversy exists regarding which extra-articular scapular fractures should be treated surgically; however, nonsurgical management of severely displaced scapular body fractures can result in satisfactory outcomes. Inclusion criteria for this study were medial or lateral displacement greater than 2 cm, angular deformity between fracture fragments greater than 45°, or glenopolar angle less than 22°. Functional outcomes included Disabilities of the Arm, Shoulder and Hand (DASH) score, Short Form-36 (SF-36) score, and American Shoulder and Elbow Surgeons (ASES) shoulder score. Radiographs and computed tomography scans were available for all patients. Range of motion (ROM), strength, other injuries, and complications also were recorded. Twelve patients (10 males, 2 females) with a mean age of 45.6 years (range, 29-57 years) underwent follow-up for a mean of 54.1 months (range, 28.2-74.4 months). At latest follow-up, mean DASH score was 8.9 (range, 0-35), mean SF-36 score was 72.2 (range, 57.3-96.1), and mean ASES score was 85.9 (range, 46.7-100). Mean ROM and strength expressed as a percentage of the contralateral side ranged from 88% to 99% and 70% to 93%, respectively. At longest follow-up, 10 patients reported excellent satisfaction with their treatment. There were no radiographic non-unions. One patient with concomitant clavicle and acromion fractures treated surgically had a postoperative infection requiring operative irrigation and debridement. None of the patients required or sought additional treatment. Nonoperative treatment of highly displaced scapular body fractures resulted in good patient satisfaction, satisfactory long-term functional outcomes, and only minor loss of motion and strength. [Orthopedics. 2020;43(3):e177-e181.].


Subject(s)
Clavicle/injuries , Fracture Healing/physiology , Fractures, Bone/therapy , Orthopedic Procedures , Recovery of Function/physiology , Scapula/injuries , Shoulder Injuries , Spinal Fractures/therapy , Adult , Clavicle/diagnostic imaging , Female , Fractures, Bone/diagnostic imaging , Humans , Male , Middle Aged , Patient Satisfaction , Range of Motion, Articular/physiology , Scapula/diagnostic imaging , Shoulder Joint/diagnostic imaging , Spinal Fractures/diagnostic imaging , Tomography, X-Ray Computed , Treatment Outcome
2.
J Orthop ; 18: 76-79, 2020.
Article in English | MEDLINE | ID: mdl-32189888

ABSTRACT

PURPOSE: The treatment of distal femur fractures with extensive metaphyseal comminution is frequently complicated by high rates of nonunion and varus collapse. Dual plating with lateral and medial locking plates for these types of fractures has shown promising results in the recent literature. We hypothesize that dual plating of comminuted distal femur fractures leads to higher union rates and lower revision rates compared to an isolated lateral locking plate. METHODS: A retrospective medical chart review between January 2015 and December 2017 was conducted. Inclusion criteria included patients 18 years of age and older who sustained a complex distal femur fracture (AO/OTA 33-C2/33-C3 or periprosthetic fracture with significant metaphyseal comminution) and at least 6 months of follow up. Patients with simple fracture patterns, alternative fixation methods, and inadequate follow up were excluded. All patients in the single plating group were treated with a lateral distal femoral locking plate using a lateral approach. In the patients treated with dual plating, an extensile parapatellar approach was utilized for fracture reduction and placement of an adjunctive medial plate. Demographic information, fracture types, injury severity score (ISS), medical comorbidities, type of surgical fixation, union rates, complications, knee range of motion, time to follow up, and need for revision surgery were extrapolated from the medical charts for analysis. RESULTS: Twenty-one patients were included in the study. Thirteen patients underwent single plate fixation and 8 underwent dual plate fixation. There were no significant differences in demographics, number of co-morbidities, fracture classification, or ISS between single and dual plate groups (p > 0.05 for all). There was a statistically significant difference in union rates between the single plate group (6 nonunions, 4 unions, and 3 delayed unions) and the dual plate group, with no nonunions or delayed unions (p = 0.0049). Although not statistically significant, 4 patients treated with single plating underwent revision ORIF, compared to none in the dual plating group (p = 0.13). There were no significant differences in time to follow up, time to full weight bearing, or infection rates (p > 0.1 for all). CONCLUSION: Based on these results, the medial and lateral locked plating technique demonstrates a higher union rate, with possible lower rates of revision surgery, compared to a single lateral plate in highly comminuted distal femur fractures. LEVEL OF EVIDENCE: Level 3. Retrospective Cohort Study.

3.
J Am Acad Orthop Surg Glob Res Rev ; 2(7): e028, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30280141

ABSTRACT

INTRODUCTION: We developed an economical three-dimensional printed and casted simulator of the hand for the training of percutaneous pinning. This simulator augments the traditional "See one, do one, teach one" training model. METHODS: To evaluate the simulator, five expert orthopaedic surgeons were recruited to perform percutaneous pinning on the simulator and then to complete a questionnaire on its realism and expected usefulness. Evaluation was based on responses to multiple-choice questions and a Likert-type scale. RESULTS: All subjects expressed that the tactile hand simulator is useful for residency training. They would recommend the simulator to their colleagues and indicated interest in testing future iterations. Subjects rated highly the realism of the material, the purchase of the pin, and the cortical-cancellous bone interface. CONCLUSION: The learning of tactile skills in addition to visual cues on a tactile simulator is expected to benefit residents. It provides a low-cost and low-risk environment outside the operating room for residents to hone their skills.

SELECTION OF CITATIONS
SEARCH DETAIL