Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Circ Res ; 134(1): 46-59, 2024 01 05.
Article in English | MEDLINE | ID: mdl-38095085

ABSTRACT

BACKGROUND: Brugada syndrome is associated with loss-of-function SCN5A variants, yet these account for only ≈20% of cases. A recent genome-wide association study identified a novel locus within MAPRE2, which encodes EB2 (microtubule end-binding protein 2), implicating microtubule involvement in Brugada syndrome. METHODS: A mapre2 knockout zebrafish model was generated using CRISPR/Cas9 (clustered regularly interspaced short palindromic repeats/clustered regularly interspaced short palindromic repeat-associated protein 9) and validated by Western blot. Larval hearts at 5 days post-fertilization were isolated for voltage mapping and immunocytochemistry. Adult fish hearts were used for ECG, patch clamping, and immunocytochemistry. Morpholinos were injected into embryos at 1-cell stage for knockdown experiments. A transgenic zebrafish line with cdh2 tandem fluorescent timer was used to study adherens junctions. Microtubule plus-end tracking and patch clamping were performed in human induced pluripotent stem cell derived cardiomyocytes (iPSC-CMs) with MAPRE2 knockdown and knockout, respectively. RESULTS: Voltage mapping of mapre2 knockout hearts showed a decrease in ventricular maximum upstroke velocity of the action potential and conduction velocity, suggesting loss of cardiac voltage-gated sodium channel function. ECG showed QRS prolongation in adult knockout fish, and patch clamping showed decreased sodium current density in knockout ventricular myocytes and arrhythmias in knockout iPSC-CMs. Confocal imaging showed disorganized adherens junctions and mislocalization of mature Ncad (N-cadherin) with mapre2 loss of function, associated with a decrease of detyrosinated tubulin. MAPRE2 knockdown in iPSC-CMs led to an increase in microtubule growth velocity and distance, indicating changes in microtubule dynamics. Finally, knockdown of ttl encoding tubulin tyrosine ligase in mapre2 knockout larvae rescued tubulin detyrosination and ventricular maximum upstroke velocity of the action potential. CONCLUSIONS: Genetic ablation of mapre2 led to a decrease in voltage-gated sodium channel function, a hallmark of Brugada syndrome, associated with disruption of adherens junctions, decrease of detyrosinated tubulin as a marker of microtubule stability, and changes in microtubule dynamics. Restoration of the detyrosinated tubulin fraction with ttl knockdown led to rescue of voltage-gated sodium channel-related functional parameters in mapre2 knockout hearts. Taken together, our study implicates microtubule dynamics in the modulation of ventricular conduction.


Subject(s)
Brugada Syndrome , Induced Pluripotent Stem Cells , Voltage-Gated Sodium Channels , Animals , Humans , Action Potentials , Brugada Syndrome/genetics , Brugada Syndrome/metabolism , Genome-Wide Association Study , Induced Pluripotent Stem Cells/metabolism , Microtubule-Associated Proteins/genetics , Microtubules/metabolism , Myocytes, Cardiac/metabolism , NAV1.5 Voltage-Gated Sodium Channel/genetics , NAV1.5 Voltage-Gated Sodium Channel/metabolism , Tubulin/genetics , Tubulin/metabolism , Voltage-Gated Sodium Channels/metabolism , Zebrafish/genetics , Zebrafish/metabolism
2.
Heart Rhythm ; 20(12): 1720-1726, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37657721

ABSTRACT

BACKGROUND: The diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC) is challenging because of nonspecific clinical findings and lack of conclusive answers from genetic testing (ie, an ARVC-related variant is neither necessary nor sufficient for diagnosis). Despite the revised 2010 Task Force Criteria, patients are still misdiagnosed with ARVC. OBJECTIVE: In patients referred for ARVC, we sought to identify the clinical characteristics and diagnostic confounders for those patients in whom ARVC was ultimately ruled out. METHODS: Patients who were referred to our center with previously diagnosed or suspected ARVC (between January 2011 and September 2019; N = 726) were included in this analysis. RESULTS: Among 726 patients, ARVC was ruled out in 365 (50.3%). The most common presenting symptoms in ruled-out patients were palpitations (n = 139, 38.1%), ventricular arrhythmias (n = 62, 17.0%), and chest pain (n = 53, 14.5%). On the basis of outside evaluation, 23.8% of these patients had received implantable cardioverter-defibrillators (ICDs) and device extraction was recommended in 9.0% after reevaluation. An additional 5.5% had received ICD recommendations, all of which were reversed on reevaluation. The most frequent final diagnoses were idiopathic premature ventricular contractions/ventricular tachycardia/ventricular fibrillation (46.6%), absence of disease (19.2%), and noncardiac presyncope/syncope (17.5%). The most common contributor to diagnostic error was cardiac magnetic resonance imaging, including mistaken right ventricular wall motion abnormalities (33.2%) and nonspecific fat (12.1%). CONCLUSION: False suspicion or misdiagnosis was found in the majority of patients referred for ARVC, resulting in inappropriate ICD implantation or recommendation in 14.5% of these patients. Misdiagnosis or false suspicion was most commonly due to misinterpretation of cardiac magnetic resonance imaging.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Arrhythmogenic Right Ventricular Dysplasia/diagnosis , Arrhythmogenic Right Ventricular Dysplasia/therapy , Arrhythmogenic Right Ventricular Dysplasia/genetics , Arrhythmias, Cardiac , Magnetic Resonance Imaging
3.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37649337

ABSTRACT

AIMS: Pulsed field ablation (PFA) is a non-thermal ablative approach in which cardiomyocyte death is obtained through irreversible electroporation (IRE). Data correlating the biophysical characteristics of IRE and lesion characteristics are limited. The aim of this study was to assess the effect of different procedural parameters [voltage, number of cycles (NoCs), and contact] on lesion characteristics in a vegetal and animal model for IRE. METHODS AND RESULTS: Two hundred and four Russet potatoes were used. Pulsed field ablation lesions were delivered on 3 cm cored potato specimens using a multi-electrode circular catheter with its dedicated IRE generator. Different voltage (from 300 to 1200 V) and NoC (from 1 to 5×) protocols were used. The impact of 0.5 and 1 mm catheter-to-specimen distances was tested. A swine animal model was then used to validate the results observed in the vegetable model. The association between voltage, the NoCs, distance, and lesion depth was assessed through linear regression. An almost perfect linear association between lesion depth and voltage was observed (R2 = 0.95; P < 0.001). A similarly linear relationship was observed between the NoCs and the lesion depth (R2 = 0.73; P < 0.001). Compared with controls at full contact, a significant dampening on lesion depth was observed at 0.5 mm distance (1000 V 2×: 2.11 ± 0.12 vs. 0.36 ± 0.04, P < 0.001; 2.63 ± 0.10 vs. 0.43 ± 0.08, P < 0.001). No lesions were observed at 1.0 mm distance. CONCLUSION: In a vegetal and animal model for IRE assessment, PFA lesion characteristics were found to be strongly dependent on voltage settings and the NoCs, with a quasi-linear relationship. The lack of catheter contact was associated with a dampening in lesion depth.


Subject(s)
Adiposity , Obesity , Animals , Swine , Catheters , Electrodes , Electroporation
4.
Circ Arrhythm Electrophysiol ; 16(6): e011603, 2023 06.
Article in English | MEDLINE | ID: mdl-37264920

ABSTRACT

BACKGROUND: Rotational cutting tools are increasingly used in transvenous lead extraction. There are limited data on their safety and efficacy, particularly when used adjunctively for stalled progression. The aim of this study was to evaluate the utilization, safety, and effectiveness of mechanical rotational cutting tools for transvenous lead extraction. METHODS: Patients undergoing transvenous lead extraction at a single tertiary center (April 2015 to January 2021, n=586) were included in this retrospective analysis. The study characterized the 251 patients (42.8%) whose cases involved the TightRail mechanical cutting tool. RESULTS: Among 251 patients, 526 leads were extracted and TightRail was used for 70.5%. The TightRail was used adjunctively with the laser for 65.2% of leads, 97.8% of the time as the second tool after stalled progression. Using a multivariable logistic regression model, we found that active-fixation leads (odds ratio, 2.78 [95% CI, 1.62-4.78]; P=0.0002), dual-coil leads (odds ratio, 3.39 [95% CI, 1.87-6.16]; P<0.0001), and lead dwell time (odds ratio, 1.16 [95% CI for 1-year increase, 1.11-1.21]; P<0.0001) were factors independently associated with adjunctive TightRail use. Stalled progression requiring TightRail occurred most often in the innominate vein and superior vena cava (59.3%). The clinical success rate was 96.8%, and the rate of major adverse events was 2.8%. Only 1 major adverse event was observed during TightRail use. CONCLUSIONS: Rotational cutting with TightRail was used in 42.8% of transvenous lead extractions, predominantly in an adjunctive manner after stalled laser progression in the innominate vein and superior vena cava, and more frequently for dual-coil and leads with longer dwell times. Adjunctive TightRail use carries a low risk of major complications.


Subject(s)
Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Retrospective Studies , Vena Cava, Superior , Device Removal/adverse effects
5.
J Cardiovasc Electrophysiol ; 34(4): 860-868, 2023 04.
Article in English | MEDLINE | ID: mdl-36738148

ABSTRACT

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) is a common therapeutic strategy for patients with either paroxysmal AF (PAF) or persistent AF (persAF), but long-term ablation success rates are imperfect. Maintenance of sinus rhythm immediately before ablation with antiarrhythmic drug (AAD) therapy has been associated with improved outcomes in patients undergoing ablation. Amiodarone has superior efficacy relative to other AADs. Whether failure of amiodarone to maintain sinus rhythm before ablation for either PAF or persAF is associated with poor outcomes is unknown. METHODS: A total of 307 patients who received amiodarone in a 1-year window before undergoing catheter ablation for AF were included. Patients were divided into amiodarone success (n = 183) and amiodarone failure (n = 124) groups based on the response to pre-ablation amiodarone treatment. Analysis of procedural outcomes as a function of response to amiodarone therapy was performed. Patients were followed for at least 12 months postablation, to assess outcomes (adverse events and arrhythmia recurrence). Procedural success was defined by the absence of documented arrhythmia (>30 s) without any antiarrhythmic agents beyond a 90-day blanking period. RESULTS: Following ablation for either PAF or persAF, freedom from any recurrent atrial arrhythmia at 1 year was 57.7% for the entire cohort. One-year freedom from recurrent arrhythmia in the amiodarone success group was comparable to that in the amiodarone failure group (55.7% vs. 60.5%; p = .54). Success rates following ablation did not vary by the response to amiodarone when analyzed for PAF or persAF subgroups. CONCLUSION: Failure to restore and maintain sinus rhythm with amiodarone before ablation for either PAF or persAF is not a predictor of ablation procedural failure. Amiodarone failure alone should not deter practitioners from considering ablation therapy for patients with AF.


Subject(s)
Ablation Techniques , Amiodarone , Atrial Fibrillation , Catheter Ablation , Humans , Amiodarone/therapeutic use , Atrial Fibrillation/surgery , Anti-Arrhythmia Agents/therapeutic use , Catheter Ablation/adverse effects
6.
Nat Commun ; 14(1): 117, 2023 01 10.
Article in English | MEDLINE | ID: mdl-36627270

ABSTRACT

Absence seizures are brief episodes of impaired consciousness, behavioral arrest, and unresponsiveness, with yet-unknown neuronal mechanisms. Here we report that an awake female rat model recapitulates the behavioral, electroencephalographic, and cortical functional magnetic resonance imaging characteristics of human absence seizures. Neuronally, seizures feature overall decreased but rhythmic firing of neurons in cortex and thalamus. Individual cortical and thalamic neurons express one of four distinct patterns of seizure-associated activity, one of which causes a transient initial peak in overall firing at seizure onset, and another which drives sustained decreases in overall firing. 40-60 s before seizure onset there begins a decline in low frequency electroencephalographic activity, neuronal firing, and behavior, but an increase in higher frequency electroencephalography and rhythmicity of neuronal firing. Our findings demonstrate that prolonged brain state changes precede consciousness-impairing seizures, and that during seizures distinct functional groups of cortical and thalamic neurons produce an overall transient firing increase followed by a sustained firing decrease, and increased rhythmicity.


Subject(s)
Consciousness , Epilepsy, Absence , Female , Rats , Humans , Animals , Consciousness/physiology , Rodentia , Seizures , Thalamus , Electroencephalography/methods , Neurons/physiology , Cerebral Cortex
8.
Heart Rhythm O2 ; 3(1): 65-69, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35243437

ABSTRACT

BACKGROUND: Procedural and clinical outcomes of patients undergoing extraction or removal of azygous coils are not well characterized. OBJECTIVE: Evaluate outcomes in patients who undergo device extraction with an azygous coil in situ. METHODS: Patients undergoing extraction with an azygous coil in situ between May 2015 and January 2021 were included in this retrospective single-center analysis. Outcomes included procedural success, use of laser and mechanical cutting tools during the procedure, procedural complications, and mortality. RESULTS: We identified 2 patients undergoing device extraction with an azygous coil in situ with a dwell time greater than 12 months. The patients were male, aged 73 and 83 years. Both had a history of hypertension, atrial fibrillation, heart failure (ejection fractions <15% and 20%), and cardiomyopathy (nonischemic and ischemic), and presented with an infection (case 1 with a single-chamber ICD and Staphylococcus aureus bacteremia, case 2 with a cardiac resynchronization therapy defibrillator pocket infection). The mean dwell time of all 6 leads extracted was 6.43 years (range 1.33-12.63 years), and the 2 azygous coils had dwell times of 1.33 and 6.04 years. In case 1, the azygous coil was inferior to the cardiac silhouette, while in case 2 it was superior. A 14F laser sheath was employed to remove both azygous coils. Both extractions were a complete procedural success in which all leads were removed completely without intraoperative complications. CONCLUSION: These cases demonstrate the variable courses of azygous coils, provide proof of concept that they can be removed safely, and illustrate that azygous coils can be removed with the same techniques that are commonly used to remove other types of leads.

SELECTION OF CITATIONS
SEARCH DETAIL
...