Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
J Nucl Med ; 64(10): 1540-1549, 2023 10.
Article in English | MEDLINE | ID: mdl-37474272

ABSTRACT

PET imaging using the somatostatin receptor 2 (SSTR2) antagonist satoreotide trizoxetan (SSO-120, previously OPS-202) could offer accurate tumor detection and screening for SSTR2-antagonist radionuclide therapy in patients with SSTR2-expressing small cell lung cancer (SCLC). The aim of this single-center study was to investigate tumor uptake and detection rates of 68Ga-SSO-120 in comparison to 18F-FDG PET in the initial staging of SCLC patients. Methods: Patients with newly diagnosed SCLC who underwent additional whole-body 68Ga-SSO-120 PET/CT during the initial diagnostic workup were retrospectively included. The mean administered activity was 139 MBq, and the mean uptake time was 60 min. Gold-standard staging 18F-FDG PET/CT was evaluated if available within 2 wk before or after 68Ga-SSO-120 PET if morphologic differences in CT images were absent. 68Ga-SSO-120- or 18F-FDG-positive lesions were reported in 7 anatomic regions (primary tumor, thoracic lymph node metastases, and distant metastases including pleural, contralateral pulmonary, liver, bone, and other) according to the TNM classification for lung cancer (eighth edition). Consensus TNM staging (derived from CT, endobronchial ultrasound-guided transbronchial needle aspiration, PET, and brain MRI) by a clinical tumor board served as the reference standard. Results: Thirty-one patients were included, 12 with limited and 19 with extensive disease according to the Veterans Administration Lung Study Group classification. 68Ga-SSO-120-positive tumor was detected in all patients (100%) and in 90 of the 217 evaluated regions (41.5%). Thirteen patients (42.0%) had intense average 68Ga-SSO-120 uptake (region-based mean SUVmax ≥ 10); 28 patients (90.3%) had average 68Ga-SSO-120 uptake greater than liver uptake (region-based mean peak tumor-to-liver ratio > 1). In 25 patients with evaluable 18F-FDG PET, primary tumor, thoracic lymph node metastases, and distant metastases were detected in 100%, 92%, and 64%, respectively, of all investigated patients by 68Ga-SSO-120 and in 100%, 92%, and 56%, respectively, by 18F-FDG PET. 68Ga-SSO-120 PET detected additional contralateral lymph node, liver, and brain metastases in 1, 1, and 2 patients, respectively (no histopathology available), and 18F-FDG PET detected additional contralateral lymph node metastases in 3 patients (1 confirmed, 1 systematic endobronchial ultrasound-guided transbronchial needle aspiration-negative, and 1 without available histopathology). None of these differences altered Veterans Administration Lung Study Group staging. The region-based monotonic correlation between 68Ga-SSO-120 and 18F-FDG uptake was low (Spearman ρ = 0.26-0.33). Conclusion: 68Ga-SSO-120 PET offers high diagnostic precision with comparable detection rates and additional complementary information to the gold standard, 18F-FDG PET. Consistent uptake in most patients warrants exploration of SSTR2-directed radionuclide therapy.


Subject(s)
Lung Neoplasms , Small Cell Lung Carcinoma , Humans , Positron Emission Tomography Computed Tomography/methods , Small Cell Lung Carcinoma/diagnostic imaging , Retrospective Studies , Fluorodeoxyglucose F18 , Gallium Radioisotopes , Lymphatic Metastasis , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Neoplasm Staging
3.
Clin Nucl Med ; 48(1): e16-e18, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36469074

ABSTRACT

ABSTRACT: Adenoid cystic carcinomas are the second most common entity of tracheal malignancies, which have an overall incidence as low as only 0.2 in 100,000 persons per year. We present the case of a 64-year-old man with a histologically confirmed adenoid cystic carcinoma who sequentially underwent 18F-FDG PET/CT and 68Ga-PSMA-11 PET/CT within 1 day for staging 3 days before surgical resection of the tumor. Immunohistochemistry revealed PSMA expression of the tumor corroborating the PSMA PET findings.


Subject(s)
Carcinoma, Adenoid Cystic , Tracheal Neoplasms , Male , Humans , Middle Aged , Positron Emission Tomography Computed Tomography/methods , Carcinoma, Adenoid Cystic/diagnostic imaging , Carcinoma, Adenoid Cystic/pathology , Fluorodeoxyglucose F18 , Tracheal Neoplasms/diagnostic imaging , Gallium Radioisotopes
4.
Leukemia ; 36(12): 2845-2852, 2022 12.
Article in English | MEDLINE | ID: mdl-36241697

ABSTRACT

The randomized PETAL trial failed to demonstrate a benefit of interim FDG-PET (iPET)-based treatment intensification over continued standard therapy with CHOP (plus rituximab (R) in CD20-positive lymphomas). We hypothesized that PET analysis of all lymphoma manifestations may identify patients who benefitted from treatment intensification. A previously developed neural network was employed for iPET analysis to identify the highest pathological FDG uptake (max-SUVAI) and the mean FDG uptake of all lymphoma manifestations (mean-SUVAI). High mean-SUVAI uptake was determined separately for iPET-positive and iPET-negative patients. The endpoint was time-to-progression (TTP). There was a significant interaction of additional rituximab and mean-SUVAI in the iPET-negative group (HR = 0.6, p < 0.05). Patients with high mean-SUVAI had significantly prolonged TTP when treated with 6xR-CHOP + 2 R (not reached versus 52 months, p < 0.05), whereas max-SUVmanual failed to show an impact of additional rituximab. In the iPET-positive group, patients with high mean-SUVAI had a significantly longer TTP with (R-)CHOP than with the Burkitt protocol (14 versus 4 months, p < 0.01). Comprehensive iPET evaluation may provide new prognosticators in aggressive lymphoma. Additional application of rituximab was associated with prolonged TTP in iPET-negative patients with high mean-SUVAI. Comprehensive iPET interpretation could identify high-risk patients who benefit from study-specific interventions.


Subject(s)
Fluorodeoxyglucose F18 , Lymphoma, Non-Hodgkin , Humans , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Cyclophosphamide/therapeutic use , Doxorubicin/therapeutic use , Lymphoma, Non-Hodgkin/diagnostic imaging , Lymphoma, Non-Hodgkin/drug therapy , Positron-Emission Tomography/methods , Prednisone/therapeutic use , Rituximab , Vincristine/therapeutic use
5.
Radiologie (Heidelb) ; 62(10): 875-884, 2022 Oct.
Article in German | MEDLINE | ID: mdl-36112174

ABSTRACT

The theranostic principle describes the diagnostic and therapeutic use of radioactive nuclides linked to biochemically active ligands. The oldest and most prominent field of application of theranostics in oncology is differentiated thyroid cancer treated by radioiodine therapy, which allows imaging of the iodine uptake and thus tumor manifestations by gamma (γ) radiation of radioiodine. Other areas of application include neuroendocrine tumors, castration-resistant prostate cancer and, in the context of individual therapeutic approaches, fibroblastic tumors. Imaging with beta-plus (ß+) emitters is mainly performed using so-called hybrid imaging: positron emission tomography (PET) in combination with computed tomography or magnetic resonance imaging (PET/CT or PET/MRI). Beta-minus (ß-) emitters are predominantly used in therapy, but the use of alpha (α) emitters is also increasing, thus, enabling targeted cancer treatment with mostly low-grade side effects.


Subject(s)
Nuclear Medicine , Prostatic Neoplasms , Humans , Iodine Radioisotopes/therapeutic use , Ligands , Male , Positron Emission Tomography Computed Tomography/methods , Positron-Emission Tomography , Precision Medicine , Prostatic Neoplasms/drug therapy , Radiopharmaceuticals/therapeutic use , Theranostic Nanomedicine/methods
6.
Clin Nucl Med ; 47(11): e718-e721, 2022 11 01.
Article in English | MEDLINE | ID: mdl-35714372

ABSTRACT

ABSTRACT: Ventilation/perfusion SPECT/CT has very high sensitivity with little false-positive findings for diagnosing pulmonary embolism (PE). However, bronchopulmonary tumors or structural changes of the lungs' vasculature infrequently mimic PE. Here, a 59-year-old man presented with acute dyspnea and acute renal failure 5 years after bilateral lung transplant. Pulmonary ventilation/perfusion SPECT/CT was performed demonstrating a lobar mismatch of the left upper lung lobe indicative for PE. Bronchoscopy revealed local hyperemia of this lobe, indicating prolonged venous blood return. Subsequent CT angiography confirmed postsurgical upper pulmonary vein obliteration as final diagnosis. In conclusion, pulmonary vein obliteration might cause false-positive ventilation/perfusion SPECT/CT.


Subject(s)
Lung Transplantation , Pulmonary Embolism , Humans , Lung/diagnostic imaging , Lung Transplantation/adverse effects , Male , Middle Aged , Perfusion , Pulmonary Embolism/diagnostic imaging , Tomography, Emission-Computed, Single-Photon , Tomography, X-Ray Computed , Ventilation-Perfusion Ratio
7.
Semin Nucl Med ; 52(6): 816-823, 2022 11.
Article in English | MEDLINE | ID: mdl-35624033

ABSTRACT

Malignant pleural mesothelioma is a rare type of cancer, whose incidence, however, is increasing and will presumably continue to rise in the coming years. Key features of this disease comprise its mantle-shaped, pleura-associated, often multifocal growth, which cause diagnostic challenges. A growing number of mesotheliomas are being treated with novel immunotherapies for which no image derived general response criteria have been established. However, recent studies indicate that FDG-PET/CT could be superior for response assessment compared to CT-based criteria. This article aims at providing an overview of response assessment criteria dedicated to malignant pleural mesothelioma, such as mRECIST, iRECIST, and PERCIST. In addition, the potential future role of PET/CT in the management of malignant pleural mesothelioma will also be discussed.


Subject(s)
Mesothelioma, Malignant , Mesothelioma , Pleural Neoplasms , Humans , Mesothelioma, Malignant/diagnostic imaging , Positron Emission Tomography Computed Tomography , Pleural Neoplasms/diagnostic imaging , Pleural Neoplasms/therapy , Fluorodeoxyglucose F18 , Mesothelioma/diagnostic imaging , Mesothelioma/therapy , Positron-Emission Tomography
8.
J Nucl Med ; 63(5): 746-753, 2022 05.
Article in English | MEDLINE | ID: mdl-34446454

ABSTRACT

Molecular tumor volume (MTV) is a parameter of interest in prostate cancer for assessing total disease burden on prostate-specific membrane antigen (PSMA) PET. Although software segmentation tools can delineate whole-body MTV, a necessary step toward meaningful monitoring of total tumor burden and treatment response through PET is establishing the repeatability of these metrics. The present study assessed the repeatability of total MTV and related metrics for 68Ga-PSMA-HBED-CC in prostate cancer. Methods: Eighteen patients from a prior repeatability study who underwent 2 test-retest PSMA PET/CT scans within a mean interval of 5 d were reanalyzed. Within-subject coefficient of variation and repeatability coefficients (RCs) were analyzed on a per-lesion and per-patient basis. For the per-lesion analysis, individual lesions were segmented for analysis by a single reader. For the per-patient analysis, subgroups of up to 10 lesions (single reader) and the total tumor volume per patient were segmented (independently by 2 readers). Image parameters were MTV, SUVmax, SUVpeak, SUVmean, total lesion PSMA, and the related metric PSMA quotient (which integrates lesion volume and PSMA avidity). Results: In total, 192 segmentations were analyzed for the per-lesion analysis and 1,662 segmentations for the per-patient analysis (combining the 2 readers and 2 scans). The RC of the MTV of single lesions was 77% (95% CI, 63%-96%). The RC improved to 33% after aggregation of up to 10 manually selected lesions into subgroups assessed per patient (95% CI, 25%-46%). The RC of the semiautomatic MTVtotal (the sum of all voxels in the whole-body total tumor segmentation per patient) was 35% (95% CI, 25%-50%), the Bland-Altman bias was -6.70 (95% CI, -14.32-0.93). Alternating readers between scans led to a comparable RC of 37% (95% CI, 28%-49%) for MTVtotal, meaning that the metric is robust between scanning sessions and between readers. Conclusion:68Ga-PSMA-HBED-CC PET-derived semiautomatic MTVtotal is repeatable and reader-independent, with a change of ±35% representing a true change in tumor volume. Volumetry of single manually selected lesions has considerably lower repeatability, and volumetry based on subgroups of these lesions, although showing acceptable repeatability, is less systematic. The semiautomatic analysis of MTVtotal used in this study offers an efficient and robust means of assessing response to therapy.


Subject(s)
Positron Emission Tomography Computed Tomography , Prostatic Neoplasms , Edetic Acid/analogs & derivatives , Gallium Isotopes , Gallium Radioisotopes , Humans , Male , Positron Emission Tomography Computed Tomography/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Tumor Burden
9.
J Nucl Med ; 63(9): 1349-1356, 2022 09.
Article in English | MEDLINE | ID: mdl-34916249

ABSTRACT

Cerenkov luminescence imaging (CLI) was successfully implemented in the intraoperative context as a form of radioguided cancer surgery, showing promise in the detection of surgical margins during robot-assisted radical prostatectomy. The present study was designed to provide a quantitative description of the occupational radiation exposure of surgery and histopathology personnel from CLI-guided robot-assisted radical prostatectomy after the injection of 68Ga-PSMA-11 in a single-injection PET/CT CLI protocol. Methods: Ten patients with preoperative 68Ga-PSMA-11 administration and intraoperative CLI were included. Patient dose rate was measured before PET/CT (n = 10) and after PET/CT (n = 5) at a 1-m distance for 4 patient regions (head [A], right side [B], left side [C], and feet [D]). Electronic personal dosimetry (EPD) was used for intraoperative occupational exposure (n = 10). Measurements included the first surgical assistant and scrub nurse at the operating table and the CLI imager/surgeon at the robotic console and encompassed the whole duration of surgery and CLI image acquisition. An estimation of the exposure of histopathology personnel was performed by measuring prostate specimens (n = 8) with a germanium detector. Results: The measured dose rate value before PET/CT was 5.3 ± 0.9 (average ± SD) µSv/h. This value corresponds to a patient-specific dose rate constant for positions B and C of 0.047 µSv/h⋅MBq. The average dose rate value after PET/CT was 1.04 ± 1.00 µSv/h. The patient-specific dose rate constant values corresponding to regions A to D were 0.011, 0.026, 0.024, and 0.003 µSv/h⋅MBq, respectively. EPD readings revealed average personal equivalent doses of 9.0 ± 7.1, 3.3 ± 3.9, and 0.7 ± 0.7 µSv for the first surgical assistant, scrub nurse, and CLI imager/surgeon, respectively. The median germanium detector-measured activity of the prostate specimen was 2.96 kBq (interquartile range, 2.23-7.65 kBq). Conclusion: Single-injection 68Ga-PSMA-11 PET/CT CLI procedures are associated with a reasonable occupational exposure level, if kept under 110 procedures per year. Excised prostate specimen radionuclide content was below the exemption level for 68Ga. Dose rate-based calculations provide a robust estimation for EPD measurements.


Subject(s)
Germanium , Occupational Exposure , Prostatic Neoplasms , Radiation Protection , Robotics , Gallium Isotopes , Gallium Radioisotopes , Humans , Luminescence , Male , Positron Emission Tomography Computed Tomography , Prostatectomy , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Prostatic Neoplasms/surgery , Radioisotopes
10.
Sci Rep ; 11(1): 17477, 2021 09 01.
Article in English | MEDLINE | ID: mdl-34471170

ABSTRACT

The radioiodine isotope pair 124I/131I is used in a theranostic approach for patient-specific treatment of differentiated thyroid cancer. Lesion detectability is notably higher for 124I PET (positron emission tomography) than for 131I gamma camera imaging but can be limited for small and low uptake lesions. The recently introduced silicon-photomultiplier-based (SiPM-based) PET/CT (computed tomography) systems outperform previous-generation systems in detector sensitivity, coincidence time resolution, and spatial resolution. Hence, SiPM-based PET/CT shows an improved detectability, particularly for small lesions. In this study, we compare the size-dependant minimum detectable 124I activity (MDA) between the SiPM-based Biograph Vision and the previous-generation Biograph mCT PET/CT systems and we attempt to predict the response to 131I radioiodine therapy of lesions additionally identified on the SiPM-based system. A tumour phantom mimicking challenging conditions (derived from published patient data) was used; i.e., 6 small spheres (diameter of 3.7-9.7 mm), 9 low activity concentrations (0.25-25 kBq/mL), and a very low signal-to-background ratio (20:1). List-mode emission data (single-bed position) were divided into frames of 4, 8, 16, and 30 min. Images were reconstructed with ordinary Poisson ordered-subsets expectation maximization (OSEM), additional time-of-flight (OSEM-TOF) or TOF and point spread function modelling (OSEM-TOF+PSF). The signal-to-noise ratio and the MDA were determined. Absorbed dose estimations were performed to assess possible treatment response to high-activity 131I radioiodine therapy. The signal-to-noise ratio and the MDA were improved from the mCT to the Vision, from OSEM to OSEM-TOF and from OSEM-TOF to OSEM-TOF+PSF reconstructed images, and from shorter to longer emission times. The overall mean MDA ratio of the Vision to the mCT was 0.52 ± 0.18. The absorbed dose estimations indicate that lesions ≥ 6.5 mm with expected response to radioiodine therapy would be detectable on both systems at 4-min emission time. Additional smaller lesions of therapeutic relevance could be detected when using a SiPM-based PET system at clinically reasonable emission times. This study demonstrates that additional lesions with predicted response to 131I radioiodine therapy can be detected. Further clinical evaluation is warranted to evaluate if negative 124I PET scans on a SiPM-based system can be sufficient to preclude patients from blind radioiodine therapy.

11.
Semin Nucl Med ; 50(5): 465-470, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32768009

ABSTRACT

Colorectal cancer is the cancer with the third highest incidence both in males and females in the USA and is also frequently occurring in other industrialized nations. Anal cancer on the other hand is much rarer, but has a rising incidence, especially in high income nations and with a connection to HIV infections, homosexual men and a younger age of the first sexual encounter. Both have high mortality rates in common and are complex to handle in terms of prevention, staging, treatment and diagnostic of recurrence. This article aims to give an overview about the established diagnostic methods of nuclear medicine, especially sole PET and (contrast enhanced) hybrid imaging with 18F-FDG as tracer for primary staging, restaging, therapy monitoring and radiotherapy planning in current guidelines, with a special focus on the American guidelines of the National Comprehensive Cancer Network for colorectal and anal cancer. There will also be an outlook on potential future adjustments in those leading to a more significant representation of nuclear medicine by giving a synopsis of the available studies and data published in international medical press. New tracers that are still in research stage, progress in the imaging techniques, for example a further establishment of PET/MR hybrid imaging, the use of artificial intelligence and parametric imaging, as well as possible future theranostic applications like c-MET binding peptides will also be shortly discussed.


Subject(s)
Anus Neoplasms/diagnostic imaging , Anus Neoplasms/therapy , Colorectal Neoplasms/diagnostic imaging , Colorectal Neoplasms/therapy , Molecular Imaging , Anus Neoplasms/radiotherapy , Colorectal Neoplasms/radiotherapy , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...