Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Article in English | MEDLINE | ID: mdl-36933787

ABSTRACT

OBJECTIVE: Evaluate the feasibility of prophylactic radiofrequency isolation of the pulmonary veins, with left atrial appendage amputation, to reduce the incidence of postoperative atrial fibrillation (POAF) after cardiac surgery in patients aged 70 and older. METHODS: The Federal Food and Drug Administration granted an investigational device exemption to utilize a bipolar radiofrequency clamp for prophylactic pulmonary vein isolation in a limited, feasibility trial. Sixty-two patients without prior dysrhythmias, were prospectively randomized to undergo either their index cardiac surgical procedure, or bilateral pulmonary vein isolation and left atrial appendage amputation during their cardiac operation. The primary outcome was occurrence of in-hospital POAF. Subjects were on 24-hour telemetry until discharge. Dysrhythmias, any episode of atrial fibrillation > 30 seconds, were confirmed by electrophysiologists blinded to the study. RESULTS: Sixty patients, mean age 75 years and mean CHA2DS2-VASc score 4, were analyzed. Thirty-one patients randomized to control and twenty-nine to the treatment group. Majority of cases in each group were isolated CABG. No perioperative complications related to the treatment procedure, need for permanent pacemaker, or mortality occurred. The in-hospital incidence of POAF was 55% (17/31) in the control group and 7% (2/29) in the treatment group. (p<0.001) The control group had a significantly higher requirement for antiarrhythmic medications at discharge, 45% (14/31) vs 7% (2/29) in the treatment group (p<0.001). CONCLUSIONS: Prophylactic radiofrequency isolation of the pulmonary veins with left atrial appendage amputation, during the primary cardiac surgical operation, reduced the incidence of POAF in patients 70 years and older with no history of atrial arrhythmias.

2.
Circ Cardiovasc Interv ; 14(4): e009927, 2021 04.
Article in English | MEDLINE | ID: mdl-33719506

ABSTRACT

BACKGROUND: Despite the rapid adoption of transcatheter aortic valve replacement (TAVR) since its initial approval in 2011, the frequency and outcomes of surgical explantation of TAVR devices (TAVR-explant) is poorly understood. METHODS: Patients undergoing TAVR-explant between January 2012 and June 2020 at 33 hospitals in Michigan were identified in the Society of Thoracic Surgeons Database and linked to index TAVR data from the Transcatheter Valve Therapy Registry through a statewide quality collaborative. The primary outcome was operative mortality. Indications for TAVR-explant, contraindications to redo TAVR, operative data, and outcomes were collected from Society of Thoracic Surgeons and Transcatheter Valve Therapy databases. Baseline Society of Thoracic Surgeons Predicted Risk of Mortality was compared between index TAVR and TAVR-explant. RESULTS: Twenty-four surgeons at 12 hospitals performed TAVR-explants in 46 patients (median age, 73). The frequency of TAVR-explant was 0.4%, and the number of explants increased annually. Median time to TAVR-explant was 139 days and among known device types explanted, most were self-expanding valves (29/41, 71%). Common indications for TAVR-explant were procedure-related failure (35%), paravalvular leak (28%), and need for other cardiac surgery (26%). Contraindications to redo TAVR included need for other cardiac surgery (28%), unsuitable noncoronary anatomy (13%), coronary obstruction (11%), and endocarditis (11%). Overall, 65% (30/46) of patients underwent concomitant procedures, including aortic repair/replacement in 33% (n=15), mitral surgery in 22% (n=10), and coronary artery bypass grafting in 16% (n=7). The median Society of Thoracic Surgeons Predicted Risk of Mortality was 4.2% at index TAVR and 9.3% at TAVR-explant (P=0.001). Operative mortality was 20% (9/46) and 76% (35/46) of patients had in-hospital complications. Of patients alive at discharge, 37% (17/37) were discharged home and overall 3-month survival was 73±14%. CONCLUSIONS: TAVR-explant is rare but increasing, and its clinical impact is substantial. As the utilization of TAVR expands into younger and lower-risk patients, providers should consider the potential for future TAVR-explant during selection of an initial valve strategy.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
3.
Semin Thorac Cardiovasc Surg ; 30(3): 262-268, 2018.
Article in English | MEDLINE | ID: mdl-29158054

ABSTRACT

Transcatheter aortic valve replacement (TAVR) is used increasingly to treat bioprosthetic valve failure. A paucity of data exists regarding valve-in-valve (ViV) TAVR in degenerated Freestyle stentless bioprostheses (FSBs). This study sought to evaluate the feasibility and short-term outcomes of ViV TAVR in previously placed FSB. From October 2014 to September 2016, 22 patients at a single institution underwent ViV TAVR with a self-expanding transcatheter valve for a failing FSB. Patient baseline characteristics and clinical outcomes data were collected retrospectively and entered into a dedicated database. The mean patient age was 74 ± 9 years, and the mean Society of Thoracic Surgeons' Risk score was 9.0 ± 7.4%. Ten patients presented with acute heart failure requiring urgent intervention. The most common mode of failure of the FSB was regurgitation caused by a flail or malcoapting leaflet. Seventeen (77%) patients had a modified subcoronary implantation, 3 (14%) had a full root replacement, and 2 (9%) had a root inclusion. Device success using a self-expanding transcatheter valve was 95%, all via transfemoral approach. The mean implant depth was 7 ± 3 mm. Thirty-day survival was 100%. No patient had more than mild paravalvular regurgitation at 30 days, and the permanent pacemaker rate was 9%. The mean hospital stay after intervention was 5 ± 2 days. ViV TAVR using a self-expanding transcatheter valve is safe, feasible, and can be used successfully to treat a failed FSB. Procedural challenges suggest referral to valve centers of excellence.


Subject(s)
Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Prosthesis Failure , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Feasibility Studies , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
5.
Biochemistry ; 42(47): 13787-99, 2003 Dec 02.
Article in English | MEDLINE | ID: mdl-14636045

ABSTRACT

Fluorescent-labeled derivatives of the Antennapedia-derived cell-penetating peptide penetratin, and of the simpler but similarly charged peptides R(6)GC-NH(2) and K(6)GC-NH(2), are shown to be able to translocate into large unilamellar lipid vesicles in the presence of a transbilayer potential (inside negative). Vesicles with diverse lipid compositions, and combining physiological proportions of neutral and anionic lipids, are able to support substantial potential-dependent uptake of all three cationic peptides. The efficiency of peptide uptake under these conditions is strongly modulated by the vesicle lipid composition, in a manner that suggests that more than one mechanism of peptide uptake may operate in different systems. Remarkably, peptide uptake is accompanied by only minor perturbations of the overall barrier function of the lipid bilayer, as assessed by assays of vesicle leakiness under the same conditions. Fluorescence microscopy of living CV-1 and HeLa cells incubated with the labeled peptides shows that the peptides accumulate in peripheral vesicular structures at early times of incubation, consistent with an initial endosomal localization as recently reported, but gradually accumulate in the cytoplasm and nucleus during more extended incubations (several hours). Our findings indicate that these relatively hydrophilic, polybasic cell-penetrating peptides can translocate through lipid bilayers by a potential- and composition-dependent pathway that causes only minimal perturbation to the overall integrity and barrier function of the bilayer.


Subject(s)
Carrier Proteins/chemistry , Cell Membrane Permeability/physiology , Drosophila Proteins/chemistry , Homeodomain Proteins/chemistry , Lipid Bilayers/chemistry , Nuclear Proteins , Peptide Fragments/chemistry , Transcription Factors , Amino Acid Sequence , Animals , Antennapedia Homeodomain Protein , Carrier Proteins/metabolism , Cell Line , Cell-Penetrating Peptides , Chlorocebus aethiops , Drosophila Proteins/metabolism , HeLa Cells , Homeodomain Proteins/metabolism , Humans , Lipid Bilayers/metabolism , Membrane Potentials , Molecular Sequence Data , Peptide Fragments/metabolism , Phosphatidylcholines/chemistry , Phosphatidylethanolamines/chemistry , Phosphatidylglycerols/chemistry , Protein Transport , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL