Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cancer Immunol Immunother ; 72(8): 2865-2871, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37093243

ABSTRACT

We previously conducted a randomized phase II trial of OCV-501, a WT1 peptide presented by helper T cells, in elderly AML (acute myeloid leukemia) patients in first remission, indicating no difference in 2-year disease-free survival (DSF) between the OCV-501 and placebo groups. Here, we analyzed 5-year outcome and biomarkers. Five-year DFS was 36.0% in the OCV-501 group (N = 52) and 33.7% in the placebo group (N = 53), with no significant difference (p = 0.74). The peripheral WT1 mRNA levels were marginally suppressed in the OCV-501 group compared with the placebo group. Enhanced anti-OCV-501 IgG response by the 25th week was an independent favorable prognostic factor. Anti-OCV-501 IFNγ responses were less frequent than the IgG reactions. These findings suggest that host immunoreactivity has a significant impact on the prognosis of AML and that further improvement of the WT1 peptide vaccine is needed.


Subject(s)
Leukemia, Myeloid, Acute , WT1 Proteins , Humans , Aged , Follow-Up Studies , Prognosis , Leukemia, Myeloid, Acute/genetics , Vaccines, Subunit/therapeutic use , Immunoglobulin G
2.
Anal Chem ; 76(24): 7294-303, 2004 Dec 15.
Article in English | MEDLINE | ID: mdl-15595872

ABSTRACT

2-Aminopyridine (PA)-derivatized oligosaccharides from IgG were analyzed by using reversed-phase HPLC/mass spectrometry (RP-HPLC/MS) and a MS(n) spectral library, in particular, focusing on two pairs of isomers incompletely separated or coeluted in chromatograms. We previously reported that MS(n) spectral matching considering both major fragment ions (m/z) and intensities is useful and applicable to the structural assignment of PA-oligosaccharide isomers. In this study, MS(n) spectral matching based on the MS(n) spectral library was applied to the assignment of these PA-oligosaccharide isomers in IgG. Its usefulness was investigated by comparing it to the conventional two-dimensional mapping method based on retention time indexes. Specifically, we focus on the assignment and quantification of the isomers, which are coeluted in chromatograms. From this, we propose a new method using MS(n) spectral matching and the working curve on which are plotted the relative intensities of selected fragment ions in their MS(2) spectra versus various mixtures of the isomers. This new method demonstrated that the obtained quantities coincide very well with those estimated after separating by a combination of lectin and reversed-phase columns. This means that separation by RP-HPLC/MS is greatly simplified because complete separation of the isomers is no longer required. Application of this new method was tested by using the two other pairs of fucosylated and nonfucosylated PA-oligosaccharides from IgG. The results showed that this method works for them as well.


Subject(s)
Aminopyridines/analysis , Chromatography, High Pressure Liquid/methods , Mass Spectrometry/methods , Oligosaccharides/analysis , Aminopyridines/chemistry , Carbohydrate Sequence , Fucose/analogs & derivatives , Immunoglobulin G/chemistry , Isomerism , Models, Molecular , Molecular Sequence Data , Oligosaccharides/chemistry , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL