Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 486
Filter
1.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-39031021

ABSTRACT

AIMS: Ventricular tachycardia (VT) non-inducibility in response to programmed ventricular stimulation (PVS) is a widely used procedural endpoint for VT ablation despite inconclusive evidence with respect to clinical outcomes in high-risk patients. The aim is to determine the utility of acute post-ablation VT inducibility as a predictor of VT recurrence, mortality, or mortality equivalent in high-risk patients. METHODS AND RESULTS: We conducted a retrospective analysis of high-risk patients (defined as PAINESD > 17) who underwent scar-related VT ablation at our institution between July 2010 and July 2022. Patients' response to PVS (post-procedure) was categorized into three groups: Group A, no clinical VT or VT with cycle length > 240 ms inducible; Group B, only non-clinical VT with cycle length > 240 ms induced; and Group C, all other outcomes (including cases where no PVS was performed). The combined primary endpoint included death, durable left ventricular assist device placement, and cardiac transplant (Cox analysis). Ventricular tachycardia recurrence was considered a secondary endpoint (competing risk analysis). Of the 1677 VT ablation cases, 123 cases met the inclusion criteria for analysis. During a 19-month median follow-up time (interquartile range 4-43 months), 82 (66.7%) patients experienced the composite primary endpoint. There was no difference between Groups A and C with respect to the primary [hazard ratio (HR) = 1.21 (0.94-1.57), P = 0.145] or secondary [HR = 1.18 (0.91-1.54), P = 0.210] outcomes. These findings persisted after multivariate adjustments. The size of Group B (n = 13) did not permit meaningful statistical analysis. CONCLUSION: The results of post-ablation PVS do not significantly correlate with long-term outcomes in high-risk (PAINESD > 17) VT ablation patients.


Subject(s)
Catheter Ablation , Cicatrix , Recurrence , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/diagnosis , Male , Female , Retrospective Studies , Middle Aged , Cicatrix/physiopathology , Cicatrix/etiology , Aged , Risk Assessment , Treatment Outcome , Risk Factors
2.
Circ Arrhythm Electrophysiol ; : e012814, 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39051118

ABSTRACT

BACKGROUND: During pulsed field ablation (PFA), relationships between ablation parameters (contact force [CF], number of burst pulses, impedance decrease, and electrode temperature) and lesion size in beating hearts have not been well validated. METHODS: A 7F-catheter with a 3.5-mm ablation electrode and CF sensor (ThermoCool SmartTouch SF-Dual-Energy, Biosense Webster, Inc, Irwindale, CA) was connected to a PFA system (TRUPULSE2, Biosense Webster, Inc). In 11 closed-chest swine, biphasic PFA current was delivered between the ablation electrode and the skin patch at 219 sites in left ventricle and right ventricle using 12, 18, and 24 burst pulses with 4 different levels of CF: (1) low (n=57; CF, 4-15g; median, 10g); (2) moderate (n=60; CF, 16-30g; median, 22.5g); (3) high (n=68; CF, 32-65g; median, 40g); and (4) no electrode contact (n=34), 2 mm away from the endocardium. Swine were euthanized 2 hours after ablation, and lesion size was measured using triphenyl tetrazolium chloride staining. RESULTS: All PFA lesions with electrode-myocardium contact were well demarcated with triphenyl tetrazolium chloride staining, demonstrating (1) pale central zone (contraction band necrosis with minimal coagulation necrosis), (2) dark brown zone (contraction band necrosis with hemorrhage), and (3) hyperstained red zone by triphenyl tetrazolium chloride (unaffected normal myocardium with preserved mitochondrial activity, consistent with reversible zone). Lesion depth increased significantly with increasing CF and the number of PFA burst pulses. An exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlated lesion depth with high accuracy: R=0.809, P<0.0001, ±1.0-mm accuracy in 128 of 163 (79%) lesions, and ±1.5-mm accuracy in 153 of 163 (94%) lesions. Impedance decrease and electrode temperature were poor predictors of lesion size. There were no detectable lesions resulting from ablation without electrode contact. CONCLUSIONS: Acute PFA ventricular lesions demonstrate irreversible and reversible lesion boundaries. Electrode-tissue contact is required for effective lesion formation. Lesion depth increases significantly with increasing CF and PFA burst pulses. A new exponential/logarithmic formula combined with CF and the number of PFA burst pulses correlates lesion depth with high accuracy.

3.
Article in English | MEDLINE | ID: mdl-38878012

ABSTRACT

BACKGROUND: Purkinje fibers play an important role in initiation and maintenance of ventricular fibrillation (VF) and polymorphic ventricular tachycardia (PMVT). Fascicular substrate modification (FSM) approaches have been suggested to treat recurrent VF in case reports and small case series. OBJECTIVES: The aim of this study was to investigate outcomes of catheter-based FSM to treat VF and PMVT. METHODS: Of 2,212 consecutive patients with ventricular arrhythmia undergoing catheter ablation, 18 (0.81%) underwent FSM of the Purkinje fibers as identified with high-density mapping during sinus rhythm. Fascicular substrate and VF initiation were mapped using a multipolar catheter. The endpoint of the ablation was noninducibility of VF and PMVT. In select patients, remapping revealed elimination of the targeted Purkinje potentials. Demographic, clinical, and follow-up characteristics were prospectively collected in our institutional database. RESULTS: A total of 18 patients (mean age 56 ± 3.8 years, 22% women) were included in the study. Of those, 11 (61.1%) had idiopathic VF, 3 (16.7%) had nonischemic cardiomyopathy, and 4 (22.2%) had mixed cardiomyopathy. The average left ventricular ejection fraction was 42.5%. At least 2 antiarrhythmic drugs had failed preablation. At baseline, all patients had inducible VF or PMVT. At the end of the procedure, no patient demonstrated new evidence of fascicular block or bundle branch block. There were no procedure-related complications. After a median follow-up period of 24 months, 16 patients (88.9%) were arrhythmia free on or off drugs: 11 of 11 patients (100%) with idiopathic VF vs 5 of 7 patients (71.4%) with underlying cardiomyopathy (P = 0.06). CONCLUSIONS: Catheter ablation of human VF and PMVT with FSM is feasible and safe and appears highly effective, with high rates of acute VF noninducibility and long-term freedom from recurrent VF.

4.
Article in English | MEDLINE | ID: mdl-38878017

ABSTRACT

BACKGROUND: Comparative efficacy and safety data on radiofrequency ablation (RFA) versus pulsed field ablation (PFA) for common idiopathic left ventricular arrhythmia (LV-VAs) locations are lacking. OBJECTIVES: This study sough to compare RFA with PFA of common idiopathic LV-VAs locations. METHODS: Ten swine were randomized to PFA or RFA of LV interventricular septum, papillary muscle, LV summit via distal coronary sinus, and LV epicardium via subxiphoid approach. Ablations were delivered using an investigational dual-energy (RFA/PFA) contact force (CF) and local impedance-sensing catheter. After 1-week survival, animals were euthanized for lesion assessment. RESULTS: A total of 55 PFA (4 applications/site of 2.0 KV, target CF ≥10 g) and 36 RFA (CF ≥10 g, 25-50 W targeting ≥50 Ω local impedance drop, 60-second duration) were performed. LV interventricular septum: average PFA depth 7.8 mm vs RFA 7.9 mm (P = 0.78) and no adverse events. Papillary muscle: average PFA depth 8.1 mm vs RFA 4.5 mm (P < 0.01). Left ventricular summit: average PFA depth 5.6 mm vs RFA 2.7 mm (P < 0.01). Steam-pop and/or ventricular fibrillation in 4 of 12 RFA vs 0 of 12 PFA (P < 0.01), no ST-segment changes observed. Epicardium: average PFA depth 6.4 mm vs RFA 3.3 mm (P < 0.01). Transient ST-segment elevations/depressions occurred in 4 of 5 swine in the PFA arm vs 0 of 5 in the RFA arm (P < 0.01). Angiography acutely and at 7 days showed normal coronaries in all cases. CONCLUSIONS: In this swine study, compared with RFA, PFA of common idiopathic LV-VAs locations produced deeper lesions with fewer steam pops. However, PFA was associated with higher rates of transient ST-segment elevations and depressions with direct epicardium ablation.

5.
J Arrhythm ; 40(3): 578-584, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38939799

ABSTRACT

Background: Implantable cardioverter-defibrillator (ICD) offers an opportunity to study inducibility of ventricular tachycardia (VT) or ventricular fibrillation (VF) by performing noninvasive programmed ventricular stimulation (NIPS). Whether NIPS can predict future arrhythmic events or mortality in patients with primary prevention ICD, has not yet been examined. Methods: From the NIPS-ICD study (ClinicalTrials ID: NCT02373306) 41 consecutive patients (34 males, age 64 ± 11 years, 76% ischemic cardiomyopathy [ICM]) had ICD for primary prevention indication. Patients underwent NIPS using a standardized protocol of up to three premature extrastimuli at 600, 500 and 400 ms drive cycle lengths. NIPS was classified as positive if sustained VT or VF was induced. The study endpoint was occurrence of sustained VT/VF during the follow-up. Results: At baseline NIPS, VT/VF was induced in 8 (20%) ICM patients. During the 5-year follow-up, the VT/VF occurred in 7 (17%) patients, all with ICM. The difference between NIPS-inducible versus NIPS-noninducible patients regarding VT/VF occurrence did not meet statistical significance (38% vs. 12%, log rank test p = .11). After a 5-year follow-up, the mortality rate was significantly higher in patients who had VT/VF induced at NIPS versus no VT/VF at NIPS (38% vs. 12%, p = .043). The occurrence of a composite endpoint consisting of VT/VF recurrence or death in patients with ICM was also most frequent in the NIPS-inducible group (75% vs. 35%, p = .037). Conclusions: Inducibility of VT/VF during NIPS in ICM patients with primary prevention ICD is associated with higher mortality and higher incidence of composite endpoint consisting of death or VT/VF during a long-term observation.

6.
Heart Rhythm ; 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38942104

ABSTRACT

The complexity of cardiac electrophysiology procedures has increased significantly over the past three decades. Anesthesia requirements of these procedures can be different based on patient- and procedure-specific factors. This manuscript outlines various anesthesia strategies for cardiac implantable electronic devices and electrophysiology procedures including pre-procedural, procedural and post-procedural management. A team-based approach with collaboration between cardiac electrophysiologists and anesthesiologists is required with careful pre-procedural and intra-procedural planning. Given the recent advances in electrophysiology, there is a need for specialized cardiac electrophysiology anesthesia care to improve the efficacy and safety of the procedures.

8.
Article in English | MEDLINE | ID: mdl-38904577

ABSTRACT

BACKGROUND: Current therapies for pulmonary vein stenosis (PVS) or pulmonary vein total occlusion (PVTO) involving angioplasty and stenting are hindered by high rates of restenosis. OBJECTIVES: This study compares a novel approach of drug-coated balloon (DCB) angioplasty and stenting with the current standard of care in PVS or PVTO due to pulmonary vein isolation (PVI). METHODS: A retrospective single-center study analyzed patients with PVS or PVTO due to PVI who underwent either angioplasty and stenting (NoDCB group; December 2012-December 2016) or DCB angioplasty and stenting (DCB group; January 2018-January 2021). Multivariable Andersen-Gill regression analysis assessed the risk of restenosis and target lesion revascularization (TLR). RESULTS: The NoDCB group comprised 58 patients and 89 veins, with a longer median follow-up of 35 months, whereas the DCB group included 26 patients and 33 veins, with a median follow-up of 11 months. The DCB group exhibited more PVTO (NoDCB: 12.3%; DCB: 42.4%; P = 0.0001), with a smaller reference vessel size (NoDCB: 10.2 mm; DCB: 8.4 mm; P = 0.0004). Follow-up computed tomography was performed in 82% of NoDCB and 85% of DCB, revealing lower unadjusted rates of restenosis (NoDCB: 26%; DCB: 14.3%) and TLR (NoDCB: 34.2%; DCB: 10.7%) in the DCB group. DCB use was associated with a significantly lower risk of restenosis and TLR (HR: 0.003: CI: 0.00009-0.118; P = 0.002). CONCLUSIONS: The novel approach of DCB angioplasty followed by stenting is effective and safe and significantly reduces the risk of restenosis and reintervention compared with the standard of care in PVS or PVTO due to PVI.

9.
Article in English | MEDLINE | ID: mdl-38864808

ABSTRACT

BACKGROUND: Epicardial (Epi) access is commonly required during ventricular tachycardia ablation. Conventional Epi (ConvEpi) access targets a "dry" pericardial space presenting technical challenges and risk of complications. Recently, intentional puncture of coronary venous branches with Epi carbon dioxide insufflation (EpiCO2) has been described as a technique to improve Epi access. The safety of this technique relative to conventional methods remains unproven. OBJECTIVES: The authors sought to compare the feasibility and safety of EpiCO2 to ConvEpi access. METHODS: All patients at a high-volume center undergoing Epi access between January 2021 and December 2023 were included and grouped according to ConvEpi or EpiCO2 approach. Access technique was according to the discretion of the operator. RESULTS: Epi access was attempted in 153 cases by 17 different operators (80 ConvEpi vs 73 EpiCO2). There was no difference in success rate whether the ConvEpi or EpiCO2 approach was used (76 [95%] cases vs 67 [91.8%] cases; P = 0.4). Total Epi access time was shorter in the ConvEpi group compared with the EpiCO2 group (16.3 ± 11.6 minutes vs 26.9 ± 12.7 minutes; P < 0.001), though the total procedure duration was similar. Major Epi access-related complications occurred in only the ConvEpi group (6 [7.5%] ConvEpi vs 0 [0%] EpiCo2; P = 0.02). Bleeding ≥80 mL was more frequently observed following ConvEpi access (14 [17.5%] cases vs 4 [5.5%] cases; P = 0.02). After adjusting for age, repeat Epi access, and antithrombotic therapy, EpiCO2 was associated with a reduction in bleeding ≥80 mL (OR: 0.27; 95% CI: 0.08-0.89; P = 0.03). CONCLUSIONS: EpiCO2 access is associated with lower rates of major complication and bleeding when compared with ConvEpi access.

10.
Card Electrophysiol Clin ; 16(2): 187-193, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38749640

ABSTRACT

The epicardial outflow tract can be a site of origin of idiopathic ventricular arrhythmias. These arrhythmias are most commonly perivalvular and can be targeted from within the coronary venous system or from other adjacent structures, such as the right ventricular and left ventricular outflow tracts or the coronary cusp region. The authors report a case of an epicardial idiopathic outflow tract premature ventricular contraction originating from the midseptal epicardial left ventricle. In this case, direct epicardial access was crucial to identify early local activation and achieve successful catheter ablation.


Subject(s)
Catheter Ablation , Pericardium , Ventricular Premature Complexes , Adult , Female , Humans , Electrocardiography , Heart Ventricles/surgery , Heart Ventricles/physiopathology , Pericardium/surgery , Pericardium/physiopathology , Ventricular Premature Complexes/surgery , Ventricular Premature Complexes/physiopathology
11.
Circ Arrhythm Electrophysiol ; 17(6): e012723, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38690671

ABSTRACT

BACKGROUND: Conventional focal radiofrequency catheters may be modified to enable multiple energy modalities (radiofrequency or pulsed field [PF]) with the benefit of contact force (CF) feedback, providing greater flexibility in the treatment of arrhythmias. Information on the impact of CF on lesion formation in PF ablations remains limited. METHODS: An in vivo study was performed with 8 swine using an investigational dual-energy CF focal catheter with local impedance. Experiment I: To evaluate atrial lesion formation, contiguity, and width, a point-by-point approach was used to create an intercaval line. The distance between the points was prespecified at 4±1 mm. Half of the line was created with radiofrequency energy, whereas the other half utilized PF (single 2.0 kV application with a proprietary waveform). Experiment II: To evaluate single application lesion dimensions with a proprietary waveform, discrete ventricular lesions were performed with PFA (single 2.0 kV application) with targeted levels of CF: low, 5 to 15 g; medium, 20 to 30 g; and high, 35 to 45 g. Following 1 week of survival, animals underwent endocardial/epicardial remapping, and euthanasia to enable histopathologic examination. RESULTS: Experiment I: Both energy modalities resulted in a complete intercaval line of transmural ablation. PF resulted in significantly wider lines than radiofrequency: minimum width, 14.9±2.3 versus 5.0±1.6 mm; maximum width, 21.8±3.4 versus 7.3±2.1 mm, respectively; P<0.01 for each. Histology confirmed transmural lesions with both modalities. Experiment II: With PF, lesion depth, width, and volume were larger with higher degrees of CF (depth: r=0.82, P<0.001; width: r=0.26, P=0.052; and volume: r=0.55, P<0.001), with depth increasing at a faster rate than width. The mean depths were as follows: low (n=17), 4.3±1.0 mm; medium (n=26), 6.4±1.2 mm; and high (n=14), 9.1±1.4 mm. CONCLUSIONS: Using the same focal point CF-sensing catheter, a novel PF ablation waveform with a single application resulted in transmural atrial lesions that were significantly wider than radiofrequency. Lesion depth showed a significant positive correlation with CF with depths of 6.4 mm at moderate CF.


Subject(s)
Cardiac Catheters , Catheter Ablation , Equipment Design , Animals , Catheter Ablation/instrumentation , Catheter Ablation/methods , Swine , Heart Atria/physiopathology , Heart Atria/surgery , Models, Animal , Sus scrofa , Heart Ventricles/physiopathology , Heart Ventricles/surgery
12.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38703375

ABSTRACT

AIMS: Ablation of monomorphic ventricular tachycardia (MMVT) has been shown to reduce shock frequency and improve survival. We aimed to compare cause-specific risk factors for MMVT and polymorphic ventricular tachycardia (PVT)/ventricular fibrillation (VF) and to develop predictive models. METHODS AND RESULTS: The multicentre retrospective cohort study included 2668 patients (age 63.1 ± 13.0 years; 23% female; 78% white; 43% non-ischaemic cardiomyopathy; left ventricular ejection fraction 28.2 ± 11.1%). Cox models were adjusted for demographic characteristics, heart failure severity and treatment, device programming, and electrocardiogram metrics. Global electrical heterogeneity was measured by spatial QRS-T angle (QRSTa), spatial ventricular gradient elevation (SVGel), azimuth, magnitude (SVGmag), and sum absolute QRST integral (SAIQRST). We compared the out-of-sample performance of the lasso and elastic net for Cox proportional hazards and the Fine-Gray competing risk model. During a median follow-up of 4 years, 359 patients experienced their first sustained MMVT with appropriate implantable cardioverter-defibrillator (ICD) therapy, and 129 patients had their first PVT/VF with appropriate ICD shock. The risk of MMVT was associated with wider QRSTa [hazard ratio (HR) 1.16; 95% confidence interval (CI) 1.01-1.34], larger SVGel (HR 1.17; 95% CI 1.05-1.30), and smaller SVGmag (HR 0.74; 95% CI 0.63-0.86) and SAIQRST (HR 0.84; 95% CI 0.71-0.99). The best-performing 3-year competing risk Fine-Gray model for MMVT [time-dependent area under the receiver operating characteristic curve (ROC(t)AUC) 0.728; 95% CI 0.668-0.788] identified high-risk (> 50%) patients with 75% sensitivity and 65% specificity, and PVT/VF prediction model had ROC(t)AUC 0.915 (95% CI 0.868-0.962), both satisfactory calibration. CONCLUSION: We developed and validated models to predict the competing risks of MMVT or PVT/VF that could inform procedural planning and future randomized controlled trials of prophylactic ventricular tachycardia ablation. CLINICAL TRIAL REGISTRATION: URL:www.clinicaltrials.gov Unique identifier:NCT03210883.


Subject(s)
Defibrillators, Implantable , Primary Prevention , Tachycardia, Ventricular , Ventricular Fibrillation , Humans , Female , Male , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/prevention & control , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Middle Aged , Retrospective Studies , Primary Prevention/methods , Risk Factors , Risk Assessment , Aged , Ventricular Fibrillation/prevention & control , Ventricular Fibrillation/diagnosis , Ventricular Fibrillation/physiopathology , Ventricular Fibrillation/therapy , Treatment Outcome , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Electrocardiography , Catheter Ablation , Time Factors , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology
15.
JACC Case Rep ; 29(6): 102238, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38549857

ABSTRACT

Cardiac tumors of the left ventricle are rare, and cardiac magnetic resonance is the preferred imaging tool for evaluation given superior tissue characterization. We present a case of a patient with arrhythmia and left ventricular mass that was ultimately diagnosed with cardiac sarcoidosis, reminding us that tissue is the issue.

16.
Pacing Clin Electrophysiol ; 47(5): 595-602, 2024 May.
Article in English | MEDLINE | ID: mdl-38523591

ABSTRACT

BACKGROUND: Data are lacking on patient-reported outcomes (PRO) following cryoballoon ablation (CBA) versus radiofrequency ablation (RFA). We sought to evaluate QoL and clinical outcomes of cryoballoon pulmonary vein isolation only (CRYO-PVI-ONLY) versus RFA with PVI and posterior wall isolation (RF-PVI+PWI) in a large prospective PRO registry. METHODS: Patients who underwent AF ablation (2013-2016) at our institution were enrolled in an automated, prospectively maintained PRO registry. CRYO-PVI-ONLY patients were matched (1:1) with RF-PVI+PWI patients based on age, gender, and type of AF (paroxysmal vs. persistent). QoL and clinical outcomes were assessed using PRO surveys at baseline and at 1-year. The atrial fibrillation symptom severity scale (AFSSS) was the measure for QoL. Additionally, we assessed patient-reported clinical improvement, arrhythmia recurrence, and AF burden (as indicated by AF frequency and duration scores). RESULTS: A total of 296 patients were included (148 in each group, 72% paroxysmal). By PRO, a significant improvement in QoL was observed in the overall study population and was comparable between CRYO-PVI-ONLY and RF-PVI+PWI (baseline median AFSSS of 11.5 and 11; reduced to 2 and 4 at 1 year, respectively; p = 0.44). Similarly, the proportion of patients who reported improvement in their overall QoL and AF related symptoms was high and similar between the study groups [92% (CRYO-PVI-ONLY) vs. 92.8% (RF-PVI+PWI); p = 0.88]. Arrhythmia recurrence was significantly more common in the CRYO-PVI-ONLY group (39.7%) compared to RF-PVI+PWI (27.7 %); p = 0.03. Comparable results were observed in paroxysmal and persistent AF. CONCLUSION: CRYO-PVI-ONLY and RF-PVI+PWI resulted in comparable improvements in patient reported outcomes including QoL and AF burden; with RF-PVI+PWI being more effective at reducing recurrences.


Subject(s)
Atrial Fibrillation , Cryosurgery , Patient Reported Outcome Measures , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Male , Female , Cryosurgery/methods , Atrial Fibrillation/surgery , Middle Aged , Prospective Studies , Heart Atria/surgery , Catheter Ablation/methods , Registries , Quality of Life , Aged , Radiofrequency Ablation/methods
17.
Article in English | MEDLINE | ID: mdl-38499825

ABSTRACT

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

19.
JACC Clin Electrophysiol ; 10(5): 981-999, 2024 May.
Article in English | MEDLINE | ID: mdl-38385913

ABSTRACT

In patients with structural heart disease and ventricular tachycardia (VT) undergoing catheter ablation, the response to programmed electrical stimulation (PES) at the end of the procedure has been traditionally used to evaluate the acute success and predict long-term outcomes. Although noninducibility at PES has been extensively investigated and validated in clinical trials and large multicenter registries, its performance in predicting long-term freedom from VT is suboptimal. In addition, PES has inherent limitations related to the influence of background antiarrhythmic drug therapy, periprocedural use of anesthesia, and the heterogeneity in PES protocols. The increased utilization of substrate-based ablation approaches that focus on ablation of abnormal electrograms identified with mapping in sinus or paced rhythm has been paralleled by a need for additional procedural endpoints beyond VT noninducibility at PES. This article critically appraises the relative merits and limitations of different procedural endpoints according to different ablation techniques for catheter ablation of scar-related VT.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/therapy , Humans , Catheter Ablation/methods , Treatment Outcome , Electrophysiologic Techniques, Cardiac/methods , Electric Stimulation/methods
20.
JACC Case Rep ; 29(4): 102185, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38379643

ABSTRACT

Hypervagotonic sinus node dysfunction (SND) is a form of SND with sinus bradycardia caused by enhanced vagal tone. Indirect proof of hypervagotonia as the mechanism can be inferred from resolution of bradycardia following atropine infusion. In symptomatic patients, pacemaker implantation is recommended. We describe cardioneuroablation as a treatment for hypervagotonic SND.

SELECTION OF CITATIONS
SEARCH DETAIL