Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Int J Food Sci ; 2024: 7310510, 2024.
Article in English | MEDLINE | ID: mdl-38984058

ABSTRACT

Guarana seeds are typically processed using one of three drying methods: traditional sun exposure, greenhouse drying, or the alguidar oven technique. In our research, we evaluated the contents of methylxanthines and flavan-3-ols in sun- and alguidar-dried guarana seeds from Bahia State's Low Sul Identity Territory. Caffeine, theobromine, catechin, and epicatechin were determined by high-performance liquid chromatography with UV-visible detection (HPLC/UV-vis). Statistical tools, including analysis of variance (ANOVA), Tukey's test, and exploratory analysis, were employed to analyze the obtained data. Our findings indicated that the flavan-3-ols content in sun-dried guarana samples was lower compared to those dried using the alguidar oven, possibly due to exposure to ultraviolet radiation from solar energy. Conversely, we observed no significant differences (p > 0.05) in the average contents of methylxanthines between the two drying methods. Our supplementary experiments involving UV-A and UV-C radiation lamps revealed a decreasing trend in methylxanthines and flavan-3-ols contents with increasing duration of UV radiation exposure.

2.
Food Chem ; 273: 136-143, 2019 Feb 01.
Article in English | MEDLINE | ID: mdl-30292359

ABSTRACT

A procedure using ICP OES for sample preparation for the determination of copper, iron and manganese in cashew nuts was developed. Constrained simplex-centroid design was applied in the optimization of the digestion in microwave oven procedure, and the results evaluated from topological maps of the Kohonen network. The best proportion evaluated for the digestion of the sample with HNO3, H2O2 and H2O was 10:45:45 (%). With optimized conditions, the detection limits were 0.63, 4.3 and 0.37 mg kg-1, and quantification 2.1, 14 and 1.2 mg kg-1 for Cu, Fe and Mg, respectively. The precision (% RSD) was 1.84, 2.31 and 2.73, for Cu, Fe and Mg, respectively. The procedure proposed had the accuracy confirmed using NIST 1568b (at 95% reliability) and was applied in the samples obtaining concentrations in the range of 10.7-19.4, 44.3-67.2 and 11.0-21.4 mg kg-1 for Cu, Fe and Mg, respectively.


Subject(s)
Anacardium/chemistry , Food Analysis/methods , Nuts/chemistry , Food Analysis/statistics & numerical data , Hydrogen Peroxide/chemistry , Limit of Detection , Metals/analysis , Microwaves , Multivariate Analysis , Neural Networks, Computer , Reproducibility of Results , Spectrum Analysis/methods , Trace Elements/analysis
SELECTION OF CITATIONS
SEARCH DETAIL