Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
Add more filters










Publication year range
1.
3D Print Addit Manuf ; 10(4): 609-618, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37609578

ABSTRACT

The challenges in reliably removing the sacrificial material from fully enclosed microfluidic channels hinder the use of three-dimensional (3D) printing to create microfluidic devices with intricate geometries. With advances in printer resolution, the etching of sacrificial materials from increasingly smaller channels is poised to be a bottleneck using the existing techniques. In this study, we introduce a microfabrication approach that utilizes centrifugation to effortlessly and efficiently remove the sacrificial materials from 3D-printed microfluidic devices with densely packed microfeatures. We characterize the process by measuring the etch rate under different centrifugal forces and developed a theoretical model to estimate process parameters for a given geometry. The effect of the device layout on the centrifugal etching process is also investigated. We demonstrate the applicability of our approach on devices fabricated using inkjet 3D printing and stereolithography. Finally, the advantages of the introduced approach over commonly used injection-based etching of sacrificial material are experimentally demonstrated in direct comparisons. A robust method to postprocess additively manufactured geometries composed of intricate microfluidic channels can help utilize both the large printing volume and high spatial resolution afforded by 3D printing in creating a variety of devices ranging from scaffolds to large-scale microfluidic assays.

2.
Methods Mol Biol ; 2679: 255-268, 2023.
Article in English | MEDLINE | ID: mdl-37300622

ABSTRACT

Isolation of extremely rare circulating tumor cell (CTC) clusters from the bloodstream of patients enables minimally invasive diagnosis and prognosis while providing information on their role in metastasis. A few technologies specifically developed for the enrichment of CTC clusters fail to achieve a high enough processing throughput to be practical in clinical settings or risk damaging large clusters owing to their structural design producing high shear forces. Here, we outline a methodology developed for rapid and effective enrichment of CTC clusters from cancer patients, independent of the cluster size and cell surface markers. Minimally invasive access to tumor cells in hematogenous circulation will be an integral part of cancer screening and personalized medicine.


Subject(s)
Neoplastic Cells, Circulating , Humans , Neoplastic Cells, Circulating/pathology , Cell Separation/methods , Blood Coagulation Tests
3.
Small ; 19(27): e2208035, 2023 07.
Article in English | MEDLINE | ID: mdl-37010045

ABSTRACT

Severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) continues to threaten lives by evolving into new variants with greater transmissibility. Although lateral flow assays (LFAs) are widely used to self-test for coronavirus disease 2019 (COVID-19), these tests suffer from low sensitivity leading to a high rate of false negative results. In this work, a multiplexed lateral flow assay is reported for the detection of SARS-CoV-2 and influenza A and B viruses in human saliva with a built-in chemical amplification of the colorimetric signal for enhanced sensitivity. To automate the amplification process, the paper-based device is integrated with an imprinted flow controller, which coordinates the routing of different reagents and ensures their sequential and timely delivery to run an optimal amplification reaction. Using the assay, SARS-CoV-2 and influenza A and B viruses can be detected with ≈25x higher sensitivity than commercial LFAs, and the device can detect SARS-CoV-2-positive patient saliva samples missed by commercial LFAs. The technology provides an effective and practical solution to enhance the performance of conventional LFAs and will enable sensitive self-testing to prevent virus transmission and future outbreaks of new variants.


Subject(s)
COVID-19 , Herpesvirus 1, Cercopithecine , Influenza, Human , Humans , SARS-CoV-2 , COVID-19/diagnosis , Influenza, Human/diagnosis , Paint , Sensitivity and Specificity
4.
Lab Chip ; 23(2): 251-260, 2023 01 17.
Article in English | MEDLINE | ID: mdl-36598080

ABSTRACT

Enzyme-linked immunosorbent assay (ELISA) is widely employed for detecting target molecules in bioassays including the serological assays that measure specific antibody titers. However, ELISA tests are inherently limited to centralized laboratories staffed with trained personnel as the assay workflow requires multiple steps to be performed in a specific sequence. Here, we report a dipstick ELISA test that automates this otherwise laborious process and reports the titer of a target molecule in a digital manner without the need for an external instrument or operator. Our assay measures titer by gradually immuno-depleting the target analyte from a flowing sample effectively diluting the residual target - a process conventionally achieved through serially diluting the whole sample in numerous, time-consuming pipetting steps performed manually. Furthermore, the execution of the depletion ELISA process is automated by a built-in flow controller which sequentially delivers different reagents with preset delays. We apply the technology to develop assays measuring (1) severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody titers (IgM/IgG antibodies to nucleocapsid and spike protein) and (2) troponin I, a cardiac biomarker.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Antibodies, Viral , Immunoglobulin G , Enzyme-Linked Immunosorbent Assay , Immunoglobulin M , Sensitivity and Specificity
5.
Biosens Bioelectron ; 222: 114916, 2023 Feb 15.
Article in English | MEDLINE | ID: mdl-36462431

ABSTRACT

Characterization of cell populations and identification of distinct subtypes based on surface markers are needed in a variety of applications from basic research and clinical assays to cell manufacturing. Conventional immunophenotyping techniques such as flow cytometry or fluorescence microscopy require immunolabeling of cells, expensive and complex instrumentation, skilled operators, and are therefore incompatible with field deployment and automated cell manufacturing systems. In this work, we introduce an autonomous microchip that can electronically quantify the immunophenotypical composition of a cell suspension. Our microchip identifies different cell subtypes by capturing each in different microfluidic chambers functionalized against the markers of the target populations. All on-chip activity is electronically monitored by an integrated sensor network, which informs an algorithm determining subpopulation fractions from chip-wide immunocapture statistics in real time. Moreover, optimal operational conditions within the chip are enforced through a closed-loop feedback control on the sensor data and the cell flow speed, and hence, the antibody-antigen interaction time is maintained within its optimal range for selective immunocapture. We apply our microchip to analyze a mixture of unlabeled CD4+ and CD8+ T cell sub-populations and then validated the results against flow cytometry measurements. The demonstrated capability to quantitatively analyze immune cells with no labels has the potential to enable not only autonomous biochip-based immunoassays for remote testing but also cell manufacturing bioreactors with built-in, adaptive quality control.


Subject(s)
Biosensing Techniques , Microfluidics/methods , Oligonucleotide Array Sequence Analysis , Flow Cytometry/methods , Immunoassay
6.
Nat Commun ; 13(1): 3385, 2022 06 13.
Article in English | MEDLINE | ID: mdl-35697674

ABSTRACT

Extremely rare circulating tumor cell (CTC) clusters are both increasingly appreciated as highly metastatic precursors and virtually unexplored. Technologies are primarily designed to detect single CTCs and often fail to account for the fragility of clusters or to leverage cluster-specific markers for higher sensitivity. Meanwhile, the few technologies targeting CTC clusters lack scalability. Here, we introduce the Cluster-Wells, which combines the speed and practicality of membrane filtration with the sensitive and deterministic screening afforded by microfluidic chips. The >100,000 microwells in the Cluster-Wells physically arrest CTC clusters in unprocessed whole blood, gently isolating virtually all clusters at a throughput of >25 mL/h, and allow viable clusters to be retrieved from the device. Using the Cluster-Wells, we isolated CTC clusters ranging from 2 to 100+ cells from prostate and ovarian cancer patients and analyzed a subset using RNA sequencing. Routine isolation of CTC clusters will democratize research on their utility in managing cancer.


Subject(s)
Neoplastic Cells, Circulating , Humans , Male , Neoplastic Cells, Circulating/pathology , Sequence Analysis, RNA
7.
Lab Chip ; 22(12): 2331-2342, 2022 06 14.
Article in English | MEDLINE | ID: mdl-35593257

ABSTRACT

Leukocytes are the frontline defense mechanism of the immune system. Their composition dynamically changes as a response to a foreign body, infection, inflammation, or other malignant behavior occurring within the body. Monitoring the composition of leukocytes, namely leukocyte differential, is a crucial assay periodically performed to diagnose an infection or to assess a person's vulnerability for a health anomaly. Currently, leukocyte differential analysis is performed using hematology analyzers or flow cytometers, both of which are bulky instruments that require trained and certified personnel for operation. In this work, we demonstrate a new technique to obtain leukocyte differentials in a highly portable and integrated microfluidic chip by magnetically analyzing the CD33 expression of leukocytes. When benchmarked against conventional laboratory instruments, our technology demonstrated <5% difference on average for all subtypes. Our results show that hematology testing could be performed beyond the centralized laboratories at a low cost and ultimately provide point-of-care and at-home testing opportunities.


Subject(s)
Hematologic Tests , Leukocytes , Electronics , Flow Cytometry , Humans , Leukocyte Count
8.
Biosens Bioelectron ; 203: 114014, 2022 May 01.
Article in English | MEDLINE | ID: mdl-35092880

ABSTRACT

Surface expression of cell populations are often sought as diagnostic and prognostic biomarkers in hematology-oncology and infectious diseases, making flow cytometry an invaluable technique for both clinical and basic research applications. On the other hand, the reliance of flow cytometry on manual input parameters and user protocols for operation introduces variation between analyses while potentially leading to errors in measurements. In this work, we introduce an integrated flow cytometry microchip that automatically adapts to the sample it interrogates. Our device measures the antigen expression in a sample by automatically analyzing the response of immunomagnetically labeled cells to an external magnetic field through integrated electrical sensors and by continuously modulating the time the cells are subjected to the field for optimal sensitivity and dynamic range. Furthermore, the lack of optical illumination and fluorescence detectors enables automated analysis to be carried on a fully integrated platform that is particularly well suited for translation into point-of-care testing and mobile screening. We applied our automated cytometry chip on both pure and mixed cell populations and validated its operation by benchmarking against a conventional flow cytometer. By transforming the utility-proven flow cytometry, a technique that has long been dependent on an operator in centralized laboratories, into a standardized disposable test for bedside or home testing, the automated flow cytometry microchip introduced here has the potential to enable self-screening for telemedicine and wellness.


Subject(s)
Biosensing Techniques , Flow Cytometry/methods , Point-of-Care Testing
9.
Lab Chip ; 22(2): 296-312, 2022 01 18.
Article in English | MEDLINE | ID: mdl-34897353

ABSTRACT

Membrane antigens are phenotypic signatures of cells used for distinguishing various subpopulations and, therefore, are of great interest for diagnosis of diseases and monitoring of patients in hematology and oncology. Existing methods to measure antigen expression of a target subpopulation in blood samples require labor-intensive lysis of contaminating cells and subsequent analysis with complex and bulky instruments in specialized laboratories. To address this long-standing limitation in clinical cytometry, we introduce a microchip-based technique that can directly measure surface expression of target cells in hematological samples. Our microchip isolates an immunomagnetically-labeled target cell population from the contaminating background in whole blood and then utilizes the differential responses of target cells to on-chip magnetic manipulation to estimate their antigen expression. Moreover, manipulating cells with chip-sized permanent magnets and performing quantitative measurements via an on-chip electrical sensor network allows the assay to be performed in a portable platform with no reliance on laboratory infrastructure. Using our technique, we could successfully measure expressions of the CD45 antigen that is commonly expressed by white blood cells, as well as CD34 that is expressed by scarce hematopoietic progenitor cells, which constitutes only ∼0.0001% of all blood cells, directly from whole blood. With our technology, flow cytometry can potentially become a rapid bedside or at-home testing method that is available around the clock in environments where this invaluable assay with proven clinical utility is currently either outsourced or not even accessible.


Subject(s)
Antigens , Hematopoietic Stem Cells , Antigens, CD34/analysis , Electronics , Flow Cytometry/methods , Hematopoietic Stem Cells/chemistry , Humans
10.
Sci Rep ; 11(1): 20583, 2021 10 18.
Article in English | MEDLINE | ID: mdl-34663896

ABSTRACT

Reliable and routine isolation of circulating tumor cells (CTCs) from peripheral blood would allow effective monitoring of the disease and guide the development of personalized treatments. Negative enrichment of CTCs by depleting normal blood cells ensures against a biased selection of a subpopulation and allows the assay to be applied on different tumor types. Here, we report an additively manufactured microfluidic device that can negatively enrich viable CTCs from clinically-relevant volumes of unmanipulated whole blood samples. Our device depletes nucleated blood cells based on their surface antigens and the smaller anucleated cells based on their size. Enriched CTCs are made available off the device in suspension making our technique compatible with standard immunocytochemical, molecular and functional assays. Our device could achieve a ~ 2.34-log depletion by capturing > 99.5% of white blood cells from 10 mL of whole blood while recovering > 90% of spiked tumor cells. Furthermore, we demonstrated the capability of the device to isolate CTCs from blood samples collected from patients (n = 15) with prostate and pancreatic cancers in a pilot study. A universal CTC assay that can differentiate tumor cells from normal blood cells with the specificity of clinically established membrane antigens yet require no label has the potential to enable routine blood-based tumor biopsies at the point-of-care.


Subject(s)
Neoplastic Cells, Circulating/metabolism , Adult , Aged , Cell Count , Cell Line, Tumor , Cell Separation/methods , Female , Humans , Lab-On-A-Chip Devices , Leukocytes/cytology , Male , Microfluidic Analytical Techniques/instrumentation , Middle Aged , Neoplastic Cells, Circulating/pathology , Pilot Projects , Printing, Three-Dimensional
11.
Sci Adv ; 7(40): eabf9833, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34597143

ABSTRACT

Lateral flow assays (LFAs) use capillary flow of liquids for simple detection of analytes. While useful for spontaneously wicking samples, the capillary flow inherently limits performing complex reactions that require timely application of multiple solutions. Here, we introduce a technique to control capillary flow on paper by imprinting roadblocks on the flow path with water-insoluble ink and using the gradual formation of a void between a wetted paper and a sheath polymer tape to create timers. Timers are drawn at strategic nodes to hold the capillary flow for a desired period and thereby enable multiple liquids to be introduced into multistep chemical reactions following a programmed sequence. Using our technique, we developed (i) an LFA with built-in signal amplification to detect human chorionic gonadotropin with an order of magnitude higher sensitivity than the conventional assay and (ii) a device to extract DNA from bodily fluids without relying on laboratory instruments.

12.
ACS Sens ; 6(9): 3204-3213, 2021 09 24.
Article in English | MEDLINE | ID: mdl-34523904

ABSTRACT

Severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) is still spreading around the globe causing immense public health and socioeconomic problems. As the infection can progress with mild symptoms that can be misinterpreted as the flu, self-testing methods that can positively identify SARS-CoV-2 are needed to effectively track and prevent the transmission of the virus. In this work, we report a point-of-care toolkit for multiplex molecular diagnosis of SARS-CoV-2 and influenza A and B viruses in saliva samples. Our assay is physically programmed to run a sequence of chemical reactions on a paper substrate and internally generate heat to drive these reactions for an autonomous extraction, purification, and amplification of the viral RNA. Using our assay, we could reliably detect SARS-CoV-2 and influenza viruses at concentrations as low as 50 copies/µL visually from a colorimetric analysis. The capability to autonomously perform a traditionally labor-intensive genetic assay on a disposable platform will enable frequent, on-demand self-testing, a critical need to track and contain this and future outbreaks.


Subject(s)
COVID-19 , Herpesvirus 1, Cercopithecine , Influenza, Human , Humans , Influenza, Human/diagnosis , Point-of-Care Systems , SARS-CoV-2
13.
Lab Chip ; 21(10): 1916-1928, 2021 05 18.
Article in English | MEDLINE | ID: mdl-34008660

ABSTRACT

Microfluidic technologies have long enabled the manipulation of flow-driven cells en masse under a variety of force fields with the goal of characterizing them or discriminating the pathogenic ones. On the other hand, a microfluidic platform is typically designed to function under optimized conditions, which rarely account for specimen heterogeneity and internal/external perturbations. In this work, we demonstrate a proof-of-principle adaptive microfluidic system that consists of an integrated network of distributed electrical sensors for on-chip tracking of cells and closed-loop feedback control that modulates chip parameters based on the sensor data. In our system, cell flow speed is measured at multiple locations throughout the device, the data is interpreted in real-time via deep learning-based algorithms, and a proportional-integral feedback controller updates a programmable pressure pump to maintain a desired cell flow speed. We validate the adaptive microfluidic system with both static and dynamic targets and also observe a fast convergence of the system under continuous external perturbations. With an ability to sustain optimal processing conditions in unsupervised settings, adaptive microfluidic systems would be less prone to artifacts and could eventually serve as reliable standardized biomedical tests at the point of care.


Subject(s)
Deep Learning , Microfluidics , Algorithms , Artifacts , Feedback
14.
Biosens Bioelectron ; 174: 112818, 2021 Feb 15.
Article in English | MEDLINE | ID: mdl-33250334

ABSTRACT

Spatial manipulation of suspended cells based on their properties is an essential part of numerous microfluidic assays. To further read and analyze the manipulation result, a microscopy system is typically required, which, however, increases the cost and reduces the portability of the entire system. As an alternative, a network of integrated Coulter sensors, distributed over a microfluidic chip, provide rapid and reliable detection of spatially-manipulated cells. Code-multiplexing of distributed Coulter sensors enables simplification of such integration by offloading the hardware complexity into advanced signal processing techniques that are needed to interpret the coded sensor outputs. In this work, we combine code-multiplexed Coulter sensor networks with an error-correction technique, a strategy typically used in telecommunication systems for controlling errors in data over unreliable communication channels. Specifically, we include redundancy in the physical sensor design to alleviate the ambiguity in the signal-decoding process, so that interfering sensor signals due to coincidently-detected cells can be resolved reliably. The presented sensor technology not only tracks the spatiotemporal state of cells under test but also measures their sizes and flow speeds. To demonstrate the sensor concept experimentally, we fabricated a microfluidic device with 10 distributed Coulter sensors designed to produce distinct signal waveforms and performed experiments with suspended human cancer cells to characterize the performance of the sensor platform.


Subject(s)
Biosensing Techniques , Microfluidics , Biological Assay , Humans , Lab-On-A-Chip Devices
15.
Small ; 15(51): e1904732, 2019 12.
Article in English | MEDLINE | ID: mdl-31631578

ABSTRACT

Immunophenotyping is widely used to characterize cell populations in basic research and to diagnose diseases from surface biomarkers in the clinic. This process usually requires complex instruments such as flow cytometers or fluorescence microscopes, which are typically housed in centralized laboratories. Microfluidics are combined with an integrated electrical sensor network to create an antibody microarray for label-free cell immunophenotyping against multiple antigens. The device works by fractionating the sample via capturing target subpopulations in an array of microfluidic chambers functionalized against different antigens and by electrically quantifying the cell capture statistics through a network of code-multiplexed electrical sensors. Through a combinatorial arrangement of antibody sequences along different microfluidic paths, the device can measure the prevalence of different cell subpopulations in a sample from computational analysis of the electrical output signal. The device performance is characterized by analyzing heterogeneous samples of mixed tumor cell populations and then the technique is applied to determine leukocyte subpopulations in blood samples and the results are validated against complete blood cell count and flow cytometry results. Label-free immunophenotyping of cell populations against multiple targets on a disposable electronic chip presents opportunities in global health and telemedicine applications for cell-based diagnostics and health monitoring.


Subject(s)
Immunophenotyping/methods , Animals , Electronics , Flow Cytometry/methods , Humans , Microfluidics/methods
16.
Lab Chip ; 19(19): 3292-3304, 2019 10 07.
Article in English | MEDLINE | ID: mdl-31482906

ABSTRACT

Beyond their conventional use of counting and sizing particles, Coulter sensors can be used to spatially track suspended particles, with multiple sensors distributed over a microfluidic chip. Code-multiplexing of Coulter sensors allows such integration to be implemented with simple hardware but requires advanced signal processing to extract multi-dimensional information from the output waveform. In this work, we couple deep learning-based signal analysis with microfluidic code-multiplexed Coulter sensor networks. Specifically, we train convolutional neural networks to analyze Coulter waveforms not only to recognize certain sensor waveform patterns but also to resolve interferences among them. Our technology predicts the size, speed, and location of each detected particle. We show that the algorithm yields a >90% pattern recognition accuracy for distinguishing non-correlated waveform patterns at a processing speed that can potentially enable real-time microfluidic assays. Furthermore, once trained, the algorithm can readily be applied for processing electrical data from other microfluidic devices integrated with the same Coulter sensor network.

17.
Lab Chip ; 19(20): 3427-3437, 2019 10 09.
Article in English | MEDLINE | ID: mdl-31553343

ABSTRACT

Isolation and analysis of circulating tumor cells (CTCs) from blood samples present exciting opportunities for basic cancer research and personalized treatment of the disease. While microchip-based negative CTC enrichment offers both sensitive microfluidic cell screening and unbiased selection, conventional microchips are inherently limited by their capacity to deplete a large number of normal blood cells. In this paper, we use 3D printing to create a monolithic device that combines immunoaffinity-based microfluidic cell capture and a commercial membrane filter for negative enrichment of CTCs directly from whole blood. In our device, stacked layers of chemically-functionalized microfluidic channels capture millions of white blood cells (WBCs) in parallel without getting saturated and the leuko-depleted blood is post-filtered with a 3 µm-pore size membrane filter to eliminate anucleated blood cells. This hybrid negative enrichment approach facilitated direct extraction of viable CTCs off the chip on a membrane filter for downstream analysis. Immunofluorescence imaging of enriched cells showed ∼90% tumor cell recovery rate from simulated samples spiked with prostate, breast or ovarian cancer cells. We also demonstrated the feasibility of our approach for processing clinical samples by isolating prostate cancer CTCs directly from a 10 mL whole blood sample.


Subject(s)
Cell Separation/methods , Neoplastic Cells, Circulating/chemistry , Printing, Three-Dimensional , Antibodies, Immobilized/chemistry , Antibodies, Immobilized/immunology , Cell Separation/instrumentation , Humans , Jurkat Cells , Lab-On-A-Chip Devices , Leukocytes/cytology , Leukocytes/immunology , Neoplastic Cells, Circulating/immunology
18.
Lab Chip ; 19(14): 2444-2455, 2019 07 21.
Article in English | MEDLINE | ID: mdl-31199420

ABSTRACT

Membrane antigens control cell function by regulating biochemical interactions and hence are routinely used as diagnostic and prognostic targets in biomedicine. Fluorescent labeling and subsequent optical interrogation of cell membrane antigens, while highly effective, limit expression profiling to centralized facilities that can afford and operate complex instrumentation. Here, we introduce a cytometry technique that computes surface expression of immunomagnetically labeled cells by electrically tracking their trajectory under a magnetic field gradient on a microfluidic chip with a throughput of >500 cells per min. In addition to enabling the creation of a frugal cytometry platform, this immunomagnetic cell manipulation-based measurement approach allows direct expression profiling of target subpopulations from non-purified samples. We applied our technology to measure epithelial cell adhesion molecule expression on human breast cancer cells. Once calibrated, surface expression and size measurements match remarkably well with fluorescence-based measurements from a commercial flow cytometer. Quantitative measurements of biochemical and biophysical cell characteristics with a disposable cytometer have the potential to impact point of care testing of clinical samples particularly in resource limited settings.


Subject(s)
Gene Expression Regulation , Immunomagnetic Separation/instrumentation , Lab-On-A-Chip Devices , Membrane Glycoproteins/metabolism , Calibration , Equipment Design , Humans , MCF-7 Cells
19.
Biosens Bioelectron ; 120: 30-39, 2018 Nov 30.
Article in English | MEDLINE | ID: mdl-30144643

ABSTRACT

Microfluidic devices can discriminate particles based on their properties and map them into different locations on the device. For distributed detection of these particles, we have recently introduced a multiplexed sensing technique called Microfluidic CODES, which combines code division multiple access with Coulter sensing. Our technique relies on micromachined sensor geometries to produce distinct waveforms that can uniquely be linked to specific locations on the microfluidic device. In this work, we investigated the scaling of the code-multiplexed Coulter sensor network through theoretical and experimental analysis. As a model system, we designed and fabricated a microfluidic device integrated with a network of 10 code-multiplexed sensors, each of which was characterized and verified to produce a 31-bit orthogonal digital code. To predict the performance of the sensor network, we developed a mathematical model based on communications and coding theory, and calculated the error rate for our sensor network as a function of the network size and sample properties. We theoretically and experimentally demonstrated the effect of electrical impedance on the signal-to-noise ratio and developed an optimized device. We also introduced a computational approach that can process the sensor network data with minimal input from the user and demonstrated system-level operation by processing suspensions of cultured human cancer cells. Taken together, our results demonstrated the feasibility of deploying large-scale code-multiplexed electrode networks for distributed Coulter detection to realize integrated lab-on-a-chip devices.


Subject(s)
Electrodes , Microfluidics/instrumentation , Cell Line, Tumor , Humans , Lab-On-A-Chip Devices , Models, Theoretical
20.
Sci Rep ; 7(1): 17375, 2017 12 12.
Article in English | MEDLINE | ID: mdl-29234006

ABSTRACT

High throughput size based separation and sorting of bioparticles and cells is critical to a variety of biomedical processing steps for medical diagnostics and pharmaceutical purification. Improving microfluidic size-based particle/cell sorting is a challenge to better address the need for generating more homogeneous subpopulations for study and use. We propose a novel advance to microfluidic sorting devices that uses three-dimensional focusing of the sample to optimally position particles to amplify the size-dependent differences in trajectories caused by differential secondary flows. The result is an increase in the purity of small particles by 35- fold and large particles by 8-fold in comparison to unfocused flow. Our simulated and experimental data reveal for the first time that positioning particles in three-dimensional space can be used to better leverage the differential lateral movement of particles with different sizes as they flow in microchannel with transverse secondary flows. The focusing approach may also be useful to improve positioning of particles with inertial channels with multiple equilibrium positions. This technique performs continuous-flow, high throughput size based sorting of millions of particles and cells in a minute without any pre and post-processing. We have also demonstrated improved enrichment and recovery of white blood cells from human blood.


Subject(s)
Cell Separation/methods , Hydrodynamics , Microfluidics/methods , Particle Size , Humans , Leukocytes
SELECTION OF CITATIONS
SEARCH DETAIL
...