1.
Front Cardiovasc Med ; 9: 899594, 2022.
Article in English | MEDLINE | ID: mdl-35845048

ABSTRACT

Background: Platelet function testing to monitor antiplatelet therapy is important for reducing thromboembolic complications, yet variability across testing methods remains challenging. Here we evaluated the agreement of four different testing platforms used to monitor antiplatelet effects of aspirin (ASA) or P2Y12 inhibitors (P2Y12-I). Methods: Blood and urine specimens from 20 patients receiving dual antiplatelet therapy were analyzed by light transmission aggregometry (LTA), whole blood aggregometry (WBA), VerifyNow PRUTest and AspirinWorks. Result interpretation based on pre-defined cutoff values was used to calculate raw agreement indices, and Pearson's correlation coefficient determined using individual units of measure. Results: Agreement between LTA and WBA for P2Y12-I-response was 60% (r = 0.65, high-dose ADP; r = 0.75, low-dose ADP). VerifyNow agreed with LTA in 75% (r = 0.86, high-dose ADP; r = 0.75, low-dose ADP) and WBA in 55% (r = 0.57) of cases. Agreement between LTA and WBA for ASA-response was 45% (r = 0.09, high-dose collagen WBA; r = 0.19, low-dose collagen WBA). AspirinWorks agreed with LTA in 60% (r = 0.32) and WBA in 35% (r = 0.02, high-dose collagen WBA; r = 0.08, low-dose collagen WBA) of cases. Conclusions: Overall agreement varied from 35 to 75%. LTA and VerifyNow demonstrated the highest agreement for P2Y12-I-response, followed by moderate agreement between LTA and WBA. LTA and AspirinWorks showed moderate agreement for aspirin response, while WBA showed the weakest agreement with both LTA and AspirinWorks. The results from this study support the continued use of LTA for monitoring dual antiplatelet therapy, with VerifyNow as an appropriate alternative for P2Y12-I-response. Integration of results obtained from these varied testing platforms with patient outcomes remains paramount for future studies.

2.
Clin Lab Med ; 41(4): 579-598, 2021 12.
Article in English | MEDLINE | ID: mdl-34689966

ABSTRACT

Blood transfusion begins with safe donor selection and testing. In the United States, the blood supply and transfusion are highly regulated. Blood transfusion safety is multifaceted, whereby each of the elements of the blood safety value chain, spanning donor recruitment and qualification, to collection, blood processing, testing, transfusion practice, and posttransfusion surveillance, must be optimized to minimize risk. Pathogen inactivation is a promising approach to decrease bacterial contamination of platelets, inactivate parasites and viruses, and decrease risks associated with emerging and unidentified pathogens. This article offers an overview of blood donor infectious and noninfectious testing in the United States.


Subject(s)
Blood Safety , Communicable Diseases , Blood Donors , Blood Transfusion , Communicable Diseases/diagnosis , Humans , United States
4.
J Thromb Thrombolysis ; 52(3): 766-771, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33829396

ABSTRACT

Patients critically ill with COVID-19 are at risk for thrombotic events despite prophylactic anticoagulation. Impaired fibrinolysis has been proposed as an underlying mechanism. Our objective was to determine if fibrinolysis stimulated by tissue plasminogen activator (tPA) differed between COVID patients and controls. Plasma from 14 COVID patients on prophylactic heparin therapy was obtained and compared with heparinized plasma from 14 different healthy donors to act as controls. Kaolin activated thromboelastography with heparinase was utilized to obtain baseline measurements and then repeated with the addition of 4 nM tPA. Baseline fibrinogen levels were higher in COVID plasma as measured by maximum clot amplitude (43.6 ± 6.9 mm vs. 23.2 ± 5.5 mm, p < 0.0001) and Clauss assay (595 ± 135 mg/dL vs. 278 ± 44 mg/dL, p < 0.0001). With the addition of tPA, fibrinolysis at 30 min after MA (LY30%) was lower (37.9 ± 16.5% vs. 58.9 ± 18.3%, p = 0.0035) and time to 50% lysis was longer (48.8 ± 16.3 vs. 30.5 ± 15.4 min, p = 0.0053) in the COVID-19 samples. Clotting times and rate of fibrin polymerization ('R' or 'α' parameters) were largely the same in both groups. Clot from COVID patients contains a higher fibrin content compared to standard controls and shows resistance to fibrinolysis induced by tPA. These findings suggest the clinical efficacy of thrombolytics may be reduced in COVID-19 patients.


Subject(s)
COVID-19/blood , Fibrinolysis/drug effects , Fibrinolytic Agents/pharmacology , Thrombelastography , Tissue Plasminogen Activator/pharmacology , COVID-19/diagnosis , Case-Control Studies , Critical Illness , Humans , Kinetics
5.
Indian J Hematol Blood Transfus ; 32(Suppl 1): 214-8, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27408395

ABSTRACT

An eighteen-year-old female with Graves thyrotoxicosis presented with methimazole-induced agranulocytosis and total myeloid aplasia. The bone marrow at presentation showed complete absence of myeloid precursors and striking plasmacytosis. 16 days later, myeloid precursors were still absent morphologically; however bone marrow flow cytometry and cell culture detected an improvement in myelogenesis, which was soon followed by clinical recovery of agranulocytosis. Neutrophil recovery was delayed until day 22 after cessation of methimazole despite G-CSF use, consistent with a direct toxic effect on committed myeloid cells. Our findings suggest that cell culture and flow cytometric evaluation of bone marrow myeloid progenitors can be used as a guide to anticipate neutrophil recovery.