Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
AME Case Rep ; 5: 32, 2021.
Article in English | MEDLINE | ID: mdl-34805751

ABSTRACT

Apical cannulation of a left ventricle for temporary support is still challenging, especially in case of prolonged support due to donor organ shortage. Traditional cannulation techniques with the cannula being directly inserted into the left ventricle cavity are technically easy, but prone to hemorrhage during circulatory support, unsafe for a prolonged support (over than 30 days) and limits the possibility to ambulate patient due to risk for cannula dislocation and related life-threatening bleeding. We describe a case of temporary left ventricular assist device placement in a 59-year-old male patient being on veno-arterial extracorporeal membrane oxygenation support secondary to acute myocardial infarction. We present a very simple technique to secure insertion of an apical left ventricular cannula using patch of soft Teflon felt. Handmade created apical soft Teflon cuff is than fixed using twelve 4/0 prolene sutures supported with pledgets. This gives better fixation to apical myocardium (especially in case of fragile tissue after acute infarction) and secure intracavitary length of inflow cannula in a controlled mode, thus better than purse-string sutures only. Using anti-adhesive membrane, further dissection during heart transplant procedure was uneventful. This technique allowed safe circulatory support and patient ambulation in the ward during 85 days until heart transplantation.

2.
Adv Ther ; 38(4): 1832-1842, 2021 04.
Article in English | MEDLINE | ID: mdl-33665760

ABSTRACT

INTRODUCTION: Rapid deployment aortic valve replacement has been recently introduced in clinical practice. Different studies have reported a significant reduction in surgical times with excellent hemodynamic profiles and short-term results. However, an increase in permanent pacemaker requirements compared with conventional aortic valve replacement has been described. Nevertheless, risk factors for postoperative pacemaker implantation are not well known. The aim of this study is to report our early outcomes with rapid deployment aortic valve replacement within the RADAR Registry, especially focusing on risk factors for postoperative pacemaker implantation. METHODS: Between April 2012 and January 2016, 164 patients undergoing isolated or combined aortic valve replacement with Edwards INTUITY Elite (Edwards Lifesciences, Irvine, CA, USA) were included in the RADAR Registry. Pre-, intra- and postoperative clinical data results and complications were recorded, especially focusing on risk factors for the development of postoperative complete or high-grade AV block requiring pacemaker implantation. Patients were followed up for up to 1 year with evaluation of clinical and echocardiographic outcomes. RESULTS: A total of 164 consecutive patients were included in this study, where 128 patients (78.05%) had an isolated aortic valve replacement (group 1) and 36 (21.95%) a concomitant procedure (group 2). The surgical approach was ministernotomy in 61 patients (37.20%) and median sternotomy in 100 patients (60.98%). Complications with valve implantation were observed in three patients. Postoperative complete or high-degree AV block requiring a permanent pacemaker implantation developed in ten patients (6.9%). Seven patients died in-hospital (4.27%). No significant differences between groups were found in terms of stroke, postoperative infection, mortality, atrial fibrillation and postoperative atrioventricular block. Seven patients presented acute renal impairment (5.51%) in group 1 versus seven patients (20%) in group 2 (p = 0.007). In multivariate analysis, low weight and preoperative arrhythmia (atrial fibrillation, bifascicular block, left bundle branch block) emerged as risk factors for postoperative AV block requiring a pacer. In median follow-up of 1 year, seven (4.27%) patients died, and no cases of structural valve deterioration or endocarditis were observed. Significant patient-prosthesis mismatch was found in seven (4.27%) patients. CONCLUSION: Initial experience with rapid deployment aortic valve replacement in the RADAR Registry demonstrates low rates of implantation complications and good perioperative and 1-year clinical and echocardiographic outcomes. Incidence of postoperative AV block requiring a pacer correlated with low weight and preoperative arrythmias (atrial fibrillation, bifascicular block and left bundle branch block). Avoidance of oversizing and careful consideration of implantation of this technology in patients with pre-existing arrythmias could minimize the risk for postoperative pacemaker implantation.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Postoperative Complications/epidemiology , Registries , Retrospective Studies , Risk Factors , Treatment Outcome
3.
J Vasc Surg ; 66(5): 1417-1426, 2017 11.
Article in English | MEDLINE | ID: mdl-28823865

ABSTRACT

OBJECTIVE: The objective of this study was to determine risk factors for nosocomial infections (NIs) and predictors of mortality in patients with prosthetic vascular grafts (PVGs). METHODS: This was a prospective cohort study of all consecutive patients who underwent PVG of the abdominal aorta with or without iliac-femoral involvement and peripheral PVG from April 2008 to August 2009 at a university hospital. Patients younger than 15 years and those with severe immunodeficiency were excluded. The follow-up period was until 3 years after surgery or until death. RESULTS: There were 261 patients included; 230 (88.12%) were male, and the mean age was 67.57 (standard deviation, 10.82) years. The reason for operation was aortic aneurysm in 49 (18.77%) patients or lower limb arteriopathy in 212 (81.23%) patients. NIs occurred in 71 (27.20%) patients. Of these, 42 were surgical site infections (SSIs), of which 61.9% occurred in the lower extremities (14 superficial, 10 deep, and 2 PVG infections) and 38.1% in the abdomen (7 superficial, 7 deep, and 2 PVG infections); 15 were respiratory tract infections; and 15 were urinary tract infections. Active lower extremity skin and soft tissue infection (SSTI) at the time of surgery was a significant predictor of NI for both types of PVG (abdominal aortic PVG: adjusted odds ratio [OR], 12.6; 95% confidence interval [CI], 1.15-138.19; peripheral PVG: adjusted OR, 2.43; 95% CI, 1.08-5.47). Other independent predictors of NI were mechanical ventilation (adjusted OR, 55.96; 95% CI, 3.9-802.39) for abdominal aortic PVG and low hemoglobin levels on admission (adjusted OR, 0.84; 95% CI, 0.71-0.99) and emergent surgery (adjusted OR, 4.39; 95% CI, 1.51-12.74) for peripheral PVG. The in-hospital mortality rate was 1.92%. The probability of surviving the first month was 0.96, and significant predictors of mortality were active lower extremity SSTI (adjusted risk ratio [RR], 12.07; 95% CI, 1.04-154.75), high postsurgical glucose levels (adjusted RR, 1.02; 95% CI, 1.00-1.04), and noninfectious surgical complications (adjusted RR, 19.38; 95% CI, 2.25-167.29). The long-term mortality rate was 11.88%. The probability of surviving at 12, 24, and 36 months was 0.94, 0.92, and 0.87, respectively. Variables significantly associated with long-term death were older age (adjusted RR, 1.08; 95% CI, 1.01-1.15), high values of creatinine on discharge (adjusted RR, 1.91; 95% CI, 1.08-3.38), and an SSI with the highest adjusted RR (6.35; 95% CI, 1.87-21.53). CONCLUSIONS: SSI was the primary NI. The risk of NI depended primarily on the presence of a lower extremity SSTI at the time of surgery, whereas mortality was determined by age, surgical complications during the operation, and SSI. These findings suggest that in those cases in which surgery is reasonably delayed, surgery should be deferred until the lower extremity SSTIs are resolved.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis/adverse effects , Cross Infection/microbiology , Peripheral Vascular Diseases/surgery , Prosthesis-Related Infections/microbiology , Respiratory Tract Infections/microbiology , Surgical Wound Infection/microbiology , Urinary Tract Infections/microbiology , Adult , Age Factors , Aged , Aged, 80 and over , Biomarkers/blood , Blood Vessel Prosthesis Implantation/mortality , Chi-Square Distribution , Creatinine/blood , Cross Infection/diagnosis , Cross Infection/mortality , Cross Infection/therapy , Female , Hospital Mortality , Hospitals, University , Humans , Kaplan-Meier Estimate , Logistic Models , Male , Middle Aged , Multivariate Analysis , Odds Ratio , Proportional Hazards Models , Prospective Studies , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/mortality , Prosthesis-Related Infections/therapy , Respiratory Tract Infections/diagnosis , Respiratory Tract Infections/mortality , Respiratory Tract Infections/therapy , Risk Factors , Spain , Surgical Wound Infection/diagnosis , Surgical Wound Infection/mortality , Surgical Wound Infection/therapy , Time Factors , Treatment Outcome , Urinary Tract Infections/diagnosis , Urinary Tract Infections/mortality , Urinary Tract Infections/therapy
4.
Ann Vasc Surg ; 45: 127-137, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28647631

ABSTRACT

BACKGROUND: Anastomotic or "stitch hole" bleeding is common during vascular surgery with synthetic material such as Dacron or polytetrafluoroethylene. Hemostatic adjuncts such as fibrin sealant (FS) may reduce blood loss and operating time in such circumstances. We evaluated the safety and the hemostatic effectiveness of a ready-to-use human plasma-derived FS in vascular surgery. METHODS: Patients with mild/moderate suture line bleeding during elective, open, vascular surgery using synthetic grafts or patches were studied. In an initial Exploratory Study, all patients were treated with FS Grifols, and in a subsequent Primary Study were randomized in a 2:1 ratio to FS Grifols or manual compression (MC). The primary efficacy end point was time to hemostasis (TTH), assessed at defined intervals from the start of treatment application, during a 10-min observational period. Safety end points (in Exploratory + Primary Studies) included adverse events (AEs), vital signs, physical assessments, common clinical laboratory tests (coagulation, complete blood count, serum clinical chemistry parameters, microscopic urinalysis), viral markers, and immunogenicity. RESULTS: In the Primary Study, the proportion of patients who achieved hemostasis at the 3-min time point was higher in the FS Grifols group (46.4%, n = 51/110) than in the MC group (26.3%, n = 15/57) (P < 0.05). The benefit was maintained at successive time intervals: 69 FS Grifols patients (62.7%) and 18 MC patients (31.6%) at 4 min; 82 FS Grifols patients (74.5%) and 28 MC patients (49.1%) at 5 min. The differences between the groups persisted for TTH ≤ 7 min and TTH ≤ 10 min. Treatment failure was reported for 13 FS Grifols patients (11.8%) and 16 MC patients (28.1%). TTH was shorter after FS Grifols application than after MC application. Differences were statistically significant in favor of FS Grifols for each TTH category and for the overall comparison (P < 0.001) as well as for each TTH category (cumulative) and for treatment failure (P = 0.016). Overall, AE experience and types of AEs reported were those expected in this patient population and were similar between the 2 treatment groups. The most frequently reported AEs were procedural pain (59.9% and 69.2% of patients in the FS Grifols [n = 72 + 111] and MC [n = 57] groups, respectively) and nausea (23.5% and 19.2% of patients, respectively). CONCLUSIONS: FS Grifols was efficacious and safe as an adjunct to anastomotic hemostasis in patients undergoing arterial surgery using prosthetic material with mild to moderate bleeding.


Subject(s)
Blood Loss, Surgical/prevention & control , Fibrin Tissue Adhesive/therapeutic use , Hemostasis/drug effects , Hemostatic Techniques , Hemostatics/therapeutic use , Vascular Surgical Procedures/adverse effects , Aged , Aged, 80 and over , Canada , Female , Fibrin Tissue Adhesive/adverse effects , Hemostatic Techniques/adverse effects , Hemostatics/adverse effects , Humans , Male , Middle Aged , Prospective Studies , Single-Blind Method , Spain , Time Factors , Treatment Outcome , United Kingdom
5.
Echocardiography ; 34(9): 1399-1400, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28401594

ABSTRACT

Papillary fibroelastoma is an uncommon primary cardiac tumor, predominantly associated with left-sided valvular endocardium. Affectation of tricuspid valve leaflets is rare, and management in asymptomatic patients remains controversial. We present a 30-year-old female referred for evaluation prior to bariatric surgery. A routine echocardiogram revealed a mobile cardiac mass attached to the tricuspid valve. A patent foramen ovale was also present. Tumor was surgically removed. Histology confirmed the definite diagnosis of a papillary fibroelastoma. In our case, the presence of a patent foramen ovale associated with the right-sided fibroelastoma was decisive in the decision for surgery.


Subject(s)
Echocardiography, Transesophageal/methods , Fibroma/diagnosis , Foramen Ovale, Patent/complications , Heart Neoplasms/diagnosis , Incidental Findings , Tricuspid Valve/diagnostic imaging , Adult , Cardiac Surgical Procedures/methods , Diagnosis, Differential , Female , Fibroma/complications , Fibroma/surgery , Foramen Ovale, Patent/diagnosis , Heart Neoplasms/complications , Heart Neoplasms/surgery , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...