Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 89
Filter
1.
Invest Radiol ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38742928

ABSTRACT

OBJECTIVE: Photon-counting detector computed tomography (PCD-CT) enables spectral data acquisition of CT angiographies allowing for reconstruction of virtual monoenergetic images (VMIs) in routine practice. Specifically, it has potential to reduce the blooming artifacts associated with densely calcified plaques. However, calcium blooming and iodine attenuation are inversely affected by energy level (keV) of the VMIs, creating a challenge for contrast media (CM) injection protocol optimization. A pragmatic and simple rule for calcium-dependent CM injection protocols is investigated and proposed for VMI-based coronary CT angiography with PCD-CT. MATERIALS AND METHODS: A physiological circulation phantom with coronary vessels including calcified lesions (maximum CT value >700 HU) with a 50% diameter stenosis was injected into at iodine delivery rates (IDRs) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g I/s. Images were acquired using a first-generation dual-source PCD-CT and reconstructed at various VMI levels (between 45 and 190 keV). Iodine attenuation in the coronaries was measured at each IDR for each keV, and blooming artifacts from the calcified lesions were assessed including stenosis grading error (as % overestimation vs true lumen). The IDR to achieve 300 HU at each VMI level was then calculated and compared with stenosis grading accuracy to establish a general rule for CM injection protocols. RESULTS: Plaque blooming artifacts and intraluminal iodine attenuation decreased with increasing keV. Fixed windowing (representing absolute worst case) resulted in stenosis overestimation from 77% ± 4% at 45 keV to 5% ± 2% at 190 keV, whereas optimized windowing resulted in overestimation from 29% ± 3% at 45 keV to 4% ± 1% at 190 keV. The required IDR to achieve 300 HU showed a strong linear correlation to VMI energy (R2 = 0.98). Comparison of this linear plot versus stenosis grading error and blooming artifact demonstrated that multipliers of 1, 2, and 3 times the reference IDR for theoretical clinical regimes of no, moderate, and severe calcification density, respectively, can be proposed as a general rule. CONCLUSIONS: This study provides a proof-of-concept in an anthropomorphic phantom for a simple pragmatic adaptation of CM injection protocols in coronary CT angiography with PCD-CT. The 1-2-3 rule demonstrates the potential for reducing the effects of calcium blooming artifacts on overall image quality.

2.
Article in English | MEDLINE | ID: mdl-38700819

ABSTRACT

Almost 35 years after its introduction, coronary artery calcium score (CACS) not only survived technological advances but became one of the cornerstones of contemporary cardiovascular imaging. Its simplicity and quantitative nature established it as one of the most robust approaches for atherosclerotic cardiovascular disease risk stratification in primary prevention and a powerful tool to guide therapeutic choices. Groundbreaking advances in computational models and computer power translated into a surge of artificial intelligence (AI)-based approaches directly or indirectly linked to CACS analysis. This review aims to provide essential knowledge on the AI-based techniques currently applied to CACS, setting the stage for a holistic analysis of the use of these techniques in coronary artery calcium imaging. While the focus of the review will be detailing the evidence, strengths, and limitations of end-to-end CACS algorithms in electrocardiography-gated and non-gated scans, the current role of deep-learning image reconstructions, segmentation techniques, and combined applications such as simultaneous coronary artery calcium and pulmonary nodule segmentation, will also be discussed.

3.
J Clin Med ; 13(8)2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38673617

ABSTRACT

Background: MRI diagnostics are important for adenomyosis, especially in cases with inconclusive ultrasound. This study assessed the potential of MRI-based radiomics as a novel tool for differentiating between uteri with and without adenomyosis. Methods: This retrospective proof-of-principle single-center study included nine patients with and six patients without adenomyosis. All patients had preoperative T2w MR images and histological findings served as the reference standard. The uterus of each patient was segmented in 3D using dedicated software, and 884 radiomics features were extracted. After dimension reduction and feature selection, the diagnostic yield of individual and combined features implemented in the machine learning models were assessed by means of receiver operating characteristics analyses. Results: Eleven relevant radiomics features were identified. The diagnostic performance of individual features in differentiating adenomyosis from the control group was high, with areas under the curve (AUCs) ranging from 0.78 to 0.98. The performance of ML models incorporating several features was excellent, with AUC scores of 1 and an area under the precision-recall curve of 0.4. Conclusions: The set of radiomics features derived from routine T2w MRI enabled accurate differentiation of uteri with adenomyosis. Radiomics could enhance diagnosis and furthermore serve as an imaging biomarker to aid in personalizing therapies and monitoring treatment responses.

4.
EJNMMI Res ; 14(1): 36, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38578516

ABSTRACT

BACKGROUND: Liver uptake in [68Ga]Ga-PSMA-11 PET is used as an internal reference in addition to clinical parameters to select patients for [177Lu]Lu-PSMA-617 radioligand therapy (RLT). Due to increased demand, [68Ga]Ga-PSMA-11 was replaced by [18F]F-PSMA-1007, a more lipophilic tracer with different biodistribution and splenic uptake was suggested as a new internal reference. We compared the intra-patient tracer distribution between [68Ga]Ga-PSMA-11 and [18F]F-PSMA-1007. METHODS: Fifty patients who underwent PET examinations in two centers with both [18F]F-PSMA-1007 and [68Ga]Ga-PSMA-11 within one year were included. Mean standardized uptake values (SUVmean) were obtained for liver, spleen, salivary glands, blood pool, and bone. Primary tumor, local recurrence, lymph node, bone or visceral metastasis were also assessed for intra- and inter-individual comparison. RESULTS: Liver SUVmean was significantly higher with [18F]F-PSMA-1007 (11.7 ± 3.9) compared to [68Ga]Ga-PSMA-11 (5.4 ± 1.7, p < .05) as well as splenic SUVmean (11.2 ± 3.5 vs.8.1 ± 3.5, p < .05). The blood pool was comparable between the two scans. Malignant lesions did not show higher SUVmean on [18F]F-PSMA-1007. Intra-individual comparison of liver uptake between the two scans showed a linear association for liver uptake with SUVmean [68Ga]Ga-PSMA-11 = 0.33 x SUVmean [18F]F-PSMA-1007 + 1.52 (r = .78, p < .001). CONCLUSION: Comparing biodistribution of [68Ga]Ga and [18F]F tracers, liver uptake on [68Ga]Ga-PSMA-11 PET is the most robust internal reference value. Liver uptake of [18F]F-PSMA-1007 was significantly higher, but so was the splenic uptake. The strong intra-individual association of hepatic accumulation between the two scans may allow using of a conversion factor for [18F]F-PSMA-1007 as a basis for RLT selection.

5.
Radiol Cardiothorac Imaging ; 6(2): e230217, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38451189

ABSTRACT

Purpose To compare image quality, diagnostic performance, and conspicuity between single-energy and multi-energy images for endoleak detection at CT angiography (CTA) after endovascular aortic repair (EVAR). Materials and Methods In this single-center prospective randomized controlled trial, individuals undergoing CTA after EVAR between August 2020 and May 2022 were allocated to imaging using either low-kilovolt single-energy images (SEI; 80 kV, group A) or low-kiloelectron volt virtual monoenergetic images (VMI) at 40 and 50 keV from multi-energy CT (80/Sn150 kV, group B). Scan protocols were dose matched (volume CT dose index: mean, 4.5 mGy ± 1.8 [SD] vs 4.7 mGy ± 1.3, P = .41). Contrast-to-noise ratio (CNR) was measured. Two expert radiologists established the reference standard for the presence of endoleaks. Detection and conspicuity of endoleaks and subjective image quality were assessed by two different blinded radiologists. Interreader agreement was calculated. Nonparametric statistical tests were used. Results A total of 125 participants (mean age, 76 years ± 8; 103 men) were allocated to groups A (n = 64) and B (n = 61). CNR was significantly lower for 40-keV VMI (mean, 19.1; P = .048) and 50-keV VMI (mean, 16.8; P < .001) as compared with SEI (mean, 22.2). In total, 45 endoleaks were present (A: 23 vs B: 22). Sensitivity for endoleak detection was higher for SEI (82.6%, 19 of 23; P = .88) and 50-keV VMI (81.8%, 18 of 22; P = .90) as compared with 40-keV VMI (77.3%, 17 of 22). Specificity was comparable among groups (SEI: 92.7%, 38 of 41; both VMI energies: 92.3%, 35 of 38; P = .99), with an interreader agreement of 1. Conspicuity of endoleaks was comparable between SEI (median, 2.99) and VMI (both energies: median, 2.87; P = .04). Overall subjective image quality was rated significantly higher for SEI (median, 4 [IQR, 4-4) as compared with 40 and 50 keV (both energies: median, 4 [IQR, 3-4]; P < .001). Conclusion SEI demonstrated higher image quality and comparable diagnostic accuracy as compared with 50-keV VMI for endoleak detection at CTA after EVAR. Keywords: Aneurysms, CT, CT Angiography, Vascular, Aorta, Technology Assessment, Multidetector CT, Abdominal Aortic Aneurysms, Endoleaks, Perigraft Leak Supplemental material is available for this article. © RSNA, 2024.


Subject(s)
Computed Tomography Angiography , Endoleak , Aged , Humans , Male , Aorta , Endoleak/diagnostic imaging , Physical Phenomena , Prospective Studies , Female
6.
Invest Radiol ; 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38526041

ABSTRACT

OBJECTIVES: Calcified plaques induce blooming artifacts in coronary computed tomography angiography (CCTA) potentially leading to inaccurate stenosis evaluation. Tungsten represents a high atomic number, experimental contrast agent with different physical properties than iodine. We explored the potential of a tungsten-based contrast agent for photon-counting detector (PCD) CCTA in heavily calcified coronary vessels. MATERIALS AND METHODS: A cardiovascular phantom exhibiting coronaries with calcified plaques was imaged on a first-generation dual-source PCD-CT. The coronaries with 3 different calcified plaques were filled with iodine and tungsten contrast media solutions equating to iodine and tungsten delivery rates (IDR and TDR) of 0.3, 0.5, 0.7, 1.0, 1.5, 2.0, 2.5, and 3.0 g/s, respectively. Electrocardiogram-triggered sequential acquisitions were performed in the spectral mode (QuantumPlus). Virtual monoenergetic images (VMIs) were reconstructed from 40 to 190 keV in 1 keV increments. Blooming artifacts and percentage error stenoses from calcified plaques were quantified, and attenuation characteristics of both contrast media were recorded. RESULTS: Blooming artifacts from calcified plaques were most pronounced at 40 keV (78%) and least pronounced at 190 keV (58%). Similarly, percentage error stenoses were highest at 40 keV (48%) and lowest at 190 keV (2%), respectively. Attenuation of iodine decreased monotonically in VMIs from low to high keV, with the strongest decrease from 40 keV to 100 keV (IDR of 2.5 g/s: 1279 HU at 40 keV, 187 HU at 100 kV, and 35 HU at 190 keV). The attenuation of tungsten, on the other hand, increased monotonically as a function of VMI energy, with the strongest increase between 40 and 100 keV (TDR of 2.5 g/s: 202 HU at 40 keV, 661 HU at 100 kV, and 717 HU at 190 keV). For each keV level, the relationship between attenuation and IDR/TDR could be described by linear regressions (R2 ≥ 0.88, P < 0.001). Specifically, attenuation increased linearly when increasing the delivery rate irrespective of keV level or contrast medium. Iodine exhibited the highest relative increase in attenuation values at lower keV levels when increasing the IDR. Conversely, for tungsten, the greatest relative increase in attenuation values occurred at higher keV levels when increasing the TDR. When high keV imaging is desirable to reduce blooming artifacts from calcified plaques, IDR has to be increased at higher keV levels to maintain diagnostic vessel attenuation (ie, 300 HU), whereas for tungsten, TDR can be kept constant or can be even reduced at high keV energy levels. CONCLUSIONS: Tungsten's attenuation characteristics in relation to VMI energy levels are reversed to those of iodine, with tungsten exhibiting high attenuation values at high keV levels and vice versa. Thus, tungsten shows promise for high keV imaging CCTA with PCD-CT as-in distinction to iodine-both high vessel attenuation and low blooming artifacts from calcified plaques can be achieved.

7.
Article in English | MEDLINE | ID: mdl-38389028

ABSTRACT

To intra-individually investigate the variation of coronary artery calcium (CAC), aortic valve calcium (AVC), and mitral annular calcium (MAC) scores and the presence of blur artifacts as a function of temporal resolution in patients undergoing non-contrast cardiac CT on a dual-source photon counting detector (PCD) CT. This retrospective, IRB-approved study included 70 patients (30 women, 40 men, mean age 78 ± 9 years) who underwent ECG-gated cardiac non-contrast CT with PCD-CT (gantry rotation time 0.25 s) prior to transcatheter aortic valve replacement. Each scan was reconstructed at a temporal resolution of 66 ms using the dual-source information and at 125 ms using the single-source information. Average heart rate and heart rate variability were calculated from the recorded ECG. CAC, AVC, and MAC were quantified according to the Agatston method on images with both temporal resolutions. Two readers assessed blur artifacts using a 4-point visual grading scale. The influence of average heart rate and heart rate variability on calcium quantification and blur artifacts of the respective structures were analyzed by linear regression analysis. Mean heart rate and heart rate variability during data acquisition were 76 ± 17 beats per minute (bpm) and 4 ± 6 bpm, respectively. CAC scores were smaller on 66 ms (median, 511; interquartile range, 220-978) than on 125 ms reconstructions (538; 203-1050, p < 0.001). Median AVC scores [2809 (2009-3952) versus 3177 (2158-4273)] and median MAC scores [226 (0-1284) versus 251 (0-1574)] were also significantly smaller on 66ms than on 125ms reconstructions (p < 0.001). Reclassification of CAC and AVC risk categories occurred in 4% and 11% of cases, respectively, whereby the risk category was always overestimated on 125ms reconstructions. Image blur artifacts were significantly less on 66ms as opposed to 125 ms reconstructions (p < 0.001). Intra-individual analyses indicate that temporal resolution significantly impacts on calcium scoring with cardiac CT, with CAC, MAC, and AVC being overestimated at lower temporal resolution because of increased motion artifacts eventually leading to an overestimation of patient risk.

9.
Eur Radiol ; 34(3): 1716-1723, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37644149

ABSTRACT

OBJECTIVES: To introduce an automated computational algorithm that estimates the global noise level across the whole imaging volume of PET datasets. METHODS: [18F]FDG PET images of 38 patients were reconstructed with simulated decreasing acquisition times (15-120 s) resulting in increasing noise levels, and with block sequential regularized expectation maximization with beta values of 450 and 600 (Q.Clear 450 and 600). One reader performed manual volume-of-interest (VOI) based noise measurements in liver and lung parenchyma and two readers graded subjective image quality as sufficient or insufficient. An automated computational noise measurement algorithm was developed and deployed on the whole imaging volume of each reconstruction, delivering a single value representing the global image noise (Global Noise Index, GNI). Manual noise measurement values and subjective image quality gradings were compared with the GNI. RESULTS: Irrespective of the absolute noise values, there was no significant difference between the GNI and manual liver measurements in terms of the distribution of noise values (p = 0.84 for Q.Clear 450, and p = 0.51 for Q.Clear 600). The GNI showed a fair to moderately strong correlation with manual noise measurements in liver parenchyma (r = 0.6 in Q.Clear 450, r = 0.54 in Q.Clear 600, all p < 0.001), and a fair correlation with manual noise measurements in lung parenchyma (r = 0.52 in Q.Clear 450, r = 0.33 in Q.Clear 600, all p < 0.001). Classification performance of the GNI for subjective image quality was AUC 0.898 for Q.Clear 450 and 0.919 for Q.Clear 600. CONCLUSION: An algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. CLINICAL RELEVANCE STATEMENT: An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking of clinical PET imaging within and across institutions. KEY POINTS: • Noise is an important quantitative marker that strongly impacts image quality of PET images. • An automated computational noise measurement algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. • An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking as well as protocol harmonization.


Subject(s)
Image Processing, Computer-Assisted , Positron-Emission Tomography , Humans , Image Processing, Computer-Assisted/methods , Positron-Emission Tomography/methods , Fluorodeoxyglucose F18 , Liver/diagnostic imaging , Algorithms , Positron Emission Tomography Computed Tomography , Phantoms, Imaging
10.
Front Psychiatry ; 14: 1258272, 2023.
Article in English | MEDLINE | ID: mdl-38076700

ABSTRACT

Background: Switzerland ranks among the top three healthcare systems in the world with regards to healthcare access, suggesting a high degree of health equity. However, Switzerland has few preventive strategies against smoking abuse. The aim of this study is to clarify whether educational level and citizenship status have an influence on the prevalence of smoking in Switzerland and whether there is health inequity related to a lack of preventive strategies. Methods: We based our analysis on publicly available health data published in the Swiss government's Swiss health survey (1992-2017). We compared the prevalence of smoking across the years and correlated these data with levels of educational attainment, citizenship status and age. Results: A continuous significant decline in smokers is observed in the highest education group (TERT). Over time, prevalence was reduced from 29% in 1992 to 23% in 2017 (p < 0.001). The intermediate-level educational group (SEK 2) showed smaller but also significant decline on a 0.05 sigificance level over the same period, from 31% to 29% (p = 0.003). The lowest educational group showed a nonsignificant decline from 28% to 27% (p = 0.6). The population who holds Swiss citizenship showed a decrease in smoking from 28% to 26% within the time frame (p < 0.001). People without Swiss citizenship had a much higher prevalence of smokers, at 38% in 1992 and declining to 32% in 2017 (p < 0.001). All cohorts from age 15 to age 64 have a far higher prevalence of smokers than cohorts at an older age, with the highest prevalence in the 25-34 age group. Conclusion: In Switzerland, individuals with lower levels of education and non-Swiss populations are more susceptible to health risk of smoking. This is despite the existence of a high-quality healthcare system that has nevertheless failed to negated health inequities.

11.
Cancers (Basel) ; 15(23)2023 Nov 24.
Article in English | MEDLINE | ID: mdl-38067274

ABSTRACT

Transthoracic esophagectomy results in a radical change in foregut anatomy with multiple consequences for digestive physiology. The aim of this study was to identify factors associated with poor functional outcomes by assessing multiple dimensions of digestive performance and health-related quality of life (HRQL). Patients with cancer-free survival after Ivor Lewis esophagectomy were included. Four functional syndromes (dysphagia, gastroesophageal reflux disease (GERD), delayed gastric conduit emptying (DGCE), and dumping syndrome (DS)) and HRQL were assessed using specifically designed questionnaires. Patient outcomes were compared with healthy controls. Independent factors associated with poor digestive performance were identified through multivariable analysis. Sixty-five postoperative patients and 50 healthy volunteers participated in this study. Compared with controls, patients had worse outcomes for dysphagia, GERD, DS, and HRQL, but not for DGCE. A multivariate analysis showed a significant correlation of reduced digestive performance with ASA score, squamous cell carcinoma, open or hybrid surgical approach, and (neo)adjuvant therapy. In contrast, no individual patient factor was found to be associated with dumping syndrome. Digestive function and HRQL are substantially impaired after Ivor Lewis esophagectomy for cancer. Comorbid patients undergoing multimodal treatment and open access surgery for squamous cell carcinoma have the highest risk of poor functional outcome.

12.
Sci Rep ; 13(1): 18847, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37914764

ABSTRACT

The purpose of this retrospective study was to investigate response of sinonasal mucosal melanoma (SMM) patients to treatment with immune checkpoint inhibitors (ICI), using hybrid PET imaging. Fifteen SMM patients underwent hybrid PET imaging before and three months after initiation of ICI. The disease-specific survival (DSS) was calculated. Quantitative PET parameters of the primary tumor and their association with DSS and therapy response were investigated. Nine of the fifteen (60%) patients responded to ICI therapy. Patients with therapy response depicted on hybrid PET imaging had better DSS than those without (p = 0.0058). Quantitative PET parameters of the initial PET harbored no association with DSS or therapy response. However, these findings lack of sufficient statistical power and must be interpreted with caution. The first restaging PET-imaging after ICI initiation can help stratify patients with regard to DSS.


Subject(s)
Melanoma , Paranasal Sinus Neoplasms , Humans , Immune Checkpoint Inhibitors/pharmacology , Immune Checkpoint Inhibitors/therapeutic use , Positron Emission Tomography Computed Tomography/methods , Retrospective Studies , Melanoma/diagnostic imaging , Melanoma/drug therapy , Melanoma/pathology , Positron-Emission Tomography , Paranasal Sinus Neoplasms/pathology , Fluorodeoxyglucose F18
13.
PLoS One ; 18(11): e0291007, 2023.
Article in English | MEDLINE | ID: mdl-37939048

ABSTRACT

INTRODUCTION: A trend towards less male radiologists specializing in breast ultrasound was observed. A common notion in the field of breast radiology is, that female patients feel more comfortable being treated by female radiologists. The aim of the study was to understand and report the needs of women undergoing breast ultrasound with regards to the sex of the radiologist performing the investigation. METHODS: Informed consent was obtained from all patients prior to inclusion in a prospective bi-center quality study. At center 1 (72 patients), the women were examined exclusively by female radiologists, at center 2 (100 patients) only by male radiologists. After the examination the patients were asked about their experiences and their wishes for the future. RESULTS: Overall, women made no distinction between female and male radiologists; 25% of them wanted a female radiologist and 1.2% wanted a male radiologist. The majority (74%) stated that it made no difference whether a female or male radiologist performed the examination. The majority of women in group 2, who were investigated exclusively by male radiologists, stated that they had no preferences with regard to the sex of the radiologist (93%); 5% of the women wished to be investigated solely by a female radiologist and 2% exclusively by a male radiologist. DISCUSSION: The majority of women undergoing breast ultrasound are unconcerned about the radiologist's sex. It would appear that women examined by male radiologists are less selective about the sex of the examining radiologist. TRIAL REGISTRATION: Written informed consent was obtained from all patients. All patient data were anonymized. The physicians had no access to any further personal data. National regulations did not require dedicated ethics approval with anonymized lists or retrospective questionnaires.


Subject(s)
Breast Neoplasms , Physicians , Humans , Female , Male , Prospective Studies , Retrospective Studies , Radiologists , Ultrasonography, Mammary
14.
Eur Radiol ; 2023 Oct 19.
Article in English | MEDLINE | ID: mdl-37855853

ABSTRACT

OBJECTIVES: To assess the evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between years 2000 and 2021. METHODS: Pediatric patients (≤ 16 years) referred for 18F-FDG PET/CT or PET/MR imaging of the body during 2000 and 2021 were retrospectively included. The amount of administered radiotracer activity in megabecquerel (MBq) was recorded, and signal-to-noise ratio (SNR) was measured in the right liver lobe with a 4 cm3 volume of interest as an indicator for objective image quality. Descriptive statistics were computed. RESULTS: Two hundred forty-three children and adolescents underwent a total of 466 examinations. The median injected 18F-FDG activity in MBq decreased significantly from 296 MBq in 2000-2005 to 100 MBq in 2016-2021 (p < 0.001), equaling approximately one-third of the initial amount. The median SNR ratio was stable during all years with 11.7 (interquartile range [IQR] 10.7-12.9, p = 0.133). CONCLUSIONS: Children have benefited from a massive reduction in the administered 18F-FDG dose over the past 20 years without compromising objective image quality. CLINICAL RELEVANCE STATEMENT: Radiotracer dose was reduced considerably over the past two decades of pediatric F-18-fluorodeoxyglucose PET/CT and PET/MR imaging highlighting the success of technical innovations in pediatric PET imaging. KEY POINTS: • The evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between 2000 and 2021 was assessed. • The injected tracer activity decreased by 66% during the study period from 296 megabecquerel (MBq) to 100 MBq (p < 0.001). • The continuous implementation of technical innovations in pediatric hybrid 18F-FDG PET has led to a steady decrease in the amount of applied radiotracer, which is particularly beneficial for children who are more sensitive to radiation.

15.
Sci Rep ; 13(1): 18357, 2023 10 26.
Article in English | MEDLINE | ID: mdl-37884535

ABSTRACT

This study aimed to evaluate the diagnostic accuracy of Node Reporting and Data System (Node-RADS) in discriminating between normal, reactive, and metastatic axillary LNs in patients with melanoma who underwent SARS-CoV-2 vaccination. Patients with proven melanoma who underwent a 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (2-[18F]-FDG PET/CT) between February and April 2021 were included in this retrospective study. Primary melanoma site, vaccination status, injection site, and 2-[18F]-FDG PET/CT were used to classify axillary LNs into normal, inflammatory, and metastatic (combined classification). An adapted Node-RADS classification (A-Node-RADS) was generated based on LN anatomical characteristics on low-dose CT images and compared to the combined classification. 108 patients were included in the study (54 vaccinated). HALNs were detected in 42 patients (32.8%), of whom 97.6% were vaccinated. 172 LNs were classified as normal, 30 as inflammatory, and 14 as metastatic using the combined classification. 152, 22, 29, 12, and 1 LNs were classified A-Node-RADS 1, 2, 3, 4, and 5, respectively. Hence, 174, 29, and 13 LNs were deemed benign, equivocal, and metastatic. The concordance between the classifications was very good (Cohen's k: 0.91, CI 0.86-0.95; p-value < 0.0001). A-Node-RADS can assist the classification of axillary LNs in melanoma patients who underwent 2-[18F]-FDG PET/CT and SARS-CoV-2 vaccination.


Subject(s)
COVID-19 , Melanoma , Humans , Positron Emission Tomography Computed Tomography/methods , COVID-19 Vaccines , SARS-CoV-2 , Fluorodeoxyglucose F18 , Retrospective Studies , Neoplasm Staging , Lymphatic Metastasis/pathology , COVID-19/diagnostic imaging , COVID-19/pathology , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Melanoma/diagnostic imaging , Melanoma/pathology , Vaccination , Radiopharmaceuticals
16.
Br J Radiol ; 96(1152): 20220482, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37751216

ABSTRACT

OBJECTIVES: To evaluate the evolution of CT radiation dose in pediatric patients undergoing hybrid 2-[18F]fluoro-2-deoxy-D-glucose (2-[18F]FDG) PET/CT between 2007 and 2021. METHODS AND MATERIALS: Data from all pediatric patients aged 0-18 years who underwent hybrid 2-[18F]FDG PET/CT of the body between January 2007 and May 2021 were reviewed. Demographic and imaging parameters were collected. A board-certified radiologist reviewed all CT scans and measured image noise in the brain, liver, and adductor muscles. RESULTS: 294 scans from 167 children (72 females (43%); median age: 14 (IQR 10-15) years; BMI: median 17.5 (IQR 15-20.4) kg/m2) were included. CT dose index-volume (CTDIvol) and dose length product (DLP) both decreased significantly from 2007 to 2021 (both p < 0.001, Spearman's rho coefficients -0.46 and -0.35, respectively). Specifically, from 2007 to 2009 to 2019-2021 CTDIvol and DLP decreased from 2.94 (2.14-2.99) mGy and 309 (230-371) mGy*cm, respectively, to 0.855 (0.568-1.11) mGy and 108 (65.6-207) mGy*cm, respectively. From 2007 to 2021, image noise in the brain and liver remained constant (p = 0.26 and p = 0.06), while it decreased in the adductor muscles (p = 0.007). Peak tube voltage selection (in kilovolt, kV) of CT scans shifted from high kV imaging (140 or 120kVp) to low kV imaging (100 or 80kVp) (p < 0.001) from 2007 to 2021. CONCLUSION: CT radiation dose in pediatric patients undergoing hybrid 2-[18F]FDG PET/CT has decreased in recent years equaling approximately one-third of the initial amount. ADVANCES IN KNOWLEDGE: Over the past 15 years, CT radiation dose decreased considerably in pediatric patients undergoing hybrid imaging, while objective image quality may not have been compromised.


Subject(s)
Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Female , Humans , Child , Adolescent , Radiation Dosage , Tomography, X-Ray Computed/methods , Brain
17.
Radiol Cardiothorac Imaging ; 5(3): e220307, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37404795

ABSTRACT

Purpose: To assess the accuracy of aortic valve calcium (AVC), mitral annular calcium (MAC), and coronary artery calcium (CAC) quantification and risk stratification using virtual noncontrast (VNC) images from late enhancement photon-counting detector CT as compared with true noncontrast images. Materials and Methods: This retrospective, institutional review board-approved study evaluated patients undergoing photon-counting detector CT between January and September 2022. VNC images were reconstructed from late enhancement cardiac scans at 60, 70, 80, and 90 keV using quantum iterative reconstruction (QIR) strengths of 2-4. AVC, MAC, and CAC were quantified on VNC images and compared with quantification of AVC, MAC, and CAC on true noncontrast images using Bland-Altman analyses, regression models, intraclass correlation coefficients (ICC), and Wilcoxon tests. Agreement between severe aortic stenosis likelihood categories and CAC risk categories determined from VNC and true noncontrast images was assessed by weighted κ analysis. Results: Ninety patients were included (mean age, 80 years ± 8 [SD]; 49 male patients). Scores were similar on true noncontrast images and VNC images at 80 keV for AVC and MAC, regardless of QIR strengths, and VNC images at 70 keV with QIR 4 for CAC (all P > .05). The best results were achieved using VNC images at 80 keV with QIR 4 for AVC (mean difference, 3; ICC = 0.992; r = 0.98) and MAC (mean difference, 6; ICC = 0.998; r = 0.99), and VNC images at 70 keV with QIR 4 for CAC (mean difference, 28; ICC = 0.996; r = 0.99). Agreement between calcification categories was excellent on VNC images at 80 keV for AVC (κ = 0.974) and on VNC images at 70 keV for CAC (κ = 0.967). Conclusion: VNC images from cardiac photon-counting detector CT enables patient risk stratification and accurate quantification of AVC, MAC, and CAC.Keywords: Coronary Arteries, Aortic Valve, Mitral Valve, Aortic Stenosis, Calcifications, Photon-counting Detector CT Supplemental material is available for this article © RSNA, 2023.

18.
Eur J Radiol ; 166: 110981, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37478655

ABSTRACT

PURPOSE: To assess image quality and detectability of interstitial lung changes using multiple radiation doses from the same chest CT scan of patients with suspected interstitial lung disease (ILD). METHOD: Retrospective study of consecutive adult patients with suspected ILD receiving unenhanced chest CT as single-energy dual-source acquisition at 100 kVp (Dual-split mode). 67% and 33% of the overall tube current time product were assigned to tube A and B, respectively. 100%-dose was 2.34 ± 0.97 mGy. Five different radiation doses (100%, 67%, 45%, 39%, 33%) were reconstructed from this single acquisition using linear-blending technique. Two blinded radiologists assessed reticulations, ground-glass opacities (GGO) and honeycombing as well as subjective image noise. Percentage agreement (PA) as compared to 100%-dose were calculated. Non-parametric statistical tests were used. RESULTS: A total of 228 patients were included (61.2 ± 14.6 years,146 female). PA was highest for honeycombing (>96%) and independent of dose reduction (P > 0.8). PA for reticulations and GGO decreased when reducing the radiation dose from 100% to 67% for both readers (reticulations: 83.3% and 93.9%; GGO: 87.7% and 79.8% for reader 1 and 2, respectively). Additional dose reduction did not significantly change PA for both readers (all P > 0.05). Subjective image noise increased with decreasing radiation dose (Spearman Rho of ρ = 0.34 and ρ = 0.53 for reader 1 and 2, respectively, P < 0.001). CONCLUSIONS: Radiation dose reduction had a stronger impact on subtle interstitial lung changes. Detectability decreased with initial dose reduction indicating that a minimum dose is needed to maintain diagnostic accuracy in chest CT for suspected ILD.


Subject(s)
Lung Diseases, Interstitial , Tomography, X-Ray Computed , Adult , Humans , Female , Retrospective Studies , Radiation Dosage , Tomography, X-Ray Computed/methods , Lung Diseases, Interstitial/diagnostic imaging , Lung/diagnostic imaging
19.
Invest Radiol ; 58(11): 816-821, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37358359

ABSTRACT

OBJECTIVES: The aim of this study was to compare image quality and endoleak detection after endovascular abdominal aortic aneurysm repair between a triphasic computed tomography (CT) with true noncontrast (TNC) and a biphasic CT with virtual noniodine (VNI) images on photon-counting detector CT (PCD-CT). MATERIALS AND METHODS: Adult patients after endovascular abdominal aortic aneurysm repair who received a triphasic examination (TNC, arterial, venous phase) on a PCD-CT between August 2021 and July 2022 were retrospectively included. Endoleak detection was evaluated by 2 blinded radiologists on 2 different readout sets (triphasic CT with TNC-arterial-venous vs biphasic CT with VNI-arterial-venous). Virtual noniodine images were reconstructed from the venous phase. The radiologic report with additional confirmation by an expert reader served as reference standard for endoleak presence. Sensitivity, specificity, and interreader agreement (Krippendorf α) were calculated. Image noise was assessed subjectively in patients using a 5-point scale and objectively calculating the noise power spectrum in a phantom. RESULTS: One hundred ten patients (7 women; age, 76 ± 8 years) with 41 endoleaks were included. Endoleak detection was comparable between both readout sets with a sensitivity and specificity of 0.95/0.84 (TNC) versus 0.95/0.86 (VNI) for reader 1 and 0.88/0.98 (TNC) versus 0.88/0.94 (VNI) for reader 2. Interreader agreement for endoleak detection was substantial (TNC: 0.716, VNI: 0.756). Subjective image noise was comparable between TNC and VNI (4; IQR [4, 5] vs 4; IQR [4, 5], P = 0.44). In the phantom, noise power spectrum peak spatial frequency was similar between TNC and VNI (both f peak = 0.16 mm -1 ). Objective image noise was higher in TNC (12.7 HU) as compared with VNI (11.5 HU). CONCLUSIONS: Endoleak detection and image quality were comparable using VNI images in biphasic CT as compared with TNC images in triphasic CT offering the possibility to reduce scan phases and radiation exposure.


Subject(s)
Aortic Aneurysm, Abdominal , Endoleak , Adult , Humans , Female , Aged , Aged, 80 and over , Endoleak/diagnostic imaging , Computed Tomography Angiography/methods , Endovascular Aneurysm Repair , Retrospective Studies , Tomography, X-Ray Computed/methods , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery
20.
Acad Radiol ; 30 Suppl 1: S305-S313, 2023 09.
Article in English | MEDLINE | ID: mdl-37150736

ABSTRACT

RATIONALE AND OBJECTIVES: To investigate the impact of virtual monoenergetic images (VMI) from photon-counting detector CT (PCD-CT) on the enhancement and classification of renal cysts. MATERIALS AND METHODS: Adults with renal cysts (≥7 mm) who received a triphasic examination on a clinical PCD-CT (120 kVp; IQ level 68) between July 2021 and March 2022 were retrospectively identified. Only non-enhancing cysts (enhancement<10 HU between unenhanced and venous phase at 70 keV) were included. VMI from 40 to 190 keV with increments of 10 keV were reconstructed from the venous phase. Enhancement was measured to classify each lesion as non-enhancing (<10 HU), equivocally enhancing (10-19 HU), and definitely enhancing (≥20 HU). Classification changes as a function of VMI were assessed. Pearson correlation coefficient, the Kruskal-Wallis and the Chi-square test were used. RESULTS: A total of 86 patients (mean age, 74 ± 9 years; 74 male) with 160 non-enhancing renal cysts (17.6 ± 10 mm) were included. CT attenuation of the cysts increased from higher to lower VMI levels with a mean attenuation of 4 ± 11 HU at 190 keV to 36 ± 17 HU at 40 keV. Mean attenuation of the renal parenchyma was 43 ± 4 HU at 190 keV and 414 ± 71 HU at 40 keV. No cyst exhibited enhancement from 70 keV to 190 keV. At 40, 50, and 60 keV, 35% (56/160), 29% (47/160) and 9% (15/160) of cysts showed equivocal and 46% (74/160), 10% (16/160), and 0% (0/160) definite enhancement, respectively. There was no significant influence of size (P=.13), cyst location (P=.9) and BMI (P=.19) on enhancement classification. CONCLUSION: VMI has a relevant impact on enhancement and classification of renal cysts with misclassification in a large number of cases at energy levels below 70 keV.


Subject(s)
Cysts , Kidney Diseases, Cystic , Kidney Neoplasms , Radiography, Dual-Energy Scanned Projection , Adult , Humans , Male , Aged , Aged, 80 and over , Retrospective Studies , Tomography, X-Ray Computed/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Kidney Diseases, Cystic/diagnostic imaging , Cysts/diagnostic imaging , Signal-To-Noise Ratio , Radiography, Dual-Energy Scanned Projection/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...