Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 671
Filter
1.
Rev Sci Instrum ; 94(3): 033511, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-37012804

ABSTRACT

High-power, short-pulse laser-driven fast electrons can rapidly heat and ionize a high-density target before it hydrodynamically expands. The transport of such electrons within a solid target has been studied using two-dimensional (2D) imaging of electron-induced Kα radiation. However, it is currently limited to no or picosecond scale temporal resolutions. Here, we demonstrate femtosecond time-resolved 2D imaging of fast electron transport in a solid copper foil using the SACLA x-ray free electron laser (XFEL). An unfocused collimated x-ray beam produced transmission images with sub-micron and ∼10 fs resolutions. The XFEL beam, tuned to its photon energy slightly above the Cu K-edge, enabled 2D imaging of transmission changes induced by electron isochoric heating. Time-resolved measurements obtained by varying the time delay between the x-ray probe and the optical laser show that the signature of the electron-heated region expands at ∼25% of the speed of light in a picosecond duration. Time-integrated Cu Kα images support the electron energy and propagation distance observed with the transmission imaging. The x-ray near-edge transmission imaging with a tunable XFEL beam could be broadly applicable for imaging isochorically heated targets by laser-driven relativistic electrons, energetic protons, or an intense x-ray beam.

2.
Science ; 375(6584): 1011-1016, 2022 03 04.
Article in English | MEDLINE | ID: mdl-35143255

ABSTRACT

The Hayabusa2 spacecraft investigated the C-type (carbonaceous) asteroid (162173) Ryugu. The mission performed two landing operations to collect samples of surface and subsurface material, the latter exposed by an artificial impact. We present images of the second touchdown site, finding that ejecta from the impact crater was present at the sample location. Surface pebbles at both landing sites show morphological variations ranging from rugged to smooth, similar to Ryugu's boulders, and shapes from quasi-spherical to flattened. The samples were returned to Earth on 6 December 2020. We describe the morphology of >5 grams of returned pebbles and sand. Their diverse color, shape, and structure are consistent with the observed materials of Ryugu; we conclude that they are a representative sample of the asteroid.

3.
Semin Arthritis Rheum ; 51(4): 766-774, 2021 08.
Article in English | MEDLINE | ID: mdl-34144387

ABSTRACT

OBJECTIVE: To determine the clinical profile of axial psoriatic arthritis (PsA) in a worldwide setting. Secondly, to identify factors associated with the development of axial involvement in patients with PsA. METHODS: Data from 3684 patients with axial spondyloarthritis (axSpA) or PsA from the ASAS-perSpA study were analysed. The ASAS-perSpA is a cross-sectional study that recruited consecutive patients with SpA (as diagnosed by their rheumatologist) from 68 centers worldwide and collected patient and disease data. First, 2651 axSpA patients and 367 PsA patients with any history of axial involvement (axPsA) were compared using logistic regression to later identify predictive factors for rheumatologist diagnosis of axPsA. Secondly, 367 axPsA patients were compared with 666 PsA patients lacking axial involvement (peripheral PsA [pPsA]) and the characteristics associated with axial manifestations were explored by logistic regression analysis. RESULTS: Patients with axPsA were older and less frequently males or HLA*B27 positive in comparison with axSpA patients. Additionally, while patients with axPsA had more peripheral manifestations and psoriasis, other extra-musculoskeletal manifestations (IBD and uveitis) were more frequent in those with axSpA. In the multivariable analysis, older age at diagnosis (OR = 1.04), peripheral arthritis (OR = 7.32) and dactylitis (OR = 2.82) were significantly associated with the diagnosis of axPsA. However, uveitis (OR = 0.22), IBD (OR = 0.12), HLA*B27 carriership (OR = 0.26) or sacroiliitis on imaging (OR = 0.5) were inversely associated with axPsA diagnosis as compared to axSpA. Axial involvement in patients with PsA was significantly associated with male gender (OR = 1.68), elevated CRP (OR = 2.87) and the absence of psoriasis (OR = 0.33). CONCLUSION: In this worldwide setting axPsA was defined by rheumatologists as a unique phenotype, with disease features lying between axSpA and pure pPsA.


Subject(s)
Arthritis, Psoriatic , Sacroiliitis , Spondylarthritis , Aged , Arthritis, Psoriatic/complications , Arthritis, Psoriatic/diagnosis , Cross-Sectional Studies , HLA-B27 Antigen , Humans , Male , Spondylarthritis/complications , Spondylarthritis/diagnosis
4.
Rev Sci Instrum ; 92(1): 013510, 2021 Jan 01.
Article in English | MEDLINE | ID: mdl-33514225

ABSTRACT

In pump-probe experiments with an X-ray Free Electron Laser (XFEL) and a high-power optical laser, spatial overlap of the two beams must be ensured to probe a pumped area with the x-ray beam. A beam monitoring diagnostic is particularly important in short-pulse laser experiments where a tightly focused beam is required to achieve a relativistic laser intensity for generation of energetic particles. Here, we report the demonstration of on-shot beam pointing measurements of an XFEL and a terawatt class femtosecond laser using 2D monochromatic Kα imaging at the Matter in Extreme Conditions end-station of the Linac Coherent Light Source. A thin solid titanium foil was irradiated by a 25-TW laser for fast electron isochoric heating, while a 7.0 keV XFEL beam was used to probe the laser-heated region. Using a spherical crystal imager (SCI), the beam overlap was examined by measuring 4.51 keV Kα x rays produced by laser-accelerated fast electrons and the x-ray beam. Measurements were made for XFEL-only at various focus lens positions, laser-only, and two-beam shots. Successful beam overlapping was observed on ∼58% of all two-beam shots for 10 µm thick samples. It is found that large spatial offsets of laser-induced Kα spots are attributed to imprecise target positioning rather than shot-to-shot laser pointing variations. By applying the Kα measurements to x-ray Thomson scattering measurements, we found an optimum x-ray beam spot size that maximizes scattering signals. Monochromatic x-ray imaging with the SCI could be used as an on-shot beam pointing monitor for XFEL-laser or multiple short-pulse laser experiments.

5.
Science ; 368(6491): 654-659, 2020 05 08.
Article in English | MEDLINE | ID: mdl-32381723

ABSTRACT

The near-Earth asteroid (162173) Ryugu is thought to be a primitive carbonaceous object that contains hydrated minerals and organic molecules. We report sample collection from Ryugu's surface by the Hayabusa2 spacecraft on 21 February 2019. Touchdown images and global observations of surface colors are used to investigate the stratigraphy of the surface around the sample location and across Ryugu. Latitudinal color variations suggest the reddening of exposed surface material by solar heating and/or space weathering. Immediately after touchdown, Hayabusa2's thrusters disturbed dark, fine grains that originate from the redder materials. The stratigraphic relationship between identified craters and the redder material indicates that surface reddening occurred over a short period of time. We suggest that Ryugu previously experienced an orbital excursion near the Sun.

6.
Science ; 368(6486): 67-71, 2020 04 03.
Article in English | MEDLINE | ID: mdl-32193363

ABSTRACT

The Hayabusa2 spacecraft investigated the small asteroid Ryugu, which has a rubble-pile structure. We describe an impact experiment on Ryugu using Hayabusa2's Small Carry-on Impactor. The impact produced an artificial crater with a diameter >10 meters, which has a semicircular shape, an elevated rim, and a central pit. Images of the impact and resulting ejecta were recorded by the Deployable CAMera 3 for >8 minutes, showing the growth of an ejecta curtain (the outer edge of the ejecta) and deposition of ejecta onto the surface. The ejecta curtain was asymmetric and heterogeneous and it never fully detached from the surface. The crater formed in the gravity-dominated regime; in other words, crater growth was limited by gravity not surface strength. We discuss implications for Ryugu's surface age.

7.
Rev Sci Instrum ; 90(8): 083302, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31472598

ABSTRACT

Calibrated diagnostics for energetic particle detection allow for the systematic study of charged particle sources. The Fujifilm BAS-TR imaging plate (IP) is a reusable phosphorescent detector for radiation applications such as x-ray and particle beam detection. The BAS-TR IP has been absolutely calibrated to many low-Z (low proton number) ions, and extending these calibrations to the mid-Z regime is beneficial for the study of laser-driven ion sources. The Texas Petawatt Laser was used to generate energetic ions from a 100 nm titanium foil, and charge states Ti10+ through Ti12+, ranging from 6 to 27 MeV, were analyzed for calibration. A plastic detector of CR-39 with evenly placed slots was mounted in front of the IP to count the number of ions that correspond with the IP levels of photo-stimulated luminescence (PSL). A response curve was fitted to the data, yielding a model of the PSL signal vs ion energy. Comparisons to other published response curves are also presented, illustrating the trend of PSL/nucleon decreasing with increasing ion mass.

8.
Phys Rev Lett ; 122(15): 155002, 2019 Apr 19.
Article in English | MEDLINE | ID: mdl-31050520

ABSTRACT

The rapid heating of a thin titanium foil by a high intensity, subpicosecond laser is studied by using a 2D narrow-band x-ray imaging and x-ray spectroscopy. A novel monochromatic imaging diagnostic tuned to 4.51 keV Ti Kα was used to successfully visualize a significantly ionized area (⟨Z⟩>17±1) of the solid density plasma to be within a ∼35 µm diameter spot in the transverse direction and 2 µm in depth. The measurements and a 2D collisional particle-in-cell simulation reveal that, in the fast isochoric heating of solid foil by an intense laser light, such a high ionization state in solid titanium is achieved by thermal diffusion from the hot preplasma in a few picoseconds after the pulse ends. The shift of Kα and formation of a missing Kα cannot be explained with the present atomic physics model. The measured Kα image is reproduced only when a phenomenological model for the Kα shift with a threshold ionization of ⟨Z⟩=17 is included. This work reveals how the ionization state and electron temperature of the isochorically heated nonequilibrium plasma are independently increased.

9.
Nat Commun ; 10(1): 2308, 2019 05 24.
Article in English | MEDLINE | ID: mdl-31127111

ABSTRACT

Atomic-resolution electron microscopes utilize high-power magnetic lenses to produce magnified images of the atomic details of matter. Doing so involves placing samples inside the magnetic objective lens, where magnetic fields of up to a few tesla are always exerted. This can largely alter, or even destroy, the magnetic and physical structures of interest. Here, we describe a newly developed magnetic objective lens system that realizes a magnetic field free environment at the sample position. Combined with a higher-order aberration corrector, we achieve direct, atom-resolved imaging with sub-Å spatial resolution with a residual magnetic field of less than 0.2 mT at the sample position. This capability enables direct atom-resolved imaging of magnetic materials such as silicon steels. Removing the need to subject samples to high magnetic field environments enables a new stage in atomic resolution electron microscopy that realizes direct, atomic-level observation of samples without unwanted high magnetic field effects.

10.
Science ; 364(6437): 272-275, 2019 04 19.
Article in English | MEDLINE | ID: mdl-30890589

ABSTRACT

The near-Earth asteroid 162173 Ryugu, the target of the Hayabusa2 sample-return mission, is thought to be a primitive carbonaceous object. We report reflectance spectra of Ryugu's surface acquired with the Near-Infrared Spectrometer (NIRS3) on Hayabusa2, to provide direct measurements of the surface composition and geological context for the returned samples. A weak, narrow absorption feature centered at 2.72 micrometers was detected across the entire observed surface, indicating that hydroxyl (OH)-bearing minerals are ubiquitous there. The intensity of the OH feature and low albedo are similar to thermally and/or shock-metamorphosed carbonaceous chondrite meteorites. There are few variations in the OH-band position, which is consistent with Ryugu being a compositionally homogeneous rubble-pile object generated from impact fragments of an undifferentiated aqueously altered parent body.

11.
Science ; 364(6437): 252, 2019 04 19.
Article in English | MEDLINE | ID: mdl-30890587

ABSTRACT

The near-Earth carbonaceous asteroid 162173 Ryugu is thought to have been produced from a parent body that contained water ice and organic molecules. The Hayabusa2 spacecraft has obtained global multicolor images of Ryugu. Geomorphological features present include a circum-equatorial ridge, east-west dichotomy, high boulder abundances across the entire surface, and impact craters. Age estimates from the craters indicate a resurfacing age of [Formula: see text] years for the top 1-meter layer. Ryugu is among the darkest known bodies in the Solar System. The high abundance and spectral properties of boulders are consistent with moderately dehydrated materials, analogous to thermally metamorphosed meteorites found on Earth. The general uniformity in color across Ryugu's surface supports partial dehydration due to internal heating of the asteroid's parent body.

12.
Nat Mater ; 17(3): 243-248, 2018 03.
Article in English | MEDLINE | ID: mdl-29467504

ABSTRACT

In the past decades, many efforts have been devoted to characterizing {001} platelet defects in type Ia diamond. It is known that N is concentrated at the defect core. However, an accurate description of the atomic structure of the defect and the role that N plays in it is still unknown. Here, by using aberration-corrected transmission electron microscopy and electron energy-loss spectroscopy we have determined the atomic arrangement within platelet defects in a natural type Ia diamond and matched it to a prevalent theoretical model. The platelet has an anisotropic atomic structure with a zigzag ordering of defect pairs along the defect line. The electron energy-loss near-edge fine structure of both carbon K- and nitrogen K-edges obtained from the platelet core is consistent with a trigonal bonding arrangement at interstitial sites. The experimental observations support an interstitial aggregate mode of formation for platelet defects in natural diamond.

13.
J Microsc ; 270(2): 176-187, 2018 05.
Article in English | MEDLINE | ID: mdl-29315554

ABSTRACT

In the scanning transmission electron microscope, an accurate knowledge of detector collection angles is paramount in order to quantify signals on an absolute scale. Here we present an optical configuration designed for the accurate measurement of collection angles for both image-detectors and energy-loss spectrometers. By deflecting a parallel electron beam, carefully calibrated using a diffraction pattern from a known material, we can directly observe the projection-distortion in the post-specimen lenses of probe-corrected instruments, the 3-fold caustic when an image-corrector is fitted, and any misalignment of imaging detectors or spectrometer apertures. We also discuss for the first time, the effect that higher-order aberrations in the objective-lens pre-field has on such an angle-based detector mapping procedure.

14.
Rev Sci Instrum ; 88(6): 063502, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28668008

ABSTRACT

Simultaneous monochromatic crystal imaging at 4.5 and 8.0 keV with x-rays produced by a single short-pulse laser is presented. A layered target consisting of thin foils of titanium and copper glued together is irradiated by the 50 TW Leopard short-pulse laser housed at the Nevada Terawatt Facility. Laser-accelerated MeV fast electrons transmitting through the target induce Kα fluorescence from both foils. Two energy-selective curved crystals in the imaging diagnostic form separate monochromatic images on a single imaging detector. The experiment demonstrates simultaneous two-color monochromatic imaging of the foils on a single detector as well as Kα x-ray production at two different photon energies with a single laser beam. Application of the diagnostic technique to x-ray radiography of a high density plasma is also presented.

15.
Ultramicroscopy ; 182: 44-53, 2017 11.
Article in English | MEDLINE | ID: mdl-28654827

ABSTRACT

In this paper we report quantitative measurements of the imaging performance for the current generation of hybrid pixel detector, Medipix3, used as a direct electron detector. We have measured the modulation transfer function and detective quantum efficiency at beam energies of 60 and 80keV. In single pixel mode, energy threshold values can be chosen to maximize either the modulation transfer function or the detective quantum efficiency, obtaining values near to, or exceeding those for a theoretical detector with square pixels. The Medipix3 charge summing mode delivers simultaneous, high values of both modulation transfer function and detective quantum efficiency. We have also characterized the detector response to single electron events and describe an empirical model that predicts the detector modulation transfer function and detective quantum efficiency based on energy threshold. Exemplifying our findings we demonstrate the Medipix3 imaging performance recording a fully exposed electron diffraction pattern at 24-bit depth together with images in single pixel and charge summing modes. Our findings highlight that for transmission electron microscopy performed at low energies (energies <100keV) thick hybrid pixel detectors provide an advantageous architecture for direct electron imaging.

16.
Phys Rev Lett ; 118(20): 205001, 2017 May 19.
Article in English | MEDLINE | ID: mdl-28581770

ABSTRACT

Collimated transport of ultrahigh intensity electron current was observed in cold and in laser-shocked vitreous carbon, in agreement with simulation predictions. The fast electron beams were created by coupling high-intensity and high-contrast laser pulses onto copper-coated cones drilled into the carbon samples. The guiding mechanism-observed only for times before the shock breakout at the inner cone tip-is due to self-generated resistive magnetic fields of ∼0.5-1 kT arising from the intense currents of fast electrons in vitreous carbon, by virtue of its specific high resistivity over the range of explored background temperatures. The spatial distribution of the electron beams, injected through the samples at different stages of compression, was characterized by side-on imaging of hard x-ray fluorescence.

17.
Rev Sci Instrum ; 88(4): 043110, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28456236

ABSTRACT

We have built an absolutely calibrated, highly efficient, Bragg crystal spectrometer in von Hamos geometry. This zinc von Hamos spectrometer uses a crystal made from highly oriented pyrolytic graphite that is cylindrically bent along the non-dispersive axis. It is tuned to measure x-ray spectra in the 7-10 keV range and has been designed to be used on a Ten Inch Manipulator for the Omega and OmegaEP target chambers at the Laboratory for Laser Energetics in Rochester, USA. Significant shielding strategies and fluorescence mitigation have been implemented in addition to an imaging plate detector making it well suited for experiments in high-intensity environments. Here we present the design and absolute calibration as well as mosaicity and integrated reflectivity measurements.

18.
Phys Rev Lett ; 114(16): 166102, 2015 Apr 24.
Article in English | MEDLINE | ID: mdl-25955058

ABSTRACT

Atomic resolution at a low accelerating voltage with aberration correction is required to reduce the electron irradiation damage in scanning transmission electron microscopy imaging. However, the reduction in resolution caused by the diffraction limit becomes severe with increasing electron wavelength at low accelerating voltages. The developed aberration corrector can compensate for higher-order aberration in scanning transmission electron microscopy to expand the uniform phase angle. The resolution for imaging graphene at 30 kV is evaluated by changing the convergence angle for a probe-forming system with a higher-order aberration corrector. A single-carbon atom on graphene is successfully imaged at atomic resolution with a cold-field emission gun by dark-field imaging at an accelerating voltage of 30 kV.

19.
Phys Rev Lett ; 114(9): 095004, 2015 Mar 06.
Article in English | MEDLINE | ID: mdl-25793822

ABSTRACT

Energy loss in the transport of a beam of relativistic electrons in warm dense aluminum is measured in the regime of ultrahigh electron beam current density over 2×10^{11} A/cm^{2} (time averaged). The samples are heated by shock compression. Comparing to undriven cold solid targets, the roles of the different initial resistivity and of the transient resistivity (upon target heating during electron transport) are directly observable in the experimental data, and are reproduced by a comprehensive set of simulations describing the hydrodynamics of the shock compression and electron beam generation and transport. We measured a 19% increase in electron resistive energy loss in warm dense compared to cold solid samples of identical areal mass.

20.
Benef Microbes ; 6(3): 287-93, 2015.
Article in English | MEDLINE | ID: mdl-25380799

ABSTRACT

We investigated the effects of Streptococcus thermophilus YIT 2001, a strain of lactic acid bacteria, on the susceptibility of low-density lipoprotein (LDL) to oxidation and the formation of aortic fatty lesions in hyperlipidemic hamsters. S. thermophilus YIT 2001 had the highest in vitro antioxidative activity against LDL oxidation among the 79 strains of lactic acid bacteria and bifidobacteria tested, which was about twice that of S. thermophilus YIT 2084. The lag time of LDL oxidation in the YIT 2001 feeding group was significantly longer than in controls, but was unchanged in the YIT 2084 group. After the feeding of YIT 2001, lag times were prolonged and areas of aortic fatty lesions were dose-dependently attenuated, although there were no effects on plasma lipid levels. These results suggest that YIT 2001 has the potential to prevent the formation of aortic fatty lesions by inhibiting LDL oxidation.


Subject(s)
Aorta/metabolism , Hyperlipidemias/drug therapy , Lipoproteins, LDL/metabolism , Probiotics/administration & dosage , Streptococcus thermophilus/physiology , Animals , Aorta/pathology , Cricetinae , Humans , Hyperlipidemias/metabolism , Hyperlipidemias/microbiology , Hyperlipidemias/pathology , In Vitro Techniques , Lipids/blood , Male , Mesocricetus , Oxidation-Reduction
SELECTION OF CITATIONS
SEARCH DETAIL