1.
Med Sci Monit ; 30: e943401, 2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38444156

ABSTRACT

BACKGROUND Several auxiliary features have been proposed to achieve sustainable retention for short-prepared dental crowns; however, achieving retention is challenging. This study aimed to assess the impact of increased total occlusal convergence and auxiliary preparation factors like box and groove on the retention form of short tooth preparations. MATERIAL AND METHODS Eighty resin machine-milled dies with a height of 3 mm and a deep chamfer margin of 1 mm were prepared to mimic the short-prepared molar. Initially, 2 teeth were prepared following the guidelines, and the total occlusal convergence was kept at 10° and 20°, respectively. Auxiliary features such as the proximal box and buccal groove were prepared on separate 20° dies. Eighty dies were prepared with 10 samples each for 10°, 20°, 20° with proximal box and 20° with buccal groove for zirconia (n=40) and metal crowns (n=40). Cementation was done with glass ionomer luting cement, and a pull-off test was conducted. Data were analyzed using one-way analysis of variance and post hoc fisher least significant difference test (P<0.05). RESULTS The highest mean was observed in the proximal box group with the metal crown (14.59), and the lowest in the group with 20° zirconia crowns (9.12). Within groups, the highest retentive values were found for the 20° taper with proximal box preparation; the lowest was for the 20° taper group. CONCLUSIONS Within the study limitations, it could be concluded that incorporating a proximal box or buccal groove in short tooth preparations with an increased total occlusal convergence improved retentive values.


Subject(s)
Glass Ionomer Cements , Mouth , Zirconium , Cell Membrane , Crowns
2.
Med Sci Monit ; 30: e943706, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38500254

ABSTRACT

BACKGROUND The advent of digital impressions using computer-aided design and manufacturing technology (CAD/CAM) has simplified and improved the fabrication of implant prostheses in dentistry. The conventional impression has several drawbacks, including tray selection, material type, impression technique, impression disinfection, and cast model storage. The inaccuracies caused by distortion and contraction of impression material can be minimized with digital impressions. This study aimed to compare digital dental impressions of 10 working casts made using the Pindex laser removable die system to fabricate parallel drill channels vs 10 working casts made using the Di-Lok plastic tray removable die system. MATERIAL AND METHODS An implant master die with 2 dental implant analogs was fabricated. Ten working casts using the Pindex laser removable die system with parallel drill channels and 10 working casts using the Di-Lok plastic tray removable die system were fabricated. The working casts were scanned using an extra-oral laboratory scanner and the implant master model was scanned with an intra-oral scanner. RESULTS The properties of the casts made using the 2 systems were evaluated and analyzed with ANOVA and post hoc Tukey test. The mean horizontal linear distances between A1B1 (P<0.021), A2B2 (P<0.018), C1D1 (P<0.026), C2D2 (P<0.03), B1C1 (P<0.01), and mean vertical distances between B1A2 (P<0.015), C1D2 (P<0.001), B1B2 (P<0.028), and C1C2 (P<0.001) were significantly different between the Pindex system and Di-Lok tray system as compared to intra-oral scans. CONCLUSIONS Complete digital workflow with intra-oral scans were more than the partial digital workflow with extra-oral scans for the Pindex system and Di-Lok tray systems.


Subject(s)
Dental Implants , Models, Dental , Workflow , Computer-Aided Design , Denture, Partial, Fixed , Research Design
3.
Med Sci Monit ; 30: e943237, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38343120

ABSTRACT

BACKGROUND This study evaluated the effects of milling (CADCAM), 3D printing, preparation taper angles (10-degree and 20-degree), auxiliary retentive features (groove and box), and provisional cement types (conventional and resin-based) on the adhesive failure stress of 3-mm short provisional crowns (PC). The research was motivated by the need to understand how digital dentistry technologies impact the retention and durability of provisional crowns. MATERIAL AND METHODS A total of 160 working models (3D-printed) and PCs [80 milled (CopraTemp)/80 printed (Asiga)] were fabricated from two 10- and 20-degree typodont master models and two 20-degree 3D-printed master models (groove and box), simulating a 3 mm high all-ceramic short PC. After provisional cementation with conventional (Kerr TempBond) and resin-based (ProviTemp) cements, 16 subgroups (n=10 each) underwent thermocycling (10 000 cycles; 5-55°C) and pull-off tests on a universal testing machine. Statistical analysis was performed using one-way ANOVA and post hoc Tukey test. RESULTS Conventional cement failed at lower stress for milled (47.68 to 73.54) and printed (48.40 to 77.91) as compared to resin cement for milled (104.2 to 137.27) and printed (184.85 to 328.84), respectively, with significant differences. Increased taper and groove decreased failure load except for the printed PC/resin cement combination. Use of proximal box preparation increased retention significantly. Except for 20-degree taper cemented with conventional cement, the differences in auxiliary retentive features for milled and printed provisional crowns were statistically significant at P≤0.05. CONCLUSIONS 3D-printed PC, resin-based cement, 10-degree taper, and proximal box preparation were associated with higher retention than milled, conventional cements, 20-degree taper, and vertical groove.


Subject(s)
Adhesives , Resin Cements , Resin Cements/chemistry , Materials Testing , Crowns , Printing, Three-Dimensional , Glass Ionomer Cements , Dental Cements
4.
Med Sci Monit ; 30: e943404, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38374614

ABSTRACT

BACKGROUND Preshaded monolithic zirconia (MLZ) is reported to have high translucency. This study aimed to assess the effect of chlorhexidine gluconate (ChG) mouthwash on color and translucency parameter (TP) of 2 different preshaded MLZ dental ceramics after clinical adjustment. MATERIAL AND METHODS Two MLZ disk-shaped specimens [NPM (Nacera Pearl Multi-Shade) (n=72) and CZM (Ceramill Zolid FX Multilayer)] (n=72) were simulated for clinical adjustment, finished, and polished using 2 adjustment kits [recommended kit, third-party kit: Diasynt Plus and SUN (n=12 each)] and later immersed in ChG mouthwash (Avohex) for 2 weeks. Difference in color (ΔE) and TP (Y) were calculated using the CIELab formula after measuring the coordinates (Lab) with a colorimeter. Individual changes in color and TP were assessed on the Clinical acceptance (perceptible) threshold (CAT/CPT) and Translucency perception threshold (TPT), respectively. Differences between the 2 ceramics were assessed using one-way ANOVA and post hoc tests, with all differences considered significant at P<0.05. RESULTS NPM and CZM differed in color at baseline despite having the same Vita shade combination. Between the 2 preshaded MLZ ceramics, NPM showed significant changes in color when adjusted with a third-party kit. Chlorhexidine produced changes in color and TP that were designated as clinically perceptible (ΔE=1.0 to 3.3) on the CAT/CPT and TPT scales, irrespective of the adjustment kit used. ChG produced the least or no changes in glazed MLZ specimens. CONCLUSIONS ChG mouthwash, whenever prescribed for preshaded MLZ restoration, should be adjusted prior to final glazing to avoid clinical adjustments that adversely affects color and translucency of the restoration.


Subject(s)
Chlorhexidine , Mouthwashes , Zirconium , Color , Chlorhexidine/pharmacology , Mouthwashes/pharmacology , Immersion , Materials Testing , Surface Properties , Ceramics , Dental Porcelain
5.
Urol J ; 21(1): 29-34, 2024 Feb 28.
Article in English | MEDLINE | ID: mdl-37334741

ABSTRACT

PURPOSE: Three-Dimensional (3D) could help for planning and creating an optimal access route in percutaneous nephrolithotomy (PCNL) procedure by achieving a more accurate approach to the renal collecting system and stone treatment while decreasing the risk of complications. The aim of our study is to compare the efficacy of 3D imaging technique with standard fluoroscopy method as a guiding tool for renal stone location while striving to reduce intra-operative X-ray exposure in the former method. MATERIALS AND METHODS: This randomised clinical trial enrolled 48 PCNL candidates who were referred to Sina Hospital (Tehran, Iran). Participants were divided into two equal groups of intervention (3D virtual reconstruction) and control, using block randomization method. Age, sex, stone type and location, X-ray exposure during the procedure, stone access accuracy rate and the necessity of blood transfusion during surgery were taken into account. RESULTS: The Mean age of participants (n = 48) was 46.4 ± 4.8 years, 34 (70.8%) were male, 27 (56.3%) had partial staghorn stones and all participants had stones within the lower calyx. The radiation exposure time, stone access time and stone size were 2.99 ± 1.81 seconds, 272.3 ± 108.9 seconds and 23.06 ± 2.28 mm, respectively. In the intervention group, the accuracy rate for lower calyceal stone access was 91.5%. Also, X-ray exposure and time to stone access were significantly lower in the intervention group compared to the controls (P < 0.001). CONCLUSION: We concluded that the utilization of 3D technology in the pre-operative location of renal calculi in PCNL candidates may result in a significant improvement in the accuracy and time to access the renal calculi, as well as reduction in X-ray exposure.


Subject(s)
Kidney Calculi , Nephrolithotomy, Percutaneous , Nephrostomy, Percutaneous , Humans , Male , Adult , Middle Aged , Female , Nephrolithotomy, Percutaneous/methods , Treatment Outcome , Iran , Kidney Calculi/diagnostic imaging , Kidney Calculi/surgery , Punctures , Fluoroscopy , Nephrostomy, Percutaneous/methods
6.
Polymers (Basel) ; 15(21)2023 Oct 31.
Article in English | MEDLINE | ID: mdl-37959963

ABSTRACT

The aim of this study was to assess the shear bond strength of 3D-printed and milled provisional restorations using various resin materials and surface finishes. There were 160 preliminary samples in all, and they were split into two groups: the milled group and the 3D-printed group. Based on the resin used for repair (composite or polymethylmethacrylate (PMMA)) and the type of surface treatment utilized (chemical or mechanical), each group was further divided into subgroups. The specimens were subjected to thermocycling from 5 °C to 55 °C for up to 5000 thermal cycles with a dwell time of 30 s. The mechanical qualities of the repaired material underwent testing for shear bond strength (SBS). To identify the significant differences between the groups and subgroups, a statistical analysis was carried out. Three-way ANOVA was used to analyze the effects of each independent component (the material and the bonding condition), as well as the interaction between the independent factors on shear bond strength. Tukey multiple post-hoc tests were used to compare the mean results for each material under various bonding circumstances. The shear bond strengths of the various groups and subgroups differed significantly (p < 0.05). When compared to the milled group, the 3D-printed group had a much greater mean shear bond strength. When compared to PMMA repair, the composite resin material showed a noticeably greater shear bond strength. In terms of surface treatments, the samples with mechanical and chemical surface treatments had stronger shear bonds than those that had not received any. The results of this study demonstrate the effect of the fabrication method, resin type, and surface treatment on the shear bond strength of restored provisional restorations. Particularly when made using composite material and given surface treatments, 3D-printed provisional restorations showed exceptional mechanical qualities. These results can help dentists choose the best fabrication methods, resin materials, and surface treatments through which to increase the durability and bond strength of temporary prosthesis.

7.
Med Sci Monit Basic Res ; 29: e941919, 2023 Nov 20.
Article in English | MEDLINE | ID: mdl-37987528

ABSTRACT

BACKGROUND Replicating the 3-dimensional (3D) color of natural teeth in artificial substitutes is challenging. Fixed dental prosthodontics require aesthetic, color-stable provisional restorations. Recent milling and 3D printing digital manufacturing techniques offer improved outcomes. This study assesses color stability in various digital manufacturing methods, tapers, and aging effects on anterior provisional resin restorations. MATERIAL AND METHODS Two all-ceramic tooth preparations on typodont teeth with 10° and 20° tapers were converted into experimental dies. Forty temporary crowns were manufactured using 3D printing and computer-aided design/computer-aided manufacturing (milling). Within these 2 groups, 10 crowns were cemented using a regular and clear provisional cement. All samples were thermocycled to simulate clinical use of 6 months. Color difference formula (CIEDE2000) indicated changes between before and after cementation (ΔE00) and between after cementation and after thermocycling (ΔE00[II]). The color change was considered significant in terms of clinically perceptible (ΔE00 ≤0.62) and acceptable (ΔE00 ≤2.62) changes. One-way ANOVA (P value of less than 0.05) calculated overall differences, which were established using a Fisher post hoc test. RESULTS Crowns cemented with clear cement showed fewer color changes irrespective of the manufacturing technique or taper. Notably, only the 10° 3D-printed crown with clear cement had an imperceptible color change at the pre-/post-cementation phase. Meanwhile, the 10° and 20° milled crowns with regular cement exhibited unacceptable color changes after thermocycling. CONCLUSIONS For long­term temporization in the aesthetic zone, properly optimized 3D-printed provisional restorations cemented with clear cement had better color stability.


Subject(s)
Colorimetry , Crowns , Materials Testing , Computer-Aided Design , Glass Ionomer Cements
8.
Med Sci Monit ; 29: e941488, 2023 Nov 24.
Article in English | MEDLINE | ID: mdl-37997301

ABSTRACT

BACKGROUND The aim of this study was to assess the influence of maxillofacial prosthodontic rehabilitation on anxiety/depression severity in patients with rhino-orbital cerebral mucormycosis (ROCM) after maxillectomy. MATERIAL AND METHODS Sixty post-mucormycotic patients treated with maxillectomy (33 males, 27 females) were divided into 5 groups based on maxillectomy types (unilateral/bilateral, subtotal/total) and treatment given (psychotherapy/obturator/implant/orbital/ocular prosthesis). Anxiety and depression symptoms were assessed using appearance anxiety inventory (AAI) and patient health questionnaire (PHQ9). Data were collected at 4 time intervals [T0 (before prosthesis), T1 (2 weeks after prosthesis), T2 (6 months) and T3 (1 year). Frequency distribution and mean values were determined for individual group/subgroups/total cohort. Differences between groups were determined using one-way ANOVA (single-factor/Friedman's) followed by post hoc correction (Bonferroni) and t test for unequal variance with probability P value being statistically significant at <0.05. RESULTS The mean scores for appearance anxiety were 29.13±4.72 (diagnostic for existing body dysmorphic disorder) at T0, which decreased to 16.88±3.02 at T3 for the total cohort. The differences for the gender-based cohort, its various groups, and respective subgroups were significant (P<0.05) at various time intervals. The mean scores in the total cohort for depression symptom severity were 16.81±4.89 (moderately severe) at T0, which increased to 18.5±4.94 at T1, followed by reduction at T2 (12.0±4.43; moderate) and T3 (7.38±3.37; mild). Gender differences for both variables were found to be statistically significant (P<0.05). CONCLUSIONS Comprehensive rehabilitation that included a diagnosis of psychological symptoms followed by psychotherapeutic/pharmacotherapeutic/prosthodontic intervention reduced the anxiety/depression symptom levels to normal at 1 year.


Subject(s)
COVID-19 , Mucormycosis , Male , Female , Humans , Depression/psychology , Prosthodontics , Anxiety/psychology
9.
Med Sci Monit ; 29: e941654, 2023 Nov 04.
Article in English | MEDLINE | ID: mdl-37924203

ABSTRACT

BACKGROUND The aim of this study was to assess and compare the vertical/horizontal dimensions and occlusal accuracy of non-working/opposing casts obtained from three different impression materials and 3D print cast. MATERIAL AND METHODS Dentulous Master models simulating a case of a fixed dental prosthesis were mounted on an articulator (control group). Opposing mandibular casts obtained from three different impression materialsand 3-dimensional print constituted test groups , ,and , respectively. Three points, anterior vertical (AV), posterior vertical (PV), and anteroposterior (AP) were compared for dimensional accuracy among casts. Occlusal accuracy was analyzed on Medit Link software at 3 teeth (#13, #17, and #27). After calculating means for each group, the differences were calculated at probability value of P≤0.05 using the single-sample t test, ANOVA, and Tukey test. RESULTS The dimensions were significantly different from those of the mounted master models except in Gp AL(E) and Gp AL(F) at AV dimension and Gp AL(E) at AP dimension (P>0.05). A statistically significant difference of the error of means among the 4 tested groupswere detected only at 2 dimensions (AV and PV) between the Gp AL(E) and Gp 3D-C and between Gp AL(F) and Gp 3D-C groups. Other groups showed no significant differences. CONCLUSIONS The opposing casts obtained from the extended-pour alginate and alginate alternative impression materials showed higher occlusal accuracy compared to conventional alginate and 3D printed casts.


Subject(s)
Models, Dental , Printing, Three-Dimensional , Humans , Alginates , Mandible , Software
10.
Sensors (Basel) ; 23(17)2023 Aug 25.
Article in English | MEDLINE | ID: mdl-37687891

ABSTRACT

Healthcare 4.0 is a recent e-health paradigm associated with the concept of Industry 4.0. It provides approaches to achieving precision medicine that delivers healthcare services based on the patient's characteristics. Moreover, Healthcare 4.0 enables telemedicine, including telesurgery, early predictions, and diagnosis of diseases. This represents an important paradigm for modern societies, especially with the current situation of pandemics. The release of the fifth-generation cellular system (5G), the current advances in wearable device manufacturing, and the recent technologies, e.g., artificial intelligence (AI), edge computing, and the Internet of Things (IoT), are the main drivers of evolutions of Healthcare 4.0 systems. To this end, this work considers introducing recent advances, trends, and requirements of the Internet of Medical Things (IoMT) and Healthcare 4.0 systems. The ultimate requirements of such networks in the era of 5G and next-generation networks are discussed. Moreover, the design challenges and current research directions of these networks. The key enabling technologies of such systems, including AI and distributed edge computing, are discussed.


Subject(s)
Internet of Things , Telemedicine , Humans , Artificial Intelligence , Internet , Biological Evolution
11.
Technol Health Care ; 2023 Sep 04.
Article in English | MEDLINE | ID: mdl-37694329

ABSTRACT

BACKGROUND: Provisional fixed dental prosthesis (FDP) plays an important role during fixed prosthodontic therapy till the definitive. Discoloration of materials used for provisional FDPs can cause patient dissatisfaction and may create doubt about the color stability of the definitive FDP. Surface roughness is the other major property to be taken into consideration for provisional FDP materials. Smokeless tobacco is reported to affect the color stability and surface roughness of different prosthetic materials. OBJECTIVE: The aim of the current study was to evaluate the effect of two types of smokeless tobacco (black and white) on color stability and surface roughness of 3D printed, CAD/CAM milled, and conventional provisional FDP resin materials. METHODS: A total of 144 disc-shaped specimens were fabricated using four techniques CAD/CAM subtractive technique (milling), CAD/CAM additive technique (3D Printing), and conventional technique using autopolymerized PMMA, and autopolymerized Bis-acrylic resins. Each group was subdivided into three subgroups of twelve specimens each, and were submerged into three solutions (artificial salivary substitute, black smokeless tobacco, white smokeless tobacco). The change in color and surface roughness was evaluated and the data collected were statistically analyzed. RESULTS: It was observed that black smokeless tobacco caused the maximum color change and the effect was highest in autopolymerized PMMA resin specimens (ΔE = 9.343 ± 0.489), followed by 3D printed (ΔE = 7.187 ± 0.391), autopolymerized Bis-acryl (ΔE = 6.464 ± 0.453) and milled (ΔE = 4.978 ± 0.227). White smokeless tobacco was found to cause a maximum change in surface roughness and the effect was highest in autopolymerized Bis-acryl specimens (ΔRa = 0.321 ± 0.015 µm), followed by autopolymerized PMMA (ΔRa = 0.297± 0.015 µm), 3D printed (ΔRa = 0.191 ± 0.019 µm), and milled (ΔRa = 0.168 ± 0.014 µm). Statistically significant (p-value < 0.05) differences were observed among all techniques and solutions. CONCLUSIONS: The change in color and surface roughness were maximum in the case of FDPs prepared using autopolymerizing resins, followed by 3D printed, and CAD/CAM milled reins.

12.
PLoS One ; 18(8): e0289327, 2023.
Article in English | MEDLINE | ID: mdl-37531400

ABSTRACT

Part of the regulation of telomerase activity includes the alternative splicing (AS) of the catalytic subunit telomerase reverse transcriptase (TERT). Although a therapeutic window for telomerase/TERT inhibition exists between cancer cells and somatic cells, stem cells express TERT and rely on telomerase activity for physiological replacement of cells. Therefore, identifying differences in TERT regulation between stem cells and cancer cells is essential for developing telomerase inhibition-based cancer therapies that reduce damage to stem cells. In this study, we measured TERT splice variant expression and telomerase activity in induced pluripotent stem cells (iPSCs), neural progenitor cells (NPCs), and non-small cell lung cancer cells (NSCLC, Calu-6 cells). We observed that a NOVA1-PTBP1-PTBP2 axis regulates TERT alternative splicing (AS) in iPSCs and their differentiation into NPCs. We also found that splice-switching of TERT, which regulates telomerase activity, is induced by different cell densities in stem cells but not cancer cells. Lastly, we identified cell type-specific splicing factors that regulate TERT AS. Overall, our findings represent an important step forward in understanding the regulation of TERT AS in stem cells and cancer cells.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Induced Pluripotent Stem Cells , Lung Neoplasms , Telomerase , Humans , Alternative Splicing , Telomerase/genetics , Telomerase/metabolism , Induced Pluripotent Stem Cells/metabolism , Heterogeneous-Nuclear Ribonucleoproteins/metabolism , Polypyrimidine Tract-Binding Protein/metabolism
13.
J Parasit Dis ; 47(3): 608-618, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37520204

ABSTRACT

Toxoplasma gondii (T. gondii) is a parasite that obtains the iron it needs for its own metabolism from the host-cell iron pool. In this work, we aimed to investigate if iron supplementation or deficiency affected the course of T. gondii infection. Eighty mice were divided into four groups, each with 20 animals: Group (I): Uninfected control group. Group (II): Infected control group: injected with Phosphate buffered saline. Group (III): Infected group: received iron sucrose treatment. Group (IV): Infected group: treated with deferoxamine. Quantitative PCR studies were performed on days 3 and 8 post-infection to detect the expression of iron metabolism genes (hamp and ferroprotin) and immune-histochemical analysis to study the percentage of TNF-α and TGF-ß tissue expression. Iron supplementation induced progressions of infection evident by increased tissue expression of pro-inflammatory cytokine TNF-α and downregulation of TGF-ß which is mostly linked to suppression of the inflammatory process caused by T. gondii. Increased expression of TGF-ß and decreased expression of TNF-α was noticed when iron deprivation occurred. On day 3, we noticed increased expression in the hamp gene with iron supplementation while it decreases when the iron supply is low. On the contrary, iron deficiency increased ferroprotin gene expression whereas supplementing decreased it. On day 8, the level of expression of these genes returned to normal levels. These observations document the potential role of iron in controlling toxoplasmosis infection and indicate that the transcription of hamp and ferroprotin in T. gondii-infected cells appears to be regulated by a sophisticated indirect mechanism.

14.
Biomed Eng Online ; 22(1): 76, 2023 Jul 31.
Article in English | MEDLINE | ID: mdl-37525193

ABSTRACT

BACKGROUND: In the future, extended reality technology will be widely used. People will be led to utilize virtual reality (VR) and augmented reality (AR) technologies in their daily lives, hobbies, numerous types of entertainment, and employment. Medical augmented reality has evolved with applications ranging from medical education to picture-guided surgery. Moreover, a bulk of research is focused on clinical applications, with the majority of research devoted to surgery or intervention, followed by rehabilitation and treatment applications. Numerous studies have also looked into the use of augmented reality in medical education and training. METHODS: Using the databases Semantic Scholar, Web of Science, Scopus, IEEE Xplore, and ScienceDirect, a scoping review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) criteria. To find other articles, a manual search was also carried out in Google Scholar. This study presents studies carried out over the previous 14 years (from 2009 to 2023) in detail. We classify this area of study into the following categories: (1) AR and VR in surgery, which is presented in the following subsections: subsection A: MR in neurosurgery; subsection B: spine surgery; subsection C: oral and maxillofacial surgery; and subsection D: AR-enhanced human-robot interaction; (2) AR and VR in medical education presented in the following subsections; subsection A: medical training; subsection B: schools and curriculum; subsection C: XR in Biomedicine; (3) AR and VR for rehabilitation presented in the following subsections; subsection A: stroke rehabilitation during COVID-19; subsection B: cancer and VR, and (4) Millimeter-wave and MIMO systems for AR and VR. RESULTS: In total, 77 publications were selected based on the inclusion criteria. Four distinct AR and/or VR applications groups could be differentiated: AR and VR in surgery (N = 21), VR and AR in Medical Education (N = 30), AR and VR for Rehabilitation (N = 15), and Millimeter-Wave and MIMO Systems for AR and VR (N = 7), where N is number of cited studies. We found that the majority of research is devoted to medical training and education, with surgical or interventional applications coming in second. The research is mostly focused on rehabilitation, therapy, and clinical applications. Moreover, the application of XR in MIMO has been the subject of numerous research. CONCLUSION: Examples of these diverse fields of applications are displayed in this review as follows: (1) augmented reality and virtual reality in surgery; (2) augmented reality and virtual reality in medical education; (3) augmented reality and virtual reality for rehabilitation; and (4) millimeter-wave and MIMO systems for augmented reality and virtual reality.


Subject(s)
Augmented Reality , COVID-19 , Stroke Rehabilitation , Virtual Reality , Humans , Biomedical Engineering
15.
Med Sci Monit ; 29: e940949, 2023 Jun 30.
Article in English | MEDLINE | ID: mdl-37386761

ABSTRACT

BACKGROUND This study aimed to compare a composite resin (Duo-Shade) shade guide with Vita ceramic shades before/after chemical and autoclave sterilization. MATERIAL AND METHODS Color values (L*a*b*) were recorded directly from shade tabs of prefabricated composite resin (Brilliant NG Universal Duo-Shade) and ceramic (Vita classic) shade guide with a calibrated spectrophotometer (Vita Easy Shade Advance 4.0). Seventy-two composite resin disk samples with 6 different shades (A1/B1, A2/B2, A3/D3, A3.5/B3, A4/C4, and C2/C3) (n=12 each) were divided into 2 groups (Gp) - Gp A (Autoclave) and Gp C (Chemical) (15 cycles) - to assess their influence on respective shades. Mean values calculated the color differences (ΔE) while differences in color values (L*a*b*) were graded on the National Bureau of Standards (NBS) 6-grade scale and assessed for Clinical Acceptance/Perceptible Threshold (CAT), (CPT). All differences were considered significant if the color difference ΔE was ≥3.3. RESULTS Only 2 out of 12 Shade tabs (C2C3, A4C4) of composite resin matched to Vita shade tab C2 and C4 (ΔE ≤3.3). Both groups showed notable color differences after respective sterilization protocols, with color differences in Gp A significantly higher than Gp C (DE ³3.3). Within groups, all shades in Gp A showed remarkably different color changes, with shade C2C3 and A1B1 being denoted as clinically unacceptable. CONCLUSIONS Manufacturer-provided shade guides do not match ceramic shades as claimed and chemical sterilization using 10% Deconex was associated with less color changes than with autoclave sterilization.


Subject(s)
Composite Resins , Sterilization , Composite Resins/therapeutic use , Ceramics/therapeutic use
16.
Medicina (Kaunas) ; 59(3)2023 Mar 03.
Article in English | MEDLINE | ID: mdl-36984502

ABSTRACT

The coronal seal in root canal-treated teeth may be compromised depending on the accuracy of post space preparation and post cementation along with remaining gutta-percha. Root canal treatment can be compromised by endotoxins released by the coronal bacteria as a result of microleakage. The study was conducted by undergraduate students to measure the gap between the cemented post and residual gutta-percha. In total, 217 endodontically treated teeth were evaluated with intraoral peri-apical radiographs. Based on the intraoral periapical radiographic examination in the CS-R4 program, Group I had no gap, Group II had a gap of >0 to 2 mm, and Group III had a gap of more than 2 mm between the end of the cemented post and the remaining gutta-percha. In total, 40% (n = 87) of the teeth had no gap, 59% (127) had a gap of >0 to 2 mm, and 1% (n = 3) had a gap of more than 2 mm between the cemented post end and remaining gutta. Chi square test revealed a significant difference in the gap between the post and remaining gutta-percha between males and females students (p < 0.001). In terms of the gap between the cemented post end and the residual gutta-percha, the root canal treated teeth with post and core by undergraduates were clinically acceptable.


Subject(s)
Root Canal Filling Materials , Tooth, Nonvital , Humans , Gutta-Percha , Cross-Sectional Studies , Retrospective Studies
17.
Medicina (Kaunas) ; 59(3)2023 Mar 06.
Article in English | MEDLINE | ID: mdl-36984516

ABSTRACT

Background and Objectives: The use of desensitizing agents (DA) after tooth preparation to prevent hypersensitivity is well documented in the literature. A fixed dental prosthesis (FDP) should have good retention to be successful. Inadequate retention may result in microleakage, secondary caries, and, eventually, dislodgement of the FDP. The effect of DAs on the retention of FDPs has been widely studied in the literature, but the results are conflicting. Thus, this study aimed to conduct a systematic review to assess the effect of dentine desensitizing agents, used to prevent post-cementation hypersensitivity, on the retention of cemented FDPs. The null hypothesis framed was that there is no effect of dentine desensitizing agents on the retention of cemented FDPs. The focused PICO question was as follows: "Does the application of dentine desensitizing agents (I) affect the retention (O) of cemented fixed dental prosthesis (P) when compared to non-dentine desensitizing groups (C)"? Materials and Methods: Four electronic databases were systematically searched and, on the basis of the predefined inclusion and exclusion criteria, 23 articles were included in this systematic review. A modified CONSORT scale for in vitro studies was used to assess the quality of the selected studies, as all included studies were in vitro studies. Results: Most of the studies compared the effect of more than one type of DA on retention. The results of the selected studies varied due to differences in the composition of tested dentine DAs and types of luting cements. Conclusions: Within the limitations of this study, it can be concluded that the retention values of FDPs cemented using zinc phosphate cement were reduced with most of the DAs, whereas retention values increased when GIC, resin-modified GIC, and resin cements were used with the majority of DAs. These findings are important, as they can guide dentists in selecting the DA before cementing the crowns with the luting agent of their choice, without compromising the retention of the crowns.


Subject(s)
Crowns , Glass Ionomer Cements , Humans , Materials Testing , Stress, Mechanical , Resin Cements
18.
Appl Radiat Isot ; 196: 110784, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36989683

ABSTRACT

This study investigated the major and trace element concentrations in the sediments of the Padma River adjacent to the under-construction Rooppur Nuclear Power Plant to have baseline elemental concentration data. Instrumental Neutron Activation Analysis (INAA) was used to determine a total of twenty-three elements (Al, As, Ca, Ce, Co, Cr, Cs, Dy, Eu, Fe, Hf, La, Mn, Na, Sb, Sc, Sm, Ti, Th, U, V, Yb, and Zn). The calculation of the enrichment factor, geo-accumulation index, and pollution load index revealed that most of the sediment samples were minor to moderately contaminated by twelve elements (As, Ca, Ce, Cs, Dy, Hf, La, Sb, Sm, Th, U, and Yb). An ecological risk assessment by ecological risk factor, comprehensive potential ecological risk index, and sediment quality guidelines showed that the sampling locations were subject to harmful biological effects due to high concentrations of As and Cr in the sediments. Three multivariate statistical analyses identified two groups of elements based on their characteristics in the sediments. This study will act as baseline elemental concentration data for future studies concerning anthropogenic activities in this area.

19.
Biomedicines ; 11(2)2023 Feb 08.
Article in English | MEDLINE | ID: mdl-36831026

ABSTRACT

Tobacco consumption in its different forms can affect the optical and surface properties of dental materials that are used in the oral cavity. Thus, the present study was conducted to evaluate the effects of two commercially available smokeless tobacco products on the color stability and surface roughness of denture base resins that were fabricated using three different techniques (CAD/CAM milling, 3D printing, and conventional heat polymerization). A total of 126 denture base resin specimens were fabricated using the three different manufacturing techniques (n = 42 each). Specimens from each group were further subdivided into three subgroups (n = 14 each) and immersed in three different immersion media (a khaini suspension, a tabbaq suspension, and artificial saliva). The differences in color and surface roughness were assessed according to data that were collected and statistically analyzed using SPSS version 24.0. The tabbaq smokeless tobacco was found to cause greatest changes in color and surface roughness; the effect was observed to be highest in the 3D-printed specimens followed by the conventional heat-polymerized and CAD/CAM milled specimens. The mean changes in color and surface roughness were the highest for the tabbaq smokeless tobacco followed by the khaini smokeless tobacco and the artificial saliva. Statistically significant (p-value < 0.05) differences were observed among all techniques and suspensions. We concluded that the mean changes in color and surface roughness were significantly higher for the 3D-printed dentures compared to the conventional heat-polymerized and CAD/CAM-milled dentures. Thus, the results of the present study strengthened the concept that tobacco in any form can lead to changes in the color and surface roughness of denture base materials.

20.
Biomedicines ; 11(2)2023 Feb 15.
Article in English | MEDLINE | ID: mdl-36831106

ABSTRACT

The aim of this study is to investigate the combined effect of a digital manufacturing technique (subtractive vs. additive), preparation taper (10° vs. 20° TOC), and finish line (chamfer vs. shoulder) on the marginal adaptation of temporary crowns following cementation with a compatible temporary cement. Four mandibular first molar typodont teeth were prepared for full coverage crowns with standard 4 mm preparation height as follows: 10° TOC with the chamfer finish line, 10° TOC with the shoulder finish line, 20° TOC with the chamfer finish line and 20° TOC with the shoulder finish line. Each of the four preparation designs were subdivided into two subgroups to receive CAD/CAM milled and 3D-printed crowns (n = 10). A total of 80 temporary crowns (40 CAD/CAM milled and 40 3D-printed) were cemented to their respective die using clear temporary recement in the standard cementation technique. The samples were examined under a stereomicroscope at ×100 magnification following calibration. Linear measurements were performed at seven equidistant points on each axial surface and five equidistant points on each proximal surface. One-way ANOVA analysis and Tukey HSD (Honestly Significance Difference) were performed. The best marginal fit was seen in group 8, while the poorest fit was noted in group 2. Shoulder finish lines and 10° TOC resulted in higher marginal gaps, especially in CAD/CAM milled group. The selection of 3D-printed crowns may provide a better marginal fit within the range of clinical acceptability. Marginal gaps were within clinical acceptability (50 and 120 µm) in all groups except group 2.

SELECTION OF CITATIONS