1.
Praxis (Bern 1994) ; 109(4): 265-269, 2020.
Article in German | MEDLINE | ID: mdl-32183655

ABSTRACT

In the Same Boat: How to Support Relatives of Patients with Dementia Using Diverse Interventions Abstract. Caring for people with dementia has great psychological, physical, social, financial and spiritual effects on relatives. Support and counseling can contribute to an improved health of the relative, to the relationship with the dementia patient, as well as to better treatment (through shared decision-making/care planning) of the patient. This article reviews data from Switzerland and international studies.


Subject(s)
Dementia , Family Health , Humans , Switzerland
2.
BMC Nephrol ; 16: 62, 2015 Apr 23.
Article in English | MEDLINE | ID: mdl-25904000

ABSTRACT

BACKGROUND: Chronic kidney disease (CKD) accelerates vascular stiffening related to age. Arterial stiffness may be evaluated measuring the carotid-femoral pulse wave velocity (PWV) or more simply, as recommended by KDOQI, monitoring pulse pressure (PP). Both correlate to survival and incidence of cardiovascular disease. PWV can also be estimated on the brachial artery using a Mobil-O-Graph; a non-operator dependent automatic device. The aim was to analyse whether, in a dialysis population, PWV obtained by Mobil-O-Graph (MogPWV) is more sensitive for vascular aging than PP. METHODS: A cohort of 143 patients from 4 dialysis units has been followed measuring MogPWV and PP every 3 to 6 months and compared to a control group with the same risk factors but an eGFR > 30 ml/min. RESULTS: MogPWV contrarily to PP did discriminate the dialysis population from the control group. The mean difference translated in age between the two populations was 8.4 years. The increase in MogPWV, as a function of age, was more rapid in the dialysis group. 13.3% of the dialysis patients but only 3.0% of the control group were outliers for MogPWV. The mortality rate (16 out of 143) was similar in outliers and inliers (7.4 and 8.0%/year). Stratifying patients according to MogPWV, a significant difference in survival was seen. A high parathormone (PTH) and to be dialysed for a hypertensive nephropathy were associated to a higher baseline MogPWV. CONCLUSIONS: Assessing PWV on the brachial artery using a Mobil-O-Graph is a valid and simple alternative, which, in the dialysis population, is more sensitive for vascular aging than PP. As demonstrated in previous studies PWV correlates to mortality. Among specific CKD risk factors only PTH is associated with a higher baseline PWV. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02327962.


Subject(s)
Blood Pressure/physiology , Brachial Artery/physiopathology , Kidney Failure, Chronic/physiopathology , Pulse Wave Analysis/methods , Vascular Stiffness/physiology , Aged , Aged, 80 and over , Automation , Brachial Artery/diagnostic imaging , Cohort Studies , Female , Humans , Kidney Failure, Chronic/therapy , Male , Middle Aged , Prospective Studies , Pulse Wave Analysis/instrumentation , Renal Dialysis , Sensitivity and Specificity , Sphygmomanometers , Ultrasonography
3.
Hemodial Int ; 18(4): 825-34, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24865782

ABSTRACT

Clinical experience and experimental data suggest that intradialytic hemodynamic profiles could be influenced by the characteristics of the dialysis membranes. Even within the worldwide used polysulfone family, intolerance to specific membranes was occasionally evoked. The aim of this study was to compare hemodynamically some of the commonly used polysulfone dialyzers in Switzerland. We performed an open-label, randomized, cross-over trial, including 25 hemodialysis patients. Four polysulfone dialyzers, A (Revaclear high-flux, Gambro, Stockholm, Sweden), B (Helixone high-flux, Fresenius), C (Xevonta high-flux, BBraun, Melsungen, Germany), and D (Helixone low-flux, Fresenius, Bad Homburg vor der Höhe, Germany), were compared. The hemodynamic profile was assessed and patients were asked to provide tolerance feedback. The mean score (±SD) subjectively assigned to dialysis quality on a 1-10 scale was A 8.4 ± 1.3, B 8.6 ± 1.3, C 8.5 ± 1.6, D 8.5 ± 1.5. Kt/V was A 1.58 ± 0.30, B 1.67 ± 0.33, C 1.62 ± 0.32, D 1.45 ± 0.31. The low- compared with the high-flux membranes, correlated to higher systolic (128.1 ± 13.1 vs. 125.6 ± 12.1 mmHg, P < 0.01) and diastolic (76.8 ± 8.7 vs. 75.3 ± 9.0 mmHg; P < 0.05) pressures, higher peripheral resistance (1.44 ± 0.19 vs. 1.40 ± 0.18 s × mmHg/mL; P < 0.05) and lower cardiac output (3.76 ± 0.62 vs. 3.82 ± 0.59 L/min; P < 0.05). Hypotension events (decrease in systolic blood pressure by >20 mmHg) were 70 with A, 87 with B, 73 with C, and 75 with D (P < 0.01 B vs. A, 0.05 B vs. C and 0.07 B vs. D). The low-flux membrane correlated to higher blood pressure levels compared with the high-flux ones. The Helixone high-flux membrane ensured the best efficiency. Unfortunately, the very same dialyzer correlated to a higher incidence of hypotensive episodes.


Subject(s)
Kidney Failure, Chronic/blood , Membranes, Artificial , Renal Dialysis/instrumentation , Aged , Cross-Over Studies , Female , Hemodynamics , Humans , Male , Prospective Studies , Renal Dialysis/adverse effects , Renal Dialysis/methods