1.
Biology (Basel) ; 12(8)2023 Aug 08.
Article in English | MEDLINE | ID: mdl-37626989

ABSTRACT

OBJECTIVES: To compare the volumes and shapes of the coagulation zone (CZ) of a multi-probe RFA system (three RFA electrodes) and a single-probe MWA system from the same vendor in an ex vivo bovine liver model. MATERIAL & METHODS: A total of 48 CZs were obtained in bovine liver specimens with three different ablation system configurations (single-probe MWA vs. multi-probe RFA with 20 mm inter-probe distance [confluent CZ] vs. multi-probe RFA with 50 mm inter-probe distance [three individual CZs]) at 4, 6, 8, and 10 min ablation time using a fixed ablation protocol. Ablation diameters were measured and ellipticity indices (EIs) and volumes calculated. Calculations for all systems/configurations were compared. RESULTS: Volumes and diameters increased with ablation time for all configurations. At 4 and 6 min ablation time volumes obtained with the RFA 50 mm setup, and at 8 and 10 min with the RFA 20 mm setup were the largest at 26.5 ± 4.1 mL, 38.1 ± 5.8 mL, 46.3 ± 4.9 mL, 48.4 ± 7.3 mL, respectively. The single-probe MWA could not reach the volumes of the RFA setups for any of the ablation times evaluated. EI were very similar and almost round for RFA 20 mm and single-probe MWA, and differed significantly to the more ovoid ones for the RFA 50 mm configuration. CONCLUSIONS: The multi-probe RFA system employing three electrodes achieved significantly larger ablation volumes in both configurations (confluent CZ and three individual CZs) per time as compared with a single-probe MWA system in this ex vivo bovine liver model.

2.
Diagnostics (Basel) ; 13(13)2023 Jun 29.
Article in English | MEDLINE | ID: mdl-37443602

ABSTRACT

OBJECTIVE: To evaluate two different dual-energy computed tomography (DECT) post-processing protocols for the detection of MSU deposits in foot tendons of cadavers with verification by polarizing light microscopy as the gold standard. MATERIAL AND METHODS: A total of 40 embalmed cadavers (15 male; 25 female; median age, 82 years; mean, 80 years; range, 52-99; SD ± 10.9) underwent DECT to assess MSU deposits in foot tendons. Two postprocessing DECT protocols with different Hounsfield unit (HU) thresholds, 150/500 (=established) versus 120/500 (=modified). HU were applied to dual source acquisition with 80 kV for tube A and 140 kV for tube B. Six fresh cadavers (4 male; 2 female; median age, 78; mean, 78.5; range 61-95) were examined by DECT. Tendon dissection of 2/6 fresh cadavers with positive DECT 120 and negative DECT 150 studies were used to verify MSU deposits by polarizing light microscopy. RESULTS: The tibialis anterior tendon was found positive in 57.5%/100% (DECT 150/120), the peroneus tendon in 35%/100%, the achilles tendon in 25%/90%, the flexor halluces longus tendon in 10%/100%, and the tibialis posterior tendon in 12.5%/97.5%. DECT 120 resulted in increased tendon MSU deposit detection, when DECT 150 was negative, with an overall agreement between DECT 150 and DECT 120 of 80% (p = 0.013). Polarizing light microscope confirmed MSU deposits detected only by DECT 120 in the tibialis anterior, the achilles, the flexor halluces longus, and the peroneal tendons. CONCLUSION: The DECT 120 protocol showed a higher sensitivity when compared to DECT 150.

3.
Acad Radiol ; 30(12): 3047-3055, 2023 12.
Article in English | MEDLINE | ID: mdl-37117142

ABSTRACT

RATIONALE AND OBJECTIVES: To evaluate the targeting accuracy of laser-guided punctures in combination with an aiming device for computed tomography (CT) interventions during in vitro experiments. MATERIALS AND METHODS: A total of 600 CT-guided punctures were performed using a laser target system, half of them with the additional help of an aiming device. Conically shaped targets in a plexiglass phantom were punctured. The planning CT data sets were acquired with 1.25, 2.5 and 5 mm slice thickness. Needle placement accuracy, as well as procedural time, was assessed. The Euclidean (ED) and normal distances (ND) were calculated at the target point. RESULTS: Using the aiming device, the accomplished mean ND at the target for the 1.25, 2.5 and 5 mm slice thickness was 1.76 mm (SD ± 0.92), 2.09 mm (SD ± 1.06) and 1.93 mm (SD ± 1.38), respectively. Without aiming device, the corresponding results were 2.55 mm (SD ± 1.42), 2.7 mm (SD ± 1.43) and 2.31 mm (SD ± 1.64). At a slice thickness of 1.25 mm and 2.5 mm, punctures with the aiming device were significantly more accurate for both the ED and ND as compared to the punctures without aiming device (p < 0.001). The mean time required to complete the procedure, including image acquisition, trajectory planning, the placement of 10 needles, and the control-CT scan was 24.8 min without and 29.8 min with the aiming device. CONCLUSION: The additional use of the aiming device in combination with the commercially available laser guidance system significantly increased the level of accuracy during this in vitro experiment compared to freehand passes.


Subject(s)
Needles , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Punctures/methods , Phantoms, Imaging , Lasers
4.
Biology (Basel) ; 12(2)2023 Jan 22.
Article in English | MEDLINE | ID: mdl-36829454

ABSTRACT

PURPOSE: To compare the results of a novice with those of experienced interventional radiologists (IRs) for stereotactic radiofrequency ablation (SRFA) of malignant liver tumors in terms of safety, technical success, and local tumor control. METHODS: A database, including all SRFA procedures performed in a single center between January 2011 and December 2018 was retrospectively analyzed. A total of 39 ablation sessions performed by a novice IR were compared to the results of three more experienced IRs. Comparative SRFA sessions were selected using propensity score matching considering tumor type, age, sex, tumor size, and tumor number as matching variables. Overall, 549 target tumors were treated in 273 sessions. Median tumor size was 2.2 cm (1.0-8.5 cm) for 178 hepatocellular carcinomas (HCCs) and 3.0 cm (0.5-13.0 cm) for 371 metastases. A median of 2 (1-11) tumors were treated per session. RESULTS: No significant differences were observed when comparing the results of more experienced IRs with those of a novice IR regarding the rates of major complications (6.8% [16/234] vs. 5.1% [2/39]; p = 0.477), mortality (1.3% [2/234] vs. 0% [0/39]; p = 0.690), primary technical efficacy (98.5% [525/533] vs. 98.9% [94/95]; p = 0.735), and local recurrence (5.6% [30/533] vs. 5.3% [5/95]; p = 0.886). However, the median planning/placement time was significantly shorter for the experienced IRs (92 min vs. 119 min; p = 0.002). CONCLUSIONS: SRFA is a safe, effective, and reliable treatment option for malignant liver tumors and favorable outcomes can be achieved even by inexperienced operators with minimal supervision.

5.
Med Ultrason ; 25(3): 355-358, 2023 Sep 29.
Article in English | MEDLINE | ID: mdl-36191245

ABSTRACT

Arterial pseudoaneurysms (PSAs) typically occur after (iatrogenic) damage (i.e., puncture) to the arterial wall and are the most frequent complication following percutaneous interventions.In this article we report on successful treatments of two iatrogenic PSAs in two patients (87-year-old male; 69-yearold-female) with a brachial (10 x 7 mm; 10 mm-length "neck") and radial (17 x 7 mm; 3 mm-length "neck") artery PSA by US-guided fibrin glue injection (UGFI). Both PSAs were effectively occluded without any complications. To our knowledge this is the first report on successful treatments of upper limb artery PSAs using UGFI, which may represent a valid first-line, minimally invasive treatment option for brachial artery PSA.


Subject(s)
Aneurysm, False , Male , Humans , Female , Aged, 80 and over , Aged , Aneurysm, False/diagnostic imaging , Aneurysm, False/therapy , Aneurysm, False/etiology , Fibrin Tissue Adhesive/therapeutic use , Prostate-Specific Antigen , Ultrasonography, Interventional , Upper Extremity , Iatrogenic Disease , Arteries , Femoral Artery/diagnostic imaging , Treatment Outcome
6.
J Clin Med ; 11(13)2022 Jun 28.
Article in English | MEDLINE | ID: mdl-35807029

ABSTRACT

Background: Robotic-based guidance systems are becoming increasingly capable of assisting in needle placement during interventional procedures. Despite these technical advances, less sophisticated low-cost guidance devices promise to enhance puncture accuracy compared with the traditional freehand technique. Purpose: To compare the in vitro accuracy and feasibility of two different aiming devices for computed-tomography (CT)-guided punctures. Methods: A total of 560 CT-guided punctures were performed by using either a robotic (Perfint Healthcare: Maxio) or a novel low-cost patient-mounted system (Medical Templates AG: Puncture Cube System [PCS]) for the placement of Kirschner wires in a plexiglass phantom with different slice thicknesses. Needle placement accuracy as well as procedural time were assessed. The Euclidean (ED) and normal distances (ND) were calculated at the entry and target point. Results: Using the robotic device, the ND at the target for 1.25 mm, 2.5 mm, 3.75 mm and 5 mm slice thickness were 1.28 mm (SD ± 0.79), 1.25 mm (SD ± 0.81), 1.35 mm (SD ± 1.00) and 1.35 mm (SD ± 1.03). Using the PCS, the ND at the target for 1 mm, 3 mm and 5 mm slices were 3.84 mm (SD ± 1.75), 4.41 mm (SD ± 2.31) and 4.41 mm (SD ± 2.11), respectively. With all comparable slice thicknesses, the robotic device was significantly more accurate compared to the low-cost device (p < 0.001). Needle placement with the PCS resulted in lower intervention time (mean, 158.83 s [SD ± 23.38] vs. 225.67 s [SD ± 17.2]). Conclusion: Although the robotic device provided more accurate results, both guidance systems showed acceptable results and may be helpful for interventions in difficult anatomical regions and for those requiring complex multi-angle trajectories.

7.
Eur Radiol ; 32(10): 6769-6776, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35678863

ABSTRACT

OBJECTIVES: To evaluate the targeting accuracy of stereotactic punctures based on a hybrid robotic device in combination with optical tracking-a phantom study. METHODS: CT data sets of a gelatin-filled plexiglass phantom with 1-, 3-, and 5-mm slice thickness were acquired. An optical navigation device served for planning of a total of 150 needle trajectories. All punctures were carried out semi-automatically with help of the trackable iSYS-1 robotic device. Conically shaped targets inside the phantom were punctured using Kirschner wires. Up to 8 K-wires were positioned sequentially based on the same planning CT and placement accuracy was assessed by taking control CTs and measuring the Euclidean (ED) and normal distances (NDs) between the wire and the entry and target point. RESULTS: Using the StealthStation S7, the accomplished mean ND at the target for the 1-mm, 3-mm, and 5-mm slice thickness was 0.89 mm (SD ± 0.42), 0.93 mm (SD ± 0.45), and 0.73 mm (SD ± 0.50), respectively. The corresponding mean ED was 1.61 mm (SD ± 0.36), 2.04 mm (SD ± 0.59), and 1.76 mm (SD ± 0.45). The mean duration of the total procedure was 27.9 min, including image acquisition, trajectory planning, registration, placement of 8 wires, and the control-CT. CONCLUSIONS: The optically tracked iSYS-1 robot allows for precise punctures in a phantom. The StealthStation S7 provided acceptable results and may be helpful for interventions in difficult anatomical regions and for those requiring complex multi-angle trajectories. In combination with our optical navigation tool, the trackable robot unit allows to cover a large treatment field and the compact design facilitates placement of needle-like instruments. KEY POINTS: • The use of a robotic targeting device in combination with optical tracking (hybrid system) allows for accurate placement of needle-like instruments without repeated control imaging. • The compact robotic positioning unit in combination with a camera for optical tracking facilitates sequential placement of multiple K-wires in a large treatment volume.


Subject(s)
Robotic Surgical Procedures , Robotics , Humans , Imaging, Three-Dimensional , Phantoms, Imaging , Punctures
8.
Int J Hyperthermia ; 39(1): 780-787, 2022.
Article in English | MEDLINE | ID: mdl-35654476

ABSTRACT

OBJECTIVES: This study aimed to assess the safety and efficacy of stereotactic radiofrequency ablation (SRFA) in patients with hepatocellular adenomas (HCA). METHODS: Retrospective analyses of all patients referred for SRFA treatment at our institution between January 2010 and October 2020 revealed 14 patients (10 women; mean age 34.4 [range, 17-73 years]) with 38 HCAs treated through 18 ablation sessions. Ablations were considered successful if a safety margin >5 mm was achieved. Demographic, interventional, and outcome data were collected and analyzed. Primary and secondary technical efficacy rates were assessed based on follow-up images consisting of contrast-enhanced CT or MR scans. RESULTS: The mean tumor size was 22 mm (range, 7-75 mm). Overall, 37/38 (97.4%) tumors were successfully ablated at the initial SRFA (primary efficacy rate of 97.4%). The median follow-up duration was 49.6 months. No deaths or adenoma-related complications (hemorrhage or malignant transformation) were observed. Disease-free survival rates at 1, 3, and 5 years from the date of the first SRFA were 100%, 85.8%, and 85.8%, respectively. Two patients developed new distant tumors retreated with consecutive re-ablation. No major complications occurred during any of the 18 ablation sessions. CONCLUSIONS: Percutaneous thermal ablation is efficient in the treatment of HCAs and may thus be considered a valid first-line treatment option. In addition, SRFA allows for an effective, minimally invasive treatment of large and multiple hepatic tumors within one session.


Subject(s)
Adenoma, Liver Cell , Carcinoma, Hepatocellular , Liver Neoplasms , Radiofrequency Ablation , Adenoma, Liver Cell/surgery , Adult , Carcinoma, Hepatocellular/surgery , Female , Humans , Liver Neoplasms/pathology , Retrospective Studies
9.
Int J Hyperthermia ; 39(1): 421-430, 2022.
Article in English | MEDLINE | ID: mdl-35227136

ABSTRACT

PURPOSE: To assess the technical outcome and local tumor control of multi-probe stereotactic radiofrequency ablation (SRFA) in a large series of patients. Furthermore, to determine factors accounting for adverse outcomes. MATERIAL AND METHODS: Between 2003 and 2018, 865 patients were treated by SRFA for 2653 primary and metastatic liver tumors with a median tumor size of 2.0 cm (0.5 - 19 cm). Primary technical efficacy (PTE) and local recurrence (LR) were evaluated, and possible predictors for adverse events analyzed using uni- and multi-variable binary logistic regression. RESULTS: Overall, 2553 of 2653 tumors were successfully ablated at initial SRFA resulting in a PTE rate of 96.2%. Predictors of lower PTE rates were age > 70 years, tumor size > 5 cm, number of probes, location close to liver capsule/organs and segment II. LR occurred in 220 of 2653 tumors (8.3%) with the following predictors: age, tumor type/size, conglomerates, segments I/IVa/IVb, number of probes and location close to major vessels/bile duct. Multivariable analysis revealed tumor size > 5 cm (odds ratio [OR] 3.153), age > 70 years (OR 1.559), and location in segment II (OR 1.772) as independent prognostic factors for PTE, whereas tumor location close to major vessels (OR 1.653) and in segment IVb (OR 2.656) were identified as independent prognostic factors of LR. CONCLUSIONS: Stereotactic RFA is an attractive option in the management of primary or metastatic liver tumors with good local tumor control, even in large tumors. The presented prognostic factors for adverse local oncological outcome might help to stratify unfavorable tumors for ablation.


Subject(s)
Carcinoma, Hepatocellular , Catheter Ablation , Liver Neoplasms , Radiofrequency Ablation , Aged , Carcinoma, Hepatocellular/surgery , Catheter Ablation/methods , Humans , Liver Neoplasms/pathology , Neoplasm Recurrence, Local/surgery , Prognosis , Radiofrequency Ablation/methods , Retrospective Studies , Treatment Outcome
10.
HPB (Oxford) ; 24(7): 1044-1054, 2022 07.
Article in English | MEDLINE | ID: mdl-34887174

ABSTRACT

BACKGROUND: Radiofrequency ablation (RFA) is subject to "heat-sink" effects, particularly for treatment of tumors adjacent to major vessels. METHODS: In this retrospective study, 104 patients with 137 tumors (40 HCC, 10 ICC and 54 metastatic liver tumors) close to (≤1 cm from) the hepatic venous confluence underwent stereotactic RFA (SRFA) between June 2003 and June 2018. Median tumor size was 3.7 cm (1.4-8.5) for HCC, 6.4 cm (0.5-11) for ICC and 3.8 cm (0.5-13) for metastases. Endpoints comprised safety, local tumor control, overall and disease-free survival. RESULTS: The overall major complication rate was 16.0% (20/125 ablations), where 8 (40%) were successfully treated by the interventional radiologist in the same anesthetic session and did not prolong hospital stay. 134/137 (97.8%) tumors were successfully ablated at initial SRFA. Local recurrence (LR) developed in 19/137 tumors (13.9%). The median and overall survival (OS) rates at 1-, 3-, and 5- years from the date of the first SRFA were 51.5 months, 73.5%, 67.0%, and 49.7% for HCC, 14.6 months, 60.0%, 32.0% and 32.0% for ICC and 38.1 months, 91.4%, 56.5% and 27.9% for metastatic disease, respectively. CONCLUSION: SRFA represents a viable alternative to hepatic resection for challenging tumors at the hepatic venous confluence.


Subject(s)
Carcinoma, Hepatocellular , Catheter Ablation , Liver Neoplasms , Radiofrequency Ablation , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/surgery , Catheter Ablation/adverse effects , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Neoplasm Recurrence, Local , Radiofrequency Ablation/adverse effects , Retrospective Studies , Treatment Outcome
12.
Cardiovasc Intervent Radiol ; 44(8): 1184-1193, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33825059

ABSTRACT

PURPOSE: To evaluate safety, local oncological control, long-term outcome and potential prognostic factors of stereotactic RFA (SRFA) for the treatment of BCLMs. METHODS: Between July 2003 and December 2019, 42 consecutive female patients with median age 54.0 years were treated with SRFA at our institution for 110 BCLMs in 48 ablation sessions. Median tumor size was 3.0 cm (0.8-9.0). Eighteen (42.9%) patients had extrahepatic metastasis at initial SRFA. RESULTS: Technical success rate was 100%, i.e., all coaxial needles were inserted with appropriate accuracy within 10 mm off plan and 107/110 (92.3%) BCLMs were successfully ablated at initial SRFA. Four Grade 1 (8.3%, 4/48) and one Grade 2 (2.1%, 1/48) complications occurred. No perioperative deaths occurred. Local recurrence developed in 8 of 110 tumors (7.3%). Overall survival (OS) rates of all patients at 1, 3, and 5 years from the date of the first SRFA were 84.1%, 49.3%, and 20.8% with a median OS of 32.3 months. Univariable cox regression analyses revealed age > 60 years and extrahepatic disease (without bone only metastases) as significant predictors of worse OS (p = 0.013 and 0.025, respectively). Size and number of metastases, hormone receptor status and time onset did not significantly affect OS after initial SRFA. CONCLUSIONS: SRFA is a safe, minimally invasive treatment option in the management of BCLMs, especially in younger patients without advanced extrahepatic metastasis, including those with large liver tumors.


Subject(s)
Breast Neoplasms/pathology , Liver Neoplasms/secondary , Liver Neoplasms/surgery , Radiofrequency Ablation/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Liver/diagnostic imaging , Liver/surgery , Liver Neoplasms/diagnostic imaging , Middle Aged , Retrospective Studies , Survival Rate , Time , Tomography, X-Ray Computed , Treatment Outcome