Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-37820471

ABSTRACT

Tattoos have been gaining popularity in recent years, leading to a growing interest in researching tattoo inks and the tattooing process itself. Since the exposure to soluble tattoo ink ingredients has not yet been investigated, we here present the method validation for a short-term biokinetics study on soluble tattoo ink ingredients. The three tracers 4-aminobenzoic acid (PABA), 2-phenoxyethanol (PEtOH) and iodine will be added to commercially available tattoo inks, which will subsequently be used on healthy study participants. Following the tattooing process, blood and urine will be sampled at specific time points and analysed for these tracers. For this purpose, a method using liquid chromatography separation coupled to a quadrupole time-of-flight mass spectrometer (LC-QTOF-MS) in positive and negative ESI mode for the quantification of PABA, PEtOH and selected metabolites and an inductively-coupled plasma (ICP)-MS method for the determination of iodine were developed and validated. For LC-QTOF-MS analysis, the most applicable additives for LC eluents (0.01 % formic acid for positive and 0.005 % acetic acid for negative mode) were identified. Protein precipitation with acetonitrile was chosen for sample preparation. The methods were validated for selectivity, specificity, carryover, linearity, limit of detection (LOD) and quantification (LOQ), matrix effects, accuracy and precision, stability under different conditions and dilution integrity according to national and international guidelines with an allowed maximum variation of ±15 %. The LC-QTOF-MS method met the imposed guideline criteria for most parameters, however, some metabolites showed strong matrix effects. Validation of the ICP-MS method revealed that the KED-H2 collision mode is superior to the standard analysis mode due to enhanced method accuracy. The methods were validated for the relevant matrices plasma, urine, tattoo ink and tattoo consumables and proved to be applicable for the main target substances in the short-term biokinetics study. A proof-of-concept study showed successful quantification of iodine and PABA metabolites. The PEtOH metabolite was also quantified, but showed strong matrix effects in urine. Therefore standard addition was selected as an alternative quantification method.


Subject(s)
Iodine , Tattooing , Humans , 4-Aminobenzoic Acid , Ink , Mass Spectrometry/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...