Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Rofo ; 196(4): 371-380, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37967821

ABSTRACT

PURPOSE: Intensive care unit (ICU) patients have a high risk of developing complications when leaving the ICU for diagnostic procedures or therapeutic interventions. Our study examined the frequency of adverse events associated with magnetic resonance imaging (MRI) of intensive care patients and the extent of changes in therapy due to the MRI scan to weigh the risks associated with the scan against the potential benefits of an MR scan, using a change in therapy as an indicator of benefit. MATERIALS AND METHODS: 4434 ICU patients (January to December 2015) were identified by Hospital Information System (SAP-R/3 IS-H, Walldorf, Germany), ICU patient data management system Metavision (iMDsoft, Israel), and Radiology Information System (Nexus.medRIS, Version 8.42, Nexus, Germany). All intensive care and medical records (HIS) and MRI reports (RIS) were matched and further evaluated in a retrospective case-to-case analysis for biometric data, mechanical ventilation, ICU requirements, planned postoperative vs. emergency diagnostic requirements, complications and impact on further diagnosis or therapy. RESULTS: Out of 4434 ICU patients, 322 ICU patients (7.3 %) underwent a total of 385 MRI examinations. 167 patients needed a total of 215 emergency scans, while 155 patients underwent 170 planned postoperative MRI exams. 158 (94.6 %) out of 167 emergency scan patients were ventilated under continuous intravenous medication and monitoring. In the planned postoperative group, only 6 (3.9 %) out of 155 were ventilated, but a total of 38 (24.5 %) were under continuous medication. 111 patients were accompanied by nurses only during MRI. Only one severe adverse event (0.3 %) was noted and was attributed to study preparation (n = 385). In 8 MRI examinations (2.1 %), the examination was interrupted or cancelled due to the patients' condition. While all MRI examinations in the planned group were completed (n = 170, 100 %) (e. g., postoperative controls), only 207 out of 215 (96.3 %) could be performed for emergency diagnostic reasons. MRI influenced the clinical course with a change in diagnosis or therapy in 74 (19.2 %) of all 385 MRI examinations performed, and in the emergency diagnostic group it was 31.2 % (n = 67/215). CONCLUSION: Nearly 20 % of MRI examinations of ICU patients resulted in a change of therapy. With only one potentially life-threatening adverse event (0.3 %) during transport and the MRI examination, the risk seems to be outweighed by the diagnostic benefit. KEY POINTS: · The risk of adverse events associated with MRI scans in ICU patients is low.. · The rate of premature termination of ICU patients' MRI scans is low.. · Almost 20 % of ICU patients' MRI scans lead to a change of therapy..


Subject(s)
Critical Care , Intensive Care Units , Humans , Retrospective Studies , Critical Care/methods , Academic Medical Centers , Magnetic Resonance Imaging
2.
Tomography ; 9(4): 1434-1442, 2023 07 27.
Article in English | MEDLINE | ID: mdl-37624107

ABSTRACT

The aim was to evaluate the additive clinical value of an additional post-procedural control-scan after CT-guided percutaneous abscess drainage (PAD) placement with contrast medium (CM) via the newly placed drain. All CT-guided PADs during a 33-month period were retrospectively analyzed. We analyzed two subgroups, containing patients with and without surgery before intervention. Additionally, radiological records were reevaluated, concerning severe inflammatory response syndrome (SIRS) during the intervention. A total of 499 drainages were placed under CT-guidance in 352 patients. A total of 197 drainages were flushed with CM directly after the intervention, and 51 (26%) showed an additional significant finding. An immediate change of therapy was found in 19 cases (9%). The subgroup that underwent surgery (120 CM-drainages; 32 (27%) additional findings; 13 (11%) immediate changes of therapy) showed no statistically significant difference compared to the subgroup without surgery (77 CM-drainages; 19 (25%) additional findings; 5 (6%) immediate changes of therapy). SIRS occurred in 2 of the 197 flushed drainages (1%) after CM application. An additional scan with CM injection via the newly placed drain revealed clinically significant additional information in almost 26% of the drainages reviewed in this study. In 9% of the cases this information led to an immediate change of therapy. Risks for SIRS are low.


Subject(s)
Abscess , Drainage , Humans , Abscess/diagnostic imaging , Abscess/therapy , Retrospective Studies , Contrast Media , Tomography, X-Ray Computed , Systemic Inflammatory Response Syndrome/diagnostic imaging , Systemic Inflammatory Response Syndrome/therapy
3.
J Otolaryngol Head Neck Surg ; 52(1): 28, 2023 Apr 21.
Article in English | MEDLINE | ID: mdl-37085925

ABSTRACT

BACKGROUND: When performing magnetic resonance imaging (MRI) in patients with a cochlear implant (CI), complication rates vary widely in the literature. The primary objective of this retrospective study was to determine the prevalence of complications, in particular magnet dislocation, in patients with CI undergoing 1.5 Tesla (T) MRI. As a secondary objective, the prevalence of magnet dislocation for specific cochlear implant device types was elaborated. METHODS: In a single-center retrospective study, all patients with a cochlear implant presenting for an MRI examination at 1.5 T at our institution between January 1st, 2010 and December 31st, 2020 were included. Implants with axial and diametrical magnets were included in the study. MRI safety measures were applied before imaging. The prevalence of complications was evaluated. Magnet dislocation rates were calculated for device types with at least 20 MRI exposures. RESULTS: During the study period, 196 MRI examinations were performed in a total of 128 patients, accounting for 149 different implants (21 implanted bilaterally) with a total of 231 implant exposures to MRI (average 1.69 ± 1.57; min. 1, max. 12). Complications were reported in 50 out of 231 cochlear implant exposures (21.6%). Magnet dislocation occurred in a total of 27 cases (11.7%). Dislocation rates were 29.6% for the Cochlear® CI500 series (24 dislocations from 81 exposures), 1.1% for the Cochlear® CI24RE series (1 from 87) and 0% for the MED-EL® Synchrony (0 from 36). The dislocation rate for the CI500 was significantly higher than for the CI24RE (χ2(1) = 26.86; p < 0.001; ϕ = 0.40) or the Synchrony (χ2(1) = 13.42; p < 0.001; ϕ = 0.34). CONCLUSIONS: For 1.5 T MRI, the risk of magnet dislocation ranges from 0 to 29.6% and depends on the CI device type. Implants with a diametrical magnet can be considered potentially MRI-safe, whereas in CIs with axial magnets, the CI500 is at high risk of magnet dislocation. Therefore, apart from a strict indication for an MRI and adherence to safety protocols, post-MRI follow-up examination to rule out magnet dislocation is recommended.


Subject(s)
Cochlear Implantation , Cochlear Implants , Humans , Cochlear Implants/adverse effects , Retrospective Studies , Magnets , Cochlear Implantation/adverse effects , Magnetic Resonance Imaging
4.
Tomography ; 9(2): 681-692, 2023 03 16.
Article in English | MEDLINE | ID: mdl-36961013

ABSTRACT

BACKGROUND: Modern ultrasound (US) shear-wave dispersion (SWD) and attenuation imaging (ATI) can be used to quantify changes in the viscosity and signal attenuation of the liver parenchyma, which are altered in hepatic steatosis. We aimed to evaluate modern shear-wave elastography (SWE), SWD and ATI for the assessment of hepatic steatosis. METHODS: We retrospectively analyzed the US data of 15 patients who underwent liver USs and MRIs for the evaluation of parenchymal disease/liver lesions. The USs were performed using a multifrequency convex probe (1-8 MHz). The quantitative US measurements for the SWE (m/s/kPa), the SWD (kPa-m/s/kHz) and the ATI (dB/cm/MHz) were acquired after the mean value of five regions of interest (ROIs) was calculated. The liver MRI (3T) quantification of hepatic steatosis was performed by acquiring proton density fat fraction (PDFF) mapping sequences and placing five ROIs in artifact-free areas of the PDFF scan, measuring the fat-signal fraction. We correlated the SWE, SWD and ATI measurements to the PDFF results. RESULTS: Three patients showed mild steatosis, one showed moderate steatosis and eleven showed no steatosis in the PDFF sequences. The calculated SWE cut-off (2.5 m/s, 20.4 kPa) value identified 3/4 of patients correctly (AUC = 0.73, p > 0.05). The SWD cut-off of 18.5 m/s/kHz, which had a significant correlation (r = 0.55, p = 0.034) with the PDFF results (AUC = 0.73), identified four patients correctly (p < 0.001). The ideal ATI (AUC = 0.53 (p < 0.05)) cut-off was 0.59 dB/cm/MHz, which showed a significantly good correlation with the PDFF results (p = 0.024). CONCLUSION: Hepatic steatosis can be accurately detected using all the US-elastography techniques applied in this study, although the SWD and the SWE showed to be more sensitive than the PDFF.


Subject(s)
Elasticity Imaging Techniques , Humans , Elasticity Imaging Techniques/methods , Retrospective Studies , Liver/diagnostic imaging , Ultrasonography/methods , Magnetic Resonance Imaging/methods
5.
Clin Hemorheol Microcirc ; 83(4): 397-408, 2023.
Article in English | MEDLINE | ID: mdl-36683499

ABSTRACT

BACKGROUND: Cervical lymphadenopathy can be benign or malignant. Its accurate diagnosis is necessary to determine appropriate treatment. Ultrasound-guided core needle biopsies (US-CNBs) are frequently used as a percutaneous sampling approach. OBJECTIVES: Our aim was to identify the efficacy and safety of US-CNBs in 125 patients with cervical lymphadenopathy and clinically suspected head and neck cancer during the COVID-19 pandemic with limited surgical resources. METHODS: US-CNBs of pathological lymph nodes were performed in 146 lymph nodes on 125 patients. Biopsies were performed ultrasound-guided with a reusable gun core biopsy system and a 10-cm-long 16-G needle. Standard of reference for the histological findings were panendoscopy, clinical and sonographic follow-up, surgical biopsy or a repeat US-CNB. RESULTS: Adequate material for histologic diagnosis was obtained in 111 patients (89%), of these 83 patients (75%) were diagnosed as malignant, whereas benign lymphadenopathy accounted for 28 patients (25%). Therefore, US-CNB was able to identify malignant or benign lymphadenopathy with an overall accuracy of 88% and 90%, respectively. CONCLUSIONS: Percutaneous US-CNB is a safe and effective alternative to surgical biopsy in the management of cervical lymphadenopathy in patients with clinically suspected head and neck cancer in a setting with limited resources.


Subject(s)
COVID-19 , Head and Neck Neoplasms , Lymphadenopathy , Humans , Biopsy, Large-Core Needle , Pandemics , Lymphadenopathy/diagnostic imaging , Image-Guided Biopsy , Head and Neck Neoplasms/diagnostic imaging , Ultrasonography, Interventional , Retrospective Studies
6.
Curr Oncol ; 30(1): 1164-1173, 2023 01 13.
Article in English | MEDLINE | ID: mdl-36661738

ABSTRACT

(1) Background: cervical cancer is one of the leading causes of cancer-related deaths and the fourth most common cancer among women worldwide. Magnetic resonance imaging (MRI) is the modality of choice for loco-regional staging of cervical cancer in the primary diagnostic workup beginning with at least stage IB. (2) Methods: we retrospectively analyzed 16 patients with histopathological proven cervical cancer (FIGO IB1−IVA) for the diagnostic accuracy of standard MRI and standard MRI with diffusion-weighted imaging with background body signal suppression (DWIBS) for the correct pre-therapeutic assessment of the definite FIGO category. (3) Results: In 7 out of 32 readings (22%), DWIBS improved diagnostic accuracy. With DWIBS, four (13%) additional readings were assigned the correct major (I−IV) FIGO stages pre-therapeutically. Interobserver reliability of DWIBS was weakest for parametrial infiltration (k = 0.43; CI-95% 0.00−1.00) and perfect for tumor size <2 cm, infiltration of the vaginal lower third, infiltration of adjacent organs and loco-regional nodal metastases (k = 1.000; CI-95% 1.00−1.00). (4) Conclusions: the pre-therapeutic staging of cervical cancer has a high diagnostic accuracy and interobserver reliability when using standard MRI but can be further optimized with the addition of DWIBS sequences when reporting is performed by an experienced radiologist.


Subject(s)
Uterine Cervical Neoplasms , Humans , Female , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/therapy , Reproducibility of Results , Retrospective Studies , Feasibility Studies , Whole Body Imaging/methods , Sensitivity and Specificity
7.
Diagnostics (Basel) ; 12(12)2022 Dec 16.
Article in English | MEDLINE | ID: mdl-36553207

ABSTRACT

(1) Background: Early-stage glottic cancer is easily missed on magnetic resonance imaging (MRI). Diffusion-weighted imaging (DWI) may improve diagnostic accuracy. Therefore, our aim was to assess the value of adding diffusion-weighted imaging with background body signal suppression (DWIBS) to pre-therapeutic MRI staging. (2) Methods: Two radiologists with 8 and 13 years of experience, blinded to each other's findings, initially interpreted only standard MRI, later DWIBS alone, and afterward, standard MRI + DWIBS in 41 patients with histopathologically proven pT1a laryngeal cancer of the glottis. (3) Results: Detectability rates with standard MRI, DWIBS only, and standard MRI + DWIBS were 68-71%, 63-66%, and 73-76%, respectively. Moreover, interobserver reliability was calculated as good (κ = 0.712), very good (κ = 0.84), and good (κ = 0.69) for standard MRI, DWIBS only, and standard MRI + DWIBS, respectively. (4) Conclusions: Standard MRI, DWIBS alone, and standard MRI + DWIBS showed an encouraging detection rate, as well as distinct interobserver reliability in the diagnosis of early-stage laryngeal cancer when compared to the definitive histopathologic report.

8.
Tomography ; 8(5): 2522-2532, 2022 10 09.
Article in English | MEDLINE | ID: mdl-36287809

ABSTRACT

(1) Background: To determine the importance of diffusion-weighted whole-body MRI with background body signal suppression (DWIBS) in the staging process of patients with suspected head and neck carcinomas. (2) Methods: A total of 30 patients (24 male, 6 female) with a median age of 67 years with clinically suspected head and neck carcinoma with pathologic cervical nodal swelling in ultrasound underwent the staging procedure with computed tomography (CT) and whole-body MRI including DWIBS. (3) Results: In a total of 9 patients, abnormalities in the routine work-up of pretherapeutic staging were found. Five cases of either secondary cancer or distant metastases were only visible in DWIBS, while being missed on CT. One diagnosis was only detectable in CT and not in DWIBS, whereas three diagnoses were recognizable in both modalities. (4) Conclusions: DWIBS in addition to a standard neck MRI in cervical lymphadenopathy suspicious for head and neck cancer yielded additional clinically relevant diagnoses in 17% of cases that would have been missed by current staging routine procedures. DWIBS offered a negative predictive value of 98.78% for ruling out distant metastases or secondary malignancies.


Subject(s)
Head and Neck Neoplasms , Whole Body Imaging , Humans , Male , Female , Aged , Whole Body Imaging/methods , Fluorodeoxyglucose F18 , Multimodal Imaging/methods , Sensitivity and Specificity , Head and Neck Neoplasms/diagnostic imaging
9.
Tomography ; 9(1): 50-59, 2022 12 26.
Article in English | MEDLINE | ID: mdl-36648992

ABSTRACT

BACKGROUND: Microwave ablation (MWA) has gained relevance in the treatment of hepatic malignancies and especially in hepatocellular carcinoma (HCC), and it is an important alternative to surgery. The purpose of the study was to evaluate whether the minimal ablative margin (MAM) or the initial tumor size has a greater effect on the success of stereotactic MWA of HCC regarding the time to local tumor progression (LTP) and overall survival (OS). METHODS: 88 patients, who received stereotactic MWA of 127 tumor lesions with a curative intention were included in this single-center, retrospective study. The MAM was evaluated in a side-by-side comparison of pre- and post-ablative, contrast-enhanced slice imaging. A Cox proportional hazard model with a frailty term was computed to assess the influence of the MAM and the maximum tumor diameter on the time to LTP and the OS. RESULTS: The maximum tumor diameter was identified as a significant positive predictor for LTP (hazard ratio 1.04, 95% CI 1.00-1.08, p = 0.03), but it was not a significant positive predictor for the OS (p = 0.20). The MAM did not have a significant influence on LTP-free survival (p = 0.23) and OS (p = 0.67). CONCLUSION: For the successful stereotactic MWA of HCC, the MAM and maximum tumor diameter might not have an influence on the OS, but the maximum tumor diameter seems to be an independent predictor of the time to LTP.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Humans , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/surgery , Carcinoma, Hepatocellular/pathology , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/surgery , Liver Neoplasms/pathology , Retrospective Studies , Microwaves/therapeutic use , Treatment Outcome
10.
Rofo ; 193(12): 1451-1460, 2021 Dec.
Article in English, German | MEDLINE | ID: mdl-34348402

ABSTRACT

PURPOSE: Evaluation of the diagnostic accuracy of a checklist-style structured reporting template in the setting of whole-body multislice computed tomography in major trauma patients depending on the level of experience of the reporting radiologist. MATERIALS AND METHODS: A total of 140 major trauma scans with the same protocol were included in this retrospective study. In a purely trial-intended reading, the trauma scans were analyzed by three radiologists with different levels of experience (resident, radiologist with 3 years of experience after board certification, and radiologist with 7 years of experience after board certification). The aim was to fill in the checklist 1 template within one minute to immediately diagnose management-altering findings. Checklist 2 was intended for the analysis of important trauma-related findings within 10 minutes. Reading times were documented. The final radiology report and the documented injuries in the patient's medical record were used as gold standard. RESULTS: The evaluation of checklist 1 showed a range of false-negative reports between 5.0 % and 11.4 % with the resident showing the highest accuracy. Checklist 2 showed overall high diagnostic inaccuracy (19.3-35.0 %). The resident's diagnostic accuracy was statistically significantly higher compared to the radiologist with 3 years of experience after board certification (p = 0.0197) and with 7 years of experience after board certification (p = 0.0046). Shorter average reporting time resulted in higher diagnostic inaccuracy. Most of the missed diagnoses were fractures of the spine and ribs. CONCLUSION: By using a structured reporting template in the setting of major trauma computed tomography, less experienced radiologists reach a higher diagnostic accuracy compared to experienced readers. KEY POINTS: · In the setting of a pure trial reading, the diagnostic inaccuracy of template-based reporting of major trauma CT examinations is high.. · Fractures in general and especially of the vertebral bodies and ribs were the most commonly missed diagnoses.. · In a study setting, less experienced radiologists seem to reach a higher diagnostic accuracy when using a structured reporting approach.. CITATION FORMAT: · Dendl LM, Pausch AM, Hoffstetter P et al. Structured Reporting of Whole-Body Trauma CT Scans Using Checklists: Diagnostic Accuracy of Reporting Radiologists Depending on Their Level of Experience. Fortschr Röntgenstr 2021; 193: 1451 - 1460.


Subject(s)
Checklist , Radiologists , Humans , Retrospective Studies , Tomography, X-Ray Computed , Whole Body Imaging
12.
Ther Clin Risk Manag ; 14: 173-178, 2018.
Article in English | MEDLINE | ID: mdl-29416344

ABSTRACT

PURPOSE: The aim of this study was to evaluate the true incidence of cervical artery dissections (CeADs) in trauma patients with an Injury Severity Score (ISS) of ≥16, since head-and-neck computed tomography angiogram (CTA) is not a compulsory component of whole-body trauma computed tomography (CT) protocols. PATIENTS AND METHODS: A total of 230 consecutive trauma patients with an ISS of ≥16 admitted to our Level I trauma center during a 24-month period were prospectively included. Standardized whole-body CT in a 256-detector row scanner included a head-and-neck CTA. Incidence, mortality, patient and trauma characteristics, and concomitant injuries were recorded and analyzed retrospectively in patients with carotid artery dissection (CAD) and vertebral artery dissection (VAD). RESULTS: Of the 230 patients included, 6.5% had a CeAD, 5.2% had a CAD, and 1.7% had a VAD. One patient had both CAD and VAD. For both, CAD and VAD, mortality is 25%. One death was caused by fatal cerebral ischemia due to high-grade CAD. A total of 41.6% of the patients with traumatic CAD and 25% of the patients with VAD had neurological sequelae. CONCLUSION: Mandatory head-and-neck CTA yields higher CeAD incidence than reported before. We highly recommend the compulsory inclusion of a head-and-neck CTA to whole-body CT routines for severely injured patients.

13.
Acta Radiol ; 59(3): 275-279, 2018 Mar.
Article in English | MEDLINE | ID: mdl-28565961

ABSTRACT

Background In severely injured trauma patients, non-penetrating aortic arch injuries (NAAI) have a remarkable incidence and mortality. Both diagnostics and therapy of NAAI recently underwent significant changes. Purpose To assess mortality, morbidity, and the risk factors associated with NAAI in severely injured patients (Injury Severity Score [ISS] ≥16) under the light of recent technical and procedural advances in trauma care. Material and Methods A total of 230 consecutive trauma patients with ISS ≥16 admitted to our level-I trauma center during a 24-month period, were prospectively included and underwent standardized whole-body computed tomography (CT) in a 2 × 128-detector-row scanner. Incidence, mortality, patient and trauma characteristics, and concomitant injuries were recorded for patients with NAAI. Localization of NAAI was described referring to Mitchell and Ishimaru; severity was graded according to the proposal of Heneghan et al. Results Thirteen of 230 patients had a NAAI, yielding an incidence of 5.6%. Mean age and ISS was not elevated in NAAI (44.4 ± 14.8 years, ISS = 38 ± 12.4). Mortality was 23.1%. One patient had severe neurologic sequelae from a stroke; all surviving patients had to undergo (transient) anticoagulant therapy. Trauma mechanism was of high kinetic energy in all cases. Concomitant injuries were predominantly thoracic (rib fractures = 76.9%, thoracic spine fracture = 38.5%). Conclusion Whenever an individual possibly encountered a deceleration-acceleration trauma mechanism, a high level of suspicion for NAAI should be maintained. It remains to be determined whether recent advances in mortality are due to changes in trauma care or due to improved vehicle and road safety.


Subject(s)
Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/injuries , Tomography, X-Ray Computed , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Female , Humans , Injury Severity Score , Male , Middle Aged , Prospective Studies , Risk Factors , Trauma Severity Indices , Young Adult
14.
PLoS One ; 12(6): e0180066, 2017.
Article in English | MEDLINE | ID: mdl-28644901

ABSTRACT

PURPOSE: To assess biomechanical factors in aortic arch geometry contributing to the development of non-penetrating aortic arch injury (NAAI) in multiply injured patients with an Injury Severity Score (ISS) ≥ 16. MATERIAL AND METHODS: 230 consecutive multiply injured trauma patients with an ISS ≥ 16 admitted to our Level-I trauma center during a consecutive 24-month period were prospectively included of whom 13 presented with NAAI (5.7%). Standardized whole-body CT in a 2x128-detector-row scanner included a head-and-neck CTA. Aortic arch diameters, width, height, angles and thoracic width and height were measured in individuals with NAAI and ISS-, sex-, age-, and trauma mechanism-matched controls. RESULTS: There was no difference between groups regarding sex, age, ISS, and aortic diameters. The aortic arch angle in individuals with NAAI (71.3° ± 14.9°) was larger than in healthy control (60.7° ± 8.6°; p*<0.05). In patients with NAAI, the distance between ascendent and descendent aorta was larger (5.2 cm ± 1.9 cm) than in control (2.8 ± 0.5 cm; ***p<0.001). The aortic arch is higher above tracheal bifurcation in NAAI (3.6 cm ± 0.6 cm) than in matched control (2.4 cm ± 0.3 cm; ***p<0.001). Accordingly, the area under the aortic arch, calculated as half of an eliptic shape, is significantly larger in patients with NAAI (15.0 cm2 ± 6.5 cm2) when compared to age- and sex-matched controls without NAAI (5.5 cm2 ± 1.3 cm2; ***p<0.001). CONCLUSION: Besides the magnitude of deceleration and direction of impact, width and height of the aortic arch are the 3rd and 4th factor directly contributing to the risk of developing traumatic NAAI in severely injured patients.


Subject(s)
Aorta/diagnostic imaging , Aorta/injuries , Adult , Age Factors , Aged , Computed Tomography Angiography , Female , Humans , Injury Severity Score , Male , Middle Aged , Organ Size , Prospective Studies , Risk Factors , Sex Factors , Whole Body Imaging , Young Adult
15.
Rofo ; 189(3): 239-246, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28249311

ABSTRACT

Purpose Evaluation of clinical impact regarding diagnostic and therapeutic changes influenced by interdisciplinary radiological case presentations. Materials and Methods Prospective evaluation of radiological-gastrointestinal clinical case conferences over a 1-year period at a tertiary care center. We documented the preparation (phase 1) and clinical case conference (phase 2) regarding their impact on the radiology report and further diagnostic work-up and therapy. Results 1067 examinations were evaluated in 69 clinical case conferences including 487 cases. We calculated a mean time of 35.8 minutes per conference with 5.1 minutes per case for preparation. During phase 1, major changes compared to the previous report were found in 1.2 % of cases, and no change was found in 91.4 % of cases. In phase 2 an additional relevant finding was found in 0.6 % of cases, while there was no major change to the reports in 99 % of cases. We recommended further radiological diagnostic workup in 9 % of cases and interventional radiological examination in 2.7 % of cases, while no change was documented in 83.2 %. Further radiological or surgical therapy was recommended in 7 % and 6.8 % of cases, respectively. There was no change in therapy in 78.5 % of cases. Conclusion The analysis of an interdisciplinary radiological case presentation in internal medicine shows that the case discussion with the radiologist results in a change in patient management in 37.3 % of cases (16.8 % diagnosis, 21.5 % therapy). Overall, interdisciplinary radiological clinical case conferences help to improve the management and quality of patient care. Our data support the broad implementation of radiological clinical case conferences. Key Points · The second opinion obtained during the preparation of a radiological case presentation does not change the written report in most cases.. · "Talking radiology" in radiological case presentations results in a significant change in patient management in over ⅓ of all cases.. · In radiological clinical case conferences an experienced radiologist can initiate diagnostic and interventional radiological methods that can be correctly implemented in therapeutic pathways.. · "Talking radiology" improves the quality of therapy and patient care.. Citation Format · Dendl L. M., Teufel A., Schleder S. et al. Analysis of Radiological Case Presentations and their Impact on Therapy and Treatment Concepts in Internal Medicine. Fortschr Röntgenstr 2017; 189: 239 - 246.


Subject(s)
Critical Pathways/standards , Diagnostic Imaging/standards , Gastrointestinal Diseases/diagnostic imaging , Gastrointestinal Diseases/therapy , Interdisciplinary Communication , Internal Medicine/standards , Adolescent , Adult , Aged , Aged, 80 and over , Clinical Decision-Making , Diagnostic Imaging/statistics & numerical data , Female , Gastrointestinal Diseases/epidemiology , Germany/epidemiology , Humans , Male , Middle Aged , Prevalence , Quality Indicators, Health Care/standards , Risk Assessment , Treatment Outcome , Young Adult
16.
Eur Arch Otorhinolaryngol ; 272(2): 479-83, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25115315

ABSTRACT

The objective of this study was to determine the effect of orbital decompression procedures on the intraocular pressure (IOP). The orbital compartment syndrome represents an emergency situation. Due to the elevated IOP vision loss may ensue. Several maneuvers including lateral canthotomy are discussed to reduce the IOP. Eight orbits were studied in a fresh frozen cadaveric model (4 specimens). Intraorbital volume was determined by CT volumetry. An orbital compartment syndrome was simulated by injecting viscous material into the orbit. Injected volumes were documented and lateral canthotomy, cantholysis, inferior and superior septolysis were performed. IOP and exophthalmometric measurements were obtained after each intervention. Controlled elevation of IOP was achieved in all specimens. IOP was partially reduced after performing a lateral canthotomy in eight orbits. IOP was significantly and sufficiently decreased under 20 mmHg by inferior cantholysis in seven orbits. An additional superior cantholysis was necessary in two orbits to achieve a complete decompression. Inferior or superior septolysis were not needed to further reduce the IOP. Lateral canthotomy must be followed by an inferior cantholysis to successfully decompress an orbital compartment syndrome in the majority of cases. Occasionally, superior cantholysis may generate additional benefit. Additional inferior and superior septolysis were not shown to provide a beneficial effect when performed after canthotomy and cantholysis.


Subject(s)
Compartment Syndromes/surgery , Decompression, Surgical/methods , Eyelids/surgery , Intraocular Pressure , Ophthalmologic Surgical Procedures/methods , Orbit/surgery , Cadaver , Compartment Syndromes/physiopathology , Female , Humans , Male , Tomography, Spiral Computed
17.
Cardiovasc Intervent Radiol ; 38(1): 60-4, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24599522

ABSTRACT

PURPOSE: This study was designed to evaluate the technical success and the early clinical outcome of patients undergoing percutaneous aspiration thrombectomy (PAT) for the treatment of arterial thromboembolism following percutaneous infrainguinal transluminal angioplasty (PTA). METHODS: In this single-center study, during a period of 7 years retrospectively, 47 patients (22 male, 47 %) with a mean age of 73 (range 53-96) years were identified in whom PAT was performed for the treatment of thromboembolic complications of infrainguinal PTA. Primary technical success was defined as residual stenosis of <50 % in diameter after sole PAT, whereas secondary technical success was defined as residual stenosis of <50 % in diameter after PAT and additional PTA and/or stenting. Clinical outcome parameters (e.g., need for further intervention, minor/major amputation) were evaluated for the 30-day postinterventional period. RESULTS: Primary technical success was achieved in 64 % of patients (30/47); secondary technical success was obtained in 96 % of patients (45/47). Clinical outcome data were available in 38 patients. In 87 % of patients (33/38), there was no need for further intervention within the 30-day postinterventional period. In three patients, minor amputations were conducted due to preexisting ulcerations (Rutherford Category 5 respectively). CONCLUSIONS: PAT enables endovascular treatment of iatrogenic thromboembolic complications after PTA with good technical and early clinical results and minimal morbidity.


Subject(s)
Angioplasty/adverse effects , Thrombectomy/methods , Thromboembolism/etiology , Thromboembolism/surgery , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Suction , Treatment Outcome
18.
PLoS One ; 9(8): e104706, 2014.
Article in English | MEDLINE | ID: mdl-25116048

ABSTRACT

BACKGROUND: Markers that predict the occurrence of a complicated disease behavior in patients with Crohn's disease (CD) can permit a more aggressive therapeutic regimen for patients at risk. The aim of this cohort study was to test the blood levels of hemoglobin (Hgb) and hematocrit (Hct) for the prediction of complicated CD behavior and CD related surgery in an adult patient population. METHODS: Blood samples of 62 CD patients of the German Inflammatory Bowel Disease-network "Kompetenznetz CED" were tested for the levels of Hgb and Hct prior to the occurrence of complicated disease behavior or CD related surgery. The relation of these markers and clinical events was studied using Kaplan-Meier survival analysis and adjusted COX-proportional hazard regression models. RESULTS: The median follow-up time was 55.8 months. Of the 62 CD patients without any previous complication or surgery 34% developed a complication and/or underwent CD related surgery. Low Hgb or Hct levels were independent predictors of a shorter time to occurrence of the first complication or CD related surgery. This was true for early as well as late occurring complications. Stable low Hgb or Hct during serial follow-up measurements had a higher frequency of complications compared to patients with a stable normal Hgb or Hct, respectively. CONCLUSIONS: Determination of Hgb or Hct in complication and surgery naïve CD patients might serve as an additional tool for the prediction of complicated disease behavior.


Subject(s)
Biomarkers/blood , Crohn Disease/pathology , Disease Progression , Hematocrit , Hemoglobins/analysis , Adult , Cohort Studies , Crohn Disease/diagnosis , Crohn Disease/surgery , Erythrocytes , Female , Humans , Male , Proportional Hazards Models , Treatment Outcome
19.
Inflamm Bowel Dis ; 19(5): 983-90, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23474779

ABSTRACT

BACKGROUND: Magnetic resonance imaging (MRI) of the bowel is an increasingly used modality to evaluate patients with Crohn's disease. The Montreal classification of the disease behavior is considered as an excellent prognostic and therapeutic parameter for these patients. In our study, we correlated the behavior assessment performed by a radiologist based on MRI with the surgeons' clinical assessment based on the assessment during abdominal surgery. METHODS: We evaluated 76 patients with Crohn's disease, who underwent bowel resection and had an MRI within 4 weeks before surgery. Radiological behavior assessment was performed by 2 radiologists based on MRI. Behavior was classified into B1 (nonstricturing and nonpenetrating), B2, and B3 (penetrating) disease. Surgical assessment was done by the same surgeon, who performed all bowel resections, based on intraoperative findings and histologic results. RESULTS: The surgical assessment identified 4 patients (5%) as B1, 16 patients (21%) as B2, and 56 patients (74%) as B3. In 97% (n = 74) of all patients, the intraoperative and radiological assessment were identical with interobserver agreement of 0.937. In one case, B2 was radiological considered as B1, and in another case, B3 was diagnosed as B2. The diagnosis of a stricture had the highest sensitivity of 96%, whereas the detection of inflammatory mass showed the lowest sensitivity of 81%. Abscesses had the lowest positive predictive value of 68% with a specificity of 88%. Best correlation was found for fistulae (0.895). CONCLUSIONS: MRI represents an excellent imaging modality to correctly assess the Montreal classification-based disease behavior in patients scheduled for bowel resection with Crohn's disease.


Subject(s)
Crohn Disease/diagnostic imaging , Inflammation/diagnostic imaging , Intestines/diagnostic imaging , Magnetic Resonance Imaging , Postoperative Complications , Adolescent , Adult , Aged , Anastomosis, Surgical , Crohn Disease/pathology , Crohn Disease/surgery , Female , Follow-Up Studies , Humans , Image Processing, Computer-Assisted , Inflammation/etiology , Intestines/pathology , Intestines/surgery , Male , Middle Aged , Prognosis , Prospective Studies , Radiography , Tertiary Care Centers , Young Adult
20.
Emerg Med J ; 30(3): e20, 2013 Mar.
Article in English | MEDLINE | ID: mdl-22518057

ABSTRACT

BACKGROUND: Technological progress has led to the introduction of hand-carried ultrasound (HCU) imagers in clinical workflow. The aim of this study is to analyse whether examination with a HCU device is a rapid and reliable alternative to contrast-enhanced multidetector CT (MDCT) scans in diagnosis of free intra-abdominal fluid and organ lacerations in major trauma patients. METHODS: 31 major trauma patients with an injury severity score >15 and the necessity of a MDCT scan (standard of reference) were enrolled prospectively to this study, and additionally examined with a HCU, according to 'focused assessment with sonography for trauma' principles for the assessment of organ lacerations and free intra-abdominal fluid. The HCU device employed was of the latest generation. Statistical analysis was performed using PASW V.18. RESULTS: Four patients were diagnosed with free intra-abdominal fluid (prevalence 12.9%). HCU showed a sensitivity and specificity of 75% and 100%, respectively. Positive predictive value and negative predictive value were 100% and 96%, respectively. Five patients had organ lacerations (prevalence 16.1%). In these cases, the HCU was able to detect organ lacerations with a sensitivity and specificity of 80% and 100%, respectively. Therefore, a positive predictive value and negative predictive value of 100% and 96%, respectively, were calculated. CONCLUSION: In major trauma patients, examination with HCU according to the 'focused assessment with sonography for trauma' principles for the diagnosis of organ lacerations and free intra-abdominal fluid is a reliable and rapid alternative to MDCT scans and can help save precious time in emergency situations, and should, additionally, be evaluated in the pre-clinical workflow.


Subject(s)
Abdominal Injuries/diagnostic imaging , Lacerations/diagnostic imaging , Pericardial Effusion/diagnostic imaging , Point-of-Care Systems , Ultrasonography/instrumentation , Adolescent , Adult , Aged , Aged, 80 and over , Contrast Media , Equipment Design , Humans , Injury Severity Score , Iohexol/analogs & derivatives , Middle Aged , Predictive Value of Tests , Prospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...