Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
JACC Cardiovasc Interv ; 12(5): 484-493, 2019 03 11.
Article in English | MEDLINE | ID: mdl-30846089

ABSTRACT

OBJECTIVES: This study evaluated the 12-month safety and effectiveness of a paclitaxel drug-coated balloon for treatment of intermittent claudication or rest pain in subjects with femoropopliteal chronic total occlusions (CTO). BACKGROUND: CTOs are difficult to treat, and the optimal intervention remains to be determined. METHODS: The IN.PACT Global Study is an international single-arm study that enrolled 1,535 patients with symptomatic femoropopliteal artery disease. The study contains prospectively defined cohorts with prospectively planned imaging analyses, including a CTO (≥5 cm) cohort in which subjects underwent duplex ultrasonography analyzed by an independent core laboratory. The primary safety endpoint was a composite of freedom from device- and procedure-related mortality through 30 days, and freedom from major target limb amputation and target vessel revascularization through 12 months. An independent Clinical Events Committee adjudicated all adverse events. The primary effectiveness endpoint was primary patency at 12 months, defined as freedom from clinically driven target lesion revascularization and freedom from restenosis. RESULTS: The CTO imaging cohort had 126 subjects with 127 lesions (mean lesion length 22.83 ± 9.76 cm). Primary patency by Kaplan-Meier estimate was 85.3% through 12 months. Provisional stenting was performed in 46.8% of lesions. The primary safety composite endpoint was achieved by 88.7% of subjects. There were no device- or procedure-related deaths through 30 days or major target limb amputations through 12 months. CONCLUSIONS: The paclitaxel drug-coated balloon was safe and highly effective at 12 months after treatment of subjects with CTO ≥5 cm in the femoropopliteal arteries. (IN.PACT Global Clinical Study; NCT01609296).


Subject(s)
Angioplasty, Balloon/instrumentation , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Femoral Artery , Paclitaxel/administration & dosage , Peripheral Arterial Disease/therapy , Popliteal Artery , Vascular Access Devices , Aged , Amputation, Surgical , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/mortality , Cardiovascular Agents/adverse effects , Chronic Disease , Constriction, Pathologic , Equipment Design , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Limb Salvage , Male , Middle Aged , Paclitaxel/adverse effects , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/mortality , Peripheral Arterial Disease/physiopathology , Popliteal Artery/diagnostic imaging , Popliteal Artery/physiopathology , Progression-Free Survival , Prospective Studies , Recurrence , Risk Assessment , Risk Factors , Time Factors , Vascular Patency
2.
Circ Cardiovasc Interv ; 12(1): e007730, 2019 01.
Article in English | MEDLINE | ID: mdl-30630355
3.
Circ Cardiovasc Interv ; 11(10): e005654, 2018 10.
Article in English | MEDLINE | ID: mdl-30354636

ABSTRACT

Background The IN.PACT Global Study was an international prospective single-arm clinical trial to evaluate the safety and effectiveness of a drug-coated balloon in the treatment of atherosclerotic disease of the superficial femoral and/or popliteal arteries (P1-P3) in subjects with intermittent claudication and/or rest pain. Prespecified subjects were selected for core-laboratory-adjudicated duplex ultrasound imaging, including a subcohort with long lesions (≥15 cm). Methods and Results Subjects were followed for 12 months. The primary safety end point was a composite of freedom from device- and procedure-related mortality through 30 days and freedom from major target limb amputation and clinically-driven target vessel revascularization through 12 months. An independent Clinical Events Committee adjudicated all adverse events. The primary effectiveness end point was primary patency at 12 months (by duplex ultrasound). The long lesion imaging cohort had 157 subjects (164 lesions). Mean lesion length was 26.40±8.61 cm. Provisional stents were implanted in 39.4% (63/160) of lesions. Primary patency by Kaplan-Meier estimate was 91.1%, and freedom from clinically-driven target lesion revascularization was 94.2% at 12 months. The primary safety composite end point was achieved by 94.0% (126/134) of subjects. There were no device- or procedure-related deaths or major target limb amputations. Conclusions The IN.PACT Admiral drug-coated balloon was safe and highly effective at 12 months after treatment in a rigorous independently adjudicated analysis of real-world subjects with lesions ≥15 cm in the superficial femoral and/or popliteal arteries (P1-P3). CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov . Unique identifier: NCT01609296.


Subject(s)
Angioplasty, Balloon/instrumentation , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Femoral Artery , Paclitaxel/administration & dosage , Peripheral Arterial Disease/therapy , Popliteal Artery , Vascular Access Devices , Aged , Aged, 80 and over , Amputation, Surgical , Angioplasty, Balloon/adverse effects , Cardiovascular Agents/adverse effects , Equipment Design , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Limb Salvage , Male , Middle Aged , Paclitaxel/adverse effects , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Popliteal Artery/diagnostic imaging , Popliteal Artery/physiopathology , Prospective Studies , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Ultrasonography, Doppler, Duplex
4.
JACC Cardiovasc Interv ; 10(20): 2113-2123, 2017 10 23.
Article in English | MEDLINE | ID: mdl-29050631

ABSTRACT

OBJECTIVES: This study sought to evaluate the safety and effectiveness of a paclitaxel-coated drug-coated balloon (DCB) for the treatment of patients with de novo in-stent restenosis (ISR). BACKGROUND: Treatment of patients with ISR remains a challenge. Current strategies are plagued by high rates of recurrent restenosis and need for reintervention. The best intervention for ISR remains to be elucidated. METHODS: The IN.PACT Global study is an independently adjudicated multicenter, prospective, single-arm study that enrolled 1,535 subjects with symptomatic atherosclerotic disease of the superficial femoral and/or popliteal arteries, including de novo ISR lesions. Patients enrolled in the pre-specified ISR imaging cohort were evaluated for vessel patency and reintervention within the 12-month follow-up period. RESULTS: A total of 131 subjects with 149 ISR lesions were included for analysis. The mean age of the cohort was 67.8 years. Mean lesion length was 17.17 ± 10.47 cm, including 34.0% total occlusions and 59.1% calcified lesions. The 12-month Kaplan-Meier estimate of primary patency was 88.7%. The rate of clinically driven target lesion revascularization (CD TLR) at 12 months was 7.3%. The primary safety outcome, a composite of freedom from device- and procedure-related mortality through 30 days and freedom from major target limb amputation and CD TLR within 12 months, was 92.7%. There were no major target limb amputations, no deaths, and a low (0.8%) thrombosis rate. CONCLUSIONS: Results from the ISR imaging cohort demonstrate high patency and a low rate of CD TLR at 12 months. These data confirm the safety and effectiveness of the IN.PACT Admiral DCB (Medtronic, Dublin, Ireland) in complex femoropopliteal lesions, including this challenging subset.


Subject(s)
Angioplasty, Balloon/instrumentation , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Endovascular Procedures/instrumentation , Femoral Artery , Paclitaxel/administration & dosage , Peripheral Arterial Disease/therapy , Popliteal Artery , Stents , Vascular Access Devices , Aged , Amputation, Surgical , Angiography , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/mortality , Cardiovascular Agents/adverse effects , Constriction, Pathologic , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Kaplan-Meier Estimate , Limb Salvage , Male , Middle Aged , Paclitaxel/adverse effects , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/mortality , Peripheral Arterial Disease/physiopathology , Popliteal Artery/diagnostic imaging , Popliteal Artery/physiopathology , Prospective Studies , Recurrence , Time Factors , Treatment Outcome , Ultrasonography, Doppler, Duplex , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL