Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Ecol Evol ; 11(10): 5584-5597, 2021 May.
Article in English | MEDLINE | ID: mdl-34026031

ABSTRACT

Blue Catfish Ictalurus furcatus are an invasive, yet economically important species in the Chesapeake Bay. However, their impact on the trophic ecology of this system is not well understood. In order to provide in-depth analysis of predation by Blue Catfish, we identified prey items using high-throughput DNA sequencing (HTS) of entire gastrointestinal tracts from 134 samples using two genetic markers, mitochondrial cytochrome c oxidase I (COI) and the nuclear 18S ribosomal RNA gene. We compared our HTS results to a more traditional "hybrid" approach that coupled morphological identification with DNA barcoding. The hybrid study was conducted on additional Blue Catfish samples (n = 617 stomachs) collected from the same location and season in the previous year. Taxonomic representation with HTS vastly surpassed that achieved with the hybrid methodology in Blue Catfish. Significantly, our HTS study identified several instances of at-risk and invasive species consumption not identified using the hybrid method, supporting the hypothesis that previous studies using morphological methods may greatly underestimate consumption of critical species. Finally, we report the novel finding that Blue Catfish diet diversity inversely correlates to daily flow rates, perhaps due to higher mobility and prey-seeking behaviors exhibited during lower flow.

2.
Astron J ; 153(No 4)2017 Apr.
Article in English | MEDLINE | ID: mdl-29375142

ABSTRACT

The vast majority of the 4700 confirmed planets and planet candidates discovered by the Kepler space telescope were first found by the Kepler pipeline. In the pipeline, after a transit signal is found, all data points associated with those transits are removed, creating a "Swiss cheese"-like light curve full of holes, which is then used for subsequent transit searches. These holes could render an additional planet undetectable (or "lost"). We examine a sample of 114 stars with 3+ confirmed planets to see the effect that this "Swiss cheesing" may have. A simulation determined that the probability that a transiting planet is lost due to the transit masking is low, but non-neglible, reaching a plateau at ~3.3% lost in the period range of P = 400 - 500 days. We then model the transits in all quarters of each star and subtract out the transit signals, restoring the in-transit data points, and use the Kepler pipeline to search the transit-subtracted (i.e., transit-cleaned) light curves. However, the pipeline did not discover any credible new transit signals. This demonstrates the validity and robustness of the Kepler pipeline's choice to use transit masking over transit subtraction. However, a follow-up visual search through all the transit-subtracted data, which allows for easier visual identification of new transits, revealed the existence of a new, Neptune-sized exoplanet. Kepler-150 f (P = 637.2 days, RP = 3.86 R⊕) is confirmed using a combination of false positive probability analysis, transit duration analysis, and the planet multiplicity argument.

3.
EuroIntervention ; 8(10): 1172-81, 2013 Feb 22.
Article in English | MEDLINE | ID: mdl-23425542

ABSTRACT

AIMS: Frequency-domain optical coherence tomography (FD-OCT) provides a rapid tomographic scan of a coronary vessel, with an accurate reconstruction of its lumen profile. An FD-OCT-based metric that corresponds more closely with physiological significance of lesions may enable more precise guidance of interventional procedures. The aim of this feasibility study was to evaluate a new method for quantifying coronary lesion severity that estimates hyperaemic flow resistance of branched vessel segments imaged by FD-OCT. METHODS AND RESULTS: An analytical flow model was developed that relates fractional flow reserve (FFR) to the vascular resistance ratio (VRR), a measure of blood flow resistance derived from volumetric FD-OCT lumen profiles. The VRR-FFR relationship was evaluated in 21 patients on whom both pressure measurement and FD-OCT imaging were performed in a random order during maximal hyperaemia. Lesion severity assessed by VRR showed a stronger linear correlation with FFR measurements (before model optimisation [blinded]: r=0.81; p<0.001; root mean square error [RMSE]=0.095 FFR units; after model optimisation [unblinded]: r=0.91; p<0.001; RMSE=0.066 FFR units) than quantitative coronary angiography and FD-OCT-derived measurements of minimum lumen area (r=0.67; p=0.0012) and per cent area stenosis (r=-0.61; p=0.004). CONCLUSIONS: Accurate volumetric measurement of the lumen profile with FD-OCT correlates more closely with FFR than standard metrics derived from single image cross-sections. VRR shows promise as a method for evaluating lesion severity.


Subject(s)
Coronary Vessels/pathology , Fractional Flow Reserve, Myocardial , Tomography, Optical Coherence , Aged , Female , Humans , Male , Middle Aged , Severity of Illness Index , Vascular Resistance
4.
Biomed Opt Express ; 3(10): 2647-57, 2012 Oct 01.
Article in English | MEDLINE | ID: mdl-23082303

ABSTRACT

We present a 1300 nm Fourier domain mode locked (FDML) laser for optical coherence tomography (OCT) that combines both, a high 1.6 MHz wavelength sweep rate and an ultra-long instantaneous coherence length for rapid volumetric deep field imaging. By reducing the dispersion in the fiber delay line of the FDML laser, the instantaneous coherence length and hence the available imaging range is approximately quadrupled compared to previously published MHz-FDML setups, the imaging speed is increased by a factor of 16 compared to previous extended coherence length results. We present a detailed characterization of the FDML laser performance. We demonstrate for the first time MHz-OCT imaging of the anterior segment of the human eye. The OCT system provides enough imaging depth to cover the whole range from the top surface of the cornea down to the crystalline lens.

5.
Gastroenterol Res Pract ; 2012: 684832, 2012.
Article in English | MEDLINE | ID: mdl-22844274

ABSTRACT

Two main nonsurgical endoscopic approaches for ablating dysplastic and early cancer lesions in the esophagus have gained popularity, namely, radiofrequency ablation (RFA) and cryospray ablation (CSA). We report a uniquely suited endoscopic and near-microscopic imaging modality, three-dimensional (3D) optical coherence tomography (OCT), to assess and compare the esophagus immediately after RFA and CSA. The maximum depths of architectural changes were measured and compared between the two treatment groups. RFA was observed to induce 230~260 µm depth of architectural changes after each set of ablations over a particular region, while CSA was observed to induce edema-like spongiform changes to ~640 µm depth within the ablated field. The ability to obtain micron-scale depth-resolved images of tissue structural changes following different ablation therapies makes 3D-OCT an ideal tool to assess treatment efficacy. Such information could be potentially used to provide real-time feedback for treatment dosing and to identify regions that need further retreatment.

6.
Gastrointest Endosc ; 76(6): 1104-12, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22831857

ABSTRACT

BACKGROUND: Radiofrequency ablation (RFA) is effective for treating Barrett's esophagus (BE) but often involves multiple endoscopy sessions over several months to achieve complete response. OBJECTIVE: Identify structural markers that correlate with treatment response by using 3-dimensional (3-D) optical coherence tomography (OCT; 3-D OCT). DESIGN: Cross-sectional. SETTING: Single teaching hospital. PATIENTS: Thirty-three patients, 32 male and 1 female, with short-segment (<3 cm) BE undergoing RFA treatment. INTERVENTION: Patients were treated with focal RFA, and 3-D OCT was performed at the gastroesophageal junction before and immediately after the RFA treatment. Patients were re-examined with standard endoscopy 6 to 8 weeks later and had biopsies to rule out BE if not visibly evident. MAIN OUTCOME MEASUREMENTS: The thickness of BE epithelium before RFA and the presence of residual gland-like structures immediately after RFA were determined by using 3-D OCT. The presence of BE at follow-up was assessed endoscopically. RESULTS: BE mucosa was significantly thinner in patients who achieved complete eradication of intestinal metaplasia than in patients who did not achieve complete eradication of intestinal metaplasia at follow-up (257 ± 60 µm vs 403 ± 86 µm; P < .0001). A threshold thickness of 333 µm derived from receiver operating characteristic curves corresponded to a 92.3% sensitivity, 85% specificity, and 87.9% accuracy in predicting the presence of BE at follow-up. The presence of OCT-visible glands immediately after RFA also correlated with the presence of residual BE at follow-up (83.3% sensitivity, 95% specificity, 90.6% accuracy). LIMITATIONS: Single center, cross-sectional study in which only patients with short-segment BE were examined. CONCLUSION: Three-dimensional OCT assessment of BE thickness and residual glands during RFA sessions correlated with treatment response. Three-dimensional OCT may predict responses to RFA or aid in making real-time RFA retreatment decisions in the future.


Subject(s)
Barrett Esophagus/surgery , Catheter Ablation , Esophagoscopy , Esophagus/pathology , Tomography, Optical Coherence/methods , Adult , Aged , Aged, 80 and over , Barrett Esophagus/pathology , Cross-Sectional Studies , Esophagus/surgery , Female , Follow-Up Studies , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Sensitivity and Specificity , Treatment Outcome
7.
World J Gastroenterol ; 18(20): 2502-10, 2012 May 28.
Article in English | MEDLINE | ID: mdl-22654447

ABSTRACT

AIM: To demonstrate the feasibility of optical coherence tomography (OCT) imaging in differentiating cervical inlet patch (CIP) from normal esophagus, Barrett's esophagus (BE), normal stomach and duodenum. METHODS: This study was conducted at the Veterans Affairs Boston Healthcare System (VABHS). Patients undergoing standard esophagogastroduodenoscopy at VABHS, including one patient with CIP, one representative patient with BE and three representative normal subjects were included. White light video endoscopy was performed and endoscopic 3D-OCT images were obtained in each patient using a prototype OCT system. The OCT imaging probe passes through the working channel of the endoscope to enable simultaneous video endoscopy and 3D-OCT examination of the human gastrointestinal (GI) tract. Standard hematoxylin and eosin (H and E) histology was performed on biopsy or endoscopic mucosal resection specimens in order to compare and validate the 3D-OCT data. RESULTS: CIP was observed from a 68-year old male with gastroesophageal reflux disease. The CIP region appeared as a pink circular lesion in the upper esophagus under white light endoscopy. OCT imaging over the CIP region showed columnar epithelium structure, which clearly contrasted the squamous epithelium structure from adjacent normal esophagus. 3D-OCT images obtained from other representative patients demonstrated distinctive patterns of the normal esophagus, BE, normal stomach, and normal duodenum bulb. Microstructures, such as squamous epithelium, lamina propria, muscularis mucosa, muscularis propria, esophageal glands, Barrett's glands, gastric mucosa, gastric glands, and intestinal mucosal villi were clearly observed with OCT and matched with H and E histology. These results demonstrated the feasibility of using OCT to evaluate GI tissue morphology in situ and in real-time. CONCLUSION: We demonstrate in situ evaluation of CIP microstructures using 3D-OCT, which may be a useful tool for future diagnosis and follow-up of patients with CIP.


Subject(s)
Esophageal Diseases/pathology , Tomography, Optical Coherence , Aged , Barrett Esophagus/pathology , Duodenum/anatomy & histology , Endoscopy, Digestive System , Esophagus/anatomy & histology , Humans , Male , Stomach/anatomy & histology
8.
Gastrointest Endosc ; 76(1): 32-40, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22482920

ABSTRACT

BACKGROUND: Radiofrequency ablation (RFA) is an endoscopic technique used to eradicate Barrett's esophagus (BE). However, such ablation can commonly lead to neosquamous epithelium overlying residual BE glands not visible by conventional endoscopy and may evade detection on random biopsy samples. OBJECTIVE: To demonstrate the capability of endoscopic 3-dimensional optical coherence tomography (3D-OCT) for the identification and characterization of buried glands before and after RFA therapy. DESIGN: Cross-sectional study. SETTING: Single teaching hospital. PATIENTS: Twenty-six male and 1 female white patients with BE undergoing RFA treatment. INTERVENTIONS: 3D-OCT was performed at the gastroesophageal junction in 18 patients before attaining complete eradication of intestinal metaplasia (pre-CE-IM group) and in 16 patients after CE-IM (post-CE-IM group). MAIN OUTCOME MEASUREMENTS: Prevalence, size, and location of buried glands relative to the squamocolumnar junction. RESULTS: 3D-OCT provided an approximately 30 to 60 times larger field of view compared with jumbo and standard biopsy and sufficient imaging depth for detecting buried glands. Based on 3D-OCT results, buried glands were found in 72% of patients (13/18) in the pre-CE-IM group and 63% of patients (10/16) in the post-CE-IM group. The number (mean [standard deviation]) of buried glands per patient in the post-CE-IM group (7.1 [9.3]) was significantly lower compared with the pre-CE-IM group (34.4 [44.6]; P = .02). The buried gland size (P = .69) and distribution (P = .54) were not significantly different before and after CE-IM. LIMITATIONS: A single-center, cross-sectional study comparing patients at different time points in treatment. Lack of 1-to-1 coregistered histology for all OCT data sets obtained in vivo. CONCLUSION: Buried glands were frequently detected with 3D-OCT near the gastroesophageal junction before and after radiofrequency ablation.


Subject(s)
Barrett Esophagus/pathology , Esophagogastric Junction/pathology , Tomography, Optical Coherence , Adult , Aged , Aged, 80 and over , Barrett Esophagus/surgery , Catheter Ablation , Cross-Sectional Studies , Esophagoscopy , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged
9.
Int J Cardiovasc Imaging ; 28(8): 1879-86, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22422037

ABSTRACT

The neointimal tissue characteristics inside sirolimus-eluting stent (SES) were evaluated by optical coherence tomography (OCT) according to follow-up duration. One hundred and thirty-three Optical coherence tomography was performed in 96 patients with 143 SES which were retrospectively included and divided into 2 groups according to follow-up duration: Group 1, <24 months (98 stents in 71 patients); Group 2, >24 months (35 stents in 25 patients). The neointimal tissue coverage pattern and characteristics were studied using a new OCT analysis system which can quantitatively analyze tissue property by measuring attenuation, backscatter and signal intensity in the region of interest. Using these parameters, a multivariable logistic regression model was constructed to divide neointima into homogenous or heterogeneous type. We defined homogeneous nointima as neointimal tissue having uniform optical properties and does not showing focal variations in backscattering pattern and heterogeneous neointima as neointimal tissue with focally changing optical properties and showing various backscattering patterns. The average time between stent implantation and follow-up OCT imaging was 1.2 years in Group 1 and 3.2 years in Group 2. The number of neointima covered cross-sections, neointimal thickness, and neointimal area increased significantly with the length of follow-up duration after SES implantation (P < 0.01). The incidence of heterogeneous neointima was higher in Group 2 than in Group 1 (P < 0.01). Heterogeneous neointima was associated with higher incidence of microvessels (P = 0.0023) and lipid rich plaque (P = 0.0015) compared with homogeneous neointima. The neointimal tissue characteristics may change over time after SES implantation. The incidence of heterogeneous pattern was higher in the SES group with longer follow-up duration. Microvessels and lipid rich plaques were more frequently observed in neointima with heterogeneous pattern. Neointimal heterogeneity could be an important factor for the late stability of SES.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Coronary Vessels/pathology , Drug-Eluting Stents , Neointima , Percutaneous Coronary Intervention/instrumentation , Sirolimus/administration & dosage , Tomography, Optical Coherence , Aged , Chi-Square Distribution , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Female , Humans , Image Interpretation, Computer-Assisted , Logistic Models , Male , Microvessels/pathology , Middle Aged , Multivariate Analysis , Odds Ratio , Percutaneous Coronary Intervention/adverse effects , Plaque, Atherosclerotic , Predictive Value of Tests , Prosthesis Design , Retrospective Studies , Software , Time Factors , Treatment Outcome
11.
Opt Express ; 19(21): 20930-9, 2011 Oct 10.
Article in English | MEDLINE | ID: mdl-21997102

ABSTRACT

Fourier domain mode locked (FDML) lasers are excellent tunable laser sources for frequency domain optical coherence tomography (FD-OCT) systems due to their combination of high sweep rates, large tuning ranges, and high output powers. However, conventional FDML lasers provide coherence lengths of only 4-10 mm, limiting their use in demanding applications such as intravascular OCT where coherence lengths of >20 mm are required for optimal imaging of large blood vessels. Furthermore, like most swept lasers, conventional FDML lasers produce only one useable sweep direction per tunable filter drive cycle, halving the effective sweep rate of the laser compared to the filter drive frequency. Here, we demonstrate a new class of FDML laser incorporating broadband dispersion compensation near 1310 nm. Elimination of chromatic dispersion in the FDML cavity results in the generation of forward (short to long wavelength) and backward (long to short wavelength) sweeps with substantially identical properties and coherence lengths of >21 mm. This advance enables long-range, high-speed FD-OCT imaging without the need for optical buffering stages, significantly reducing laser cost and complexity.


Subject(s)
Fourier Analysis , Optics and Photonics/methods , Tomography, Optical Coherence/methods , Algorithms , Biotechnology/methods , Diagnostic Imaging/methods , Equipment Design , Lasers , Models, Statistical , Optical Fibers , Semiconductors , Tomography, Optical Coherence/instrumentation
12.
Phys Med Biol ; 56(20): 6665-75, 2011 Oct 21.
Article in English | MEDLINE | ID: mdl-21946129

ABSTRACT

To assist cardiologists investigating neointimal tissue growth on stents during follow-up with optical coherence tomography (OCT), we developed an automatic algorithm to locate deeply buried stent struts and to quantify the restenosis burden. The technique is based on an improved steerable filter for computing the local ridge strength and orientation. It also uses an ellipsoid fitting algorithm and continuity criteria to obtain globally optimal stent localization. The restenosis burden calculations were compared to manual assessment of OCT coronary artery image data obtained from in vivo human clinical studies. Compared to manual assessment by expert readers, the algorithm operated with > 97% accuracy in the measurement of mean and maximum restenosis burden. The results indicated that the technique yielded comparable accuracy in measuring restenosis burden, and significantly reduced user interaction time.


Subject(s)
Arteries/pathology , Neointima/diagnosis , Neointima/etiology , Stents/adverse effects , Tomography, Optical Coherence/methods , Algorithms , Automation , Follow-Up Studies , Graft Occlusion, Vascular/complications , Humans , Image Processing, Computer-Assisted , Neointima/complications , Neointima/pathology , Software
13.
J Biomed Opt ; 15(6): 061711, 2010.
Article in English | MEDLINE | ID: mdl-21198159

ABSTRACT

Coronary calcified plaque (CP) is both an important marker of atherosclerosis and major determinant of the success of coronary stenting. Intracoronary optical coherence tomography (OCT) with high spatial resolution can provide detailed volumetric characterization of CP. We present a semiautomatic method for segmentation and quantification of CP in OCT images. Following segmentation of the lumen, guide wire, and arterial wall, the CP was localized by edge detection and traced using a combined intensity and gradient-based level-set model. From the segmentation regions, quantification of the depth, area, angle fill fraction, and thickness of the CP was demonstrated. Validation by comparing the automatic results to expert manual segmentation of 106 in vivo images from eight patients showed an accuracy of 78±9%. For a variety of CP measurements, the bias was insignificant (except for depth measurement) and the agreement was adequate when the CP has a clear outer border and no guide-wire overlap. These results suggest that the proposed method can be used for automated CP analysis in OCT, thereby facilitating our understanding of coronary artery calcification in the process of atherosclerosis and helping guide complex interventional strategies in coronary arteries with superficial calcification.


Subject(s)
Algorithms , Calcinosis/pathology , Coronary Artery Disease/pathology , Focal Adhesions/pathology , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Pattern Recognition, Automated/methods , Tomography, Optical Coherence/methods , Humans , Reproducibility of Results , Sensitivity and Specificity
14.
EuroIntervention ; 4(4): 529-33, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19284077

ABSTRACT

Optical coherence tomography (OCT) has become a key intracoronary imaging modality able to traverse some of the limitations of angiography and intravascular ultrasound. In vivo imaging with high resolution (around 15 micrometres) has given unique insights into not only atherosclerotic plaque, but also to the understanding of tissue responses underlying stent implantation. Novel developments with faster OCT pullback speeds will further simplify the procedural requirements and eventually eliminate the need for proximal vessel balloon occlusion during image acquisition. This report explores the current and future developments in OCT technology that will see this unique imaging modality become a key player in both the clinical and research arena for the interventional cardiologist.


Subject(s)
Coronary Artery Disease/diagnosis , Coronary Vessels/pathology , Tomography, Optical Coherence , Angioplasty, Balloon, Coronary , Animals , Coronary Artery Disease/therapy , Equipment Design , Fourier Analysis , Humans , Models, Animal , Predictive Value of Tests , Tomography, Optical Coherence/instrumentation , Treatment Outcome
15.
Therap Adv Gastroenterol ; 2(3): 149-156, 2009 Jan 01.
Article in English | MEDLINE | ID: mdl-20593010

ABSTRACT

Endoscopic argon plasma coagulation and bipolar electrocautery are currently preferred treatments for chronic radiation proctitis, but ulcerations and strictures frequently occur. Radiofrequency ablation (RFA) has been successful for mucosal ablation in the esophagus. Here we report the efficacy of RFA with the BarRx Halo(90) system in three patients with bleeding from chronic radiation proctitis. In all cases, the procedure was well tolerated and hemostasis was achieved after 1 or 2 RFA sessions. Re-epithelialization of squamous mucosa was observed over areas of prior hemorrhage. No stricturing or ulceration was seen on follow-up up to 19 months after RFA treatment. Real-time endoscopic optical coherence tomography (EOCT) visualized epithelialization and subsurface tissue microvasculature pre- and post-treatment, demonstrating its potential for follow-up assessment of endoscopic therapies.

16.
J Biomed Opt ; 13(3): 034003, 2008.
Article in English | MEDLINE | ID: mdl-18601548

ABSTRACT

Intravascular optical coherence tomography (OCT) has been proven a powerful diagnostic tool for cardiovascular diseases. However, the optical mechanism for the qualitative observations are still absent. We address the fundamental issues that underlie the tissue characterization of OCT images obtained from coronary arteries. For this, we investigate both the attenuation and the backscattering properties of different plaque components of postmortem human cadaver coronary arteries. The artery samples are examined both from lumen surface using a catheter and from transversely cut surface using an OCT microscope, where OCT images could be matched to histology exactly. Light backscattering coefficient microb and attenuation coefficients microt are determined for three basic plaque types based on a single-scattering physical model: calcification (microb=4.9+/-1.5 mm(-1), microt=5.7+/-1.4 mm(-1)), fibers (microb=18.4+/-6.4 mm(-1), microt=6.4+/-1.2 mm(-1)), and lipid pool (microb=28.1+/-8.9 mm(-1), microt=13.7+/-4.5 mm(-1)). Our results not only explain the origins of many qualitative OCT features, but also show that combination of backscattering and attenuation coefficient measurements can be used for contrast enhancing and better tissue characterization.


Subject(s)
Algorithms , Coronary Artery Disease/pathology , Image Interpretation, Computer-Assisted/methods , Photometry/methods , Tomography, Optical Coherence/methods , Humans , Image Enhancement/methods , Light , Reproducibility of Results , Scattering, Radiation , Sensitivity and Specificity
17.
Opt Express ; 16(4): 2469-85, 2008 Feb 18.
Article in English | MEDLINE | ID: mdl-18542326

ABSTRACT

Optical coherence tomography (OCT) is an emerging medical imaging technology which generates high resolution, cross-sectional images in situ, without the need for excisional biopsy. Previous clinical studies using endoscopic OCT with standard 10-15 microm axial resolution have demonstrated its capability in diagnosing Barrett's esophagus (BE) and high-grade dysplasia (HGD). Quantitative OCT image analysis has shown promise for detecting HGD in Barrett's esophagus patients. We recently developed an endoscopic OCT system with an improved axial resolution of approximately 5 microm. The goal in this manuscript is to compare standard resolution OCT and ultrahigh resolution OCT (UHR-OCT) for image quality and computer-aided detection using normal and Barrett's esophagus. OCT images of gastrointestinal (GI) tissues were obtained using UHR-OCT (5.5 microm) and standard resolution OCT (13 microm). Image quality including the speckle size and sharpness was compared. Texture features of endoscopic OCT images from normal and Barrett's esophagus were extracted using quantitative metrics including spatial frequency analysis and statistical texture analysis. These features were analyzed using principal component analysis (PCA) to reduce the vector dimension and increase the discriminative power, followed by linear discrimination analysis (LDA). UHR-OCT images of GI tissues improved visualization of fine architectural features compared to standard resolution OCT. In addition, the quantitative image feature analysis showed enhanced discrimination of normal and Barrett's esophagus with UHR-OCT. The ability of UHR-OCT to resolve tissue morphology at improved resolution enables visualization of subtle features in OCT images, which may be useful in disease diagnosis. Enhanced classification of image features using UHR-OCT promises to help in the computer-aided diagnosis of GI diseases.


Subject(s)
Barrett Esophagus/pathology , Esophagus , Tomography, Optical Coherence/methods , Esophagoscopy , Esophagus/pathology , Humans , Image Processing, Computer-Assisted
18.
J Biomed Opt ; 12(5): 051704, 2007.
Article in English | MEDLINE | ID: mdl-17994877

ABSTRACT

Recent advances in catheter-based optical coherence tomography (OCT) have provided the necessary resolution and acquisition speed for high-quality intravascular imaging. Complications associated with clearing blood from the vessel of a living patient have prevented its wider acceptance. We identify a surgical application that takes advantage of the vascular imaging powers of OCT but that circumvents the difficulties. Coronary artery bypass grafting (CABG) is the most commonly performed major surgery in America. A critical determinant of its outcome has been postulated to be injury to the conduit vessel incurred during the harvesting procedure or pathology preexistent in the harvested vessel. As a test of feasibility, intravascular OCT imaging is obtained from the radial arteries (RAs) and/or saphenous veins (SVs) of 35 patients scheduled for CABG. Pathologies detected by OCT are compared to registered histological sections obtained from discarded segments of each graft. OCT reliably detects atherosclerotic lesions in the RAs and discerns plaque morphology as fibrous, fibrocalcific, or fibroatheromatous. OCT is also used to assess intimal trauma and residual thrombi related to endoscopic harvest and the quality of the distal anastomosis. We demonstrate the feasibility of OCT imaging as an intraoperative tool to select conduit vessels for CABG.


Subject(s)
Coronary Artery Bypass/methods , Coronary Artery Disease/pathology , Coronary Artery Disease/surgery , Coronary Vessels/pathology , Coronary Vessels/surgery , Surgery, Computer-Assisted/methods , Tomography, Optical Coherence/methods , Female , Humans , Male
19.
J Biomed Opt ; 12(3): 034008, 2007.
Article in English | MEDLINE | ID: mdl-17614716

ABSTRACT

Optical coherence tomography (OCT) is an emerging medical imaging technology that enables high-resolution, noninvasive, cross-sectional imaging of microstructure in biological tissues in situ and in real time. When combined with small-diameter catheters or needle probes, OCT offers a practical tool for the minimally invasive imaging of living tissue morphology. We evaluate the ability of OCT to image normal kidneys and discriminate pathological changes in kidney structure. Both control and experimental preserved rat kidneys were examined ex vivo by using a high-resolution OCT imaging system equipped with a laser light source at 1.3-microm wavelength. This system has a resolution of 3.3 microm (depth) by 6 microm (transverse). OCT imaging produced cross-sectional and en face images that revealed the sizes and shapes of the uriniferous tubules and renal corpuscles. OCT data revealed significant changes in the uriniferous tubules of kidneys preserved following an ischemic or toxic (i.e., mercuric chloride) insult. OCT data was also rendered to produce informative three-dimensional (3-D) images of uriniferous tubules and renal corpuscles. The foregoing observations suggest that OCT can be a useful non-excisional, real-time modality for imaging pathological changes in donor kidney morphology prior to transplantation.


Subject(s)
Algorithms , Image Enhancement/methods , Imaging, Three-Dimensional/methods , Ischemia/pathology , Kidney/blood supply , Kidney/pathology , Tomography, Optical Coherence/methods , Animals , Image Interpretation, Computer-Assisted/methods , Male , Rats , Rats, Wistar , Reproducibility of Results , Sensitivity and Specificity
20.
Dermatol Surg ; 33(4): 421-5; discussion 425-6, 2007 Apr.
Article in English | MEDLINE | ID: mdl-17430375

ABSTRACT

BACKGROUND: Optical coherence tomography uses advanced photonics and fiber optics to obtain high-resolution cross-sectional images and tissue characterization in real time. OBJECTIVE: The objective was to correlate measurements of the depth of basal cell carcinomas obtained by optical coherence tomography and standard histopathologic examinations. METHODS: Twenty previously scanned optical coherence tomography images of histopathologically confirmed basal cell carcinoma were reviewed. A computer-generated depth scale was used to measure the depth of the neoplasm. These measurements were compared with direct measurements of tumor thickness of analogous tissue specimens made with a microscope micrometer. RESULTS: All 20 sites demonstrated excellent correlation of tissue thickness, to a depth of about 1 mm, estimated by optical coherence tomography or routine histopathologic tests. This depth correlation was consistent across several different types of basal cell carcinoma observed. CONCLUSION: Optical coherence tomography, compared with routine histopathologic techniques, shows promise as a method for estimating the superficial thickness of basal cell carcinoma.


Subject(s)
Carcinoma, Basal Cell/pathology , Skin Neoplasms/pathology , Tomography, Optical Coherence , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...