Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Earth Space Chem ; 8(7): 1281-1295, 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39045227

ABSTRACT

Organic molecules are ubiquitous in primitive solar system bodies such as comets and asteroids. These primordial organic compounds may have formed in the interstellar medium and in protoplanetary disks (PPDs) before being accreted and further transformed in the parent bodies of meteorites, icy moons, and dwarf planets. The present study describes the composition of primordial organics analogs produced in a laboratory simulator of the PPD (the Nebulotron experiment at the CRPG laboratory) with nitrogen contents varying from N/C < 0.01 to N/C = 0.63. We present the first Fourier transform ion cyclotron resonance mass spectrometry analysis of these analogs. Several thousands of molecules with masses between m/z 100 and 500 are characterized. The mass spectra show a Gaussian shape with maxima around m/z 250. Highly condensed polyaromatic hydrocarbons (PAH) are the most common compounds identified in the samples with lower nitrogen contents. As the amount of nitrogen increases, a dramatic increase of the chemical diversity is observed. Nitrogen-bearing compounds are also dominated by polyaromatic hydrocarbons (PANH) made of 5- and 6-membered rings containing up to four nitrogen atoms, including triazine and pyrazole rings. Such N-rich aromatic species are expected to decompose easily in the presence of water at higher temperatures. Pure carbon molecules are also observed for samples with relatively small fractions of nitrogen. MS peaks compatible with the presence of amino acids and nucleobases, or their isomers, are detected. When comparing these Nebulotron samples with the insoluble fraction of the Paris meteorite organic matter, we observe that the samples with intermediate N/C ratios bracketing that of the Paris insoluble organic matter (IOM) display relative proportions of the CH, CHO, CHN, and CHNO chemical families also bracketing those of the Paris IOM. Our results support that Nebulotron samples are relevant laboratory analogs of primitive chondritic organic matter.

2.
Biochim Biophys Acta Mol Cell Biol Lipids ; 1869(7): 159539, 2024 Jul 26.
Article in English | MEDLINE | ID: mdl-39067686

ABSTRACT

Persister cells constitute a bacterial subpopulation able to survive to high concentrations of antibiotics. This phenotype is temporary and reversible, and thus could be involved in the recurrence of infections and emergence of antibiotic resistance. To better understand how persister cells survive to such high antibiotic concentration, we examined changes in their lipid composition. We thus compared the lipidome of Acinetobacter baumannii ATCC 19606T persister cells formed under ciprofloxacin treatment with the lipidome of control cells grown without antibiotic. Using matrix assisted laser desorption ionisation-Fourier transform ion cyclotron resonance mass spectrometry, we observed a higher abundance of short chains and secondary chains without hydroxylation for lipid A in persister cells. Using liquid chromatography-tandem mass spectrometry, we found that persister cells produced particular phosphatidylglycerols, as LPAGPE and PAGPE, but also lipids with particular acyl chains containing additional hydroxyl group or uncommon di-unsaturation on C18 and C16 acyl chains. In order to determine the impact of these multiple lipidome modifications on membrane fluidity, fluorescence anisotropy assays were performed. They showed an increase of rigidity for the membrane of persister cells, inducing likely a decrease membrane permeability to protect cells during dormancy. Finally, we highlighted that A. baumannii persister cells also produced particular wax esters, composed of two fatty acids and a fatty diol. These uncommon storage lipids are key metabolites allowing a rapid bacterial regrow when antibiotic pressure disappears. These overall changes in persister lipidome may constitute new therapeutic targets to combat these particular dormant cells.

3.
J Mol Neurosci ; 74(2): 44, 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38630337

ABSTRACT

Plants are a valuable source of information for pharmacological research and new drug discovery. The present study aimed to evaluate the neuroprotective potential of the leaves of the medicinal plant Sterculia setigera. In vitro, the effect of Sterculia setigera leaves dry hydroethanolic extract (SSE) was tested on cultured cerebellar granule neurons (CGN) survival when exposed to hydrogen peroxide (H2O2) or 6-hydroxydopamine (6-OHDA), using the viability probe fluorescein diacetate (FDA), a lactate dehydrogenase (LDH) activity assay, an immunocytochemical staining against Gap 43, and the quantification of the expression of genes involved in apoptosis, necrosis, or oxidative stress. In vivo, the effect of intraperitoneal (ip) injection of SSE was assessed on the developing brain of 8-day-old Wistar rats exposed to ethanol neurotoxicity by measuring caspase-3 activity on cerebellum homogenates, the expression of some genes in tissue extracts, the thickness of cerebellar cortical layers and motor coordination. In vitro, SSE protected CGN against H2O2 and 6-OHDA-induced cell death at a dose of 10 µg/mL, inhibited the expression of genes Casp3 and Bad, and upregulated the expression of Cat and Gpx7. In vivo, SSE significantly blocked the deleterious effect of ethanol by reducing the activity of caspase-3, inhibiting the expression of Bax and Tp53, preventing the reduction of the thickness of the internal granule cell layer of the cerebellar cortex, and restoring motor functions. Sterculia setigera exerts neuroactive functions as claimed by traditional medicine and should be a good candidate for the development of a neuroprotective treatment against neurodegenerative diseases.


Subject(s)
Cell Death , Ethanol , Neurons , Neuroprotective Agents , Plant Extracts , Plant Leaves , Sterculia , Animals , Rats , Caspase 3/metabolism , Ethanol/administration & dosage , Ethanol/chemistry , Ethanol/toxicity , Hydrogen Peroxide/toxicity , Neuroprotective Agents/administration & dosage , Neuroprotective Agents/chemistry , Neuroprotective Agents/pharmacology , Oxidopamine/toxicity , Rats, Wistar , Sterculia/chemistry , Plant Leaves/chemistry , Plants, Medicinal/chemistry , Neurons/cytology , Neurons/drug effects , Neurons/enzymology , Neurons/pathology , Lactate Dehydrogenases/metabolism , GAP-43 Protein/analysis , Apoptosis/genetics , Oxidative Stress/genetics , Cerebellum/cytology , Cerebellum/drug effects , Cerebellum/pathology , Cerebellum/physiology , Male , Female , Cells, Cultured , Cell Death/drug effects , Gene Expression Regulation/drug effects , Phytochemicals/administration & dosage , Phytochemicals/analysis , Phytochemicals/chemistry , Phytochemicals/pharmacology , Plant Extracts/administration & dosage , Plant Extracts/chemistry , Plant Extracts/pharmacology , Antioxidants/analysis , Antioxidants/chemistry , Antioxidants/pharmacology , Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry , Liquid Chromatography-Mass Spectrometry , Secondary Metabolism
4.
Anal Chim Acta ; 1304: 342535, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38637036

ABSTRACT

The implementation of ion mobility spectrometry (IMS) in liquid chromatography-high-resolution mass spectrometry (LC-HRMS) workflows has become a valuable tool for improving compound annotation in metabolomics analyses by increasing peak capacity and by adding a new molecular descriptor, the collision cross section (CCS). Although some studies reported high repeatability and reproducibility of CCS determination and only few studies reported good interplatform agreement for small molecules, standardized protocols are still missing due to the lack of reference CCS values and reference materials. We present a comparison of CCS values of approximatively one hundred lipid species either commercially available or extracted from human plasma. We used three different commercial ion mobility technologies from different laboratories, drift tube IMS (DTIMS), travelling wave IMS (TWIMS) and trapped IMS (TIMS), to evaluate both instrument repeatability and interlaboratory reproducibility. We showed that CCS discrepancies of 0.3% (average) could occur depending on the data processing software tools. Moreover, eleven CCS calibrants were evaluated yielding mean RSD below 2% for eight calibrants, ESI Low concentration tuning mix (Tune Mix) showing the lowest RSD (< 0.5%) in both ion modes. Tune Mix calibrated CCS from the three different IMS instruments proved to be well correlated and highly reproducible (R2 > 0.995 and mean RSD ≤ 1%). More than 90% of the lipid CCS had deviations of less than 1%, demonstrating high comparability between techniques, and the possibility to use the CCS as molecular descriptor. We highlighted the need of standardized procedures for calibration, data acquisition, and data processing. This work demonstrates that using harmonized analytical conditions are required for interplatform reproducibility for CCS determination of human plasma lipids.


Subject(s)
Lipids , Metabolomics , Humans , Reproducibility of Results
5.
J Am Soc Mass Spectrom ; 35(4): 696-704, 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38430122

ABSTRACT

Collision cross section (CCS) values determined in ion mobility-mass spectrometry (IM-MS) are increasingly employed as additional descriptors in metabolomics studies. CCS values must therefore be reproducible and the causes of deviations must be carefully known and controlled. Here, we analyzed lipid standards by trapped ion mobility spectrometry-mass spectrometry (TIMS-MS) to evaluate the effects of solvent and flow rate in flow injection analysis (FIA), as well as electrospray source parameters including nebulizer gas pressure, drying gas flow rate, and temperature, on the ion mobility and CCS values. The stability of ion mobility experiments was studied over 10 h, which established the need for a delay-time of 20 min to stabilize source parameters (mostly pressure and temperature). Modifications of electrospray source parameters induced shifts of ion mobility peaks and even the occurrence of an additional peak in the ion mobility spectra. This behavior could be essentially explained by ion-solvent cluster formation. Changes in source parameters were also found to impact CCS value measurements, resulting in deviations up to 0.8%. However, internal calibration with the Tune Mix calibrant reduced the CCS deviations to 0.1%. Thus, optimization of source parameters is essential to achieve a good desolvation of lipid ions and avoid misinterpretation of peaks in ion mobility spectra due to solvent effects. This work highlights the importance of internal calibration to ensure interoperable CCS values, usable in metabolomics annotation.

6.
Molecules ; 28(5)2023 Feb 22.
Article in English | MEDLINE | ID: mdl-36903305

ABSTRACT

Pharmaceutical analysis refers to an area of analytical chemistry that deals with active compounds either by themselves (drug substance) or when formulated with excipients (drug product). In a less simplistic way, it can be defined as a complex science involving various disciplines, e.g., drug development, pharmacokinetics, drug metabolism, tissue distribution studies, and environmental contamination analyses. As such, the pharmaceutical analysis covers drug development to its impact on health and the environment. Moreover, due to the need for safe and effective medications, the pharmaceutical industry is one of the most heavily regulated sectors of the global economy. For this reason, powerful analytical instrumentation and efficient methods are required. In the last decades, mass spectrometry has been increasingly used in pharmaceutical analysis both for research aims and routine quality controls. Among different instrumental setups, ultra-high-resolution mass spectrometry with Fourier transform instruments, i.e., Fourier transform ion cyclotron resonance (FTICR) and Orbitrap, gives access to valuable molecular information for pharmaceutical analysis. In fact, thanks to their high resolving power, mass accuracy, and dynamic range, reliable molecular formula assignments or trace analysis in complex mixtures can be obtained. This review summarizes the principles of the two main types of Fourier transform mass spectrometers, and it highlights applications, developments, and future perspectives in pharmaceutical analysis.


Subject(s)
Drug Development , Excipients , Mass Spectrometry/methods , Excipients/chemistry , Fourier Analysis
7.
J AOAC Int ; 85(2): 375-83, 2002.
Article in English | MEDLINE | ID: mdl-11990022

ABSTRACT

As part of a project funded by the European Commission (EC) for the development and evaluation of multiresidue methods for analysis of drinking and related waters, 17 European laboratories evaluated a method using styrene-divinylbenzene copolymer solid-phase extraction followed by liquid chromatography with diode array detection. The main aim of the study was to evaluate whether the method meets the requirements of EC Drinking Water Directive 98/83 in terms of accuracy, precision, and detection limit for 21 pesticides according to the following requirements: limit of detection, < or =0.025 microg/L; accuracy expressed as recovery, between 75 and 125%; and precision expressed as repeatability relative standard deviation of the method, <12.5%, and as reproducibility relative standard deviation of the method, <25%. Analyses for unknown concentrations were performed with commercial bottled and tap waters. All laboratories were able to achieve detection limits of 0.01 microg/L for all pesticides except pirimicarb (0.02 microg/L). The criteria for repeatability were met for all compounds. Terbutryn in bottled water and carbendazim in tap water did not meet the criteria for reproducibility. In terms of accuracy, the method met the requirements for all pesticides in both matrixes, except for metamitron. However, several compounds (linuron, terbutryn, propazine, metobromuron, and isoproturon) showed recoveries slightly below 75%.


Subject(s)
Pesticide Residues/analysis , Water Supply/analysis , Water/analysis , Chromatography, Liquid , Ultraviolet Rays
SELECTION OF CITATIONS
SEARCH DETAIL