Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
Article in English | MEDLINE | ID: mdl-39219464

ABSTRACT

BACKGROUND: Modified balloon (MB) treatment in severely calcified coronary artery lesions is an established technique. However, some lesions require Rotablation (RA) as bailout strategy. AIMS: This study aimed to assess predictors of switch from MB to RA and its impact on procedural and midterm outcomes. METHODS: Four hundred and eighty-three consecutive patients were included undergoing MB treatment (n = 204) with a scoring or cutting balloon, or upfront RA treatment (n = 279) serving as control cohort. Strategy switch from MB to RA was performed in 19 of 204 patients. Procedural success was defined as successful stent implantation and TIMI III flow. RESULTS: In the MB cohort, median age was 72 [63-78] years, 75.5% were male and 42.1% had acute coronary syndrome. Procedure success was achieved in 89.4% of the switch group versus 98.4% of the MB only group (p < 0.001) and in 96.4% of the RA cohort. In the switch group, periprocedural complications (31.6% vs. 8.1% vs. 11.8%, p = 0.007), radiation dose (149 [126-252] vs. 59 [30-97] vs. 102 [59-156] Gcm2; p < 0.001) and contrast volume (250 [190-250] vs. 190 [150-250] vs. 195 [190--250] mL; p < 0.001) were significantly higher. Diabetes (OR 3.8, 95% CI 1.1-13.9, p = 0.042), chronic kidney disease stage 4 or 5 (OR 19.0, 95% CI 3.3-108.6, p < 0.001) and pronounced calcification resulting in higher angiographic diameter stenosis (OR 1.13, 95% CI 1.1-1.2, p = 0.001) independently predicted strategy switch. Midterm results were not affected by strategy switch regarding 1-year target lesion revascularization rates (86% vs. 89% vs. 89%; log-rank p = 0.95). CONCLUSION: Primary RA strategy might be considered in patients with severely calcified coronary artery lesions with high angiographic diameter stenosis, diabetes or impaired renal function due to increased periprocedural complication rates, radiation dose, and contrast volume following strategy switch.

2.
J Clin Med ; 13(8)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38673445

ABSTRACT

(1) Objective: We aimed to assess whether the candidate profile, the long-term outcomes and the predictors for long-term mortality after transcatheter edge-to-edge mitral valve repair (M-TEER) have changed over the last decade; (2) Methods: Long-term follow-up data (median time of 1202 days) including mortality, MACCE and functional status were available for 677 consecutive patients enrolled in the prospective MiTra Ulm registry from January 2010 to April 2019. The initial 340 patients treated in our institution before January 2016 were compared with the following 337 patients; (3) Results: Patients treated after 2016 showed significantly less ventricular dilatation (left ventricular end-systolic diameter of 43 ± 13 mm vs. 49 ± 16 mm, p < 0.007), lower systolic pulmonary pressures (50 ± 15 mmHg vs. 57 ± 21 mmHg, p = 0.01) and a lower prevalence of severe tricuspid regurgitation (27.2% vs. 47.3%, p < 0.001) at baseline than patients treated before 2016. Compared to the cohort treated before 2016, patients treated afterwards showed a significantly lower all-cause 3-year mortality (29.4% vs. 43.8%, p < 0.001) and lower MACCE (38.6% vs. 54.1%, p < 0.001), without differences for MR etiology. While severe tricuspid regurgitation and NYHA class IV remained independently associated with an increased long-term mortality over the last decade, severe left ventricular dilatation (hazard ratio, HR 2.12, p = 0.047) and severe pulmonary hypertension (HR 2.18, p = 0.047) were predictors of long-term mortality only in patients treated before 2016. (4) Conclusions: The M-TEER candidates are currently treated earlier in the course of disease and benefit significantly in terms of a better long-term survival than patients treated at the beginning of the M-TEER era.

4.
Clin Res Cardiol ; 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38353680

ABSTRACT

BACKGROUND: Transcatheter edge-to-edge mitral valve repair (M-TEER) is often performed in general anesthesia, and postprocedural monitoring is usually warranted on an intensive or intermediate care unit (ICU/IMC). We evaluated the implications of a dedicated valve unit (VU) instead of an ICU/IMC for monitoring after M-TEER. METHODS AND RESULTS: In total, 624 patients were retrospectively analyzed. A total of 312 patients were primarily transferred to either ICU or IMC following M-TEER, and 312 patients were scheduled for the VU in the absence of indications for ICU/IMC treatment. Hospital stay was significantly shorter in VU patients (median 6.0 days (interquartile range (IQR) 5.0 - 8.0) vs. 7.0 days (IQR 6.0 - 10.0), p < 0.001) and their risk for infections (2.9 vs. 7.7%, p = 0.008) and delirium (0.6 vs. 2.6%, p = 0.056) was substantially lower compared to ICU/IMC patients. In-hospital mortality was similar in both groups (0.6% vs. 1.3%, p = 0.41). Fifty patients (16.0%) in the VU group had to cross over to unplanned ICU/IMC admission. The most frequent indication was prolonged need for catecholamines (52.0%). Patients with ICU/IMC crossover had more advanced stages of heart failure (LV-EF < 30% in 36.0 vs. 16.0%, p = 0.001; severe concomitant tricuspid regurgitation in 48.0 vs. 27.8%, p = 0.005) and an LV-EF < 30% was independently associated with unplanned ICU/IMC admission. CONCLUSIONS: Following M-TEER postprocedural monitoring on a VU instead of an ICU/IMC is safe, reduces complications, and spares ICU capacities. Patients with advanced heart failure have a higher risk for unplanned ICU/IMC treatment after M-TEER.

5.
Comput Med Imaging Graph ; 113: 102340, 2024 04.
Article in English | MEDLINE | ID: mdl-38277768

ABSTRACT

Left atrial appendage (LAA) is the source of thrombi formation in more than 90% of strokes in patients with nonvalvular atrial fibrillation. Catheter-based LAA occlusion is being increasingly applied as a treatment strategy to prevent stroke. Anatomical complexity of LAA makes percutaneous occlusion commonly performed under transesophageal echocardiography (TEE) and X-ray (XR) guidance especially challenging. Image fusion techniques integrating 3D anatomical models derived from pre-procedural imaging into the live XR fluoroscopy can be applied to guide each step of the LAA closure. Cardiac magnetic resonance (CMR) imaging gains in importance for radiation-free evaluation of cardiac morphology as alternative to gold-standard TEE or computed tomography angiography (CTA). Manual delineation of cardiac structures from non-contrast enhanced CMR is, however, labor-intensive, tedious, and challenging due to the rather low contrast. Additionally, arrhythmia often impairs the image quality in ECG synchronized acquisitions causing blurring and motion artifacts. Thus, for cardiac segmentation in arrhythmic patients, there is a strong need for an automated image segmentation method. Deep learning-based methods have shown great promise in medical image analysis achieving superior performance in various imaging modalities and different clinical applications. Fully-convolutional neural networks (CNNs), especially U-Net, have become the method of choice for cardiac segmentation. In this paper, we propose an approach for automatic segmentation of cardiac structures from non-contrast enhanced CMR images of arrhythmic patients based on CNNs implemented in a multi-stage pipeline. Two-stage implementation allows subdividing the task into localization of the relevant cardiac structures and segmentation of these structures from the cropped sub-regions obtained from previous step leading to efficient and effective way of automated cardiac segmentation.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Humans , Atrial Appendage/anatomy & histology , Magnetic Resonance Imaging , Atrial Fibrillation/therapy , Tomography, X-Ray Computed , Angiography
6.
Clin Res Cardiol ; 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38270636

ABSTRACT

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is an established treatment for functional mitral regurgitation (FMR) associated with a risk of creating iatrogenic stenosis. OBJECTIVES: To investigate the impact of the P10 and its larger spacer compared to the narrower Ace and its smaller spacer on reduction of mitral valve orifice area (MVOA) during M-TEER. METHODS: Consecutive patients undergoing M-TEER for treatment of severe FMR were screened retrospectively. Patients with a single PASCAL device implantation within the central segments of the MV leaflets, non-complex anatomy, and baseline MVOA ≥ 3.5cm2 were selected. Intraprocedural transesophageal echocardiography was used to compare MVOA reduction with 3D multiplanar reconstruction and direct planimetry. Device selection did not follow a prespecified MVOA threshold. RESULTS: Seventy-two patients (81.0 years, IQR {74.3-85.0}) were included. In 32 patients, the P10 was implanted (44.4%). MR severity (p = 0.66), MR reduction (p = 0.73), and body surface area (p = 0.56) were comparable. Baseline MVOA tended to be smaller in P10 patients with the larger spacer (5.0 ± 1.1 vs. 5.4 ± 1.3cm2, p = 0.18), however, residual MVOA was larger in these patients (2.7 ± 0.7 vs. 2.3 ± 0.6cm2, p = 0.03). Accordingly, relative MVOA reduction was significantly less in P10 patients (- 45.9 ± 7.6 vs. - 56.3 ± 7.0%, p < 0.01). Indirect annuloplasty was more pronounced in Ace patients whereas mean transmitral gradients were similar. CONCLUSION: In FMR patients with non-complex anatomy, the larger spacer of the P10 maintains greater MVOA with similar MR reduction. Hence, the use of the PASCAL Ace device in patients with small MVOAs might correlate with a risk of both clinically relevant orifice reduction and even iatrogenic stenosis.

7.
Int J Comput Assist Radiol Surg ; 19(2): 367-374, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37477817

ABSTRACT

PURPOSE: Image-guided intervention (IGI) systems have the potential to increase the efficiency in interventional cardiology but face limitations from motion. Even though motion compensation approaches have been proposed, the resulting accuracy has rarely been quantified using in vivo data. The purpose of this study is to investigate the potential benefit of motion-compensation in IGS systems. METHODS: Patients scheduled for left atrial appendage closure (LAAc) underwent pre- and postprocedural non-contrast-enhanced cardiac magnetic resonance imaging (CMR). According to the clinical standard, the final position of the occluder device was routinely documented using x-ray fluoroscopy (XR). The accuracy of the IGI system was assessed retrospectively based on the distance of the 3D device marker location derived from the periprocedural XR data and the respective location as identified in the postprocedural CMR data. RESULTS: The assessment of the motion-compensation depending accuracy was possible based on the patient data. With motion synchronization, the measured accuracy of the IGI system resulted similar to the estimated accuracy, with almost negligible distances of the device marker positions identified in CMR and XR. Neglection of the cardiac and/or respiratory phase significantly increased the mean distances, with respiratory motion mainly reducing the accuracy with rather low impact on the precision, whereas cardiac motion decreased the accuracy and the precision of the image guidance. CONCLUSIONS: In the presented work, the accuracy of the IGI system could be assessed based on in vivo data. Motion consideration clearly showed the potential to increase the accuracy in IGI systems. Where the general decrease in accuracy in non-motion-synchronized data did not come unexpected, a clear difference between cardiac and respiratory motion-induced errors was observed for LAAc data. Since sedation and intervention location close to the large vessels likely impacts the respiratory motion contribution, an intervention-specific accuracy analysis may be useful for other interventions.


Subject(s)
Heart , Humans , Retrospective Studies , Motion
8.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Article in English | MEDLINE | ID: mdl-38099912

ABSTRACT

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Predictive Value of Tests , Recovery of Function , Severity of Illness Index , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/physiopathology , Male , Female , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve/physiopathology , Treatment Outcome , Cardiac Catheterization/instrumentation , Cardiac Catheterization/adverse effects , Aged , Risk Factors , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Time Factors , Aged, 80 and over , Heart Valve Prosthesis , Feasibility Studies , Risk Assessment , Prosthesis Design , Echocardiography, Three-Dimensional
9.
JACC Cardiovasc Interv ; 16(23): 2854-2865, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-37999708

ABSTRACT

BACKGROUND: A significant number of patients with severe mitral regurgitation (MR) are not suitable for either surgical or transcatheter edge-to-edge repair because of high surgical risk or inappropriate mitral valve anatomy. OBJECTIVES: The aim of this study was to evaluate the HighLife Trans-Septal Mitral Valve Replacement (TSMVR) system in patients with symptomatic MR and high surgical risk. METHODS: This prospective, multicenter, nonrandomized feasibility study evaluated the safety and performance of the HighLife TSMVR system in patients with moderate to severe or severe symptomatic MR during 1-year follow-up. Echocardiographic data were assessed at an independent core laboratory. RESULTS: A total of 30 patients (mean age 75.6 years, 27% women, median Society of Thoracic Surgeons score 5.5%) with severe MR (90% with secondary MR, median left ventricular ejection fraction 43%) were treated at 13 sites. In 27 of the 30 patients, the HighLife TSMVR system was implanted successfully (technical success rate 90%). Device success at 30 days was 83%. After 1 year, 5 patients (17%) had died. None of the patients who underwent implantation required mitral valve reintervention. All patients who underwent implantation had no or trace (78%) or mild (22%) MR, the mean gradient of the HighLife valve was 5.1 mm Hg, and there were no signs of left ventricular outflow tract obstruction (mean gradient 2.0 mm Hg). CONCLUSIONS: The 1-year results from the HighLife TSMVR feasibility study demonstrate a high technical success rate, excellent valve function, no left ventricular outflow tract obstruction, and no need for mitral valve reintervention. Additional patient outcomes and longer follow-up are needed to confirm these findings. (Expanded Study of the HighLife 28mm Trans-Septal Trans-Catheter Mitral Valve in Patients With Moderate-Severe or Severe Mitral Regurgitation and at High Surgical Risk; NCT04029363).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Aged , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Stroke Volume , Feasibility Studies , Prospective Studies , Ventricular Function, Left , Treatment Outcome , Cardiac Catheterization
10.
J Clin Med ; 12(19)2023 Sep 25.
Article in English | MEDLINE | ID: mdl-37834835

ABSTRACT

BACKGROUND: Improvement in concomitant tricuspid regurgitation (TR) after mitral valve transcatheter edge-to-edge repair (M-TEER) for mitral regurgitation (MR) occurs frequently; however factors determining the post-procedural course of TR are not well understood. We investigated the parameters associated with TR improvement after M-TEER. METHODS AND RESULTS: A total of 300 patients were consecutively included in this retrospective analysis. MR and TR severity as well as heart chamber metrics were assessed before the procedure and at follow-up. Device success was achieved in 97.3% of patients. TR decreased in 30.2% of patients. Patients with improved TR were more often female, had more severe TR at baseline, and their right heart dimensions at baseline trended to be smaller. Female sex (odds ratio (OR) 2.997), baseline MR-Grade (OR 3.181) and baseline TR-Grade (OR 2.653) independently predicted TR reduction. More pronounced right heart reverse remodeling was observed in patients with improved TR. TR regression independently predicted lower mortality (hazard ratio (HR) 0.333, 95% confidence interval 0.112-0.996, p = 0.049). CONCLUSIONS: A reduction in concomitant TR severity after M-TEER occurred mainly in females and in patients with high-grade TR and MR at baseline. TR regression is associated with better survival after M-TEER.

11.
Catheter Cardiovasc Interv ; 102(3): 528-537, 2023 09.
Article in English | MEDLINE | ID: mdl-37506125

ABSTRACT

AIMS: To evaluate the impact of tricuspid regurgitation (TR) on echocardiographic and functional outcome after mitral valve transcatheter edge-to-edge-repair (M-TEER). METHODS AND RESULTS: A total of 740 patients underwent M-TEER at our center from 2010 to 2021. Patients were analyzed according to severity of concomitant TR at the time of M-TEER procedure: low-grade TR (grade ≤I [trace-mild], 279 patients [37.7%]), moderate TR (grade II, 170 patients [23.0%]) and high-grade TR (grade III-V [severe-torrential], 291 patients [39.3%]). Patients with moderate to high-grade TR had higher morbidity. Procedural success of M-TEER was achieved similarly in all groups (98.2% vs. 97.6% vs. 95.9%, p = 0.22). TR severity decreased rapidly and consistently after M-TEER to only 48.0% of high-grade TR patients after 3 months (p < 0.001) and to 46.8% after 12 months (p = 0.99). High-grade TR patients had significantly higher mortality (21.5% vs. 18.2% vs. 11.1%, p = 0.003) up to 12 months after M-TEER. However, high-grade TR did not independently predict mortality (HR 1.302, 95% CI 0.937-1.810; p = 0.116). Echocardiographic and functional outcome was similar in both secondary and primary MR patients. CONCLUSIONS: High-grade concomitant TR did not independently predict adverse outcome following M-TEER. A wait-and-observe approach for these patients is reasonable.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Tricuspid Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Treatment Outcome
12.
Clin Res Cardiol ; 112(10): 1436-1445, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37405481

ABSTRACT

BACKGROUND: The development of transcatheter tricuspid edge-to-edge repair for tricuspid regurgitation is a therapeutic milestone but a specific periprocedural risk assessment tool is lacking. TRI-SCORE has recently been introduced as a dedicated risk score for tricuspid valve surgery. AIMS: This study analyzes the predictive performance of TRI-SCORE following transcatheter edge-to-edge tricuspid valve repair. METHODS: 180 patients who underwent transcatheter tricuspid valve repair at Ulm University Hospital were consecutively included and stratified into three TRI-SCORE risk groups. The predictive performance of TRI-SCORE was assessed throughout a follow-up period of 30 days and up to 1 year. RESULTS: All patients had severe tricuspid regurgitation. Median EuroSCORE II was 6.4% (IQR 3.8-10.1%), median STS-Score 8.1% (IQR 4.6-13.4%) and median TRI-SCORE 6.0 (IQR 4.0-7.0). 64 patients (35.6%) were in the low TRI-SCORE group, 91 (50.6%) in the intermediate and 25 (13.9%) in the high-risk groups. The procedural success rate was 97.8%. 30-day mortality was 0% in the low-risk group, 1.3% in the intermediate-risk and 17.4% in the high-risk groups (p < 0.001). During a median follow-up of 168 days mortality was 0%, 3.8% and 52.2%, respectively (p < 0.001). The predictive performance of TRI-SCORE was excellent (AUC for 30-day mortality: 90.3%, for one-year mortality: 93.1%) and superior to EuroSCORE II (AUC 56.6% and 64.4%, respectively) and STS-Score (AUC 61.0% and 59.0%, respectively). CONCLUSION: TRI-SCORE is a valuable tool for prediction of mortality after transcatheter edge-to-edge tricuspid valve repair and its performance is superior to EuroSCORE II and STS-Score. In a monocentric cohort of 180 patients undergoing edge-to-edge tricuspid valve repair TRI-SCORE predicted 30-day and up to one-year mortality more reliably than EuroSCORE II and STS-Score. AUC area under the curve, 95% CI 95% confidence interval.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Heart Valve Prosthesis Implantation/adverse effects , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/surgery , Risk Factors , Risk Assessment , Treatment Outcome
13.
Front Cardiovasc Med ; 10: 1132626, 2023.
Article in English | MEDLINE | ID: mdl-37424915

ABSTRACT

Introduction: Percutaneous closure of the left atrial appendage (LAA) facilitates stroke prevention in patients with atrial fibrillation. Optimal device selection and positioning are often challenging due to highly variable LAA shape and dimension and thus require accurate assessment of the respective anatomy. Transesophageal echocardiography (TEE) and x-ray fluoroscopy (XR) represent the gold standard imaging techniques. However, device underestimation has frequently been observed. Assessment based on 3-dimensional computer tomography (CTA) has been reported as more accurate but increases radiation and contrast agent burden. In this study, the use of non-contrast-enhanced cardiac magnetic resonance imaging (CMR) to support preprocedural planning for LAA closure (LAAc) was investigated. Methods: CMR was performed in thirteen patients prior to LAAc. Based on the 3-dimensional CMR image data, the dimensions of the LAA were quantified and optimal C-arm angulations were determined and compared to periprocedural data. Quantitative figures used for evaluation of the technique comprised the maximum diameter, the diameter derived from perimeter and the area of the landing zone of the LAA. Results: Perimeter- and area-based diameters derived from preprocedural CMR showed excellent congruency compared to those measured periprocedurally by XR, whereas the respective maximum diameter resulted in significant overestimation (p < 0.05). Compared to TEE assessment, CMR-derived diameters resulted in significantly larger dimensions (p < 0.05). The deviation of the maximum diameter to the diameters measured by XR and TEE correlated well with the ovality of the LAA. C-arm angulations used during the procedures were in agreement with those determined by CMR in case of circular LAA. Discussion: This small pilot study demonstrates the potential of non-contrast-enhanced CMR to support preprocedural planning of LAAc. Diameter measurements based on LAA area and perimeter correlated well with the actual device selection parameters. CMR-derived determination of landing zones facilitated accurate C-arm angulation for optimal device positioning.

14.
Front Cardiovasc Med ; 10: 1143702, 2023.
Article in English | MEDLINE | ID: mdl-37424917

ABSTRACT

Background: Mitral annular alterations in the context of heart failure often lead to severe functional mitral regurgitation (FMR), which should be treated with transcatheter edge-to-edge repair (M-TEER) according to current guidelines. M-TEER's effects on mitral valve (MV) annular remodeling have not been well elucidated. Methods: 141 consecutive patients undergoing M-TEER for treatment of FMR were included in this investigation. Comprehensive intraprocedural transesophageal echocardiography was used to assess the acute effects of M-TEER on annular geometry. Results: Average patient age was 76.2 ± 9.6 years and 46.1% were female patients. LV ejection fraction was reduced (37.0% ± 13.7%) and all patients had mitral regurgitation (MR) grade ≥III. M-TEER achieved optimal MR reduction (MR ≤ I) in 78.6% of patients. Mitral annular anterior-posterior diameters (A-Pd) were reduced by -6.2% ± 9.5% on average, whereas anterolateral-posteromedial diameters increased (3.7% ± 8.9%). Overall, a reduction in MV annular areas was observed (2D: -1.8% ± 13.1%; 3D: -2.7% ± 13.7%), which strongly correlated with A-Pd reduction (2D: r = 0.6, p < 0.01; 3D: r = 0.65, p < 0.01). Patients that achieved A-Pd reduction above the median (≥6.3%) showed significantly lower rates of the composite endpoint rehospitalization for heart failure or all-cause mortality than those with less A-Pd reduction (9.9% vs. 28.6%, p = 0.037, log-rank p = 0.039). Furthermore, patients reaching the composite endpoint had an increase in annular area (2D: 3.0% ± 15.4%; 3D: 1.9% ± 15.3%), whereas those not reaching the endpoint showed a decrease (2D: -2.7% ± 12.4%; 3D: -3.6% ± 13.3%), although residual MR after M-TEER was similar between these groups (p = 0.57). In multivariate Cox regression adjusted for baseline MR, A-Pd reduction ≥6.3% remained a significant predictor of the combined endpoint (OR: 0.35, 95% CI: 0.14-0.85, p = 0.02). Conclusion: Our findings indicate that effects of M-TEER in FMR are not limited to MR reduction, but also have significant impact on annular geometry. Moreover, A-Pd reduction, which mediates annular remodeling, has a significant impact on clinical outcome independent of residual MR.

15.
J Clin Med ; 12(10)2023 May 16.
Article in English | MEDLINE | ID: mdl-37240610

ABSTRACT

BACKGROUND: Diabetes mellitus worsens outcomes in patients suffering from heart disease undergoing cardiac procedures. OBJECTIVES: To investigate the impact of diabetes in patients undergoing mitral transcatheter edge-to-edge repair (M-TEER). METHODS: 1118 patients treated with M-TEER for functional (FMR) and degenerative (DMR) mitral regurgitation (MR) between 2010 and 2021 were analyzed using the combined endpoint of death/rehospitalization for heart failure (HFH). RESULTS: Among diabetics (N = 306; 27.4%), comorbidities such as coronary artery disease (75.2% vs. 62.7%; p < 0.001) and progressed (stage III/IV) chronic kidney disease (79.5% vs. 72.6%; p = 0.018) were more frequent. The rate of FMR was higher in diabetics (71.9% vs. 64.5%; p < 0.001). The combined endpoint occurred more frequently in diabetics (40.2% vs. 35.6%; log-rank = 0.035). While no difference was observed in FMR patients (36.8% vs. 37.6%; log-rank p = 0.710), rates of the combined endpoint differed significantly between diabetics and non-diabetics in DMR patients (48.8% vs. 31.9%; log-rank p = 0.001) only. However, diabetes did neither predict the combined endpoint in the overall (OR: 0.97; 95% CI 0.65-1.45; p = 0.890) nor in the DMR cohort (OR: 0.73; 95% CI 0.35-1.51; p = 0.389). Among diabetics treated with M-TEER, troponin (OR: 2.32; 95% CI 1.3-3.7; p = 0.002) and estimated glomerular filtration rate (OR: 0.52; 95% CI 0.3-0.88; p = 0.018) independently predicted the combined endpoint. CONCLUSIONS: Diabetes is associated with adverse outcomes after M-TEER, particularly in DMR patients. However, diabetes does not predict the combined endpoint. In diabetics undergoing M-TEER, biochemical markers associated with organ function and damage independently predict the combined endpoint of death and rehospitalization.

16.
Int J Comput Assist Radiol Surg ; 18(11): 2111-2116, 2023 Nov.
Article in English | MEDLINE | ID: mdl-36997829

ABSTRACT

PURPOSE: Percutaneous closure of the left atrial appendage (LAA) reduces the risk of embolic stroke in patients with atrial fibrillation. Thereby, the optimal transseptal puncture (TSP) site differs due to the highly variable anatomical shape of the LAA, which is rarely considered in existing training models. Based on non-contrast-enhanced magnetic resonance imaging (MRI) volumes, we propose a training model for LAA closure with interchangeable and patient-specific LAA enabling LAA-specific identification of the TSP site best suited. METHODS: Based on patient-specific MRI data, silicone models of the LAAs were produced using a 3D-printed cast model. In addition, an MRI-derived 3D-printed base model was set up, including the right and left atrium with predefined passages in the septum, mimicking multiple TSP sites. The various silicone models and a tube mimicking venous access were connected to the base model. Empirical use of the model allowed the demonstration of its usability. RESULTS: Patient-specific silicone models of the LAA could be generated from all LAA patient MRI datasets. The influence of various combinations regarding TSP sites and LAA shapes could be demonstrated as well as the technical functionality of the occluder system. Via the attached tube mimicking the venous access, the correct handling of the deployment catheter even in case of not optimal puncture site could be practiced. CONCLUSION: The proposed contrast-agent and radiation-free MRI-based training model for percutaneous LAA closure enables the pre-interventional assessment of the influence of the TSP site on the access of patient-specific LAA shapes. A straightforward replication of this work is measured by using clinically available imaging protocols and a widespread 3D printer technique to build the model.

17.
JACC Cardiovasc Interv ; 15(24): 2554-2567, 2022 12 26.
Article in English | MEDLINE | ID: mdl-36543450

ABSTRACT

BACKGROUND: Since its introduction in 2003, Abbott's MitraClip (MC) has become the most established catheter-based treatment for mitral regurgitation (MR). Recent approval of Edwards Lifescience's PASCAL device has extended the field of TEER. OBJECTIVES: The aim of this retrospective multicenter study was to compare the PASCAL and MC regarding procedural results and short- and long-term outcomes after mitral valve transcatheter edge-to-edge repair (TEER). METHODS: Data from 3 high-volume centers were analyzed. The primary endpoint was residual MR at discharge. Secondary endpoints were technical success, MR reduction, and 30-day mortality. After 1 year, all-cause mortality and residual MR were reported. RESULTS: A total of 412 patients (216 MC, 196 PASCAL) treated between 2018 and 2020 were included. A total of 184 patients (92 in each treatment group) remained after propensity score matching. The rate of baseline MR ≥3 was 98.9% in both groups (P = 1.00). Both TEER systems achieved equally high technical success rates (97.8%; P = 1.00), resulting in residual MR ≤1 in 69.6% vs 77.1% of patients (P = 0.24) and MR reduction by ≥2 grades in 83.7% vs 92.4% of patients (P = 0.13) using the MC and PASCAL, respectively. Thirty-day mortality was 1.1% in both cohorts (P = 0.98), and 1-year follow-up showed similar MR reductions (residual MR ≤1, 78.0% with MC vs 82.3% with PASCAL; P = 0.70) and comparable all-cause mortality (14.1% with MC vs 6.5% with PASCAL; P = 0.14). In multivariate regression analysis, Society of Thoracic Surgeons score independently correlated with an optimal result (MR ≤1), while device choice did not show a significant impact. CONCLUSIONS: In this retrospective multicenter study, the established MC and the novel PASCAL mitral valve TEER systems were safe and offered excellent performance with comparable short- and long-term outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Propensity Score , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Cardiac Catheterization
18.
Front Cardiovasc Med ; 9: 931959, 2022.
Article in English | MEDLINE | ID: mdl-36324746

ABSTRACT

Preprocedural planning and periprocedural guidance based on image fusion are widely established techniques supporting the interventional treatment of structural heart disease. However, these two techniques are typically used independently. Previous works have already demonstrated the benefits of integrating planning details into image fusion but are limited to a few applications and the availability of the proprietary tools used. We propose a vendor-independent approach to integrate planning details into periprocedural image fusion facilitating guidance during interventional treatment. In this work, we demonstrate the feasibility of integrating planning details derived from computer tomography and magnetic resonance imaging into periprocedural image fusion with open-source and commercially established tools. The integration of preprocedural planning details into periprocedural image fusion has the potential to support safe and efficient interventional treatment of structural heart disease.

19.
J Clin Med ; 11(5)2022 Mar 04.
Article in English | MEDLINE | ID: mdl-35268513

ABSTRACT

OBJECTIVE: We aimed to investigate the demographic, clinical and hemodynamic characteristics of patients who underwent percutaneous mitral valve (MV) repair over the last decade, as well as to determine the potential changes in trends of these parameters among patients with structural and functional MR (SMR and FMR). METHODOLOGY: We analyzed all patients who underwent interventional MV repair in our institution between January 2010 and March 2021. Our study included both SMR and FMR patients. All data were obtained from a local registry. RESULTS: Nine hundred and seventeen patients (357 SMR patients and 563 FMR patients) were involved in this study. We did not find significant differences in demographical, clinical and hemodynamic characteristics among SMR and FMR patients. Left ventricular remodeling and systolic dysfunction were more pronounced in FMR patients. Systemic vascular resistance was the only hemodynamic parameter that differed between SMR and FMR patients; it was higher in SMR group. An evaluation of the trend between the first and last five years of our experience revealed that the number of patients treated with this technique is constantly increasing, but that this is more pronounced in SMR patients. It was also found that the operative risk of SMR and FMR patients was significantly higher in the first five years. Additionally, our results showed change in medical therapy in MR patients over the last decade in terms of increased use of angiotensin II receptor blockers and the introduction of angiotensin receptor II blocker-neprilysin inhibitor. CONCLUSION: SMR and FMR patients who underwent interventional MV repair have similar clinical and hemodynamic characteristics. The percentage of SMR patients increased more significantly than FMR patients over the last five years.

20.
Front Cardiovasc Med ; 9: 850356, 2022.
Article in English | MEDLINE | ID: mdl-35350535

ABSTRACT

Objective: This study sought to determine the potential change in trends in the baseline characteristics of patients with symptomatic severe mitral regurgitation who underwent transcatheter edge-to-edge mitral valve repair (M-TEER) over the last decade in a high-volume center. Methodology: The investigation included 942 symptomatic patients with moderate-to-severe and severe mitral regurgitation who underwent transcatheter edge-to-edge repair (TEER) at our institution between January 2010 and March 2021. Patients were divided into quintiles and compared separately. Results: Patients treated in the last quintile had significantly lower surgical risk (Euro Score 7.2 ± 6.8% in the last quintile vs. 10.9 ± 9.4% in the first quintile, p < 0.001), better New York Heart Association (NYHA) status (NYHA IV 14% in the last quintile vs. 40% in the first quintile, p < 0.001), lower NT-pro-BNP, and smaller left ventricle diameter than patients who were treated in the first quintile. There was no difference in age between quintiles. However, an invasive hemodynamic assessment did not show significant changes over the last decade (sPAP 51.35 ± 16.2 mmHg in the first quintile vs. 51.02 ± 14.5 mmHg in the last quintile, p = 0.90, pulmonary capillary wedge V wave 30.7 ± 14.8 mmHg in the first quintile vs. 27.4 ± 10.3 mmHg in the last quintile, p = 0.40). There is a significant trend of a gradually increasing proportion of patients with degenerative mitral regurgitation (MR) over the last 10 years (p < 0.001). The experience gained in the M-TEER procedure brought a significant reduction in fluoroscopy time and hospitalization duration. Medical therapy significantly changed over the last decade in terms of higher use of angiotensin receptor blockers (ARBs), lower use of angiotensin-converting enzyme inhibitors (ACEIs), and the introduction of angiotensin receptor-neprilysin inhibitors (ARNIs). Conclusion: Patients undergoing the M-TEER procedure nowadays have lower surgical risk and are treated before they develop a significant left ventricular (LV) remodeling than before. The increasing expertise on the procedure over the last decade led to a rising number of patients with complex degenerative pathology being treated.

SELECTION OF CITATIONS
SEARCH DETAIL