1.
J Biomech ; 146: 111424, 2023 01.
Article in English | MEDLINE | ID: mdl-36603366

ABSTRACT

Femoroacetabular impingement syndrome (FAIS) is a motion-related pathology of the hip characterized by pain, morphological abnormalities of the proximal femur, and an elevated risk of joint deterioration and hip osteoarthritis. Activities that require deep flexion are understood to induce impingement in cam FAIS patients, however, less demanding activities such as walking and pivoting may induce pain as well as alterations in kinematics and joint stability. Still, the paucity of quantitative descriptions of cam FAIS has hindered understanding underlying hip joint mechanics during such activities. Previous in silico studies have employed generalized model geometry or kinematics to simulate impingement between the femur and acetabulum, which may not accurately capture the interplay between morphology and motion. In this study, we utilized models with participant-specific bone and articular soft tissue anatomy and kinematics measured by dual-fluoroscopy to compare hip contact mechanics of cam FAIS patients to controls during four activities of daily living (internal/external pivoting and level/incline walking). Averaged across the gait cycle during incline walking, patients displayed increased strain in the anterior joint (labrum strain: p-value = 0.038, patients: 11.7 ± 6.7 %, controls: 5.0 ± 3.6 %; cartilage strain: p-value = 0.029, patients: 9.1 ± 3.3 %, controls: 4.2 ± 2.3). Patients also exhibited increased average anterior cartilage strains during external pivoting (p-value = 0.039; patients: 13.0 ± 9.2 %, controls: 3.9 ± 3.2 %]). No significant differences between patient and control contact area and strain were found for level walking and internal pivoting. Our study provides new insights into the biomechanics of cam FAIS, including spatiotemporal hip joint contact mechanics during activities of daily living.


Subject(s)
Femoracetabular Impingement , Humans , Activities of Daily Living , Hip Joint , Acetabulum , Walking , Cartilage , Pain
3.
Orthop J Sports Med ; 10(2): 23259671211073834, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35141341

ABSTRACT

BACKGROUND: The anterior center-edge angle (ACEA) is used to quantify anterior coverage of the femoral head by the acetabulum. However, its measurement has not been evaluated in a manner consistent with routine use, and the precise 3-dimensional (3D) anatomic location where it measures coverage is not known. PURPOSE: To determine the effect of patient positioning on ACEA measurement reliability, magnitude, and 3D location. STUDY DESIGN: Descriptive laboratory study. METHODS: Included were 18 adults; 7 participants had cam morphology and femoroacetabular impingement syndrome, and 11 participants had no radiographic evidence of hip abnormalities and no history of hip pain or injuries. Ultimately, 3D femur and pelvis models were generated from computed tomography images. Radiographs were generated with the models in different degrees of pelvic rotation, tilt, and obliquity relative to the standard false-profile view. The ACEA was measured by 2 raters by selecting the location of the bone edge on each radiograph. Selections were projected onto the pelvis model and expressed as a clockface location on the acetabular rim. The clockface was mirrored on left hips to allow a direct comparison of locations between hips. Interrater and intrarater reliability were quantified via the intraclass correlation coefficient (ICC). The effect of position on ACEA measurements and clockface locations was determined via linear regression. RESULTS: Intrarater and interrater reliability were excellent (ICC ≥0.97 for all). For every degree increase in rotation, tilt, and obliquity, the ACEA changed by +0.53°, +0.93°, and -0.04°, respectively. The mean clockface location (hour:minute:second) in the false-profile view was 2:09:32 ± 0:12:00 and changed by +0:02:08, -0:00:35, and -0:00:05 for every degree increase in rotation, tilt, and obliquity, respectively. CONCLUSION: ACEA measurements were reliable even with differences in patient positioning. Rotation and tilt were associated with notable changes in ACEA measurements. ACEA bone edge measurements mapped to the anterosuperior acetabular rim, typically in proximity to the anterior inferior iliac spine. Mapped location was most sensitive to rotation. CLINICAL RELEVANCE: Pelvic rotation and tilt affected ACEA measurements, which could alter the clinical classification and treatment of borderline abnormalities. Rotation in particular must be well controlled during patient imaging to preserve measurement reliability and accuracy and to describe coverage from the intended 3D rim location.

SELECTION OF CITATIONS