Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 63
Filter
1.
Article in English | MEDLINE | ID: mdl-38972630

ABSTRACT

OBJECTIVE: Challenging infrarenal aortic neck characteristics have been associated with increased risk of a type Ia endoleak after endovascular aneurysm repair (EVAR). Short apposition (< 10 mm circumferential shortest apposition length [SAL]) on the first post-operative computerised tomography angiography (CTA) has been associated with type Ia endoleak. Therefore, this study aimed to develop a model to predict post-operative SAL in patients with an abdominal aortic aneurysm based on the pre-operative shape. METHODS: A statistical shape model was developed to obtain principal component scores. The dataset comprised patients treated with standard EVAR without complications (n = 93) enriched with patients with a late type Ia endoleak (n = 54). The infrarenal SAL was obtained from the first post-operative CTA and subsequently binarised (< 10 mm and ≥ 10 mm). The principal component scores that were statistically different between the SAL groups were used as input for five classification models, and evaluated by means of leave one out cross validation. Area under the receiver operating characteristics curves (AUC), accuracy, sensitivity, and specificity were determined for each classification model. RESULTS: Of the 147 patients, 24 patients had an infrarenal SAL < 10 mm and 123 patients had a SAL ≥ 10 mm. The gradient boosting model resulted in the highest AUC of 0.77. Using this model, 114 (78.0%) patients were correctly classified; sensitivity (< 10 mm apposition was correctly predicted) and specificity (≥ 10 mm apposition was correctly predicted) were 0.70 and 0.79, and were based on a threshold of 0.21, respectively. CONCLUSION: A model was developed to predict which patients undergoing EVAR will achieve sufficient graft apposition (≥ 10 mm) in the infrarenal aortic neck based on a statistical shape model of pre-operative CTA data. This model can help vascular specialists during the planning phase to accurately identify patients who are unlikely to achieve sufficient apposition after standard EVAR.

2.
J Endovasc Ther ; : 15266028241248600, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38708986

ABSTRACT

PURPOSE: The primary aim of this study was to assess the 3-dimensional flare geometry of the Gore Viabahn VBX balloon-expandable covered stent (BECS) after fenestrated endovascular aortic repair (FEVAR) and to determine and visualize BECS-associated complications. METHODS: This multicenter retrospective study included patients who underwent FEVAR between 2018 and 2022 in 3 vascular centers participating in the VBX Expand Registry. Patients with at least one visceral artery treated with the VBX and with availability of 2 post-FEVAR computed tomography angiography (CTA) scans (follow-up [FU] 1: 0-6 months; FU2: 9-24 months) were included. The flare geometry of the VBX, including flare-to-fenestration distance, flare-to-fenestration diameter ratio, flare angle, and apposition with the target artery were assessed using a vascular workstation and dedicated CTA applied software. RESULTS: In total, 90 VBX BECS were analyzed in 43 FEVAR patients. The median CTA FU for FU1 and FU2 was 35 days (interquartile range [IQR], 29-51 days) and 14 months (IQR, 13-15 months), respectively. The mean flare-to-fenestration distance was 5.6±2.0 mm on FU1 and remained unchanged at 5.7±2.0 mm on FU2 (p=.417). The flare-to-fenestration diameter ratio was 1.19±0.17 on FU1 and remained unchanged at 1.21±0.19 (p=.206). The mean apposition length was 18.6±5.3 mm on FU1 and remained 18.6±5.3 mm (p=.550). The flare angle was 31°±15° on FU1 and changed to 33°±16° (p=.009). On FU1, the BECS-associated complication rate was 1%, and the BECS-associated reintervention rate was 0%. On FU2, the BECS-associated complication rate was 3%, and the BECS-associated reintervention rate was 1%. CONCLUSIONS: The flare geometry of the VBX bridging stent did not change significantly during 14 months follow-up in this study. Three-dimensional geometric analysis of the flare may contribute to identify the origin of endoleaks and occlusions, but this should be confirmed in a larger study including enough patients and BECS to compare complicated and uncomplicated cases. CLINICAL IMPACT: The three-dimensional flare geometry of the Gore Viabahn VBX BECS was assessed on the first and second postoperative CTA scans, and geometrical changes during this period were identified. For BECS that were diagnosed with a type 3c endoleak or occlusion, the BECS geometry was analyzed to detect geometrical components that were related to the complication. Geometric analysis of the flare may help to better detect and identify the cause of such complications.

3.
Article in English | MEDLINE | ID: mdl-38670221

ABSTRACT

OBJECTIVE: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck. METHODS: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiogram (CTA) were selected from four hospitals in a prospective registry. Endograft apposition (shortest apposition length [SAL]) and position (shortest fabric distance [SFD]) were assessed on the 30 day and one year CTAs. Maximum infrarenal aortic curvature was compared between the pre- and post-operative CTAs to evaluate conformability of the CEXC. RESULTS: There were 87 patients with a 30 day CTA, and for 56 of these patients the one year CTA was available. Median (interquartile range [IQR]) pre-operative neck length was 22 mm (IQR 15, 32) and infrarenal angulation was 52° (IQR 31, 72). Median SAL was 21.2 mm (IQR 14.0, 29.3) at 30 days for all included patients. The SAL in 13 patients (15%) was < 10 mm at 30 days, and one patient had a SAL of 0 mm and a type Ia endoleak. There was no significant difference in SAL between patients within and outside instructions for use. The SAL significantly increased by 1.1 mm (IQR -2.3, 4.7; p = .042) at one year. The SAL decreased in seven patients (13%), increased in 13 patients (23%), and remained stable in 36 patients (64%). Median SFD was 2.0 mm (IQR 0.5, 3.6) at 30 days, which slightly increased by 0.3 mm (IQR -0.5, 1.8; p = .019) at one year. One patient showed migration (SFD increase ≥ 5 mm). Median endograft tilt was 15.8° (IQR 9.7, 21.4). Pre-operative maximum infrarenal curvature was 36 m-1 (IQR 26, 56) and did not significantly change thereafter. CONCLUSION: In most patients, the CEXC was implanted close to the renal arteries, and sufficient (≥ 10 mm) post-operative apposition was achieved at 30 days, which slightly increased at one year. Post-operative endograft tilt was relatively low, and aortic geometry remained unchanged after implantation of the CEXC, probably due to its high conformability.

4.
J Clin Med ; 13(6)2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38542032

ABSTRACT

Background: Endovascular techniques have gained preference over peripheral arterial bypass surgery due to their minimally invasive nature; however, endovascular treatments often show limited efficacy in arterial segments with a high atherosclerotic load. The use of atherectomy devices enables the removal of calcified plaque material and may promote arterial wall remodeling. This study assessed the technical success, safety, and feasibility of the BYCROSS® atherectomy device in femoropopliteal lesions. Methods: This single-center, retrospective cohort study analyzed elective patients undergoing BYCROSS® atherectomy for chronic peripheral arterial disease from March 2022 to May 2023. Patient data, procedural details, and outcomes were retrospectively collected from electronic patient records. The primary performance endpoints of this study were technical success, complications, and patency rates. Primary safety endpoints included 30-day and short-term major adverse limb events (MALEs), major adverse cardiovascular events (MACEs), and mortality rate. Results: The study included 19 patients (median age, 71 years; 63% male) with Fontaine class IIb (26%), III (21%), or IV (53%). The BYCROSS® atherectomy device was used to treat 22 limbs in the femoropopliteal tract, of which 11 lesions (50%) were occlusions and 11 were stenoses, with a median length of 24 cm (interquartile range: 17-38). Technical success was achieved in all cases: 4.5% required atherectomy only, 50% required additional balloon angioplasties, 41% required balloon angioplasties and stenting, and 4.5% required segments only stenting. Additional treatment of below-the-knee arteries was performed in 12 patients. Procedurally related complications (not limited to the use of the BYCROSS® device) occurred in 23% of limbs, including distal embolization and laceration. At 30 days, mortality was 5%, the MACE rate was 11%, and the MALE rate was 0%. The observed mortality rate was not directly related to the procedure. Patency (<50% restenosis at duplex ultrasound) was 83% at 30 days. Conclusions: The use of the BYCROSS® atherectomy device for the treatment of femoropopliteal lesions appears to be safe and feasible, with high technical success and low MALE and MACE rates in a challenging population with long-segment femoropopliteal lesions. Long-term follow-up in larger patient series is needed to confirm these findings and to determine the durability of this technique.

5.
Eur J Vasc Endovasc Surg ; 67(6): 935-947, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38552837

ABSTRACT

OBJECTIVE: This scoping review summarises health literacy and disease knowledge in patients with abdominal aortic aneurysm (AAA) or peripheral arterial disease (PAD) and the influencing factors. DATA SOURCES: A systematic search was conducted in PubMed, Embase, PsychINFO, and CINAHL covering the period January 2012 to October 2022. REVIEW METHODS: This scoping review was undertaken in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR). Inclusion criteria encompassed studies addressing health literacy, knowledge, perception, or awareness in patients with AAA or PAD. Two authors independently reviewed abstracts and full texts, resolving any discrepancies through discussion or by consulting a third author for consensus. All article types were included except letters, editorials, study protocols, reviews, and guidelines. No language restrictions were applied. Primary outcomes were health literacy and disease knowledge. Secondary outcomes were factors that could influence this. Quality assessment was done using the Mixed Methods Appraisal Tool (MMAT). RESULTS: The review included 32 articles involving a total of 5 268 patients. Four articles reported health literacy and the rest disease knowledge. Ten studies (31%) met all quality criteria. Twenty studies were quantitative, eight were qualitative, and four were mixed methods studies. The review revealed inadequate health literacy in the majority of patients, and disease knowledge was relatively low among patients with AAA and PAD, with disparities in measures and assessment tools across studies. Factors influencing health literacy and disease knowledge included socioeconomic status, education, income, and employment. CONCLUSION: This scoping review revealed low health literacy and low disease knowledge in patients with AAA and PAD. Standardised health literacy assessment may contribute to improve communication strategies and decision aids to enhance patients' understanding and engagement in healthcare decisions, however further research is needed to prove its merits.


Subject(s)
Aortic Aneurysm, Abdominal , Health Knowledge, Attitudes, Practice , Health Literacy , Peripheral Arterial Disease , Humans , Aortic Aneurysm, Abdominal/surgery , Peripheral Arterial Disease/diagnosis , Patient Education as Topic
6.
J Cardiovasc Surg (Torino) ; 65(2): 99-105, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38551514

ABSTRACT

The initial success and widespread adoption of endovascular aneurysm repair (EVAR) for the treatment of abdominal aortic aneurysms have been tempered by numerous reports of secondary interventions and increased long-term mortality compared with open repair. Over the past decade, several studies on postoperative sac dynamics after EVAR have suggested that the presence of sac regression is a benign feature with a favorable prognosis. Conversely, increasing sacs and even stable sacs can be indicators of more unstable sac behavior with worse outcomes in the long-term. Endoleaks were initially perceived as the main drivers of sac behavior. However, the observation that sac regression can occur in the presence of endoleaks, and vice versa - increasing sacs without evidence of endoleak - on imaging studies, suggests the involvement of other contributing factors. These factors can be divided into anatomical factors, patient characteristics, sac thrombus composition, and device-related factors. The shift of interest away from especially type 2 endoleaks is further supported by promising results with the use of EndoAnchors regarding postoperative sac behavior. This review provides an overview of the existing literature on the implications and known risk factors of post-EVAR sac behavior, describes the accurate measurement of sac behavior, and discusses the use of EndoAnchors to promote sac regression.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endoleak , Endovascular Procedures , Humans , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endoleak/etiology , Risk Factors , Treatment Outcome , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Prosthesis Design
7.
Eur Radiol ; 34(4): 2334-2351, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37672051

ABSTRACT

OBJECTIVES: Position- and posture-dependent deformation of the vascular system is a relatively unexplored field. The goal of this scoping review was to create an overview of existing vascular imaging modalities in different body positions and postures and address the subsequent changes in vascular anatomy. METHODS: Scopus, Medline, and Cochrane were searched for literature published between January 1, 2000, and June 30, 2022, incorporating the following categories: image modality, anatomy, orientation, and outcomes. RESULTS: Out of 2446 screened articles, we included 108. The majority of papers used ultrasound (US, n = 74) in different body positions and postures with diameter and cross-sectional area (CSA) as outcome measures. Magnetic resonance imaging (n = 22) and computed tomography (n = 8) were less frequently used but allowed for investigation of other geometrical measures such as vessel curvature and length. The venous system proved more sensitive to postural changes than the arterial system, which was seen as increasing diameters of veins below the level of the heart when going from supine to prone to standing positions, and vice versa. CONCLUSIONS: The influence of body positions and postures on vasculature was predominantly explored with US for vessel diameter and CSA. Posture-induced deformation and additional geometrical features that may be of interest for the (endovascular) treatment of vascular pathologies have been limitedly reported, such as length and curvature of an atherosclerotic popliteal artery during bending of the knee after stent placement. The most important clinical implications of positional changes are found in diagnosis, surgical planning, and follow-up after stent placement. CLINICAL RELEVANCE STATEMENT: This scoping review presents the current state and opportunities of position- and posture-dependent imaging of vascular structures using various imaging modalities that are relevant in the fields of clinical diagnosis, surgical planning, and follow-up after stent placement. KEY POINTS: • The influence of body positions and postures on the vasculature was predominantly investigated with US for vessel diameter and cross-sectional area. • Research into geometrical deformation, such as vessel length and curvature adaptation, that may be of interest for the (endovascular) treatment of vascular pathologies is limited in different positions and postures. • The most important clinical implications of postural changes are found in diagnosis, surgical planning, and follow-up after stent placement.


Subject(s)
Posture , Tomography, X-Ray Computed , Humans , Magnetic Resonance Imaging/methods , Popliteal Artery
8.
Eur Radiol Exp ; 7(1): 82, 2023 12 21.
Article in English | MEDLINE | ID: mdl-38123829

ABSTRACT

BACKGROUND: Abdominal aortic endoleaks after endovascular aneurysm repair might be position-dependent, therefore undetectable using supine imaging. We aimed to determine the feasibility and benefit of using a low-field tiltable magnetic resonance imaging (MRI) scanner allowing to study patients who can be imaged in both supine and upright positions of endoleaks. METHODS: Ten EVAR patients suspected of endoleak based on ultrasound examination were prospectively included. MRI in upright and supine positions was compared with routine supine computed tomography angiography (CTA). Analysis was performed through (1) subjective image quality assessment by three observers, (2) landmark registration between MRI and CTA scans, (3) Euclidean distances between renal and endograft landmarks, and (4) evaluation of endoleak detection on MRI by a consensus panel. Statistical analysis was performed by one-way repeated measures analysis of variance. RESULTS: The image quality of upright/supine MRI was inferior compared to CTA. Median differences in both renal and endograft landmarks were approximately 6-7 mm between upright and supine MRI and 5-6 mm between supine MRI and CTA. In the proximal sealing zone of the endograft, no differences were found among all three scan types (p = 0.264). Endoleak detection showed agreement between MRI and CTA in 50% of the cases, with potential added value in only one patient. CONCLUSIONS: The benefit of low-field upright MRI for endoleak detection was limited. While MRI assessment was non-inferior to standard CTA in detecting endoleaks in selected cases, improved hardware and sequences are needed to explore the potential of upright MRI in patients with endoleaks. RELEVANCE STATEMENT: Upright low-field MRI has limited clinical value in detecting position-dependent endoleaks; improvements are required to fulfil its potential as a complementary modality in this clinical setting. KEY POINTS: • Upright MRI shows potential for imaging endoleaks in aortic aneurysm patients in different positions. • The image quality of upright MRI is inferior to current techniques. • Upright MRI complements CTA, but lacks accurate deformation measurements for clinical use. • Advancements in hardware and imaging sequences are needed to fully utilise upright MRI capabilities.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Endoleak/diagnostic imaging , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Feasibility Studies , Endovascular Aneurysm Repair , Aortography/methods , Endovascular Procedures/methods , Treatment Outcome , Magnetic Resonance Imaging
9.
Sensors (Basel) ; 23(15)2023 Jul 27.
Article in English | MEDLINE | ID: mdl-37571519

ABSTRACT

Incorporating technology into healthcare processes is necessary to ensure the availability of high-quality care in the future. Wearable sensors are an example of such technology that could decrease workload, enable early detection of patient deterioration, and support clinical decision making by healthcare professionals. These sensors unlock continuous monitoring of vital signs, such as heart rate, respiration rate, blood oxygen saturation, temperature, and physical activity. However, broad and successful application of wearable sensors on the surgical ward is currently lacking. This may be related to the complexity, especially when it comes to replacing manual measurements by healthcare professionals. This report provides practical guidance to support peers before starting with the clinical application of wearable sensors in the surgical ward. For this purpose, the Non-Adoption, Abandonment, Scale-up, Spread, and Sustainability (NASSS) framework of technology adoption and innovations in healthcare organizations is used, combining existing literature and our own experience in this field over the past years. Specifically, the relevant topics are discussed per domain, and key lessons are subsequently summarized.


Subject(s)
Wearable Electronic Devices , Humans , Vital Signs/physiology , Heart Rate , Respiratory Rate , Hospitals
10.
Diagnostics (Basel) ; 13(11)2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37296786

ABSTRACT

BACKGROUND: The Agatston score on noncontrast computed tomography (CT) scans is the gold standard for calcium load determination. However, contrast-enhanced CT is commonly used for patients with atherosclerotic cardiovascular diseases (ASCVDs), such as peripheral arterial occlusive disease (PAOD) and abdominal aortic aneurysm (AAA). Currently, there is no validated method to determine calcium load in the aorta and peripheral arteries with a contrast-enhanced CT. This study validated a length-adjusted calcium score (LACS) method for contrast-enhanced CT scans. METHOD: The LACS (calcium volume in mm3/arterial length in cm) in the abdominal aorta was calculated using four-phase liver CT scans of 30 patients treated between 2017 and 2021 at the University Medical Center Groningen (UMCG) with no aortic disease. Noncontrast CT scans were segmented with a 130 Hounsfield units (HU) threshold, and a patient-specific threshold was used for contrast-enhanced CTs. The LACS was calculated and compared from both segmentations. Secondly, the interobserver variability and the influence of slice thickness (0.75 mm vs. 2.0 mm) was determined. RESULTS: There was a high correlation between the LACS from contrast-enhanced CT scans and the LACS of noncontrast CTs (R2 = 0.98). A correction factor of 1.9 was established to convert the LACS derived from contrast-enhanced CT to noncontrast CT scans. LACS interobserver agreement on contrast-enhanced CT was excellent (1.0, 95% confidence interval = 1.0-1.0). The 0.75 mm CT threshold was 541 (459-625) HU compared with 500 (419-568) HU on 2 mm CTs (p = 0.15). LACS calculated with both thresholds was not significantly different (p = 0.63). CONCLUSION: The LACS seems to be a robust method for scoring calcium load on contrast-enhanced CT scans in arterial segments with various lengths.

11.
J Clin Med ; 12(11)2023 May 30.
Article in English | MEDLINE | ID: mdl-37297962

ABSTRACT

Knowledge about anatomical shape variations in the pelvis is mandatory for selection, fitting, positioning, and fixation in pelvic surgery. The current knowledge on pelvic shape variation mostly relies on point-to-point measurements on 2D X-ray images and computed tomography (CT) slices. Three-dimensional region-specific assessments of pelvic morphology are scarce. Our aim was to develop a statistical shape model of the hemipelvis to assess anatomical shape variations in the hemipelvis. CT scans of 200 patients (100 male and 100 female) were used to obtain segmentations. An iterative closest point algorithm was performed to register these 3D segmentations, so a principal component analysis (PCA) could be performed, and a statistical shape model (SSM) of the hemipelvis was developed. The first 15 principal components (PCs) described 90% of the total shape variation, and the reconstruction ability of this SSM resulted in a root mean square error of 1.58 (95% CI: 1.53-1.63) mm. In summary, an SSM of the hemipelvis was developed, which describes the shape variations in a Caucasian population and is able to reconstruct an aberrant hemipelvis. Principal component analyses demonstrated that, in a general population, anatomical shape variations were mostly related to differences in the size of the pelvis (e.g., PC1 describes 68% of the total shape variation, which is attributed to size). Differences between the male and female pelvis were most pronounced in the iliac wing and pubic rami regions. These regions are often subject to injuries. Future clinical applications of our newly developed SSM may be relevant for SSM-based semi-automatic virtual reconstruction of a fractured hemipelvis as part of preoperative planning. Lastly, for companies, using our SSM might be interesting in order to assess which sizes of pelvic implants should be produced to provide proper-fitting implants for most of the population.

12.
J Clin Med ; 12(12)2023 Jun 10.
Article in English | MEDLINE | ID: mdl-37373662

ABSTRACT

Late type 1a endoleaks (T1aELs) after endovascular aneurysm repair (EVAR) are hazardous complications which should be avoided. This study investigated the evolution of the shortest apposition length (SAL) post-EVAR and hypothesised that a declining apposition during follow-up may be an indicator of T1aEL development. Patients with a late T1aEL were selected from a consecutive multicentre database. For each T1aEL patient, the preoperative computed tomography angiography (CTA), first postoperative CTA, and pre-endoleak CTA were analysed. T1aEL patients were matched 1:1 to uncomplicated controls, based on endograft type and follow-up duration. Anatomical characteristics and endograft dimensions, including the post-EVAR SAL, were measured. Included were 28 patients with a late T1aEL and 28 matched controls. The SAL decreased from 11.2 mm (5.6-20.6 mm) to 3.9 mm (0.0-11.4 mm) in the T1aEL group (p = 0.006), whereas an increase in SAL was seen in the control group from 21.3 mm (14.1-25.8 mm) to 25.4 mm (19.0-36.2 mm; p = 0.015). On the pre-endoleak CTA, 18 patients (64%) in the T1aEL group had a SAL < 10 mm, and one (4%) patient in the control group had a SAL < 10 mm on the matched CTAs. Moreover, three mechanisms of decreasing sealing zone were identified, which might be used to determine optimal imaging or reintervention strategies. Diminishing SAL < 10 mm is an indicator for T1aEL during follow-up, it is imperative to include apposition analysis during follow-up.

13.
J Vasc Surg ; 78(4): 995-1002, 2023 10.
Article in English | MEDLINE | ID: mdl-37257670

ABSTRACT

OBJECTIVE: Carotid endarterectomy (CEA) aims to reduce the risk of stroke in patients with atherosclerotic carotid disease. Preoperative risk assessments that predict complications are needed to optimize the care in this patient group. The current approach, namely relying solely on symptomatology and degree of stenosis, is outdated and calls for innovation. The Agatston calcium score was applied in several vascular specialties to assess cardiovascular risk profile but has been little studied in carotid surgery. It is hypothesized that a higher calcium burden at initial presentation equates to a worse prognosis attributable to an increased cerebrovascular and cardiovascular risk profile. The aim was to investigate the association between preoperative ipsilateral calcium score and postoperative all-cause mortality in patients undergoing CEA. METHODS: This single-center retrospective cohort study included 89 patients who underwent CEA at a tertiary referral center between 2010 and 2018. Preoperative calcium scores were measured on contrast-enhanced computed tomography images with patient-specific Hounsfield thresholds at the level of the carotid bifurcation. The association between these calcium scores and all-cause mortality was analyzed using multivariable adjusted Cox proportional hazard analysis. RESULTS: Cox proportional hazard analysis demonstrated a significant association between preoperative ipsilateral carotid calcium score and all-cause mortality (hazard ratio, 1.10; 95% confidence interval, 1.03-1.16; P = .003). After adjusting for age, preoperative estimated glomerular filtration rate, and diabetes mellitus, a significant association remained (hazard ratio, 1.07; 95% confidence interval, 1.00-1.15; P = .05). CONCLUSIONS: A higher calcium burden was predictive of worse outcome, which might be explained by an overall poorer health status. These results highlight the potential of calcium measurements in combination with other traditional risk factors, for preoperative risk assessment and thus for improved patient education and care.


Subject(s)
Carotid Stenosis , Endarterectomy, Carotid , Stroke , Humans , Endarterectomy, Carotid/adverse effects , Carotid Stenosis/complications , Carotid Stenosis/diagnostic imaging , Carotid Stenosis/surgery , Calcium , Computed Tomography Angiography/adverse effects , Retrospective Studies , Treatment Outcome , Stroke/etiology , Risk Factors , Risk Assessment
14.
J Vasc Res ; 60(1): 1-11, 2023.
Article in English | MEDLINE | ID: mdl-36882023

ABSTRACT

Endovascular revascularization is the preferred treatment for peripheral arterial disease. Restenosis often occurs as a response to procedure-induced arterial damage. Reducing vascular injury during endovascular revascularization may improve its success rate. This study developed and validated an ex vivo flow model using porcine iliac arteries, obtained from a local abattoir. Twenty arteries (of 10 pigs) were equally allocated to two groups: a mock-treated control group and an endovascular intervention group. Arteries of both groups were perfused with porcine blood for 9 min, including 3 min of balloon angioplasty in the intervention group. Vessel injury was assessed by calculating the presence of endothelial cell denudation, vasomotor function, and histopathological analysis. MR imaging displayed balloon positioning and inflation. Endothelial cell staining showed 76% of denudation after ballooning compared to 6% in the control group (p < 0.001). This was confirmed by histopathological analysis, showing a significantly reduced endothelial nuclei count after ballooning compared to the controls (median: 22 vs. 37 nuclei/mm, p = 0.022). In the intervention group, vasoconstriction and endothelium-dependent relaxation were significantly reduced (p < 0.05).We present an ex vivo flow model to test the effects of endovascular therapy on the vessel's wall morphology, endothelial denudation, and endothelial-dependent vasomotor function under physiological conditions. Additionally, it allows the future testing of human arterial tissue.


Subject(s)
Angioplasty, Balloon, Coronary , Angioplasty, Balloon , Humans , Swine , Animals , Angioplasty, Balloon, Coronary/methods , Angioplasty, Balloon/adverse effects , Magnetic Resonance Imaging , Vasoconstriction/physiology , Iliac Artery/diagnostic imaging , Iliac Artery/surgery
16.
J Cardiovasc Surg (Torino) ; 64(2): 134-141, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36987816

ABSTRACT

BACKGROUND: For descending thoracic aortic aneurysms (TAA) in proximity of the aortic arch, debranching of the left subclavian artery (LSA) may be necessary to extend proximal sealing in zone 2. The aim of this study was to determine the added proximal apposition length gained from LSA debranching during thoracic endovascular aortic repair (TEVAR). METHODS: This multicenter retrospective study (2010-2020) included patients who underwent elective TEVAR in zone 2 for a degenerative TAA where the LSA was surgically debranched. The endograft position on the first postoperative computed tomography angiography (CTA) scan was assessed using post-processing software. The analysis included the shortest apposition length (SAL), the tilt of the proximal edge of the endograft, and the distance between the endograft and the left common carotid artery. Clinical endpoints (neurological complications and endoleaks) at 30 days were also reported. RESULTS: Twenty-two patients were included. The median interval between TEVAR and the first postoperative CTA was 3 days (2-10 days). Median SAL was 9.2 mm (1.3-26.4 mm), of which 8.6 mm (1.3-16.2 mm) was gained proximal of the LSA, including the LSA orifice. In 12 patients (55.5%) the SAL was <10 mm. The median tilt was 18.3° (13.9°-22.2°). Seven endoleaks were reported on the first CTA: 1 type Ia, 2 type Ib, 3 type II, and 1 type III. CONCLUSIONS: Debranching the LSA adds valuable sealing length in zone 2, but the SAL was still relatively short in many patients, putting these patients at risk for a future type Ia endoleak. Accurate assessment of the circumferential apposition on postoperative CTA follow-up in these high-risk patients with short, complex landing zones seems mandatory. Evaluation of apposition in a larger population with longer follow-up is advised.


Subject(s)
Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Endovascular Aneurysm Repair , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery , Subclavian Artery/diagnostic imaging , Subclavian Artery/surgery , Retrospective Studies , Treatment Outcome , Aortography/methods , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/complications
17.
J Cardiovasc Surg (Torino) ; 64(2): 159-166, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36897206

ABSTRACT

BACKGROUND: Literature is scarce on the course of iliac endograft limb apposition after endovascular aortic aneurysm repair (EVAR), which is why this study was conducted. METHODS: A retrospective observational imaging study was performed to measure iliac apposition of endograft limbs on the first post-EVAR computed tomography angiography (CTA) scan and on the latest available follow-up CTA scan. With center lumen line reconstructions and CT-applied dedicated software, the shortest apposition length (SAL) of the endograft limbs was assessed as well as the distance between the end of the fabric and the proximal border of the internal iliac artery or the endograft-internal artery distance (EID). RESULTS: Ninety-two iliac endograft limbs were eligible for measurements, with a median follow-up of 3.3 years. At the first post-EVAR CTA, the mean SAL was 31.9±15.6 mm, and the mean EID was 19.5±11.8. At the last follow-up CTA, there was a significant decrease in apposition of 10.5±14.1 mm (P<0.001) and a significant increase in EID of 5.3±9.5 mm (P<0.001). A type Ib endoleak developed in three patients due to a reduced SAL. The apposition was <10 mm in 24% of limbs at the last follow-up vs. 3% at the first post-EVAR CTA. CONCLUSIONS: This retrospective study documented a significant decrease in post-EVAR iliac apposition over time, partly due to retraction of iliac endograft limbs at mid-term CTA follow-up. Further research is required to identify whether regular determination of iliac apposition may predict and prevent type IB endoleaks.


Subject(s)
Aortic Aneurysm, Abdominal , Aortic Aneurysm , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Aortic Aneurysm/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endoleak/diagnostic imaging , Endoleak/etiology , Endovascular Procedures/adverse effects , Retrospective Studies , Treatment Outcome
18.
J Cardiovasc Surg (Torino) ; 64(2): 142-149, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36897207

ABSTRACT

BACKGROUND: Fenestrated endovascular aortic aneurysm repair (FEVAR) is used in pararenal abdominal aortic aneurysms to achieve a durable proximal seal. This study investigated the mid-term course of the proximal fenestrated stent graft (FSG) sealing zone on the first and latest available post-FEVAR computed tomographic angiography (CTA) scan in a single-center series. METHODS: In 61 elective FEVAR patients, the shortest length of circumferential apposition between the FSG and the aortic wall (shortest apposition length [SAL]) was retrospectively assessed on the first and last available postoperative CTA scans. Patient records were reviewed for FEVAR-related procedural details, complications, and reinterventions. RESULTS: The median (interquartile range) time between the FEVAR procedure and the first and last CTA scan was 35 (30-48) days and 2.6 (1.2-4.3) years, respectively. The median (interquartile range) SAL was 38 (29-48) mm, and 44 (34-59) mm on the first and last CTA scans, respectively. During follow-up, the SAL increased >5 mm in 32 patients (52%), and decreased >5 mm in six patients (10%). Reintervention was performed for a type 1a endoleak in one patient. Twelve other patients needed 17 reinterventions for other FEVAR-related complications. CONCLUSIONS: Good mid-term apposition of the FSG in the pararenal aorta was achieved post-FEVAR, and the occurrence of type 1a endoleaks was low. The number of reinterventions was substantial, however, but for reasons other than loss of proximal seal.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Stents/adverse effects , Retrospective Studies , Treatment Outcome , Endovascular Procedures/adverse effects , Aorta/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/surgery
19.
J Cardiovasc Surg (Torino) ; 64(2): 150-158, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36897208

ABSTRACT

BACKGROUND: The GORE EXCLUDER Conformable Endoprosthesis with active control (CEXC) was developed to treat challenging aortic neck anatomy. This study investigated the clinical results and changes in endograft (ap)position during follow-up. METHODS: Patients treated with the CEXC between 2018 and 2022 were included in this prospective single-center study. Computed tomography angiography (CTA) follow-up was grouped into three categories: 0 to 6 (FU1), 7 to 18 (FU2), and 19 to 30 (FU3) months. Clinical end points were endograft-associated complications and reinterventions. CTA analysis included the shortest apposition length (SAL) between the endograft fabric and the first slice where circumferential apposition was lost, shortest fabric distance (SFD) between both renal arteries and the endograft fabric, and maximum infrarenal and suprarenal aortic curvature. FU2 and FU3 were compared with FU1 to establish changes. RESULTS: Included were 46 patients, of whom 36 (78%) had at least one hostile neck feature and 13 (28%) were treated outside instructions for use. Technical success was 100%. Median CTA follow-up was 10 months (2-20 months); 39 patients had a CTA available at FU1, 22 at FU2, and 12 at FU3. At FU1, the median SAL was 21.4 mm (13.2-27.4 mm), which did not significantly change during follow-up. No type I endoleaks, and one type III endoleak at an IBD occurred during follow-up. Two cases of endograft migration (SFD increase >10 mm) were seen during follow-up (one treated outside the instructions for use). Maximum infrarenal and suprarenal aortic curvature did not significantly change during follow-up. CONCLUSIONS: The use of the CEXC in challenging aortic necks enables stable apposition without significant changes in aortic morphology at short-term follow-up.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Aneurysm Repair , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/complications , Prospective Studies , Endovascular Procedures/adverse effects , Treatment Outcome , Endoleak/diagnostic imaging , Endoleak/etiology , Retrospective Studies , Prosthesis Design
20.
J Endovasc Ther ; : 15266028221149913, 2023 Jan 16.
Article in English | MEDLINE | ID: mdl-36647185

ABSTRACT

PURPOSE: Hostile aortic neck characteristics, including short length, severe suprarenal and infrarenal angulation, conicity, and large diameter, have been associated with increased risk for type Ia endoleak (T1aEL) after endovascular aneurysm repair (EVAR). This study investigates the mid-term discriminative ability of a statistical shape model (SSM) of the infrarenal aortic neck morphology compared with or in combination with conventional measurements in patients who developed T1aEL post-EVAR. MATERIALS AND METHODS: The dataset composed of EVAR patients who developed a T1aEL during follow-up and a control group without T1aEL. Principal component (PC) analysis was performed using a parametrization to create an SSM. Three logistic regression models were created. To discriminate between patients with and without T1aEL, sensitivity, specificity, and the area under the receiver operating characteristic (ROC) curve (AUC) were calculated. RESULTS: In total, 126 patients (84% male) were included. Median follow-up time in T1aEl group and control group was 52 (31, 78.5) and 51 (40, 62.5) months, respectively. Median follow-up time was not statistically different between the groups (p=0.72). A statistically significant difference between the median PC scores of the T1aEL and control groups was found for the first, eighth, and ninth PC. Sensitivity, specificity, and AUC values for the SSM-based versus the conventional measurements-based logistic regression models were 79%, 70%, and 0.82 versus 74%, 73%, and 0.85, respectively. The model of the SSM and conventional measurements combined resulted in sensitivity, specificity, and AUC of 81%, 81%, and 0.92. CONCLUSION: An SSM of the infrarenal aortic neck determines its 3-dimensional geometry. The SSM is a potential valuable tool for risk stratification and T1aEL prediction in EVAR. The SSM complements the conventional measurements of the individual preoperative infrarenal aortic neck geometry by increasing the predictive value for late type Ia endoleak after standard EVAR. CLINICAL IMPACT: A statistical shape model (SSM) determines the 3-dimensional geometry of the infrarenal aortic neck. The SSM complements the conventional measurements of the individual pre-operative infrarenal aortic neck geometry by increasing the predictive value for late type Ia endoleaks post-EVAR. The SSM is a potential valuable tool for risk stratification and late T1aEL prediction in EVAR and it is a first step toward implementation of a treatment planning support tool in daily clinical practice.

SELECTION OF CITATIONS