Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 107
Filter
1.
PLoS One ; 19(5): e0303776, 2024.
Article in English | MEDLINE | ID: mdl-38722867

ABSTRACT

[This corrects the article DOI: 10.1371/journal.pone.0278460.].

2.
Mob DNA ; 15(1): 10, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711146

ABSTRACT

BACKGROUND: The advancement of sequencing technologies results in the rapid release of hundreds of new genome assemblies a year providing unprecedented resources for the study of genome evolution. Within this context, the significance of in-depth analyses of repetitive elements, transposable elements (TEs) in particular, is increasingly recognized in understanding genome evolution. Despite the plethora of available bioinformatic tools for identifying and annotating TEs, the phylogenetic distance of the target species from a curated and classified database of repetitive element sequences constrains any automated annotation effort. Moreover, manual curation of raw repeat libraries is deemed essential due to the frequent incompleteness of automatically generated consensus sequences. RESULTS: Here, we present an example of a crowd-sourcing effort aimed at curating and annotating TE libraries of two non-model species built around a collaborative, peer-reviewed teaching process. Manual curation and classification are time-consuming processes that offer limited short-term academic rewards and are typically confined to a few research groups where methods are taught through hands-on experience. Crowd-sourcing efforts could therefore offer a significant opportunity to bridge the gap between learning the methods of curation effectively and empowering the scientific community with high-quality, reusable repeat libraries. CONCLUSIONS: The collaborative manual curation of TEs from two tardigrade species, for which there were no TE libraries available, resulted in the successful characterization of hundreds of new and diverse TEs in a reasonable time frame. Our crowd-sourcing setting can be used as a teaching reference guide for similar projects: A hidden treasure awaits discovery within non-model organisms.

3.
Wien Klin Wochenschr ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38743140

ABSTRACT

BACKGROUND: The Broström procedure is an established procedure in cases of primary lateral ankle ligament repair (LALR). To improve postoperative stability an augmentation device, InternalBrace™ (Arthrex, Naples, FL) has been introduced. This study evaluates remodelling of the anterior talofibular ligament (ATFL) in patients undergoing a tape augmented Broström technique as well as clinical outcomes. METHODS: In this study 32 patients with chronic lateral ankle instability (CLAI) receiving augmented LALR were included. Clinical outcomes were evaluated at a one-time postoperative visit between 12 and 18 months. A 3 T magnetic resonance imaging (MRI) was done to evaluate the morphology of the ATFL. Statistical analysis was completed with the free software and environment R version 3.6.3 (Bell Laboratories, Murray Hill, NJ, USA) and P-values < 0.05 were considered statistically significant. RESULTS: The mean follow-up time was 15.3 ± 1.8 months with a return to sport time of 4.0 ± 2.4 months. The average AOFAS (American Orthopaedic Foot and Ankle Society Score) score was 94.4 ± 7.2, the FAOS (Foot and Ankle Outcome Score) demonstrated 87.3 ± 10.4 points and the FFI (Foot Function Index - 2 scores (pain and function score)) was 22.9 ± 20.1 and 15.4 ± 10.4, respectively. The MRI findings demonstrated an average length of the ATFL of 18.6 ± 4.3 mm and the width was 3.6 ± 0.9 mm. A clear differentiation between the ATFL and the augmentation device could be shown in 28 cases. The Fisher's exact test could not depict a significant correlation between the presence of a bone marrow edema and the tension of the augmentation device with a level of significance of α = 0.05. CONCLUSION: An anatomical healing tendency of the ligament repair and good integrity of the augmentation device could be shown based on MRI findings. The lateral ligament repair augmented with suture tape is an effective and safe procedure regarding surgical treatment in chronic lateral ankle instability producing good clinical outcome.

4.
Diagnostics (Basel) ; 14(7)2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38611632

ABSTRACT

In the early diagnostic workup of acute pancreatitis (AP), the role of contrast-enhanced CT is to establish the diagnosis in uncertain cases, assess severity, and detect potential complications like necrosis, fluid collections, bleeding or portal vein thrombosis. The value of texture analysis/radiomics of medical images has rapidly increased during the past decade, and the main focus has been on oncological imaging and tumor classification. Previous studies assessed the value of radiomics for differentiating between malignancies and inflammatory diseases of the pancreas as well as for prediction of AP severity. The aim of our study was to evaluate an automatic machine learning model for AP detection using radiomics analysis. Patients with abdominal pain and contrast-enhanced CT of the abdomen in an emergency setting were retrospectively included in this single-center study. The pancreas was automatically segmented using TotalSegmentator and radiomics features were extracted using PyRadiomics. We performed unsupervised hierarchical clustering and applied the random-forest based Boruta model to select the most important radiomics features. Important features and lipase levels were included in a logistic regression model with AP as the dependent variable. The model was established in a training cohort using fivefold cross-validation and applied to the test cohort (80/20 split). From a total of 1012 patients, 137 patients with AP and 138 patients without AP were included in the final study cohort. Feature selection confirmed 28 important features (mainly shape and first-order features) for the differentiation between AP and controls. The logistic regression model showed excellent diagnostic accuracy of radiomics features for the detection of AP, with an area under the curve (AUC) of 0.932. Using lipase levels only, an AUC of 0.946 was observed. Using both radiomics features and lipase levels, we showed an excellent AUC of 0.933 for the detection of AP. Automated segmentation of the pancreas and consecutive radiomics analysis almost achieved the high diagnostic accuracy of lipase levels, a well-established predictor of AP, and might be considered an additional diagnostic tool in unclear cases. This study provides scientific evidence that automated image analysis of the pancreas achieves comparable diagnostic accuracy to lipase levels and might therefore be used in the future in the rapidly growing era of AI-based image analysis.

5.
J Pers Med ; 14(4)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38672979

ABSTRACT

Addressing non-unions involves stabilizing the affected area through osteosynthesis and improving bone biology using bone grafts. However, there is no consensus on the optimal treatment method. This study aims to compare outcomes of non-union surgery using conventional treatment methods (metal hardware ± graft) versus osteosynthesis with the human allogeneic cortical bone screw (Shark Screw®) alone or in combination with a metallic plate. Thirty-four patients underwent conventional treatment, while twenty-eight cases received one or more Shark Screws®. Patient demographics, bone healing, time to bone healing, and complications were assessed. Results revealed a healing rate of 96.4% for the Shark Screw® group, compared to 82.3% for the conventionally treated group. The Shark Screw® group exhibited a tendency for faster bone healing (9.4 ± 3.2 vs. 12.9 ± 8.5 weeks, p = 0.05061). Hardware irritations led to six metal removals in the conventional group versus two in the Shark Screw® group. The Shark Screw® emerges as a promising option for personalized non-union treatment in the foot, ankle, and select lower leg cases, facilitating effective osteosynthesis and grafting within a single construct and promoting high union rates, low complications, and a rapid healing process.

6.
Eur Radiol ; 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38480567

ABSTRACT

OBJECTIVES: Aim of this study was to assess the value of virtual non-contrast (VNC) reconstructions in differentiating between adrenal adenomas and metastases on a photon-counting detector CT (PCD-CT). MATERIAL AND METHODS: Patients with adrenal masses and contrast-enhanced CT scans in portal venous phase were included. Image reconstructions were performed, including conventional VNC (VNCConv) and PureCalcium VNC (VNCPC), as well as virtual monochromatic images (VMI, 40-90 keV) and iodine maps. We analyzed images using semi-automatic segmentation of adrenal lesions and extracted quantitative data. Logistic regression models, non-parametric tests, Bland-Altman plots, and a random forest classifier were used for statistical analyses. RESULTS: The final study cohort consisted of 90 patients (36 female, mean age 67.8 years [range 39-87]) with adrenal lesions (45 adenomas, 45 metastases). Compared to metastases, adrenal adenomas showed significantly lower CT-values in VNCConv and VNCPC (p = 0.007). Mean difference between VNC and true non-contrast (TNC) was 17.67 for VNCConv and 14.85 for VNCPC. Random forest classifier and logistic regression models both identified VNCConv and VNCPC as the best discriminators. When using 26 HU as the threshold in VNCConv reconstructions, adenomas could be discriminated from metastases with a sensitivity of 86.7% and a specificity of 75.6%. CONCLUSION: VNC algorithms overestimate CT values compared to TNC in the assessment of adrenal lesions. However, they allow a reliable discrimination between adrenal adenomas and metastases and could be used in clinical routine in near future with an increased threshold (e.g., 26 HU). Further (multi-center) studies with larger patient cohorts and standardized protocols are required. CLINICAL RELEVANCE STATEMENT: VNC reconstructions overestimate CT values compared to TNC. Using a different threshold (e.g., 26 HU compared to the established 10 HU), VNC has a high diagnostic accuracy for the discrimination between adrenal adenomas and metastases. KEY POINTS: • Virtual non-contrast reconstructions may be promising tools to differentiate adrenal lesions and might save further diagnostic tests. • The conventional and a new calcium-preserving virtual non-contrast algorithm tend to systematically overestimate CT-values compared to true non-contrast images. • Therefore, increasing the established threshold for true non-contrast images (e.g., 10HU) may help to differentiate between adrenal adenomas and metastases on contrast-enhanced CT.

7.
Radiol Med ; 129(3): 401-410, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38319495

ABSTRACT

PURPOSE: To assess the reliability of virtual non-contrast (VNC) derived coronary artery calcium quantities in relation to heart rate and the VNC algorithm used compared to reference true non-contrast (TNC), considering several clinically established acquisition modes. MATERIAL AND METHODS: An ad hoc built coronary phantom containing four calcified lesions and an iodinated lumen was scanned using three cardiac acquisition modes three times within an anthropomorphic cardiac motion phantom simulating different heart rates (0, 60, 80, 100 bpm) and reconstructed with a conventional (VNCconv) and a calcium-sensitive (VNCpc) VNC algorithm. TNC reference was scanned at 0 bpm with non-iodinated lumen. Calcium scores were assessed in terms of number of lesions detected, Agatston and volume scores and global noise was measured. Paired t-test and Wilcoxon test were performed to test measurements for significant difference. RESULTS: For both VNC algorithms used, calcium levels or noise were not significantly affected by heart rate. Measurements on VNCpc reconstructions best reproduced TNC results, but with increased variability (Agatston scores at 0 bpm for TNC, VNCconv, and VNCpc were 47.1 ± 1.1, 6.7 ± 2.8 (p < 0.001), and 45.3 ± 7.6 (p > 0.05), respectively). VNC reconstructions showed lower noise levels compared to TNC, especially for VNCpc (noiseheart on TNC, VNCconv and VNCpc at 0 bpm was 5.0 ± 0.4, 4.5 ± 0.2, 4.2 ± 0.2). CONCLUSION: No significant heart rate dependence of VNC-based calcium scores was observed in an intra-reconstruction comparison. VNCpc reproduces TNC scores better than VNCconv without significant differences and decreased noise, however, with an increasing average deviation with rising heart rates. VNC-based CACS should be used with caution as the measures show higher variability compared to reference TNC and therefore hold the potential of incorrect risk categorization.


Subject(s)
Calcium , Tomography, X-Ray Computed , Humans , Heart Rate , Reproducibility of Results , Tomography, X-Ray Computed/methods , Thorax
8.
Int J Cardiovasc Imaging ; 40(4): 723-732, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38175389

ABSTRACT

The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNCconv) and a calcium-preserving (VNCpc) algorithm. Noise was analyzed by means of the standard deviation of CT-values within the left ventricle. To assess the effectiveness of contrast media removal, heart volumes were segmented and the proportion of their histograms > 130HU was taken. AVC was measured by Agatston and volume score. 41 patients were included. Comparable noise levels to TNC were achieved with all VNC reconstructions. Contrast media was effectively virtually removed (proportions > 130HU from 81% to < 1%). Median calcium scores derived from VNCconv underestimated TNC-based scores (up to 74%). Results with smallest absolute difference to TNC were obtained with VNCpc reconstructions (0.4 mm, Br36, QIR 4), but with persistent significant underestimation (median 29%). Both VNC algorithms showed near-perfect (r²>0.9) correlation with TNC. Thin-slice VNC reconstructions provide equivalent noise levels to standard thick-slice TNC series and effective virtual removal of iodinated contrast. AVC scoring was feasible on both VNC series, showing near-perfect correlation, but with significant underestimation. VNCpc with 0.4 mm slices and Br36 kernel at QIR 4 gave the most comparable results and, with further advances, could be a promising replacement for additional TNC.


Subject(s)
Algorithms , Aortic Valve Stenosis , Aortic Valve , Aortic Valve/pathology , Calcinosis , Computed Tomography Angiography , Multidetector Computed Tomography , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Female , Aged , Male , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Reproducibility of Results , Transcatheter Aortic Valve Replacement/instrumentation , Calcinosis/diagnostic imaging , Contrast Media/administration & dosage
9.
AJNR Am J Neuroradiol ; 45(2): 183-187, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38164551

ABSTRACT

In this anthropomorphic head phantom study, samples containing blood and contrast agent with concentrations ranging from 0 to 6 mg iodine per milliliter and another set of samples without blood for reference were scanned with a photon-counting detector CT using a standard cranial protocol. It was demonstrated that photon-counting detector CT can reliably distinguish hemorrhage and contrast media, including density determination of the latter. The technology promises to add value in several neuroimaging applications.


Subject(s)
Contrast Media , Iodine , Humans , Photons , Tomography, X-Ray Computed/methods , Hemorrhage , Phantoms, Imaging
11.
Abdom Radiol (NY) ; 49(1): 103-116, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37796327

ABSTRACT

PURPOSE: To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT). METHODS: Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40-190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV). RESULTS: Thirty-eight patients (mean age 70.4 years ± 10.3 [range 45-91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (≤ 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (≤ 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT. CONCLUSION: PCD-CT VMI reconstructions (≤ 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Radiography, Dual-Energy Scanned Projection , Male , Humans , Aged , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods , Pancreatic Neoplasms/diagnostic imaging , Carcinoma, Pancreatic Ductal/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods
12.
Colorectal Dis ; 26(2): 335-347, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38115093

ABSTRACT

AIM: The aims of this study were to analyse all hospitalizations for acute diverticulitis in Germany from 2010 to 2021 and to assess the effects of the first 2 years of the SARS-CoV-2 pandemic on hospitalizations for acute diverticulitis. METHOD: Using data from the German Federal Statistical Office, we analysed fully anonymized healthcare data of hospitalizations and treatment regimens with acute diverticulitis as the main diagnosis between 2010 and 2021. Logistic regression analyses for in-hospital mortality were performed. RESULTS: A total of 608,162 hospitalizations were included. While the number of hospitalizations constantly increased until 2019 (+52.4%), a relative decrease of 10.1% was observed between 2019 and 2020, followed by stable numbers of hospitalizations in 2021 (+1.1% compared with 2020). In-hospital mortality showed a relative decrease of 33.2% until 2019 and thereafter a relative increase of 26.9% in 2020 and of 7.5% in 2021. A 21.6% and a 19.3% drop in hospitalizations was observed during the first and second waves of the SARS-CoV-2 pandemic, mostly affecting hospitalizations for uncomplicated diverticulitis, with a corresponding 11.6% and 16.8% increase in admissions for complicated diverticulitis. Multivariable logistic regression analyses showed significantly higher in-hospital mortality for hospitalizations in which surgery (OR = 2.76) and CT (OR = 1.32) were given, as well as lower mortality for women (OR = 0.88), whereas percutaneous drainage was not associated with higher in-hospital mortality compared with conservative treatment (OR = 0.71). CONCLUSION: This study points out the long-term trends in inpatient treatment for acute diverticulitis and the in-hospital mortality risk factors of patients hospitalized for acute diverticulitis in a large nationwide cohort, as well as changes in these trends and factors resulting from the SARS-CoV-2 pandemic. These changes might be attributable to delayed diagnosis and thus more severe stages of disease as a result of containment measures.


Subject(s)
COVID-19 , Diverticulitis , Humans , Female , SARS-CoV-2 , Pandemics , Inpatients , COVID-19/epidemiology , Diverticulitis/therapy , Hospitalization , Retrospective Studies
13.
Diagnostics (Basel) ; 13(22)2023 Nov 08.
Article in English | MEDLINE | ID: mdl-37998539

ABSTRACT

In photon-counting detector CT (PCD-CT), coronary artery calcium scoring (CACS) can be performed using virtual non-contrast (VNC) series derived from coronary CT angiography (CCTA) datasets. Our study analyzed image characteristics of VNC series in terms of the efficacy of virtual iodine "removal" and image noise to determine whether the prerequisites for calcium quantification were satisfied. We analyzed 38 patients who had undergone non-enhanced CT followed by CCTA on a PCD-CT. VNC reconstructions were performed at different settings and algorithms (conventional VNCConv; PureCalcium VNCPC). Virtual iodine "removal" was investigated by comparing histograms of heart volumes. Noise was assessed within the left ventricular cavity. Calcium was quantified on the true non-contrast (TNC) and all VNC series. The histograms were comparable for TNC and all VNC. Image noise between TNC and all VNC differed slightly but significantly. VNCConv CACS showed a significant underestimation regardless of the reconstruction setting, while VNCPC CACS were comparable to TNC. Correlations between TNC and VNC were excellent, with a higher predictive accuracy for VNCPC. In conclusion, the iodine contrast can be effectively subtracted from CCTA datasets. The remaining VNC series satisfy the requirements for CACS, yielding results with excellent correlation compared to TNC-based CACS and high predicting accuracy.

14.
Cardiovasc Intervent Radiol ; 46(10): 1385-1393, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37700006

ABSTRACT

PURPOSE: To investigate differences in thermal sensitivity of virtual monoenergetic imaging (VMI) series generated from photon-counting detector (PCD) CT data sets, regarding their use to improve discrimination of the ablation zone during percutaneous cryoablation. MATERIALS AND METHODS: CT-guided cryoablation was performed using an ex vivo model of porcine liver on a PCD-CT system. The ablation zone was imaged continuously for 8 min by acquiring a CT scan every 5 s. Tissue temperature was measured using fiberoptic temperature probes placed parallel to the cryoprobe. CT-values and noise were measured at the tip of the temperature probes on each scan and on VMI series from 40 to 130 keV. Correlation of CT-values and temperature was assessed using linear regression analyses. RESULTS: For the whole temperature range of [- 40, + 20] °C, we observed a linear correlation between CT-values and temperature in reference 70 keV images (R2 = 0.60, p < 0.001) with a thermal sensitivity of 1.4HU/°C. For the most dynamic range of [- 15, + 20] °C, the sensitivity increased to 2.4HU/°C (R2 = 0.50, p < 0.001). Using VMI reconstructions, the thermal sensitivity increased from 1.4 HU/°C at 70 keV to 1.5, 1.7 and 2.0HU/°C at 60, 50 and 40 keV, respectively (range [- 40, + 20] °C). For [- 15, + 20]°C, the thermal sensitivity increased from 2.4HU/°C at 70 keV to 2.5, 2.6 and 2.7HU/°C at 60, 50 and 40 keV, respectively. Both CT-values and noise also increased with decreasing VMI keV-levels. CONCLUSION: During CT-guided cryoablation of porcine liver, low-keV VMI reconstructions derived from PCD-CT data sets exhibit improved thermal sensitivity being highest between + 20 and - 15 °C.


Subject(s)
Cryosurgery , Swine , Animals , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods , Liver/diagnostic imaging , Liver/surgery , Abdomen , Retrospective Studies , Radiographic Image Interpretation, Computer-Assisted/methods
15.
CVIR Endovasc ; 6(1): 44, 2023 Aug 29.
Article in English | MEDLINE | ID: mdl-37642825

ABSTRACT

PURPOSE: Aim of this study was to analyze hospitalizations due to ruptured and non-ruptured abdominal aortic aneurysms (rAAA, nrAAA) in Germany between 2005 and 2021 to determine long-term trends in treatment and the impact of the SARS-CoV-2 pandemic. MATERIALS AND METHODS: Fully anonymized data were available from the research data center (RDC) of the German Federal Statistical Office (Destatis). All German hospitalizations with the ICD-10 code "I71.3, rAAA" and "I71.4, nrAAA" in 2005 and 2010-2021 were analyzed. RESULTS: We report data of a total of 202,951 hospitalizations. The number of hospitalizations increased from 2005 to 2019 (14,075 to 16,051, + 14.0%). The rate of open repair (OR) constantly decreased, whereas the rate of endovascular aortic repair (EVAR) increased until 2019. During the pandemic, the number of hospitalizations due to nrAAA dropped from 13,887 (86.5%) in 2019 to 11,278 (85.0%) in 2021. The strongest decrease of hospitalizations for AAA was observed during the first wave of the SARS-CoV-2-pandemic in spring 2020 (-25.5%). CONCLUSION: Over the past decades, we observed an increasing number of hospitalizations due to AAA accompanied by a shift from OR to EVAR especially for nrAAA. During the lockdown measures due to the SARS-CoV-2-pandemic, a decrease in hospitalizations for nrAAA (but not for rAAA) was shown in 2020 and furthermore in 2021 with no rebound of treatment of nrAAA suggesting an accumulation of untreated AAA with a potentially increased risk of rupture.

16.
Eur J Radiol ; 165: 110946, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37399668

ABSTRACT

PURPOSE: To investigate the usefulness of virtual monoenergetic image (VMI) reconstructions derived from scans on a novel photon-counting detector CT (PCD-CT) for artifact reduction in patients after posterior spinal fixation. METHODS: This retrospective cohort study included 23 patients status post posterior spinal fixation. Subjects were scanned on a novel PCD-CT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) as part of routine clinical care. 14 sets of VMI reconstructions were derived in 10 keV increments for the interval 60-190 keV. The mean and the standard deviation (SD) of CT-values in 12 defined locations around a pair of pedicle screws on one vertebral level and the SD of homogenous fat were measured and used to calculate an artifact index (AIx). RESULTS: Averaged over all regions, the lowest AIx was observed at VMI levels of 110 keV (32.5 (27.8-37.9)) which was significantly different from those of VMIs ≤ 90 keV (p < 0.001) or ≥160 keV (p < 0.015), respectively. Overall AIx values increased in both lower- and higher-keV levels. Regarding individual locations, either a monotonous AIx-decrease for increasing keV values or an AIx-minimum in intermediate-keV levels (100-140 keV) was found. In locations adjacent to larger metal parts, the increase of AIx values at the high-end of the keV spectrum was mainly explained by a reappearance of streak artifacts. CONCLUSION: Our findings suggest that 110 keV is the optimal VMI setting for overall artifact suppression. In specific anatomical regions, however, slight adjustments towards higher-keV levels may provide better results.


Subject(s)
Artifacts , Tomography, X-Ray Computed , Humans , Retrospective Studies , Tomography, X-Ray Computed/methods , Spine/diagnostic imaging , Spine/surgery , Metals , Radiographic Image Interpretation, Computer-Assisted/methods , Signal-To-Noise Ratio
17.
Eur Radiol ; 33(12): 8528-8539, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37488295

ABSTRACT

OBJECTIVES: Virtual monoenergetic images (VMIs) from photon-counting CT (PCCT) may change quantitative coronary plaque volumes. We aimed to assess how plaque component volumes change with respect to VMIs. METHODS: Coronary CT angiography (CTA) images were acquired using a dual-source PCCT and VMIs were reconstructed between 40 and 180 keV in 10-keV increments. Polychromatic images at 120 kVp (T3D) were used as reference. Quantitative plaque analysis was performed on T3D images and segmentation masks were copied to VMI reconstructions. Calcified plaque (CP; > 350 Hounsfield units, HU), non-calcified plaque (NCP; 30 to 350 HU), and low-attenuation NCP (LAP; - 100 to 30 HU) volumes were calculated using fixed thresholds. RESULTS: We analyzed 51 plaques from 51 patients (67% male, mean age 65 ± 12 years). Average attenuation and contrast-to-noise ratio (CNR) decreased significantly with increasing keV levels, with similar values observed between T3D and 70 keV images (299 ± 209 vs. 303 ± 225 HU, p = 0.15 for mean HU; 15.5 ± 3.7 vs. 15.8 ± 3.5, p = 0.32 for CNR). Mean NCP volume was comparable between T3D and 100-180-keV reconstructions. There was a monotonic decrease in mean CP volume, with a significant difference between all VMIs and T3D (p < 0.05). LAP volume increased with increasing keV levels and all VMIs showed a significant difference compared to T3D, except for 50 keV (28.0 ± 30.8 mm3 and 28.6 ± 30.1 mm3, respectively, p = 0.63). CONCLUSIONS: Estimated coronary plaque volumes significantly differ between VMIs. Normalization protocols are needed to have comparable results between future studies, especially for LAP volume which is currently defined using a fixed HU threshold. CLINICAL RELEVANCE STATEMENT: Different virtual monoenergetic images from photon-counting CT alter attenuation values and therefore corresponding plaque component volumes. New clinical standards and protocols are required to determine the optimal thresholds to derive plaque volumes from photon-counting CT. KEY POINTS: • Utilizing different VMI energy levels from photon-counting CT for the analysis of coronary artery plaques leads to substantial changes in attenuation values and corresponding plaque component volumes. • Low-energy images (40-70 keV) improved contrast-to-noise ratio, however also increased image noise. • Normalization protocols are needed to have comparable results between future studies, especially for low-attenuation plaque volume which is currently defined using a fixed HU threshold.


Subject(s)
Plaque, Atherosclerotic , Radiography, Dual-Energy Scanned Projection , Humans , Male , Middle Aged , Aged , Female , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods , Computed Tomography Angiography/methods , Coronary Angiography/methods , Plaque, Atherosclerotic/diagnostic imaging , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods
18.
Eur J Radiol ; 166: 110967, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37487433

ABSTRACT

PURPOSE: To correlate CT values of the blood pool on VNC series with serum hemoglobin values for the detection of anemia in oncologic patients undergoing contrast-enhanced PCD-CT scans. METHODS: This prospective study (NCT04989192) included consecutive oncologic patients undergoing contrast-enhanced CT on a novel PCD-CT system between 08/2021 and 01/2022. The interval between complete blood count (CBC) and CT scan acquisition had to be no more than seven days. CT-values of the blood pool were measured on 70 keV VMI series (CT-values(BP)70keV) and on VNC series (CT-values(BP)VNC) at five anatomic positions (left atrium, left ventricle, main pulmonary artery, ascending and descending aorta) and averaged per patient. Pearson correlation analyses and ROC analyses were performed to identify relations between CT-values(BP)VNC, CBC parameters, and degrees of anemia as defined by the WHO (no anemia, mild, moderate, severe anemia). RESULTS: A total of 329 patients (age 68 ± 12 years; 200 men) were included. CT-values(BP)VNC showed a strong linear correlation to serum hemoglobin (r2 = 0.80, p <.001) and hematocrit (r2 = 0.76, p <.001) and were significantly different between anemia subgroups in both women and men (ΔHU: 3.5-11.4; all p <.01). ROC analyses yielded high diagnostic performance for the identification of patients without anemia, patients without and with mild anemia, and patients with severe anemia using gender-specific cutoffs for CT-value(BP)VNC (all AUC's > 0.90). CONCLUSIONS: The spectral information inherent in PCD-CT acquisitions allows the detection and quantification of anemia in contrast-enhanced CT acquisitions of oncologic patients with high diagnostic accuracy.


Subject(s)
Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Hemoglobins , Prospective Studies , ROC Curve , Proof of Concept Study
20.
Front Endocrinol (Lausanne) ; 14: 1111104, 2023.
Article in English | MEDLINE | ID: mdl-37033213

ABSTRACT

Background: X-linked hypophosphatemia (OMIM 307800) is a rare bone disease caused by a phosphate-wasting condition with lifelong clinical consequences. Those affected suffer from bone pain, complex skeletal deformities, impaired mobility and a reduced quality of life. Early osteoarthritis and reduced range of motion of the lower limbs are known pathologies in XLH patients. However, XLH-specific data on the affected compartments such as the ankle joint through the evaluation of radiographic and gait analysis data is still lacking. Patients and methods: In this cross-sectional study, patients with genetically verified XLH, age ≥ 16 - 50 years and a complete record of gait analysis and or radiographic analysis data were included. Clinical examination, radiological and gait analysis data were compared to norms using the dataset of our gait laboratory registry. Radiographic analysis included tibial deformity analysis and assessment of osteoarthritis and enthesopathies. Western Ontario and McMaster Universities Arthritis Index (WOMAC), SF36v2, American Orthopedic Foot and Ankle Society score (AOFAS) and the Foot and Ankle Outcome Score (FAOS) were used. Twentythree participants with 46 limbs were eligible for the study. Results: A total of 23 patients (n=46 feet) met the inclusion criteria. Patients with XLH had significantly reduced gait quality, ankle power and plantar flexion (p < 0.001) compared to a historic gait laboratory control group. Ankle valgus deformity was detected in 22 % and ankle varus deformity in 30 % of the patients. The subtalar joint (59.1%) as well as the anterior tibiotalar joint (31.1%) were the main localizations of moderate to severe joint space narrowing. Ankle power was decreased in moderate and severe subtalar joint space narrowing (p < 0.05) compared to normal subtalar joint space narrowing. No lateral or medial ligament instability of the ankle joint was found in clinical examination. Tibial procurvatum deformity led to lower ankle power (p < 0.05). Conclusions: This study showed structural and functional changes of the ankle in patients with XLH. Subtalar ankle osteoarthritis, patient reported outcome scores and clinical ankle restriction resulted in lower gait quality and ankle power.


Subject(s)
Familial Hypophosphatemic Rickets , Osteoarthritis , Humans , Adolescent , Young Adult , Adult , Middle Aged , Ankle Joint/diagnostic imaging , Ankle , Quality of Life , Cross-Sectional Studies , Lower Extremity , Osteoarthritis/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...