Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 126
Filter
1.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38613845

ABSTRACT

OBJECTIVES: Myocardial recovery in children supported by a durable left ventricular assist device is a rare, but highly desirable outcome because it could potentially eliminate the need for a cardiac transplant and the lifelong need for immunosuppressant therapy and the risk of complications. However, experience with this specific outcome is extremely limited. METHODS: All patients < 19 years old supported by a durable left ventricular assist device from the European Registry for Patients with Mechanical Circulatory Support database were included. Participating centres were approached for additional follow-up data after explantation. Associated factors for explantation due to myocardial recovery were explored using Cox proportional hazard models. RESULTS: The incidence of recovery in children supported by a durable left ventricular assist device was 11.7% (52/445; median duration of support, 122.0 days). Multivariable analyses showed body surface area (hazard ratio 0.229; confidence interval 0.093-0.565; P = 0.001) and a primary diagnosis of myocarditis (hazard ratio 4.597; confidence interval 2.545-8.303; P < 0.001) to be associated with recovery. Left ventricular end-diastolic diameter in children with myocarditis was not associated with recovery. Follow-up after recovery was obtained for 46 patients (88.5%). Sustained myocardial recovery was reported in 33/46 (71.7%) at the end of the follow-up period (28/33; >2 year). Transplants were performed in 6/46 (11.4%) (in 5 after a ventricular assist device was reimplanted). Death occurred in 7/46 (15.2%). CONCLUSIONS: Myocardial recovery occurs in a substantial portion of paediatric patients supported with durable left ventricular assist devices, and sustainable recovery is seen in around three-quarters of them. Even children with severely dilated ventricles due to myocarditis can show recovery. Clinicians should be attentive to (developing) myocardial recovery. These results can be used to develop internationally approved paediatric weaning guidelines.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Myocarditis , Humans , Child , Young Adult , Adult , Heart-Assist Devices/adverse effects , Myocarditis/surgery , Myocardium , Diastole , Heart Failure/surgery , Treatment Outcome
2.
Pediatr Transplant ; 28(4): e14770, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38682599

ABSTRACT

BACKGROUND: There is a shortage of donor hearts in Switzerland, especially for pediatric recipients. However, the rate and reason for refusals of pediatric donor hearts offered in Switzerland has not been systematically analyzed. METHODS: The national transplant database, Swiss Organ Allocation System, was searched for all hearts from Swiss and foreign donors younger than 16 years from 2015 to 2020. The numbers of accepted and refused hearts and early outcome were assessed, and the reasons for refusal were retrospectively analyzed. RESULTS: A total of 136 organs were offered to the three Swiss pediatric heart centers and foreign donor procurement organizations. Of these, 26/136 (19%) organs were accepted and transplanted: 18 hearts were transplanted in Switzerland, and 13 of these were foreign. Reasons for refusal were (1) no compatible recipient due to blood group or weight mismatch, 89.4%; (2) medical, meaning organ too marginal for transplantation, 7.4%; (3) logistic, 1.4%; and (4) other, 1.8%. Five organs were refused in Switzerland by one center but later accepted and successfully transplanted by another center. Hearts from outside Switzerland were transplanted significantly less than Swiss hearts (n = 16/120 vs. 10/16, p < .001). CONCLUSION: The most common reason for refusing a pediatric donor heart is lack of compatibility with the recipient. Few hearts are refused for medical reasons. A more generous acceptance seems to be justified in selected patients. Switzerland receives a high number of foreign offers, but their rate of acceptance is lower than that of Swiss donations.


Subject(s)
Heart Transplantation , Tissue Donors , Tissue and Organ Procurement , Humans , Switzerland , Child , Infant , Child, Preschool , Retrospective Studies , Tissue and Organ Procurement/statistics & numerical data , Adolescent , Male , Female , Tissue Donors/supply & distribution , Infant, Newborn
3.
Cell Tissue Bank ; 25(1): 1-10, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37097383

ABSTRACT

Homograft heart valves may have significant advantages and are preferred for the repair of congenital valve malformations, especially in young women of childbearing age, athletes and in patients with active endocarditis. A growing problem, however, is the mismatch between tissue donation and the increasing demand. The aim of this paper is to describe the initiation process of a homograft procurement program to attenuate the shortage of organs. A comprehensive description of the infrastructure and procedural steps required to initiate a cardiac and vascular tissue donation program combined with a prospective follow-up of all homografts explanted at our institution. Between January 2020 and May 2022, 28 hearts and 12 pulmonary bifurcations were harvested at our institution and delivered to the European homograft bank. Twenty-seven valves (19 pulmonary valves, 8 aortic valves) were processed and allocated for implantation. The reasons for discarding a graft were either contamination (n = 14), or morphology (n = 13) or leaflet damage (n = 2). Five homografts (3 PV, 2 AV) have been cryopreserved and stored while awaiting allocation. One pulmonary homograft with a leaflet cut was retrieved by bicuspidization technique and awaits allocation, as a highly requested small diameter graft. The implementation of a tissue donation program in cooperation with a homograft bank can be achieved with reasonable additional efforts at a transplant center with an in-house cardiac surgery department. Challenging situations with a potential risk of tissue injury during procurement include re-operation, harvesting by a non-specialist surgeon and prior central cannulation for mechanical circulatory support.


Subject(s)
Cardiac Surgical Procedures , Tissue Donors , Humans , Female , Prospective Studies , Transplantation, Homologous , Cryopreservation , Allografts
5.
Clin Transplant ; 38(1): e15162, 2024 01.
Article in English | MEDLINE | ID: mdl-37823242

ABSTRACT

BACKGROUND: Pulmonary hypertension (PH) may limit the outcome of pediatric heart transplantation (pHTx). We evaluated pulmonary hemodynamics in children undergoing pHTx. METHODS: Cross-sectional, single-center, observational study analyzing pulmonary hemodynamics in children undergoing pHTx. RESULTS: Twenty-three children (female 15) underwent pHTx at median (IQR) age of 3.9 (.9-8.2) years with a time interval between first clinical signs and pHTx of 1.1 (.4-3.2) years. Indications for pHTx included cardiomyopathy (CMP) (n = 17, 74%), congenital heart disease (CHD) (n = 5, 22%), and intracardiac tumor (n = 1, 4%). Before pHTx, pulmonary hemodynamics included elevated pulmonary artery pressure (PAP) 26 (18.5-30) mmHg, pulmonary capillary wedge pressure (PCWP) 19 (14-21) mmHg, left ventricular enddiastolic pressure (LVEDP) 17 (13-22) mmHg. Transpulmonary pressure gradient (TPG) was 6.5 (3.5-10) mmHg and pulmonary vascular resistance (Rp) 2.65 WU*m2 (1.87-3.19). After pHTx, at immediate evaluation 2 weeks after pHTx PAP decreased to 20.5 (17-24) mmHg, PCWP 14.5 (10.5-18) mmHg (p < .05), LVEDP 16 (12.5-18) mmHg, TPG 6.5 (4-12) mmHg, Rp 1.49 (1.08-2.74) WU*m2 resp.at last invasive follow up 4.0 (1.4-6) years after pHTx, to PAP 19.5 (17-21) mmHg (p < .05), PCWP 13 (10.5-14.5) mmHg (p < .05), LVEDP 13 (10.5-14) mmHg, TPG 7 (5-9.5) mmHg, Rp 1.58 (1.38-2.19) WU*m2 (p < .05). In CHD patients PAP increased (p < .05) after pHTx at immediate evaluation and decreased until last follow-up (p < .05), while in CMP patients there was a continuous decline of mean PAP values immediately after HTx (p < .05). CONCLUSIONS: While PH before pHTx is frequent, after pHTx the normalization of PH starts immediately in CMP patients but is delayed in CHD patients.


Subject(s)
Heart Transplantation , Hypertension, Pulmonary , Humans , Female , Child , Child, Preschool , Cross-Sectional Studies , Hemodynamics , Vascular Resistance , Pulmonary Wedge Pressure , Heart Transplantation/adverse effects
6.
J Cardiovasc Dev Dis ; 10(8)2023 Aug 17.
Article in English | MEDLINE | ID: mdl-37623364

ABSTRACT

Purpose: The withdrawal of HVAD in 2021 created a concern for the pediatric population. The alternative implantable centrifugal blood pump HeartMate 3 has since been used more frequently in children. This paper analyses the outcome of children on LVAD support provided with an HVAD or HM3. Methods: A retrospective analysis of the EUROMACS database on children supported with VAD < 19 years of age from 1 January 2009 to 1 December 2021 was conducted. All patients with an LVAD and either an HVAD or HM3 were included. Patients with missing data on VAD status and/or missing baseline and/or follow up information were excluded. Kaplan-Meier survival analysis was performed to evaluate survival differences. Analyses were performed using Fisher's exact test. Results: The study included 150 implantations in 142 patients with 128 implants using an HVAD compared to 28 implants using an HM3. Nine patients (6%) needed temporary right ventricular mechanical support, which was significantly higher in the HM3 group, with 25% (p: 0.01). Patients in the HVAD group were significantly younger (12.7 vs. 14.5 years, p: 0.01), weighed less (45.7 vs. 60 kg, p: <0.000) and had lower BSA values (1.3 vs. 1.6 m2, p: <0.000). Median support time was 204 days. Overall, 98 patients (69%) were discharged and sent home, while 87% were discharged in group HM3 (p: ns). A total of 123 children (86%) survived to transplantation, recovery or are ongoing, without differences between groups. In the HVAD group, 10 patients (8%) died while on support, whereas in 12% of HM3 patients died (p: 0.7). Conclusions: Survival in children implanted with an HM3 was excellent. Almost 90% were discharged and sent home on the device.

7.
Eur J Cardiothorac Surg ; 64(2)2023 08 01.
Article in English | MEDLINE | ID: mdl-37498565

ABSTRACT

OBJECTIVES: A small percentage of paediatric patients supported with a ventricular assist device (VAD) can have their device explanted following myocardial recovery. The goal of this systematic review is to summarize the current literature on the clinical course in these children after weaning. METHODS: A systematic literature search was performed on 27 May 2022 using Embase, Medline ALL, Web of Science Core Collection, Cochrane Central Register of Controlled Trials and Google Scholar to include all literature on paediatric patients supported by a durable VAD during the last decade. Overlapping study cohorts and registry-based studies were filtered out. RESULTS: Thirty-seven articles were included. Eighteen of them reported on the incidence of recovery in cohort studies, with an overall incidence rate of 8.7% (81/928). Twenty-two of the included articles reported on clinical outcomes after VAD explantation (83 patients). The aetiologies varied widely and were not limited to diseases with a natural transient course like myocarditis. Most of the patients in the included studies (70; 84.3%) were supported by a Berlin Heart EXCOR, and in 66.3% (55/83), only the left ventricle had to be supported. The longest follow-up period was 19.1 years, and multiple studies reported on long-term myocardial recovery. Fewer than half of the reported deaths had a cardiac cause. CONCLUSIONS: Myocardial recovery during VAD support is dependent on various contributing components. The interactions among patient-, device-, time- and hospital-related factors are complex and not yet fully understood. Long-term recovery after VAD support is achievable, even after a long duration of VAD support, and even in patients with aetiologies different from myocarditis or post-cardiotomy heart failure. More research is needed on this favourable outcome after VAD support.


Subject(s)
Heart Failure , Heart-Assist Devices , Myocarditis , Child , Humans , Heart-Assist Devices/adverse effects , Myocarditis/complications , Treatment Outcome , Heart Failure/surgery , Heart Failure/etiology , Heart , Retrospective Studies
8.
Life (Basel) ; 13(7)2023 Jul 19.
Article in English | MEDLINE | ID: mdl-37511957

ABSTRACT

For children born with congenital heart defects (CHDs), extracorporeal life support may be necessary. This retrospective single-center study aimed to investigate the outcomes of children with CHDs on extracorporeal membrane oxygenation (ECMO), focusing on various risk factors. Among the 88 patients, 36 (41%) had a single-ventricle heart defect, while 52 (59%) had a biventricular defect. In total, 25 (28%) survived, with 7 (8%) in the first group and 18 (20%) in the latter. A p-value of 0.19 indicated no significant difference in survival rates. Children with biventricular hearts had shorter ECMO durations but longer stays in the intensive care unit. The overall rate of complications on ECMO was higher in children with a single ventricle (odds ratio [OR] 1.57, 95% confidence interval [CI] 0.67-3.7); bleeding was the most common complication in both groups. The occurrence of a second ECMO run was more frequent in patients with a single ventricle (22% vs. 9.6%). ECMO can be effective for children with congenital heart defects, including single-ventricle patients. Bleeding remains a serious complication associated with worse outcomes. Patients requiring a second ECMO run within 30 days have lower survival rates.

10.
Artif Organs ; 47(8): 1319-1325, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36855905

ABSTRACT

BACKGROUND: Data on the use and outcome of children on ventricular assist device (VAD) support provided with an implantable cardioverter-defibrillator (ICD) remains poor. METHODS: A retrospective analysis of the EUROMACS database on children supported with VAD < 19 years of age from January 1, 2009 to April 1, 2020. Patients with missing data on status of ICD, missing baseline and/or follow up information were excluded. The primary independent variable of interest was the concomitant presence or absence of an ICD at the time of VAD placement. Kaplan-Meier survival analysis was performed to evaluate survival differences between children on VAD with and without an ICD. RESULTS: Out of 303 patients provided with a VAD, 7% (7♀, 15♂) had an ICD implanted and formed the study group. Median age was 14 years, median weight was 43.5 kg, and median BSA was 1.39. Median Intermacs stage was 2 (range: 1-7). Seventeen patients (77%) were transplanted, 4 (18%) died while on support, and 1 (5%) was weaned from device after myocardial recovery. Median time on support was 68 days compared to 361 days in the control group (p: 0.01). Three patients underwent device exchange due to thrombus formation in the pump. There was no difference in survival between groups (p = 0.342). CONCLUSION: The presence of ICD in pediatric patients supported with a VAD is low (7%). Children on VAD support provided with an ICD do not have a survival benefit compared to children without an ICD.


Subject(s)
Defibrillators, Implantable , Heart Failure , Heart-Assist Devices , Humans , Child , Adolescent , Heart Failure/surgery , Retrospective Studies , Registries , Treatment Outcome
11.
Artif Organs ; 47(3): 582-588, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36356800

ABSTRACT

BACKGROUND: Interhospital transfers of pediatric patients on the Berlin Heart Excor have been published on an occasional basis. METHODS: Nowadays medicine evolves away from just feasibility towards quality and safety issues. Management tools like risk analysis have found their way into clinical practice. RESULTS: Exemplary, we present a case of a 20 months old boy on a Berlin Heart BiVAD Excor who underwent a 224 km ground transport. After a systematic review of the published literature, we describe our safety management with the aim was to provide highest quality of care for the transport. CONCLUSION: Besides a risk analysis, we also describe our training and simulation protocol.


Subject(s)
Heart Failure , Heart Transplantation , Heart-Assist Devices , Male , Humans , Child , Infant , Treatment Outcome , Heart , Risk Assessment
13.
Life (Basel) ; 12(9)2022 Sep 08.
Article in English | MEDLINE | ID: mdl-36143434

ABSTRACT

Veno-arterial extracorporeal membrane oxygenation (V-A ECMO) is frequently used in children with and without congenital heart disease (CHD). This study, of a single-center and retrospective design, evaluated the use and timing of V-A ECMO in a pediatric cohort who underwent V-A ECMO implantation between January 2009 and December 2019. The patients were divided into a pre-/non-surgical group and a post-surgical group. Among the investigated variables were age, gender, weight, duration of ECMO, ECMO indication, and ventricular physiology, with only the latter being statistically relevant between the two groups. A total of 111 children (58 male/53 female), with a median age of 87 days (IQR: 7-623) were supported using V-A ECMO. The pre-/non-surgical group consisted of 59 patients and the post-surgical group of 52 patients. Survival at discharge was 49% for the pre-/non-surgical group and 21% for the surgical group (p = 0.04). Single-ventricle physiology was significant for a worse outcome (p = 0.0193). Heart anatomy still has the biggest role in the outcomes of children on ECMO. Nevertheless, children with CHD can be successfully bridged with ECMO to cardiac operation.

14.
Eur J Cardiothorac Surg ; 62(2)2022 07 11.
Article in English | MEDLINE | ID: mdl-35758622

ABSTRACT

OBJECTIVES: A third paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (<19 years of age) performed from 1 January 2000 to 31 December 2020 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-five hospitals contributed 537 registered implants in 480 patients. The most frequent aetiology of heart failure was any form of cardiomyopathy (59%), followed by congenital heart disease and myocarditis (15% and 14%, respectively). Competing outcomes analysis revealed that a total of 86% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 21.9% died while on support. At 12 months, 45.1% received transplants, 7.5% were weaned from their device and 20.8% died. The 3-month adverse events rate was 1.59 per patient-year for device malfunction including pump exchange, 0.7 for major bleeding, 0.78 for major infection and 0.71 for neurological events. CONCLUSIONS: The overall survival rate was 79.2% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age; P = 0.01) and lower weight (<20 kg; P = 0.015). Transplant rates at 6 months continue to be low (33.2%).


Subject(s)
Heart Defects, Congenital , Heart Failure , Heart-Assist Devices , Thoracic Surgical Procedures , Child , Heart Defects, Congenital/epidemiology , Heart Defects, Congenital/surgery , Heart Failure/epidemiology , Heart Failure/etiology , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Humans , Registries , Retrospective Studies , Treatment Outcome
15.
Sci Rep ; 12(1): 5761, 2022 04 06.
Article in English | MEDLINE | ID: mdl-35388023

ABSTRACT

Successful therapy of heart failure with preserved ejection fraction (HFpEF) remains a major unmet clinical need. Device-based treatment approaches include the interatrial shunt device (IASD), conventional assist devices pumping blood from the left ventricle (LV-VAD) or the left atrium (LA-VAD) towards the aorta, and a valveless pulsatile assist device with a single cannula operating in co-pulsation with the native heart (CoPulse). Hemodynamics of two HFpEF subgroups during rest and exercise condition were translated into a lumped parameter model of the cardiovascular system. The numerical model was applied to assess the hemodynamic effect of each of the four device-based therapies. All four therapy options show a reduction in left atrial pressure during rest and exercise and in both subgroups (> 20%). IASDs concomitantly reduce cardiac output (CO) and shift the hemodynamic overload towards the pulmonary circulation. All three mechanical assist devices increase CO while reducing sympathetic activity. LV-VADs reduce end-systolic volume, indicating a high risk for suction events. The heterogeneity of the HFpEF population requires an individualized therapy approach based on the underlying hemodynamics. Whereas phenotypes with preserved CO may benefit most from an IASD device, HFpEF patients with reduced CO may be candidates for mechanical assist devices.


Subject(s)
Heart Failure , Atrial Pressure , Heart Atria , Heart Failure/therapy , Hemodynamics , Humans , Stroke Volume , Ventricular Function, Left
16.
Interact Cardiovasc Thorac Surg ; 34(6): 1171-1173, 2022 06 01.
Article in English | MEDLINE | ID: mdl-34718576

ABSTRACT

We present a case of an anomalous origin of the left coronary artery from the pulmonary artery, with a proximal intramural course in the aortic wall. We describe the technique of its reimplantation at the site of the transverse aortotomy, using autologous pericardial patch enlargement of the newly created coronary ostium.


Subject(s)
Bland White Garland Syndrome , Coronary Vessel Anomalies , Aorta/diagnostic imaging , Aorta/surgery , Coronary Vessel Anomalies/complications , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessel Anomalies/surgery , Humans , Pulmonary Artery/abnormalities , Replantation/methods
20.
Interact Cardiovasc Thorac Surg ; 33(5): 837-839, 2021 10 29.
Article in English | MEDLINE | ID: mdl-34117495

ABSTRACT

Even though preoperative diagnostics have improved significantly, intraoperative surprises may still occur especially in the case of complex congenital heart disease. An instance of such a complex congenital heart disease is a hypoplastic left heart syndrome with a right-sided aortic arch. In this case report, we present 1 patient with such a complex and unexpected anatomy, as well as a possible way to overcome the obstacles.


Subject(s)
Hypoplastic Left Heart Syndrome , Situs Inversus , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Humans , Hypoplastic Left Heart Syndrome/diagnostic imaging , Hypoplastic Left Heart Syndrome/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...