1.
Nanoscale ; 12(41): 21131-21137, 2020 Nov 07.
Article in English | MEDLINE | ID: mdl-33079117

ABSTRACT

The small molecule biotin and the homotetrameric protein streptavidin (SA) form a stable and robust complex that plays a pivotal role in many biotechnological and medical applications. In particular, the SA-biotin linkage is frequently used in single-molecule force spectroscopy (SMFS) experiments. Recent data suggest that SA-biotin bonds show strong directional dependence and a broad range of multi-exponential lifetimes under load. Here, we investigate engineered SA variants with different valencies and a unique tethering point under constant forces using a magnetic tweezers assay. We observed orders-of-magnitude differences in the lifetimes under force, which we attribute to the distinct force-loading geometries in the different SA variants. Lifetimes showed exponential dependencies on force, with extrapolated lifetimes at zero force that are similar for the different SA variants and agree with parameters determined from constant-speed dynamic SMFS experiments. We identified an especially long-lived tethering geometry that will facilitate ultra-stable SMFS experiments.


Subject(s)
Biotin , Single Molecule Imaging , Mechanical Phenomena , Microscopy, Atomic Force , Streptavidin
2.
Nucleic Acids Res ; 48(14): 8090-8098, 2020 08 20.
Article in English | MEDLINE | ID: mdl-32597986

ABSTRACT

The DNA four-way (Holliday) junction is the central intermediate of genetic recombination, yet key aspects of its conformational and thermodynamic properties remain unclear. While multiple experimental approaches have been used to characterize the canonical X-shape conformers under specific ionic conditions, the complete conformational ensemble of this motif, especially at low ionic conditions, remains largely undetermined. In line with previous studies, our single-molecule Förster resonance energy transfer (smFRET) measurements of junction dynamics revealed transitions between two states under high salt conditions, but smFRET could not determine whether there are fast and unresolvable transitions between distinct conformations or a broad ensemble of related states under low and intermediate salt conditions. We therefore used an emerging technique, X-ray scattering interferometry (XSI), to directly probe the conformational ensemble of the Holliday junction across a wide range of ionic conditions. Our results demonstrated that the four-way junction adopts an out-of-plane geometry under low ionic conditions and revealed a conformational state at intermediate ionic conditions previously undetected by other methods. Our results provide critical information to build toward a full description of the conformational landscape of the Holliday junction and underscore the utility of XSI for probing conformational ensembles under a wide range of solution conditions.


Subject(s)
DNA, Cruciform/chemistry , Fluorescence Resonance Energy Transfer , Molecular Dynamics Simulation , Osmolar Concentration , X-Ray Diffraction
3.
Sci Adv ; 6(13): eaay5999, 2020 03.
Article in English | MEDLINE | ID: mdl-32232150

ABSTRACT

Macromolecules tend to respond to applied forces in many different ways. Chemistry at high shear forces can be intriguing, with relatively soft bonds becoming very stiff in specific force-loading geometries. Largely used in bionanotechnology, an important case is the streptavidin (SA)/biotin interaction. Although SA's four subunits have the same affinity, we find that the forces required to break the SA/biotin bond depend strongly on the attachment geometry. With AFM-based single-molecule force spectroscopy (SMFS), we measured unbinding forces of biotin from different SA subunits to range from 100 to more than 400 pN. Using a wide-sampling approach, we carried out hundreds of all-atom steered molecular dynamics (SMD) simulations for the entire system, including molecular linkers. Our strategy revealed the molecular mechanism that causes a fourfold difference in mechanical stability: Certain force-loading geometries induce conformational changes in SA's binding pocket lowering the energy barrier, which biotin has to overcome to escape the pocket.


Subject(s)
Biotin/chemistry , Chemical Phenomena , Macromolecular Substances/chemistry , Models, Molecular , Streptavidin/chemistry , Microscopy, Atomic Force , Molecular Conformation , Protein Binding , Structure-Activity Relationship
4.
Small ; 16(13): e1906740, 2020 04.
Article in English | MEDLINE | ID: mdl-32141169

ABSTRACT

The mechanobiology of receptor-ligand interactions and force-induced enzymatic turnover can be revealed by simultaneous measurements of force response and fluorescence. Investigations at physiologically relevant high labeled substrate concentrations require total internal reflection fluorescence microscopy or zero mode waveguides (ZMWs), which are difficult to combine with atomic force microscopy (AFM). A fully automatized workflow is established to manipulate single molecules inside ZMWs autonomously with noninvasive cantilever tip localization. A protein model system comprising a receptor-ligand pair of streptavidin blocked with a biotin-tagged ligand is introduced. The ligand is pulled out of streptavidin by an AFM cantilever leaving the receptor vacant for reoccupation by freely diffusing fluorescently labeled biotin, which can be detected in single-molecule fluorescence concurrently to study rebinding rates. This work illustrates the potential of the seamless fusion of these two powerful single-molecule techniques.


Subject(s)
Biophysics , Nanotechnology , Biophysics/methods , Biotin/chemistry , Microscopy, Atomic Force , Microscopy, Fluorescence , Nanotechnology/methods , Streptavidin/chemistry
5.
Nanoscale ; 12(12): 6803-6809, 2020 Mar 28.
Article in English | MEDLINE | ID: mdl-32181776

ABSTRACT

The complex of the small molecule biotin and the homotetrameric protein streptavidin is key to a broad range of biotechnological applications. Therefore, the behavior of this extraordinarily high-affinity interaction under mechanical force is intensively studied by single-molecule force spectroscopy. Recently, steered molecular dynamics simulations have identified a low force pathway for the dissociation of biotin from streptavidin, which involves partial unfolding of the N-terminal ß-sheet structure of monovalent streptavidin's functional subunit. Based on these results, we now introduced two mutations (T18C,A33C) in the functional subunit of monovalent streptavidin to establish a switchable connection (disulfide bridge) between the first two ß-strands to prevent this unfolding. In atomic force microscopy-based single-molecule force spectroscopy experiments, we observed unbinding forces of about 350 pN (at a force-loading rate of 10 nN s-1) for pulling a single biotin out of an N-terminally anchored monovalent streptavidin binding pocket - about 1.5-fold higher compared with what has been reported for N-terminal force loading of native monovalent streptavidin. Upon addition of a reducing agent, the unbinding forces dropped back to 200 pN, as the disulfide bridge was destroyed. Switching from reducing to oxidizing buffer conditions, the inverse effect was observed. Our work illustrates how the mechanics of a receptor-ligand system can be tuned by engineering the receptor protein far off the ligand-binding pocket.


Subject(s)
Biotin/chemistry , Streptavidin/chemistry , Connectin/chemistry , Dictyostelium , Disulfides , Fibrinogen/chemistry , Humans , Ligands , Microscopy, Atomic Force , Models, Chemical , Molecular Dynamics Simulation , Mutagenesis, Site-Directed , Mutation , Oxygen/chemistry , Probability , Protein Binding , Protein Denaturation , Protein Domains , Protein Engineering/methods , Protein Structure, Secondary , Surface Properties
6.
Biophys J ; 118(6): 1344-1356, 2020 03 24.
Article in English | MEDLINE | ID: mdl-32109366

ABSTRACT

Vinculin is a universal adaptor protein that transiently reinforces the mechanical stability of adhesion complexes. It stabilizes mechanical connections that cells establish between the actomyosin cytoskeleton and the extracellular matrix via integrins or to neighboring cells via cadherins, yet little is known regarding its mechanical design. Vinculin binding sites (VBSs) from different nonhomologous actin-binding proteins use conserved helical motifs to associate with the vinculin head domain. We studied the mechanical stability of such complexes by pulling VBS peptides derived from talin, α-actinin, and Shigella IpaA out of the vinculin head domain. Experimental data from atomic force microscopy single-molecule force spectroscopy and steered molecular dynamics (SMD) simulations both revealed greater mechanical stability of the complex for shear-like than for zipper-like pulling configurations. This suggests that reinforcement occurs along preferential force directions, thus stabilizing those cytoskeletal filament architectures that result in shear-like pulling geometries. Large force-induced conformational changes in the vinculin head domain, as well as protein-specific fine-tuning of the VBS sequence, including sequence inversion, allow for an even more nuanced force response.


Subject(s)
Talin , Binding Sites , Models, Molecular , Protein Binding , Talin/metabolism , Vinculin/metabolism
7.
Proc Natl Acad Sci U S A ; 116(38): 18798-18807, 2019 09 17.
Article in English | MEDLINE | ID: mdl-31462494

ABSTRACT

Single-molecule force spectroscopy has provided unprecedented insights into protein folding, force regulation, and function. So far, the field has relied primarily on atomic force microscope and optical tweezers assays that, while powerful, are limited in force resolution, throughput, and require feedback for constant force measurements. Here, we present a modular approach based on magnetic tweezers (MT) for highly multiplexed protein force spectroscopy. Our approach uses elastin-like polypeptide linkers for the specific attachment of proteins, requiring only short peptide tags on the protein of interest. The assay extends protein force spectroscopy into the low force (<1 pN) regime and enables parallel and ultra-stable measurements at constant forces. We present unfolding and refolding data for the small, single-domain protein ddFLN4, commonly used as a molecular fingerprint in force spectroscopy, and for the large, multidomain dimeric protein von Willebrand factor (VWF) that is critically involved in primary hemostasis. For both proteins, our measurements reveal exponential force dependencies of unfolding and refolding rates. We directly resolve the stabilization of the VWF A2 domain by Ca2+ and discover transitions in the VWF C domain stem at low forces that likely constitute the first steps of VWF's mechano-activation. Probing the force-dependent lifetime of biotin-streptavidin bonds, we find that monovalent streptavidin constructs with specific attachment geometry are significantly more force stable than commercial, multivalent streptavidin. We expect our modular approach to enable multiplexed force-spectroscopy measurements for a wide range of proteins, in particular in the physiologically relevant low-force regime.


Subject(s)
Protein Folding , von Willebrand Factor/chemistry , Amino Acids , Calcium/metabolism , Cross-Linking Reagents/chemistry , Elastin/chemistry , Magnetics , Mechanical Phenomena , Protein Binding , Protein Domains , Protein Multimerization , Single Molecule Imaging
8.
Nanoscale ; 11(2): 407-411, 2019 Jan 03.
Article in English | MEDLINE | ID: mdl-30604815

ABSTRACT

Single-molecule cut-and-paste facilitates bottom-up directed assembly of nanoscale biomolecular networks in defined geometries and enables analysis with spatio-temporal resolution. However, arrangement of diverse molecules of interest requires versatile handling systems. The novel DNA-free, genetically encodable scheme described here utilises an orthogonal handling strategy to promote arrangement of enzymes and enzyme networks.


Subject(s)
Enzymes, Immobilized/chemistry , Nanostructures/chemistry , Nanotechnology/methods , Enzymes, Immobilized/metabolism , Fluorescent Dyes , Immobilized Proteins/chemistry , Immobilized Proteins/metabolism , Microscopy, Atomic Force , Microscopy, Fluorescence , Models, Molecular , Nanostructures/ultrastructure
9.
Nano Lett ; 19(6): 3415-3421, 2019 06 12.
Article in English | MEDLINE | ID: mdl-30346175

ABSTRACT

Novel site-specific attachment strategies combined with improvements of computational resources enable new insights into the mechanics of the monovalent biotin/streptavidin complex under load and forced us to rethink the diversity of rupture forces reported in the literature. We discovered that the mechanical stability of this complex depends strongly on the geometry in which force is applied. By atomic force microscopy-based single molecule force spectroscopy we found unbinding of biotin to occur beyond 400 pN at force loading rates of 10 nN/s when monovalent streptavidin was tethered at its C-terminus. This value is about twice as high than that for N-terminal attachment. Steered molecular dynamics simulations provided a detailed picture of the mechanics of the unbinding process in the corresponding force loading geometries. Using machine learning techniques, we connected findings from hundreds of simulations to the experimental results, identifying different force propagation pathways. Interestingly, we observed that depending on force loading geometry, partial unfolding of N-terminal region of monovalent streptavidin occurs before biotin is released from the binding pocket.

10.
PLoS One ; 12(12): e0188722, 2017.
Article in English | MEDLINE | ID: mdl-29206886

ABSTRACT

The widely used interaction of the homotetramer streptavidin with the small molecule biotin has been intensively studied by force spectroscopy and has become a model system for receptor ligand interaction. However, streptavidin's tetravalency results in diverse force propagation pathways through the different binding interfaces. This multiplicity gives rise to polydisperse force spectroscopy data. Here, we present an engineered monovalent streptavidin tetramer with a single cysteine in its functional subunit that allows for site-specific immobilization of the molecule, orthogonal to biotin binding. Functionality of streptavidin and its binding properties for biotin remain unaffected. We thus created a stable and reliable molecular anchor with a unique high-affinity binding site for biotinylated molecules or nanoparticles, which we expect to be useful for many single-molecule applications. To characterize the mechanical properties of the bond between biotin and our monovalent streptavidin, we performed force spectroscopy experiments using an atomic force microscope. We were able to conduct measurements at the single-molecule level with 1:1-stoichiometry and a well-defined geometry, in which force exclusively propagates through a single subunit of the streptavidin tetramer. For different force loading rates, we obtained narrow force distributions of the bond rupture forces ranging from 200 pN at 1,500 pN/s to 230 pN at 110,000 pN/s. The data are in very good agreement with the standard Bell-Evans model with a single potential barrier at Δx0 = 0.38 nm and a zero-force off-rate koff,0 in the 10-6 s-1 range.


Subject(s)
Biotin/chemistry , Streptavidin/chemistry , Calorimetry , Cysteine/chemistry , Electrophoresis, Polyacrylamide Gel , Microscopy, Atomic Force
11.
J Appl Crystallogr ; 50(Pt 2): 621-630, 2017 Apr 01.
Article in English | MEDLINE | ID: mdl-28381982

ABSTRACT

A new model is proposed for the measurement errors incurred in typical small-angle X-ray scattering (SAXS) experiments, which takes into account the setup geometry and physics of the measurement process. The model accurately captures the experimentally determined errors from a large range of synchrotron and in-house anode-based measurements. Its most general formulation gives for the variance of the buffer-subtracted SAXS intensity σ2(q) = [I(q) + const.]/(kq), where I(q) is the scattering intensity as a function of the momentum transfer q; k and const. are fitting parameters that are characteristic of the experimental setup. The model gives a concrete procedure for calculating realistic measurement errors for simulated SAXS profiles. In addition, the results provide guidelines for optimizing SAXS measurements, which are in line with established procedures for SAXS experiments, and enable a quantitative evaluation of measurement errors.

12.
Nano Lett ; 16(8): 4871-9, 2016 08 10.
Article in English | MEDLINE | ID: mdl-27356232

ABSTRACT

Self-assembled DNA origami nanostructures enable the creation of precisely defined shapes at the molecular scale. Dynamic DNA devices that are capable of switching between defined conformations could afford completely novel functionalities for diagnostic, therapeutic, or engineering applications. Developing such objects benefits strongly from experimental feedback about conformational changes and 3D structures, ideally in solution, free of potential biases from surface attachment or labeling. Here, we demonstrate that small-angle X-ray scattering (SAXS) can quantitatively resolve the conformational changes of a DNA origami two-state switch device as a function of the ionic strength of the solution. In addition, we show how SAXS data allow for refinement of the predicted idealized three-dimensional structure of the DNA object using a normal mode approach based on an elastic network model. The results reveal deviations from the idealized design geometries that are otherwise difficult to resolve. Our results establish SAXS as a powerful tool to investigate conformational changes and solution structures of DNA origami and we anticipate our methodology to be broadly applicable to increasingly complex DNA and RNA devices.


Subject(s)
DNA/chemistry , Nucleic Acid Conformation , X-Ray Diffraction , Models, Molecular , Scattering, Small Angle
13.
Rev Sci Instrum ; 87(2): 025103, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26931887

ABSTRACT

We demonstrate the use of a molybdenum-anode-based in-house small-angle X-ray scattering (SAXS) setup to study biological macromolecules in solution. Our system consists of a microfocus X-ray tube delivering a highly collimated flux of 2.5 × 10(6) photons/s at a beam size of 1.2 × 1.2 mm(2) at the collimation path exit and a maximum beam divergence of 0.16 mrad. The resulting observable scattering vectors q are in the range of 0.38 Å(-1) down to 0.009 Å(-1) in SAXS configuration and of 0.26 Å(-1) up to 5.7 Å(-1) in wide-angle X-ray scattering (WAXS) mode. To determine the capabilities of the instrument, we collected SAXS data on weakly scattering biological macromolecules including proteins and a nucleic acid sample with molecular weights varying from ∼12 to 69 kDa and concentrations of 1.5-24 mg/ml. The measured scattering data display a high signal-to-noise ratio up to q-values of ∼0.2 Å(-1) allowing for an accurate structural characterization of the samples. Moreover, the in-house source data are of sufficient quality to perform ab initio 3D structure reconstructions that are in excellent agreement with the available crystallographic structures. In addition, measurements for the detergent decyl-maltoside show that the setup can be used to determine the size, shape, and interactions (as characterized by the second virial coefficient) of detergent micelles. This demonstrates that the use of a Mo-anode based in-house source is sufficient to determine basic geometric parameters and 3D shapes of biomolecules and presents a viable alternative to valuable beam time at third generation synchrotron sources.


Subject(s)
Models, Theoretical , Molybdenum , X-Ray Diffraction/instrumentation , X-Ray Diffraction/methods
SELECTION OF CITATIONS