Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 193
Filter
1.
Article in English | MEDLINE | ID: mdl-38719632

ABSTRACT

BACKGROUND: The ACURATE neo2 transcatheter aortic valve was developed to improve paravalvular leak (PVL) rates while maintaining low rates of conduction disturbances and permanent pacemaker implantation (PPMI) seen with its predecessor. We aimed to compare conduction disturbances rates of transcatheter aortic valve replacement (TAVR) using ACURATE Neo2 with other commonly used valves. METHODS: A retrospective analysis of the Israeli TAVR registry between the years 2014-2023 was performed to compare conduction disturbances and PVL rates, and procedural outcomes, among patients treated with ACURATE neo2, Edwards Sapien 3 (S3), and Evolut PRO valves. Propensity score matching was performed to compare groups with similar characteristics. RESULTS: Following exclusion of patients with non-femoral access, unknown valve type, older-generation valves, and less commonly used valves or (n = 4387), our analysis included 3208 patients undergoing TAVR using ACURATE neo2, Edwards S3, and Evolut PRO valves. Propensity matched groups comprised 169 patients each. Rates of any conduction disturbances [left bundle branch block (LBBB), atrioventricular block, or PPMI] were lower in the ACURATE neo2 group compared to both other valves [15.8 %, S3-37.5 % (p < 0.001), Evolut PRO-27.5 % (p = 0.02)] as were LBBB rates [9.0 %, S3-31.3 % (p < 0.001); Evolut PRO-20.1 % (p = 0.01). Atrioventricular block and PPMI rates were lower without statistical significance, as were rates of above-moderate PVL. CONCLUSIONS: In this analysis, TAVR using ACURATE neo2 was associated with a lower composite rate of conduction disturbances in comparison to the Evolut PRO and Edwards S3 valves, mainly due to lower left bundle branch block rates, with non-significantly lower rates of PPMI and PVL.

2.
PLoS One ; 19(4): e0302624, 2024.
Article in English | MEDLINE | ID: mdl-38683804

ABSTRACT

PURPOSE: To evaluate the association of cardiorespiratory fitness with elevated intraocular pressure (IOP) in healthy adults. METHODS: In this cross-sectional study, we evaluated 17,990 asymptomatic self-referred adults free of diabetes or cardiovascular disease who were screened in a preventive healthcare setting. All subjects underwent measurement of IOP and completed a maximal exercise stress test according to the Bruce protocol. Fitness was categorized into age and sex-specific quintiles according to the treadmill time and dichotomized to low (lowest quintile) and non-low fitness groups. Elevated IOP was defined as ≥ 21 mmHg. RESULTS: Median age was 45 (IQR 39-52) years and 12,073 (67%) were men. There were 3,351 (19%) subjects in the low fitness group. Median IOP was 14 mmHg (IQR 12-16) with elevated IOP documented in 188 (1%) subjects. Univariate binary logistic regression model demonstrated that compared with non-low fitness group, subjects in the low fitness group were 2.2 times more likely to have elevated IOP (95% CI 1.598-2.95, p<0.001). Multivariate binary logistic regression with adjustment to known cardiovascular risk factors (age, sex, hypertension, smoking, overweight, regular physical activity, low HDL cholesterol, high triglycerides, and fasting glucose levels) successfully demonstrated that lower fitness was independently and significantly associated with a 90% increased likelihood of elevated IOP (95% CI 1.37-2.61, p<0.001). Subgroup analysis revealed that the association was more pronounced among women compared with men (OR 3.8 vs. 1.6, p for interaction = 0.069). CONCLUSIONS: Low cardiorespiratory fitness is independently associated with increased IOP among apparently healthy adults.


Subject(s)
Cardiorespiratory Fitness , Intraocular Pressure , Humans , Male , Female , Cardiorespiratory Fitness/physiology , Adult , Middle Aged , Intraocular Pressure/physiology , Cross-Sectional Studies , Exercise Test , Risk Factors
4.
Article in English | MEDLINE | ID: mdl-38522765

ABSTRACT

Continued circulation of severe acute respiratory syndrome coronavirus 2 has driven the selection of variants with improved ability to escape preexisting vaccine-induced responses, posing a persistent threat to heart transplant recipients (HTRs). The immunogenicity and safety of the updated XBB.1.5-containing monovalent vaccines are unknown. We prospectively enrolled 52 HTRs who had previously received a 5-dose ancestral-derived monovalent and bivalent messenger RNA (mRNA) vaccination schedule to receive the monovalent XBB.1.5 vaccine. Immunogenicity was evaluated using live virus microneutralization assays. The XBB.1.5 monovalent vaccine elicited potent and diverse neutralizing responses and broadened the reactivity spectrum to encompass newer strains, with the highest increase in neutralization activity being more pronounced against XBB.1.5 (15.8-fold) and JN.1 (13.3-fold) than against BA.5 (6.7-fold) and wild-type (4-fold). Notably, XBB.1.5 and JN.1 were resistant to neutralization by prevaccination sera. There were no safety concerns. Our findings support the updating of coronavirus disease 2019 vaccines to match antigenically divergent variants and exclude ancestral spike-antigen to protect HTRs.

5.
Circ Arrhythm Electrophysiol ; 17(3): e012278, 2024 03.
Article in English | MEDLINE | ID: mdl-38344845

ABSTRACT

BACKGROUND: Electroporation is a promising nonthermal ablation method for cardiac arrhythmia treatment. Although initial clinical studies found electroporation pulsed-field ablation (PFA) both safe and efficacious, there are significant knowledge gaps concerning the mechanistic nature and electrophysiological consequences of cardiomyocyte electroporation, contributed by the paucity of suitable human in vitro models. Here, we aimed to establish and characterize a functional in vitro model based on human-induced pluripotent stem cells (hiPSCs)-derived cardiac tissue, and to study the fundamentals of cardiac PFA. METHODS: hiPSC-derived cardiomyocytes were seeded as circular cell sheets and subjected to different PFA protocols. Detailed optical mapping, cellular, and molecular characterizations were performed to study PFA mechanisms and electrophysiological outcomes. RESULTS: PFA generated electrically silenced lesions within the hiPSC-derived cardiac circular cell sheets, resulting in areas of conduction block. Both reversible and irreversible electroporation components were identified. Significant electroporation reversibility was documented within 5 to 15-minutes post-PFA. Irreversibly electroporated regions persisted at 24-hours post-PFA. Per single pulse, high-frequency PFA was less efficacious than standard (monophasic) PFA, whereas increasing pulse-number augmented lesion size and diminished reversible electroporation. PFA augmentation could also be achieved by increasing extracellular Ca2+ levels. Flow-cytometry experiments revealed that regulated cell death played an important role following PFA. Assessing for PFA antiarrhythmic properties, sustainable lines of conduction block could be generated using PFA, which could either terminate or isolate arrhythmic activity in the hiPSC-derived cardiac circular cell sheets. CONCLUSIONS: Cardiac electroporation may be studied using hiPSC-derived cardiac tissue, providing novel insights into PFA temporal and electrophysiological characteristics, facilitating electroporation protocol optimization, screening for potential PFA-sensitizers, and investigating the mechanistic nature of PFA antiarrhythmic properties.


Subject(s)
Catheter Ablation , Induced Pluripotent Stem Cells , Humans , Induced Pluripotent Stem Cells/metabolism , Arrhythmias, Cardiac/genetics , Arrhythmias, Cardiac/surgery , Anti-Arrhythmia Agents/therapeutic use , Myocytes, Cardiac/metabolism , Electroporation , Catheter Ablation/methods
6.
Hellenic J Cardiol ; 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38280633

ABSTRACT

BACKGROUND: The ratio between early mitral flow wave to early diastolic mitral annulus velocity (E/e' ratio) varies according to age and sex and is associated with mortality in heart failure. We sought to describe the association between E/e' and mortality in patients with no apparent structural or functional cardiac abnormality and explore possible modifiers of this association. METHODS: A retrospective study of 104,315 patients who underwent echocardiographic evaluation during 2009-2021 in the largest tertiary center in Israel. Patients with cancer, ventricular dysfunction, significant valvular or structural heart disease, or evidence of pulmonary hypertension were excluded. RESULTS: The final analysis included 32,836 patients with a median age of 56 (43-66) years, and 13,547 (41%) were female. The median E/e' was 8.3 (6.8-10.3), and 9,306 (28%) had an E/e' >10. During a median follow-up of 5.7 (3.3-8.5) years, 2,396 (7.3%) individuals died. E/e' >10 was associated with mortality (adjusted hazard ratio [HR] 1.16, 95% confidence interval [CI] 1.07-1.27, p<0.001). The mortality risk associated with E/e' >10 was significantly higher in those aged ≤70 (HR 1.26, 95% CI 1.12-1.42, p<0.001), males (HR 1.34, 95% CI 1.19-1.49, p<0.001), a normal left ventricular mass (HR 1.13, 95% CI 1.02-1.24, p = 0.017), and pulmonary artery pressure <30 mmHg (HR 1.18, 95% CI 1.06-1.30, p = 0.003). CONCLUSION: An elevated E/e' is associated with mortality, specifically in younger individuals, males, and those with a normal left ventricular mass and lower pulmonary artery pressure. This suggests that an elevated E/e' might be a marker of subclinical risk in these subgroups. Further studies are needed to identify whether an elevated E/e' is useful in shared decision-making regarding the management of cardiovascular risk factors.

7.
J Am Heart Assoc ; 13(2): e029051, 2024 Jan 16.
Article in English | MEDLINE | ID: mdl-38214256

ABSTRACT

BACKGROUND: Patients treated with percutaneous coronary intervention are often considered to be at a high bleeding risk (HBR). Drug-eluting stents have been shown to be superior to bare-metal stents in patients with HBR, even when patients were given abbreviated periods of dual antiplatelet therapy (DAPT). Short DAPT has not been evaluated with the EluNIR ridaforolimus-eluting stent. The aim of this study was to evaluate the safety and efficacy of a shortened period of DAPT following implantation of the ridaforolimus-eluting stent in patients with HBR. METHODS AND RESULTS: This was a prospective, multicenter, binational, single-arm, open-label trial. Patients were defined as HBR according to the LEADERS-FREE (Prospective Randomized Comparison of the BioFreedom Biolimus A9 Drug-Coated Stent versus the Gazelle Bare-Metal Stent in Patients at High Bleeding Risk) trial criteria. After percutaneous coronary intervention, DAPT was given for 1 month to patients presenting with stable angina. In patients presenting with an acute coronary syndrome, DAPT was given for 1 to 3 months, at the investigator's discretion. The primary end point was a composite of cardiac death, myocardial infarction, or stent thrombosis up to 1 year (Academic Research Consortium definite and probable). Three hundred fifteen patients undergoing percutaneous coronary intervention were enrolled, and 56.4% presented with acute coronary syndrome; 33.7% were receiving oral anticoagulation. At 1 year, the primary end point occurred in 15 patients (4.9%), meeting the prespecified performance goal of 14.1% (P<0.0001). Stent thrombosis (Academic Research Consortium definite and probable) occurred in 2 patients (0.6%). Bleeding Academic Research Consortium type 3 and 5 bleeding occurred in 6 patients (1.9%). CONCLUSIONS: We observed favorable results in patients with HBR who underwent percutaneous coronary intervention with a ridaforolimus-eluting stent and received shortened DAPT, including a low rate of ischemic events and low rate of stent thrombosis. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03877848.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Sirolimus/analogs & derivatives , Thrombosis , Humans , Platelet Aggregation Inhibitors/therapeutic use , Acute Coronary Syndrome/drug therapy , Prospective Studies , Treatment Outcome , Hemorrhage/chemically induced , Stents , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Thrombosis/etiology , Drug Therapy, Combination , Coronary Artery Disease/drug therapy
8.
J Invasive Cardiol ; 36(1)2024 Jan.
Article in English | MEDLINE | ID: mdl-38224295

ABSTRACT

OBJECTIVES: Ostial CTOs can be challenging to revascularize. We aim to describe the outcomes of ostial chronic total occlusion (CTO) percutaneous coronary intervention (PCI). METHODS: We examined the clinical and angiographic characteristics and procedural outcomes of 8788 CTO PCIs performed at 35 US and non-US centers between 2012 and 2022. In-hospital major adverse cardiac events (MACE) included death, myocardial infarction, urgent repeat target-vessel revascularization, tamponade requiring pericardiocentesis or surgery, and stroke. RESULTS: Ostial CTOs constituted 12% of all CTOs. Patients with ostial CTOs had higher J-CTO score (2.9 ± 1.2 vs 2.3 ± 1.3; P less than .01). Ostial CTO PCI had lower technical (82% vs. 86%; P less than .01) and procedural (81% vs. 85%; P less than .01) success rates compared with non-ostial CTO PCI. Ostial location was not independently associated with technical success (OR 1.03, CI 95% 0.83-1.29 P =.73). Ostial CTO PCI had a trend towards higher incidence of MACE (2.6% vs. 1.8%; P =.06), driven by higher incidence of in-hospital death (0.9% vs 0.3% P less than.01) and stroke (0.5% vs 0.1% P less than .01). Ostial lesions required more often use of the retrograde approach (30% vs 9%; P less than .01). Ostial CTO PCI required longer procedure time (149 [103,204] vs 110 [72,160] min; P less than .01) and higher air kerma radiation dose (2.3 [1.3, 3.6] vs 2.0 [1.1, 3.5] Gray; P less than .01). CONCLUSIONS: Ostial CTOs are associated with higher lesion complexity and lower technical and procedural success rates. CTO PCI of ostial lesions is associated with frequent need for retrograde crossing, higher incidence of death and stroke, longer procedure time and higher radiation dose.


Subject(s)
Percutaneous Coronary Intervention , Stroke , Humans , Hospital Mortality , Percutaneous Coronary Intervention/adverse effects , Echocardiography , Stroke/diagnosis , Stroke/epidemiology , Stroke/etiology , Hemodynamics
9.
Clin Res Cardiol ; 113(1): 11-17, 2024 Jan.
Article in English | MEDLINE | ID: mdl-36995477

ABSTRACT

BACKGROUND: Chronic coronary syndrome (CCS) is common among elderly patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). Current guidelines recommend performance of percutaneous coronary intervention (PCI) of any > 70% proximal coronary lesions prior to TAVI. AIMS: To evaluate the outcomes of two diagnostic approaches for CCS clearance pre-TAVI and to determine the reduction in the need of invasive angiography (IA). METHODS: We investigated 2219 patients undergoing TAVI for severe aortic stenosis at two large centers with different pre-procedural strategies for CCS assessment: pre-TAVI computed tomography angiography (CTA) with selective invasive angiography according to CTA results or mandatory IA. We preformed propensity score matching analysis using a 1:1 ratio. The final study cohort included 870 matched patients. Peri-procedural complications were documented according to the VARC-2 criteria. Mortality rates were prospectively documented. RESULTS: Mean age of the study population was 82 ± 7, of whom 55% were female. Patients in the IA group had significantly higher rates of pre-TAVI PCI compared to the CTA group (39% vs. 22%, p < 0.001). Following TAVI, peri-procedural myocardial infarction (MI) rates were similar between the two groups (0.3% vs. 0.7%, p value = 0.41), but spontaneous MI were significantly lower among the IA group (0% vs. 1.3%, p value = 0.03). Kaplan-Meier's survival analysis found that the cumulative probability of 1-year morality was similar between the two groups (p value log rank = 0.65). Cox regression analysis did not find association between CCS clearance strategy and outcome. CONCLUSIONS: In elderly patients, CTA-driven approach for CCS evaluation pre-TAVI is a valid strategy with similar outcome as compared to invasive approach. CTA strategy significantly reduces invasive procedures rates without compromising patient's outcome.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Heart Valve Prosthesis Implantation , Myocardial Infarction , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Male , Transcatheter Aortic Valve Replacement/methods , Percutaneous Coronary Intervention/adverse effects , Aortic Valve Stenosis/surgery , Propensity Score , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Coronary Artery Disease/surgery , Myocardial Infarction/complications , Aortic Valve/surgery , Retrospective Studies
10.
Catheter Cardiovasc Interv ; 103(1): 160-168, 2024 01.
Article in English | MEDLINE | ID: mdl-38059295

ABSTRACT

BACKGROUND: New vascular closure devices (VCD) are being introduced for achieving hemostasis after transcatheter aortic valve implantation (TAVI). However, no safety or efficacy data have been published compared to other contemporary VCD. AIM: To compare the safety and efficacy of suture-based Perclose Prostyle as compared to plug-based MANTA device. METHODS: A total of 408 consecutive TAVI patients from two high volume TAVI centers were included in the present study. Patients were grouped according to VCD: Prostyle versus MANTA. Propensity score matching (PSM) and multivariable analysis were utilized to compare clinical endpoints between the two groups. The primary endpoint was any vascular complication (VC) according to VARC-3 criteria. RESULTS: After PSM, a total of 264 patients were analyzed, of them 132 in each group. Overall baseline characteristics of the two groups were comparable. Primary end-point was similar between MANTA as compared to Prostyle (16.7% vs. 15.3% respectively, p = 0.888). The main driver for VC among MANTA group were minor vascular complications (15.2%). Conversely, minor and major VC contributed equally to the primary endpoint among Prostyle group (7.6%) (p = 0.013). No outcome predictors were identified in multivariate analysis. CONCLUSIONS: VCD for transfemoral TAVI using the new-generation Prostyle device or the MANTA device achieved comparable VARC-3 VC rates.


Subject(s)
Aortic Valve Stenosis , Catheterization, Peripheral , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Catheterization, Peripheral/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Hemostatic Techniques/adverse effects
11.
Eur J Cancer Prev ; 33(1): 11-18, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37401480

ABSTRACT

BACKGROUND: The association between mildly decreased renal function and cardiovascular (CV) outcomes in cancer patients remains unestablished. AIMS: We sought to explore this association in asymptomatic self-referred healthy adults. METHOD: We followed 25, 274 adults, aged 40-79 years, who were screened in preventive healthcare settings. Participants were free of CV disease or cancer at baseline. The estimated glomerular filtration rate (eGFR) was calculated according to the CKD Epidemiology Collaboration equation and categorized into groups [≤59, 60-69, 70-79, 80-89, 90-99, ≥100 (ml/min/1.73 m²)]. The outcome included a composite of death, acute coronary syndrome, or stroke, examined using a Cox model with cancer as a time-dependent variable. RESULTS: Mean age at baseline was 50 ±â€…8 years and 7973 (32%) were women. During a median follow-up of 6 years (interquartile range: 3-11), 1879 (7.4%) participants were diagnosed with cancer, of them 504 (27%) develop the composite outcome and 82 (4%) presented with CV events. Multivariable time-dependent analysis showed an increased risk of 1.6, 1.4, and 1.8 for the composite outcome among individuals with eGFR of 90-99 [95% confidence interval (CI): 1.2-2.1 P = 0.01], 80-89 (95% CI: 1.1-1.9, P = 0.01) and 70-79 (95% CI: 1.4-2.3, P < 0.001), respectively. The association between eGFR and the composite outcome was modified by cancer with 2.7-2.9 greater risk among cancer patients with eGFR of 90-99 and 80-89 but not among individuals free from cancer ( Pinteraction < 0.001). CONCLUSION: Patients with mild renal impairment are at high risk for CV events and all-cause mortality following cancer diagnosis. eGFR evaluation should be considered in the CV risk assessment of cancer patients.


Subject(s)
Cardiovascular Diseases , Neoplasms , Stroke , Adult , Humans , Female , Male , Stroke/epidemiology , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/prevention & control , Risk Assessment , Proportional Hazards Models , Risk Factors , Neoplasms/diagnosis , Neoplasms/epidemiology
12.
Catheter Cardiovasc Interv ; 103(1): 61-67, 2024 01.
Article in English | MEDLINE | ID: mdl-38098249

ABSTRACT

INTRODUCTION: The ridaforolimus-eluting stent (RES) system uses a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting ridaforolimus. AIM OF STUDY: To assess the safety and efficacy of small diameter (2.25 mm) RES (EluNIR) in small coronary artery disease. METHODS: A prospective, multicenter, single-arm, open-label clinical trial. Clinical follow-up was performed at 30 days, 6 months, and 1 year after the procedure. Target lesions were located in native coronary arteries or bypass graft conduits, with visually estimated diameter of ≥2.25 mm to ≤2.5 mm. The primary endpoint was combined device success, defined as final in-stent residual diameter stenosis <30%, without 30-day major adverse cardiovascular events (MACE). RESULTS: A total of 81 patients were enrolled in the study. Twenty-three patients (28%) had acute coronary syndrome (ACS) at presentation and 37 (46%) had prior myocardial infarction (MI). Most of the target lesions were located in the circumflex coronary artery (44%) and were classified as B2/C grade according to the American Heart Association/American College of Cardiology classification. The final mean minimal lumen diameter, mean reference vessel diameter, and mean residual percent diameter stenosis were 2.0 ± 0.2 mm, 2.3 ± 0.1 mm, and 14 + 6.6%, respectively. The primary endpoint of device success without 30-day MACE was achieved in 98.8% of the patients. Target lesion failure (TLF) at 6 months was 1.2%. Thirty-day and 1-year MACE rates were 1.2% and 2.5%, respectively. CONCLUSION: The EluNIR 2.25 mm stent shows excellent results in small coronary artery disease and adds another tool in the treatment of this complex lesion type.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Constriction, Pathologic , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/etiology , Prospective Studies , Prosthesis Design , Treatment Outcome
15.
Cancer Epidemiol ; 86: 102428, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37482051

ABSTRACT

BACKGROUND: The association between mildly impaired renal function with all-site and site-specific cancer risk is not established. We aim to explore this association among apparently healthy adults. METHODS: We followed 25,073 men and women, aged 40-79 years, free of cancer or cardiovascular disease at baseline who were screened annually in preventive healthcare settings. The estimated glomerular filtration rate (eGFR) was calculated using the CKD Epidemiology Collaboration equation (CKD-EPI) and classified into four mutually exclusive groups: <60, 60-74, 75-89, ≥90 (mL/min/1.73 m²). The primary outcome was all-site cancer while the secondary outcome was site-specific cancer. Cancer data was available from a national registry. RESULTS: Mean age at baseline was 50 ± 8 years and 7973 (32 %) were women. During a median follow-up of 9 years (IQR 3-16) and 256,279 person years, 2045 (8.2 %) participants were diagnosed with cancer. Multivariable Cox model showed a 1.2 (95 %CI: 1.0-1.4 p = 0.05), 1.2 (95 %CI: 1.0-1.4 p = 0.02), and 1.4 (95 %CI: 1.1-1.7 p = 0.003) higher risk for cancer with eGFR of 75-89, 60-74, and < 60, respectively. Site-specific analysis demonstrated a 1.8 (95 %CI: 1.2-2.6 p = 0.004), 1.7 (95 %CI: 1.2-2.6 p = 0.004) and 2.2 (95 %CI: 1.3-3.6 p = 0.002) increased risk for prostate cancer with eGFR of 75-89, 60-74, and < 60, respectively. eGFR< 60 was associated with a 2.0 (95 %CI: 1.1-3.7 p = 0.03) and 3.7 (95 %CI: 1.1-13.1 p = 0.04) greater risk for melanoma and gynecological caner respectively. CONCLUSIONS: CKD stage 2 and worse is independently associated with higher risk for cancer incidence, primarily prostate cancer. Early intervention and screening are warranted among these individuals in order to reduce cancer burden.

16.
Nutrients ; 15(9)2023 Apr 22.
Article in English | MEDLINE | ID: mdl-37432174

ABSTRACT

BACKGROUND: In the face of the global pandemic that the coronavirus disease 2019 (COVID-19) has created, readily available prognostic markers may be of great use. OBJECTIVE: To evaluate the association between serum magnesium (sMg) levels on admission and clinical outcomes in hospitalized COVID-19 patients. METHODS: We retrospectively analyzed all patients admitted to a single tertiary center with a primary de novo diagnosis of COVID-19. Patients were followed for a mean of 10 ± 7 months. Demographic, clinical and laboratory data were collected and compared between five groups of patients according to sMg quintiles on hospital admission. RESULTS: The cohort included 1522 patients (58% male, 69 ± 17 years old). A low sMg level (1st quintile) was associated with higher rates of diabetes and steroid use, whereas a high sMg level (5th quintile) was associated with dyslipidemia, renal dysfunction, higher levels of inflammatory markers and stay in the intensive care unit. All-cause in-hospital and long-term mortality was higher in patients with both low and high sMg levels, compared with mid-range sMg levels (2nd, 3rd and 4th quintiles; 19% and 30% vs. 9.5%, 10.7% and 17.8% and 35% and 45.3% vs. 23%, 26.8% and 27.3% respectively; p < 0.001 for all). After adjusting for significant clinical parameters indicating severe disease and renal dysfunction, only low sMg state was independently associated with increased mortality (HR = 1.57, p < 0.001). CONCLUSIONS: Both low and high sMg levels were associated with increased mortality in a large cohort of hospitalized COVID-19 patients. However, after correction for renal dysfunction and disease severity, only low sMg maintained its prognostic ability.


Subject(s)
COVID-19 , Kidney Diseases , Humans , Male , Middle Aged , Aged , Aged, 80 and over , Female , Magnesium , Retrospective Studies , Hospitalization
17.
Coron Artery Dis ; 34(6): 410-414, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37471280

ABSTRACT

BACKGROUND: The ridaforolimus-eluting stent (RES) system is a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting ridaforolimus. The aim of this trial was to assess the performance of a 38 mm RES in long coronary lesions. METHODS: A prospective, multicenter, single-arm, open-label clinical trial. Clinical follow-up was performed at 30 days, 6 months, and 1 year after the procedure. Target lesions were located in native coronary arteries or bypass graft conduits, with visually estimated diameters of ≥2.75 mm to ≤4.25 mm. The primary endpoint was combined efficacy (final in-stent residual diameter stenosis <30%) without 30-day major adverse cardiovascular events (MACE) (composite of cardiac death, any myocardial infarction), or ischemia-driven target lesion revascularization. RESULTS: A total of 50 patients were enrolled in the study. Fourteen (28%) had acute coronary syndromes; 17 (34%) had diabetes. The mean lesion length was 32.4 mm ±â€…8.3, reference vessel diameter 2.88 mm ±â€…0.45, minimal lumen diameter 0.80 mm ±â€…0.41, and percent diameter stenosis 72.6% ±â€…13.2. The primary endpoint was achieved in 88% (44/50) of the patients (95% confidence interval: 75.7-95.5%). Thirty-day and 1-year MACE rates were 6% and 8%, respectively. Target lesion failure after 1 year occurred in three patients (6%). Forty-seven lesions (94%) were treated successfully, with final in-stent diameter stenosis of < 30% [95% confidence interval: (84-99%). CONCLUSION: Percutaneous coronary intervention (PCI) of long lesions with a 38 mm RES achieved satisfactory results, and support the safety and efficacy of PCI with RES in patients with long lesions. (ClinicalTrials.gov NCT03702608).


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/etiology , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Constriction, Pathologic , Prospective Studies , Bionics , Stents , Treatment Outcome
18.
J Heart Lung Transplant ; 42(8): 1054-1058, 2023 08.
Article in English | MEDLINE | ID: mdl-37084801

ABSTRACT

In 2022, the antigenically divergent SARS-CoV-2 omicron variants (BA.1, BA.2, BA.4, BA.5) outcompeted previous variants and continued to cause substantial numbers of illnesses and deaths. We evaluated the safety and immunogenicity of the bivalent original/omicron BA.4/BA.5 Pfizer/BioNTech vaccine administered as a fifth dose to heart transplant recipients (HTxRs). We compared neutralization (using live virus assays) of SARS-CoV-2-infected cells in serum samples from HTxRs who had previously received 4 doses of the monovalent BNT162b2 vaccine with samples from HTxRs with breakthrough infection after 4 monovalent BNT162b2 doses. The fifth vaccination induced high neutralization efficiency against the wild-type virus and omicron BA.1, BA.2, BA.4, and BA.5 variants, with significantly higher neutralization efficiency being induced in HTxRs with breakthrough infection than in those without. Neutralizing titers in those with breakthrough infection were sustained above the level induced by the fifth dose in the uninfected. We conclude that the fifth bivalent vaccine is immunogenic, including to variants, with higher vaccine immunogenicity conferred by breakthrough infection. Nevertheless, the clinical protection conferred by the fifth dose is yet to be determined. The sustained neutralization responses in those with breakthrough infection support the notion of delaying booster in those with natural breakthrough infection.


Subject(s)
COVID-19 , Heart Transplantation , Humans , BNT162 Vaccine , COVID-19/prevention & control , SARS-CoV-2 , Vaccination , Breakthrough Infections , Antibodies, Viral
19.
Eur J Prev Cardiol ; 30(7): 524-532, 2023 05 09.
Article in English | MEDLINE | ID: mdl-36378558

ABSTRACT

AIMS: This study evaluated the impact of serum uric acid (sUA) on the accuracy of pooled cohort equations (PCE) model, Systematic COronary Risk Evaluation 2 (SCORE2), and SCORE2-older persons. METHODS AND RESULTS: We evaluated 19 769 asymptomatic self-referred adults aged 40-79 years free of cardiovascular disease and diabetes who were screened annually in a preventive healthcare setting. sUA levels were expressed as a continuous as well as a dichotomous variable (upper sex-specific tertiles defined as high sUA). The primary endpoint was the composite of death, acute coronary syndrome, or stroke, after excluding subjects diagnosed with metastatic cancer during follow-up. Mean age was 50 ± 8 years and 69% were men. During the median follow-up of 6 years, 1658 (8%) subjects reached the study endpoint. PCE, SCORE2, and high sUA were independently associated with the study endpoint in a multivariable model (P < 0.001 for all). Continuous net reclassification improvement analysis showed a 13% improvement in the accuracy of classification when high sUA was added to either PCE or SCORE2 model (P < 0.001 for both). sUA remained independently associated with the study endpoint among normal-weight subjects in the SCORE2 model (HR 1.3, 95% CI 1.1-1.6) but not among overweight individuals (P for interaction = 0.01). Subgroup analysis resulted in a significant 16-20% improvement in the model performance among normal-weight and low-risk subjects (P < 0.001 for PCE; P = 0.026 and P < 0.001 for SCORE2, respectively). CONCLUSION: sUA significantly improves the classification accuracy of PCE and SCORE2 models. This effect is especially pronounced among normal-weight and low-risk subjects.


Subject(s)
Acute Coronary Syndrome , Cardiovascular Diseases , Adult , Male , Female , Humans , Aged , Aged, 80 and over , Middle Aged , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/prevention & control , Risk Factors , Uric Acid , Heart Disease Risk Factors
20.
Cardiol J ; 30(3): 422-430, 2023.
Article in English | MEDLINE | ID: mdl-34581429

ABSTRACT

BACKGROUND: While the combination of a small aortic valve area (AVA) and low mean gradient is frequently labeled 'low-flow low-gradient aortic stenosis (AS)', there are two potential causes for this finding: underestimation of mean gradient and underestimation of AVA. METHODS: In order to investigate the prevalence and causes of discordant echocardiographic findings in symptomatic patients with AS and normal left ventricular (LV) function, we evaluated 72 symptomatic patients with AS and normal LV function by comparing Doppler, invasive, computed tomography (CT) LV outflow tract (LVOT) area, and calcium score (CaSc). RESULTS: Thirty-six patients had discordant echocardiographic findings (mean gradient < 40 mmHg, AVA ≤ 1 cm²). Of those, 19 had discordant invasive measurements (true discordant [TD]) and 17 concordant (false discordant [FD]): In 12 of the FD the mean gradient was > 30 mmHg; technical pitfalls were found in 10 patients (no reliable right parasternal Doppler in 6). LVOT area by echocardiography or CT could not differentiate between concordants and discordants nor between TD and FD (p = NS). CaSc was similar in concordants and FD (p = 0.3), and it was higher in true concordants than in TD (p = 0.005). CaSc positive predictive value for the correct diagnosis of severe AS was 95% for concordants and 93% for discordants. CONCLUSIONS: Discordant echocardiographic findings are commonly found in patients with symptomatic AS. Underestimation of the true mean gradient due to technical difficulties is an important cause of these discrepant findings. LVOT area by echocardiography or CT cannot differentiate between TD and FD. In the absence of a reliable and compete multi-window Doppler evaluation, patients should undergo CaSc assessment.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Echocardiography , Ventricular Function, Left , Severity of Illness Index , Stroke Volume
SELECTION OF CITATIONS
SEARCH DETAIL
...