Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 46
Filter
1.
J Thromb Haemost ; 2024 May 23.
Article in English | MEDLINE | ID: mdl-38795872

ABSTRACT

Prothrombin time (PT) and its derivative international normalized ratio (INR) are frequently ordered to assess the coagulation system. Plasma transfusion to treat incidentally abnormal PT/INR is a common practice with low biological plausibility and without credible evidence, yet INR targets appear in major clinical guidelines and account for the majority of plasma use at many institutions. In this article, we review the historical origins of INR targets. We recount historical milestones in the development of the PT, discovery of vitamin K antagonists (VKAs), motivation for INR standardization, and justification for INR targets in patients receiving VKA therapy. Next, we summarize evidence for INR testing to assess bleeding risk in patients not on VKA therapy and plasma transfusion for treating mildly abnormal INR to prevent bleeding in these patients. We conclude with a discussion of the parallels in misunderstanding of historic PT and present-day INR testing with lessons from the past that might help rationalize plasma transfusion in the future.

3.
Res Pract Thromb Haemost ; 8(3): 102385, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38623474

ABSTRACT

Lupus anticoagulant (LA) represents 1 of the laboratory criteria for classification of patients as having definite antiphospholipid syndrome (APS). The other 2 laboratory criteria are anticardiolipin antibodies and anti-beta2-glycoprotein I antibodies. At least 1 of these antiphospholipid antibody (aPL) tests need to be positive, with evidence of persistence, together with evidence of at least 1 clinical criterion for APS, before a patient can be classified as having definite APS. LA and other aPL assays are also important for diagnosis or exclusion of APS, as well as for risk stratification, with triple-positive patients carrying the greatest risk. Whereas LA is identified through "uncalibrated" clot-based assays, the other aPL assays (anticardiolipin and anti-beta2-glycoprotein I antibodies) represent immunological assays, identified using calibrated solid-phase methods. Because LA is identified using clot-based assays, it is subject to considerable preanalytical and analytical issues that challenge accurate detection or exclusion of LA. In this narrative review, we take a look at the good, the bad, and the ugly of LA testing, primarily focusing on the last 10 years. Although harmonization of LA testing as a result of International Society on Thrombosis and Haemostasis guidance documents and other international activities has led to improvements in LA detection, many challenges remain. In particular, several anticoagulants, especially direct oral anticoagulants and also vitamin K antagonists, given as therapy to treat the pathophysiological consequences of aPL, especially thrombosis, interfere with LA assays and can generate false-positive or false-negative LA findings. Overcoming these diagnostic errors will require a multifaceted approach with clinicians and laboratories working together.

4.
Res Pract Thromb Haemost ; 8(1): 102335, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38433976

ABSTRACT

A State of the Art lecture titled "D-dimer Diagnostics: Can I use any D-dimer assay? Bridging the Knowledge-to-Action gap" was presented at the International Society on Thrombosis and Haemostasis Congress in 2023, included in the session on the clinical impact of variability in commonly used coagulation assays. Here, we review the role of D-dimer, primarily in the outpatient diagnosis of patients with venous thromboembolism (VTE) when combined with clinical decision rules. We focus on the recent large management trials that have studied adjustments of VTE exclusion thresholds for D-dimer based on either prior clinical probability of VTE or patient age, and the resultant benefit of reduced imaging for VTE and improved diagnostic efficiency. In this context, we report on the significant variability between D-dimer results and the multiple D-dimer assays in use worldwide using data from international external quality assurance programs. This variability is particularly high at typical VTE exclusion thresholds. We discuss the potential clinical impact of D-dimer assay substitution on accuracy of diagnosis and risk stratification of patients with VTE. Finally, we summarize relevant new data on this topic presented during the 2023 International Society on Thrombosis and Haemostasis Congress and outline future priorities urgently needed to harmonize D-dimer results and reporting that will require international collaboration among multiple stakeholders with an overall goal to close this knowledge-to-action gap.

5.
Res Pract Thromb Haemost ; 7(4): 100193, 2023 May.
Article in English | MEDLINE | ID: mdl-37538494

ABSTRACT

This year's Congress of the International Society of Thrombosis and Haemostasis (ISTH) took place in person in Montréal, Canada, from June 24-28, 2023. The conference, held annually, highlighted cutting-edge advances in basic, translational, population and clinical sciences relevant to the Society. As for all ISTH congresses, we offered a special, congress-specific scientific theme; this year, the special theme was immunothrombosis. Certainly, over the last few years, COVID-19 infection and its related thrombotic and other complications have renewed interest in the concepts of thromboinflammation and immunothrombosis; namely, the relationship between inflammation, infection and clotting. Other main scientific themes of the Congress included Arterial Thromboembolism, Coagulation and Natural Anticoagulants, Diagnostics and Omics, Fibrinolysis and Proteolysis, Hemophilia and Rare Bleeding Disorders, Hemostatic System in Cancer, Inflammation and Immunity, Pediatrics, Platelet Disorders, von Willebrand Disease and Thrombotic Microangiopathies, Platelets and Megakaryocytes, Vascular Biology, Venous Thromboembolism and Women's Health. Among other sessions, the program included 28 State-of-the-Art (SOA) sessions with a total of 84 talks given by internationally recognized leaders in the field. SOA speakers were invited to prepare brief illustrated reviews of their talks that were peer reviewed and are included in this article. These illustrated capsules highlight the major scientific advances with potential to impact clinical practice. Readers are invited to take advantage of the excellent educational resource provided by these illustrated capsules. They are also encouraged to use the image in social media to draw attention to the high quality and impact of the science presented at the Congress.

6.
BMJ Open Qual ; 12(2)2023 05.
Article in English | MEDLINE | ID: mdl-37217241

ABSTRACT

BACKGROUND: Excessive use of CT pulmonary angiography (CTPA) to investigate pulmonary embolism (PE) in the emergency department (ED) contributes to adverse patient outcomes. Non-invasive D-dimer testing, in the context of a clinical algorithm, may help decrease unnecessary imaging but this has not been widely implemented in Canadian EDs. AIM: To improve the diagnostic yield of CTPA for PE by 5% (absolute) within 12 months of implementing the YEARS algorithm. MEASURES AND DESIGN: Single centre study of all ED patients >18 years investigated for PE with D-dimer and/or CTPA between February 2021 and January 2022. Primary and secondary outcomes were the diagnostic yield of CTPA and frequency of CTPA ordered compared with baseline. Process measures included the percentage of D-dimer tests ordered with CTPA and CTPAs ordered with D-dimers <500 µg/L Fibrinogen Equivalent Units (FEU). The balancing measure was the number of PEs identified on CTPA within 30 days of index visit. Multidisciplinary stakeholders developed plan- do-study-act cycles based on the YEARS algorithm. RESULTS: Over 12 months, 2695 patients were investigated for PE, of which 942 had a CTPA. Compared with baseline, the CTPA yield increased by 2.9% (12.6% vs 15.5%, 95% CI -0.06% to 5.9%) and the proportion of patients that underwent CTPA decreased by 11.4% (46.4% vs 35%, 95% CI -14.1% to -8.8%). The percentage of CTPAs ordered with a D-dimer increased by 26.3% (30.7% vs 57%, 95% CI 22.2% 30.3%) and there were two missed PE (2/2695, 0.07%). IMPACT: Implementing the YEARS criteria may safely improve the diagnostic yield of CTPAs and reduce the number of CTPAs completed without an associated increase in missed clinically significant PEs. This project provides a model for optimising the use of CTPA in the ED.


Subject(s)
Pulmonary Embolism , Humans , Canada , Pulmonary Embolism/diagnostic imaging , Emergency Service, Hospital , Algorithms
7.
PLoS One ; 18(4): e0284425, 2023.
Article in English | MEDLINE | ID: mdl-37071625

ABSTRACT

BACKGROUND: Despite the fact that direct oral anticoagulants (DOACs) are favoured over warfarin for stroke prevention in patients with non-valvular atrial fibrillation (NVAF), physicians need to maintain competence in using and monitoring warfarin since many patients have contraindications or other barriers to using DOACs. Unlike DOACs, warfarin therapy requires regular blood testing to ensure that it is within a target range to ensure efficacy and safety. There is limited real-world data on the adequacy of warfarin control and the cost and burden of monitoring warfarin therapy in Canadian NVAF patients. OBJECTIVES: In a large cohort of Canadian patients with NVAF on warfarin we assessed time in therapeutic range (TTR), determinants of TTR, process of care, direct costs, health related quality of life and loss of work time and productivity related to warfarin therapy. METHODS: Five hundred and fifty one patients with NVAF, either newly initiated or stable on warfarin were prospectively enrolled across 9 Canadian provinces from primary care practices and anticoagulant clinics. Participating physicians provided baseline demographic and medical information. Patients completed diaries for 48 weeks, capturing information about International Normalized Ratio (INR) test results, test locations, process of INR monitoring, direct costs of travel, health-related quality of life and work productivity measures. TTR was estimated using linear interpolation of INR results and linear regression used to investigate associations between TTR and factors (defined a priori). RESULTS: Four hundred and eighty (87.1%) patients had complete follow-up with an overall TTR of 74.4% based on 7,175 physician-reported INR values from 501 patients. 88% of this cohort were monitored through routine medical care (RMC). The average number of INRs per patient during the 48-week period was 14.1 (standard deviation (SD) = 8.3) tests with a mean duration of 23.8 (SD = 11.1) days between tests. We did not find a relationship between TTR and age, sex, presence of major comorbidities, patient's province of residence or rural vs. urban residence. 12% of patients monitored through anticoagulant clinics had significantly better TTR than patients monitored through RMC (82% vs. 74%; 95% confidence interval: -13.8, -1.2; p = 0.02). Health related quality of life utility values were high and remained consistent throughout the study. The majority of patients reported no impact on either work productivity or impairment of regular activities due to being on long-term warfarin treatment. CONCLUSIONS: We showed excellent overall TTR in an observed Canadian cohort, with monitoring through a dedicated anticoagulant clinic being associated with a statistically and clinically significant improvement in TTR. The burden of warfarin therapy on patients' health related quality of life or daily work and activities was low.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Warfarin/adverse effects , Atrial Fibrillation/complications , Prospective Studies , Quality of Life , Canada/epidemiology , Retrospective Studies , Anticoagulants/adverse effects , International Normalized Ratio , Patient Outcome Assessment , Stroke/complications
8.
Res Pract Thromb Haemost ; 7(1): 100022, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36970744
9.
Semin Thromb Hemost ; 48(6): 700-710, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36122573

ABSTRACT

Accurate diagnosis of von Willebrand disease (VWD) depends on the quality, precision, and variability of the laboratory assays. The North American Specialized Coagulation Laboratory Association (NASCOLA) is a provider of external quality assessment (EQA) for approximately 60 specialized coagulation laboratories in North America. In this report, NASCOLA EQA data from 2010 to 2021 are reviewed for trends in methodology and precision among various assays. In particular, recent ASH ISTH NHF WFH (American Society of Hematology, International Society on Thrombosis and Haemostasis, National Hemophilia Foundation, and World Hemophilia Federation) guidelines for diagnosis of VWD are reviewed in light of EQA data. In contrast to other geographic regions, laboratories in North America predominantly use three-assay screening panels (antigen, platelet-binding activity, and factor VIII [FVIII] activity) rather than four-assay panels (antigen, platelet-binding activity, FVIII activity, and collagen-binding activity). They also use latex immunoassays rather than chemiluminescence immunoassays, and the classic ristocetin cofactor (VWF:RCo) assay and monoclonal antibody (VWF:Ab) assay to assess VWF platelet-binding activity over newer recommended assays (VWF:GPIbM and VWF:GPIbR). Factors that may be influencing these North American practice patterns include lack of Food and Drug Administration approval of the VWF:GPIbM, VWF:GPIbR, collagen binding assays, and chemiluminescence methodologies, and the influence of the 2008 National Heart, Lung, and Blood Institute guidelines on laboratory practice. Lastly, systems-based solutions are urgently needed to improve the overall accuracy of laboratory testing for VWD by minimizing preanalytical variables and adopting assay standardization.


Subject(s)
von Willebrand Diseases , Antibodies, Monoclonal , Blood Coagulation Tests/methods , Collagen/metabolism , Factor VIII , Humans , Laboratories , von Willebrand Diseases/diagnosis , von Willebrand Factor/metabolism
10.
Article in English | MEDLINE | ID: mdl-35755855

ABSTRACT

Background: Coagulation testing provides a prime opportunity to make an impact on the reduction of unnecessary laboratory test ordering, as there are clear indications for testing. Despite the prothrombin time/international normalized ratio and activated partial thromboplastin time being validated for specific clinical indications, they are frequently ordered as screening tests and often ordered together, suggesting a gap in understanding of coagulation. Methods: Based on a needs assessment, we developed an online educational module on coagulation for trainees, incorporating education on testing cost, specificity, and sensitivity. Fifty participating resident physicians and medical students completed a validated premodule quiz, postmodule quiz after completion of the module, and a latent quiz 3 to 6 months after to assess longer-term knowledge retention. Trainees provided responses regarding their subjective laboratory test-ordering practices before and after module completion. Results: The median premodule quiz score was 67% (n = 50; range, 24%-86%) with an increase of 24% to a median postmodule quiz score of 91% (n = 50; range, 64%-100%). There was evidence of sustained knowledge acquisition with a latent quiz median score of 89% (n = 40; range, 67%-100%). Trainees were more likely to consider the sensitivity, specificity, and cost of laboratory investigations before ordering them following completion of the educational module. Conclusions: Using the expertise of medical educators and incorporating trainee feedback, we employed a novel approach to the teaching of coagulation to maximize its approachability and clinical relevance. We found sustained knowledge retention regarding coagulation and appropriate coagulation test ordering, and a subjective change to trainee ordering habits following participation in our educational intervention.

12.
Semin Thorac Cardiovasc Surg ; 34(1): 315-323, 2022.
Article in English | MEDLINE | ID: mdl-33984481

ABSTRACT

Pulmonary endarterectomy (PEA) is the main treatment for chronic thromboembolic pulmonary hypertension (CTEPH). Postoperative unfractionated heparin dosing can be monitored by activated partial thromboplastin time (APTT) or by anti-factor Xa activity (anti-Xa). In pseudo heparin resistance, APTT response to heparin is blunted due to elevated Factor VIII (FVIII) which can underestimate anticoagulation. We examined possible pseudo heparin resistance after PEA and assessed the impact of FVIII. APTT response to heparin before and after operation was determined in 13 PEA patients anticoagulated with unfractionated heparin. APTT and anti-Xa concordance was analyzed from paired postoperative samples, and antithrombin, fibrinogen and FVIII levels were measured. Single-cell RNA sequencing was used to characterize FVIII gene expression in PEA specimens of 5 patients. APTT response to heparin was blunted after PEA. APTT and anti-Xa were discordant in 36% of postoperative samples and most common discordant patterns were subtherapeutic APTT with therapeutic (16%) or supratherapeutic (11%) anti-Xa. Overall, APTT underestimated anticoagulation relative to anti-Xa in one-third of the samples. FVIII levels were elevated before surgery, increased substantially 1 and 3 days (median 4.32 IU/mL) after PEA, and were higher in discordant than concordant samples. Single-cell RNA sequencing showed FVIII gene expression in PEA specimen endothelial cells. Pseudo heparin resistance is common after PEA likely due to highly elevated postoperative FVIII levels indicating that anti-Xa reflects postoperative heparinization better than APTT in these patients. FVIII production by the pulmonary artery endothelium may participate in local prothrombotic processes important for CTEPH pathogenesis.


Subject(s)
Hemostatics , Thrombosis , Anticoagulants/therapeutic use , Endarterectomy/adverse effects , Endothelial Cells/metabolism , Factor VIII/metabolism , Factor Xa Inhibitors/therapeutic use , Heparin , Humans , Thrombosis/etiology , Thrombosis/surgery , Treatment Outcome
13.
J Thromb Thrombolysis ; 53(3): 690-696, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34613576

ABSTRACT

Thrombotic antiphospholipid syndrome (TAPS) is an autoimmune disorder that manifests with venous thromboembolism (VTE) and/or arterial thromboembolism (ATE) in the presence of persistent antiphospholipid antibodies (aPLs). Recent trials have failed to demonstrate non-inferiority of the direct oral anticoagulants (DOACs) compared to vitamin K antagonists as anticoagulation in TAPS, but there is a subgroup of non-triple positive patients without prior ATE in who only limited data exists. The objective of this study was to assess the effectiveness and safety of DOACs in non-triple positive TAPS without prior ATE. We conducted a retrospective review of all non-triple positive TAPS patients without prior ATE who were anticoagulated with a DOAC at two tertiary care hospitals from January 2010 to July 2020. We assessed outcomes of VTE, ATE, major bleeding, and clinically relevant non-major bleeding (CRNMB). 50 patients were included in the analysis, encompassing 157.2 years of patient follow-up. There were no recurrent VTE, but one patient had a possible arterial thrombosis (0.64 events per 100 patient-years [95% confidence interval (CI 0.16-35.49)] as a transient ischemic attack (TIA) which occurred on reduced dose DOAC. There were no major bleeding events, but two patients had CRNMB (1.27 events per 100 patient-years [95% CI 1.5-46.0]), both as menorrhagia. DOACs were effective and safe as anticoagulation in non-triple positive TAPS patients without prior ATE with a low rate of recurrent thrombosis and bleeding. Larger, prospective controlled studies are required to confirm these findings prior to routine use of DOACs in this subgroup.


Subject(s)
Antiphospholipid Syndrome , Thrombosis , Venous Thromboembolism , Administration, Oral , Anticoagulants/adverse effects , Antiphospholipid Syndrome/complications , Antiphospholipid Syndrome/drug therapy , Female , Hemorrhage/chemically induced , Hemorrhage/drug therapy , Humans , Prospective Studies , Thrombosis/drug therapy , Venous Thromboembolism/drug therapy
14.
Haemophilia ; 27(6): e713-e720, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34455654

ABSTRACT

BACKGROUND: Laboratory diagnosis of von Willebrand Disease (VWD) is complex. Reliance on laboratory testing can be problematic as different VWD screening panels, assays and methodologies can produce analytic variability in test results. OBJECTIVES: To compare the degree of imprecision among the VWD assays and within the platelet binding activity (PBA) assays, to determine the consensus among the VWD assays for correct classification of sample results, and to determine consensus among laboratories' von Willebrand factor (VWF) multimer interpretations and final interpretations of the VWD panels. PATIENTS/METHODS: Proficiency testing results from the North American Specialized Coagulation Laboratory Association (NASCOLA) submitted by laboratories from 2010 to 2019 for all normal, type (T) 1 VWD and T2 VWD samples were analysed. RESULTS AND CONCLUSIONS: Imprecision was lowest for VWF antigen and highest for collagen binding activity (CBA) with median coefficient of variation (CV) of 12% (interquartile range (IQR) 7%) and 23% (IQR 21%) respectively. Within the VWF PBA assays, the gain-of-function mutant GP1b binding (VWF: GP1bM) methods had the least imprecision (CV 9%, IQR 10%). All assays, including the various PBA methods had excellent consensus. The majority of laboratories agreed that normal (median consensus-82%, IQR 16%) and T1 VWD (median consensus-100%, IQR 9%) samples had normal multimer distribution. Consensus among laboratories for final interpretations was excellent for normal samples (median 81%, IQR 8%), good for T1 VWD samples (median 59%, IQR 9%), and fair for T2 VWD samples (median 44%, IQR 21%). Consensus on final interpretation decreased as sample complexity increased.


Subject(s)
von Willebrand Diseases , Blood Coagulation Tests , Humans , Laboratories , North America , von Willebrand Diseases/diagnosis , von Willebrand Factor
15.
Res Pract Thromb Haemost ; 5(5): e12535, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34401639

ABSTRACT

BACKGROUND: Idarucizumab, a monoclonal antibody fragment that reverses the anticoagulant effect of dabigatran, was approved for use in Canada in 2016. OBJECTIVE: Our objective was to assess the safety of idarucizumab among patients who received the drug within the first 3 years of its use in Canada. PATIENTS/METHODS: We performed a retrospective health records review of all idarucizumab use, excluding use in those <18 years of age, between May 16, 2016, and August 1, 2019, at six Ontario tertiary care hospitals. The primary outcome was mortality. The secondary outcomes were in-hospital arterial thrombotic event (ATE), in-hospital venous thromboembolism (VTE), length of hospital stay, and length of critical care stay. RESULTS: A total of 85 patients received idarucizumab during the study period for the following indications: 37 (43.5%) for spontaneous bleeding, 28 (32.9%) for traumatic bleeding, 11 (12.9%) for emergency surgeries/procedures, 5 (5.9%) for elective surgeries/procedures, and 4 (4.7%) for other indications. Nineteen patients (22.4%; 95% confidence interval [CI], 14.8%-32.3%) did not survive their hospitalization. During hospitalization, two patients (2.4%; 95% CI, 0.7%-8.2%) had ATE, and three patients (3.5%; 95% CI, 1.2%-9.9%) had VTE. The median length of stay was 8 (interquartile range [IQR], 2.5-13) days in hospital and 3 (IQR, 2-5) days in critical care. CONCLUSIONS: Compared with clinical trial data, we found a numerically higher rate of mortality and similar rate of ATE and VTE among patients treated with idarucizumab in the real world.

19.
Hematology Am Soc Hematol Educ Program ; 2020(1): 67-75, 2020 12 04.
Article in English | MEDLINE | ID: mdl-33275705

ABSTRACT

Viscoelastic assays (VEAs) that include thromboelastography and rotational thromboelastometry add value to the investigation of coagulopathies and goal-directed management of bleeding by providing a complete picture of clot formation, strength, and lysis in whole blood that includes the contribution of platelets, fibrinogen, and coagulation factors. Conventional coagulation assays have several limitations, such as their lack of correlation with bleeding and hypercoagulability; their inability to reflect the contribution of platelets, factor XIII, and plasmin during clot formation and lysis; and their slow turnaround times. VEA-guided transfusion algorithms may reduce allogeneic blood exposure during and after cardiac surgery and in the emergency management of trauma-induced coagulopathy and hemorrhage. However, the popularity of VEAs for other indications is driven largely by extrapolation of evidence from cardiac surgery, by the drawbacks of conventional coagulation assays, and by institution-specific preferences. Robust diagnostic studies validating and standardizing diagnostic cutoffs for VEA parameters and randomized trials comparing VEA-guided algorithms with standard care on clinical outcomes are urgently needed. Lack of such studies represents the biggest barrier to defining the role and impact of VEA in clinical care.


Subject(s)
Algorithms , Blood Transfusion , Cardiac Surgical Procedures , Hemorrhage , Thrombelastography , Thrombophilia , Blood Platelets/metabolism , Factor XIII/metabolism , Fibrinolysin/metabolism , Hemorrhage/blood , Hemorrhage/diagnosis , Hemorrhage/therapy , Humans , Thrombophilia/blood , Thrombophilia/diagnosis , Thrombophilia/therapy
20.
Thromb Res ; 191 Suppl 1: S26-S30, 2020 07.
Article in English | MEDLINE | ID: mdl-32736774

ABSTRACT

Coagulation biomarkers are being actively studied for their diagnostic and prognostic value in patients with venous thromboembolism and cancer, as well as in the study of pathogenic mechanisms between cancer and thrombosis. For the results of such studies to be accurate and reproducible, attention must be paid to minimize sources of error in all phases of testing. The pre-analytical phase of laboratory testing is known to be fraught with the majority of errors. Coagulation testing is particularly susceptible to conditions during collection, processing, transport and storage of specimens which can lead to clinically significant errors in results. In addition, changes in pre-analytical conditions can impact different biomarkers differently. Therefore, research studies investigating coagulation biomarkers must carefully standardize not just the analytical phase, but also the pre-analytical phase of testing to ensure accuracy and reliability. We briefly review the impact of pre-analytical conditions on coagulation testing in general, and on specific biomarkers in cancer and thrombosis. In addition, we provide recommendations to reduce pre-analytical errors by developing and sharing standard operating procedures that specifically target standardization of methodologies for collecting specimens and measuring current and emerging coagulation biomarkers in cancer studies.


Subject(s)
Neoplasms , Thrombosis , Biomarkers , Blood Coagulation , Humans , Neoplasms/complications , Reproducibility of Results , Thrombosis/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...