Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Hazard Mater ; 439: 129641, 2022 10 05.
Article in English | MEDLINE | ID: mdl-35882172

ABSTRACT

Nitrification of centrate from anaerobic sewage sludge digestion presents a major opportunity as an electron acceptor in anoxic biogas biodesulphurisation. Nitritation and nitrification inhibition by free ammonia was detected at laboratory scale, but was avoided during the scale-up operation in a 4 m3 reactor treating ammonium loads up to 19 gN m-3 h-1. This nitrate-rich stream was fed to two pilot-scale suspended biomass bioreactors (SBBs) treating real biogas for 220 days. After an adaptation period of 21 days, nitrate and alkalinity concentrations in the liquid medium below 10 mgN L-1 and 100 mgCaCO3 L-1 were found to limit hydrogen sulphide (H2S) oxidation. Once controlled, 95% of the H2S was removed in SBB1 and 90% in SBB2, at a gas residence time (GRT) of 5.9 min, treating average values of 321 ± 205 ppmv and 457 ± 205 ppmv, respectively. Outlet H2S concentrations of 16 ± 24 ppmv in SBB1 and 46 ± 39 ppmv in SBB2 were obtained, which are below the requirements of biogas combustion heat and power engines. Unlike H2S, siloxanes were not removed with these GRTs. The results demonstrate the feasibility of the combined process for H2S treatment, potential valorisation of precipitated elemental sulphur and a reduction in the reagents currently used to control H2S.


Subject(s)
Biofuels , Nitrates , Anaerobiosis , Biofuels/analysis , Biomass , Bioreactors , Nitrogen , Sewage
2.
Bioprocess Biosyst Eng ; 36(7): 975-84, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23053419

ABSTRACT

This paper investigates the removal of isopropanol by gas-phase biotrickling filtration. Two plastic packing materials, one structured and one random, have been evaluated in terms of oxygen mass transfer and isopropanol removal efficiency. Oxygen mass transfer experiments were performed at gas velocities of 104 and 312 m h⁻¹ and liquid velocities between 3 and 33 m h⁻¹. Both materials showed similar mass transfer coefficients up to liquid velocities of 15 m h⁻¹. At greater liquid velocities, the structured packing exhibited greater oxygen mass transfer coefficients. Biotrickling filtration experiments were carried out at inlet loads (IL) from 20 to 65 g C m⁻³ h⁻¹ and empty bed residence times (EBRT) from 14 to 160 s. To simulate typical industrial emissions, intermittent isopropanol loading (16 h/day, 5 day/week) and intermittent spraying frequency (15 min/1.5 h) were applied. Maximum elimination capacity of 51 g C m⁻³ h⁻¹ has been obtained for the random packing (IL of 65 g C m⁻³ h⁻¹, EBRT of 50 s). The decrease in irrigation frequency to 15 min every 3 h caused a decrease in the outlet emissions from 86 to 59 mg C Nm⁻³ (inlet of 500 mg C Nm⁻³). The expansion of spraying to night and weekend periods promoted the degradation of the isopropanol accumulated in the water tank during the day, reaching effluent concentrations as low as 44 mg C Nm⁻³. After a 7-week starvation period, the performance was recovered in less than 10 days, proving the robustness of the process.


Subject(s)
2-Propanol/isolation & purification , Filtration/methods , Oxygen/metabolism
3.
Article in English | MEDLINE | ID: mdl-22486666

ABSTRACT

Two biotrickling filters were set up at two wastewater treatment plants (WWTP) in The Netherlands to investigate their effectiveness for treatment of odorous waste gases from different sources. One biotrickling filter was installed at Nieuwe Waterweg WWTP in Hook of Holland to study the hydrogen sulfide removal from headworks waste air. The other reactor was installed at Harnaschpolder WWTP (treating wastewater of the city of The Hague) to remove mercaptans and other organic compounds (odor) coming from the emissions of the anaerobic tanks of the biological nutrient removal (BNR) activated sludge. The performance of both units showed a stable and highly efficient operation under seasonal variations of load and temperature over nearly one year of monitoring. The Nieuwe Waterweg unit achieved removals of up to 99%, corresponding to a maximum daily average elimination capacity (EC) of 55.8 g H(2)S/m(3)/h at an empty bed residence time (EBRT) as short as 8.5 s. Odor reduction at the Harnaschpolder unit was 95% at an EBRT of 18.9 s, with average outlet concentration lower than the objective value which was established as 1000 European Odor Units (OU(E)/m(3)).


Subject(s)
Air Pollutants/chemistry , Air Pollutants/metabolism , Air Pollution/prevention & control , Bioreactors/microbiology , Filtration/methods , Anaerobiosis , Biodegradation, Environmental , Filtration/instrumentation , Hydrogen Sulfide/chemistry , Hydrogen Sulfide/metabolism , Netherlands , Odorants/analysis , Pilot Projects , Sodium Hydroxide/chemistry , Volatile Organic Compounds/chemistry , Volatile Organic Compounds/metabolism , Waste Disposal, Fluid
4.
Bioprocess Biosyst Eng ; 34(7): 859-67, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21442419

ABSTRACT

The removal of styrene-polluted air emissions by biotrickling filtration was performed to evaluate the influence of using nitrate and urea as a nitrogen source in the nutrient solution supplied to two bioreactors run in parallel under the same operational conditions for 3 months. The use of urea resulted in less biomass content along the packed bed and better performance of the process, with a maximum elimination capacity (EC) of 57.6 g C m(-3 )h(-1) (removal efficiency (RE) of 88.3% and empty bed residence time (EBRT) of 60 s), which was around 54% higher than when using nitrate. EBRTs of 60, 30 and 15 s were evaluated with a urea-based nutrient supply. By decreasing the EBRT from 60 to 30 s the styrene concentration that could be treated with REs above 80% was almost the half, from 1,100 to 600 mg C m(-3), resulting in ECs of 52.8 g C m(-3) h(-1). Working at 15 s was not possible to obtain REs higher than 40% with a maximum EC of 28.5 g C m(-3) h(-1).


Subject(s)
Bioreactors , Filtration/methods , Nitrates/metabolism , Styrene/analysis , Urea/metabolism , Volatile Organic Compounds/analysis , Air Pollution , Biodegradation, Environmental , Biomass , Carbon Dioxide/metabolism , Gases/analysis , Gases/chemistry , Nitrates/analysis , Nitrates/chemistry , Nitrogen/chemistry , Styrene/chemistry , Urea/analysis , Urea/chemistry , Volatile Organic Compounds/chemistry
5.
J Air Waste Manag Assoc ; 59(8): 998-1006, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19728494

ABSTRACT

A 0.75-m3 pilot-scale biotrickling filter was run for over 1 yr in a Spanish furniture company to evaluate its performance in the removal of volatile organic compounds (VOCs) contained in the emission of two different paint spray booths. The first one was an open front booth used to manually paint furniture, and the second focus was an automatically operated closed booth operated to paint pieces of furniture. In both cases, the VOC emissions were very irregular, with rapid and extreme fluctuations. The pilot plant was operated at an empty bed residence time (EBRT) ranging from 10 to 40 sec, and good removal efficiencies of VOCs were usually obtained. When a buffering activated carbon prefilter was installed, the system performance was improved considerably, so a much better compliance with legal constraints was reached. After different shutdowns in the factory, the period to recover the previous performance of the biotrickling reactor was minimal. A weekend dehydration strategy was developed and implemented to control the pressure drop associated with excessive biomass accumulation.


Subject(s)
Air Pollution/prevention & control , Filtration/methods , Interior Design and Furnishings , Manufactured Materials , Volatile Organic Compounds/analysis , Biodegradation, Environmental , Bioreactors , Paint , Pilot Projects , Volatile Organic Compounds/metabolism
6.
Chemosphere ; 73(9): 1533-9, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18848344

ABSTRACT

Laboratory scale-studies on the biodegradation of a 1:1:1 weight mixture of three oxygenated volatile organic compounds (VOCs), ethanol, ethyl acetate, and methyl-ethyl ketone (MEK) in a biotrickling filter (BTF) were carried out using two identically sized columns, filled with different polypropylene rings. The performance of the BTFs was examined for a period of 10 months applying several operational strategies. Similar performance was obtained for both supports. Intermittent flow rate of trickling liquid was shown beneficial to improve the removal efficiency (RE). Continuous feeding of VOC resulted in an excessive accumulation of biomass so high pressure drop was developed in less than 20-30 d of operation. Intermittent VOC loading with night and weekend feed cut-off periods passing dry air, but without addition of water, was shown as a successful operational mode to control the thickness of the biofilm. In this case, operation at high inlet loads (ILs) was extended for more than 75 d maintaining high REs and low pressure drops. Outlet emission concentrations lower than 100 mg Cm(-3) were obtained for ILs up to 100 g Cm(-3)h(-1) working at 15s of empty bed residence time. The most easily biodegradable compounds ethanol and ethyl acetate were used primarily than MEK. After a 3-wk-starvation period, the system performance was almost restored since the first d of operation, being the removal of the less biodegradable compound, MEK, partially deteriorated.


Subject(s)
Air Pollutants/metabolism , Filtration/methods , Volatile Organic Compounds/metabolism , Water Pollutants, Chemical/metabolism , Acetates/analysis , Acetates/metabolism , Air Pollutants/analysis , Air Pollution/prevention & control , Biodegradation, Environmental , Butanones/analysis , Butanones/metabolism , Ethanol/analysis , Ethanol/metabolism , Filtration/instrumentation , Oxygen/chemistry , Volatile Organic Compounds/analysis , Water Pollutants, Chemical/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...