Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Reprod Biol Endocrinol ; 21(1): 45, 2023 May 16.
Article in English | MEDLINE | ID: mdl-37194068

ABSTRACT

PURPOSE: To explore the efficacy and safety of individualized follitropin delta dosing, based on serum anti-Müllerian hormone (AMH) concentration and bodyweight, in a long gonadotropin-releasing hormone (GnRH) agonist protocol. METHODS: Clinical outcomes after one treatment cycle are reported in women with AMH: 5-35 pmol/L. Oocytes were inseminated by intracytoplasmic sperm injection, blastocyst transfer was on Day 5 and remaining blastocysts were cryopreserved. Data collection included live births and neonatal health follow-up for all fresh/frozen transfers performed within one year after treatment allocation. RESULTS: In total, 104 women started stimulation, of whom 101 had oocyte recovery and 92 had blastocyst transfer. The average daily dose of follitropin delta was 11.0 ± 1.6 µg and the duration of stimulation was 10.3 ± 1.6 days. The mean number of oocytes was 12.5 ± 6.4, the mean number of blastocysts was 5.1 ± 3.4, and 85% had at least one good-quality blastocyst. Following mostly single blastocyst transfer (95%), the ongoing pregnancy rate was 43%, the live-birth rate was 43%, and the cumulative live-birth rate was 58% per started stimulation. There were 6 cases of early OHSS (5.8%) graded as mild (n = 3) and moderate (n = 3) and 6 cases of late OHSS (5.8%) graded as moderate (n = 3) and severe (n = 3). CONCLUSION: In this first evaluation of the individualized follitropin delta dosing in a long GnRH agonist protocol, the cumulative live-birth rate was high. A randomized trial comparing follitropin delta in a long GnRH agonist protocol versus in a GnRH antagonist protocol should provide further insight into the efficacy and safety of this treatment option. TRIAL REGISTRATION NUMBER: NCT03564509; June 21, 2018.


Subject(s)
Birth Rate , Ovarian Hyperstimulation Syndrome , Female , Humans , Male , Pregnancy , Fertilization in Vitro/methods , Gonadotropin-Releasing Hormone/agonists , Live Birth , Ovulation Induction/methods , Pregnancy Rate , Semen
2.
Reprod Biomed Online ; 43(2): 193-195, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34172391

ABSTRACT

RESEARCH QUESTION: During the embryo transfer procedure, to what degree of temperature drop are embryos exposed to between loading the transfer catheter and placing it into the uterus? DESIGN: Twenty-nine simulated embryo transfer procedures were carried out across five clinics. A thermocouple probe was used for standardized measurements inside the embryo transfer catheter to investigate the change in temperature that occurred in the time period between loading and placing the catheter in the uterus. RESULTS: In all cases, the temperature at the loaded catheter tip fell rapidly to ambient temperature during transit from the embryo transfer workstation in the laboratory to the procedure room, even though embryo transfer procedures, ambient temperatures and embryo transfer catheter temperatures at loading varied between clinics. CONCLUSIONS: Given the sensitivity of the pre-implantation embryo to its immediate environment, the rapid and profound drop in temperature observed at the catheter tip that houses the embryo during transit from laboratory to the uterus may affect embryo viability and health. This issue should be addressed to ensure that the tight temperature control aimed for by IVF laboratories continues throughout the embryo transfer procedure, and could improve clinical outcomes.


Subject(s)
Embryo Transfer/adverse effects , Embryo, Mammalian/physiology , Specimen Handling/adverse effects , Temperature , Adult , Cell Survival/physiology , Embryo Transfer/methods , Embryonic Development/physiology , Female , Humans , Infant, Newborn , Infertility/therapy , Male , Pilot Projects , Pregnancy , Pregnancy Rate , Specimen Handling/methods , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...