Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Air Waste Manag Assoc ; : 1-14, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38775962

ABSTRACT

The Wide Area Demonstration (WAD) was a field exercise conducted under the U.S. EPA's Analysis of Coastal Operational Resiliency program, in conjunction with the U.S. Department of Homeland Security and the U.S. Coast Guard. The purpose of the WAD was to operationalize at field scale aspects of remediation activities that would occur following an outdoor release of Bacillus anthracis spores, including sampling and analysis, decontamination, data management, and waste management. The WAD was conducted in May 2022 at Fort Walker (formerly known as Fort A.P. Hill) and utilized Bacillus atrophaeus as a benign simulant for B. anthracis. B. atrophaeus spores were inoculated onto the study area at the beginning of the study, and air samples were collected daily during each of the different phases of the WAD using Dry Filter Units (DFUs). Ten DFU air samplers were placed at the perimeter of the study area to collect bioaerosols onto two parallel 47-mm diameter polyester felt filters, which were then subsequently analyzed in a microbiological laboratory for the quantification of B. atrophaeus. The study demonstrated the use of DFUs as a rugged and robust bioaerosol collection device. The results indicated that the highest B. atrophaeus spore air concentrations (up to ~ 5 colony forming units/m3) occurred at the beginning of the demonstration (e.g. during inoculation and characterization sampling phases) and generally downwind from the test site, suggesting transport of the spores was occurring from the study area. Very few B. atrophaeus spores were detected in the air after several weeks and following decontamination of exterior surfaces, thus providing an indication of the site decontamination procedures' effectiveness. No B. atrophaeus spores were detected in any of the blank or background samples.Implications: Following an incident involving a release of Bacillus anthracis spores or other biological threat agent into the outdoor environment, understanding the factors that may affect the bioagent's fate and transport can help predict viable contaminant spread via the ambient air. This paper provides scientific data for the first time on ambient air concentrations of bacterial spores over time and location during different phases of a field test in which Bacillus atrophaeus (surrogate for B. anthracis) spores were released outdoors as part of a full-scale study on sampling and decontamination in an urban environment. This study advances the knowledge related to the fate and transport of bacterial spores (such as those causing anthrax disease) as an aerosol in the outdoor environment over the course of three weeks in a mock urban environment and has exposure and health risk implications. The highest spore air concentrations occurred at the beginning of the study (e.g. during inoculation of surfaces and characterization sampling), and in the downwind direction, but diminished over time; few B. atrophaeus spores were detected in the air after several weeks and following decontamination. Therefore, in an actual incident, potential reaerosolization of the microorganism and subsequent transport in the air during surface sampling and remediation efforts should be considered for determining exclusion zone locations and estimating potential risk to neighboring communities. The data also provide evidence suggesting that the large-scale decontamination of outdoor surfaces may reduce air concentrations of the bioagent, which is important since exposure of B. anthracis via inhalation is a primary concern.

2.
J Air Waste Manag Assoc ; 65(2): 145-53, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25947050

ABSTRACT

A wide-area Bacillus anthracis spore contamination incident will present immense challenges related to decontamination capacity. For this reason, fumigation with methyl bromide (MeBr) has been proposed as a potential remediation option. Although a few bench-scale laboratory studies have been conducted to evaluate activated carbon for the capture of MeBr, these studies were conducted at conditions replicating commodity fumigation using relatively low MeBr concentrations, temperatures, and/or relative humidity (RH) levels. The more rigorous MeBr fumigation requirements to fully inactivate B. anthracis spores are much more of a challenge for an activated carbon system (ACS) to capture MeBr, and warrant their own investigation. Further, while the aforementioned studies have shown activated carbon to be a possible option for the capture of MeBr in gas streams, these tests were conducted at laboratory bench scale, and thus lack operational perspective and data. Thus, we present for the first time the results of a full-scale study to evaluate an ACS employed for the capture of MeBr at conditions that would be used for decontaminating a building structure contaminated with B. anthracis spores. Airflow rate, temperature, RH, and MeBr levels were measured within the ACS during its operation. Despite the relatively high humidity, temperature, and MeBr levels, the MeBr capture efficiency of the ACS was demonstrated to be more than 99%. The concentration of MeBr exhausted from the structure was reduced from 41,000 to 136 ppmv in 3.5 hr, corresponding to an overall atmospheric emission rate of less than 2 kg. The practical adsorption rate of the ACS was determined to be 4.83 kg MeBr/100 kg carbon. The information and data presented here will facilitate future use of this technology when fumigating with MeBr.


Subject(s)
Air Pollutants/chemistry , Charcoal/chemistry , Decontamination/methods , Disinfectants/chemistry , Hydrocarbons, Brominated/chemistry , Adsorption , Bacillus anthracis/drug effects , Fumigation , Spores, Bacterial/drug effects
3.
J Air Waste Manag Assoc ; 60(8): 898-906, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20842929

ABSTRACT

Research and field experience with chlorine dioxide (ClO2) gas to decontaminate structures contaminated with Bacillus anthracis spores and other microorganisms have demonstrated the effectiveness of this sterilant technology. However, because of its hazardous properties, the unreacted ClO2, gas must be contained and captured during fumigation events. Although activated carbon has been used during some decontamination events to capture the ClO2 gas, no data are available to quantify the performance of the activated carbon in terms of adsorption capacity and other sorbent property operational features. Laboratory experiments were conducted to determine and compare the ClO2 adsorption capacities of five different types of activated carbon as a function of the challenge ClO2 concentration. Tests were also conducted to investigate other sorbent properties, including screening tests to determine gaseous species desorbed from the saturated sorbent upon warming (to provide an indication of how immobile the ClO2 gas and related compounds are once captured on the sorbent). In the adsorption tests, ClO2 gas was measured continuously using a photometric-based instrument, and these measurements were verified with a noncontinuous method utilizing wet chemistry analysis. The results show that the simple activated carbons (not impregnated or containing other activated sorbent materials) were the most effective, with maximum adsorption capacities of approximately 110 mg/g. In the desorption tests, there was minimal release of ClO(2) from all sorbents tested, but desorption levels of chlorine (Cl2) gas (detected as chloride) varied, with a maximum release of nearly 15% of the mass of ClO2 adsorbed.


Subject(s)
Carbon/chemistry , Chlorine Compounds/chemistry , Dental Disinfectants/chemistry , Oxides/chemistry , Adsorption , Temperature
4.
J Air Waste Manag Assoc ; 58(4): 484-93, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18422035

ABSTRACT

A bench-scale reactor consisting of a natural gas burner and an electrically heated reactor housing a selective catalytic reduction (SCR) catalyst was constructed for studying elemental mercury (Hg(o)) oxidation under SCR conditions. A low sulfur Powder River Basin (PRB) subbituminous coal combustion fly ash was injected into the entrained-flow reactor along with sulfur dioxide (SO2), nitrogen oxides (NOx), hydrogen chloride (HCl), and trace Hg(o). Concentrations of Hg(o) and total mercury (Hg) upstream and downstream of the SCR catalyst were measured using a Hg monitor. The effects of HCl concentration, SCR operating temperature, catalyst space velocity, and feed rate of PRB fly ash on Hg(o) oxidation were evaluated. It was observed that HCl provides the source of chlorine for Hg(o) oxidation under simulated PRB coal-fired SCR conditions. The decrease in Hg mass balance closure across the catalyst with decreasing HCl concentration suggests that transient Hg capture on the SCR catalyst occurred during the short test exposure periods and that the outlet speciation observed may not be representative of steady-state operation at longer exposure times. Increasing the space velocity and operating temperature of the SCR led to less Hg(o) oxidized. Introduction of PRB coal fly ash resulted in slightly decreased outlet oxidized mercury (Hg2+) as a percentage of total inlet Hg and correspondingly resulted in an incremental increase in Hg capture. The injection of ammonia (NH3) for NOx reduction by SCR was found to have a strong effect to decrease Hg oxidation. The observations suggest that Hg(o) oxidation may occur near the exit region of commercial SCR reactors. Passage of flue gas through SCR systems without NH3 injection, such as during the low-ozone season, may also impact Hg speciation and capture in the flue gas.


Subject(s)
Air Pollution/prevention & control , Coal , Mercury/chemistry , Rivers , Air Pollutants , Catalysis , Hydrochloric Acid , Nitrogen Compounds , Oxidation-Reduction , Power Plants , Sulfur , Sulfur Dioxide , Temperature
5.
Environ Sci Technol ; 36(20): 4454-9, 2002 Oct 15.
Article in English | MEDLINE | ID: mdl-12387423

ABSTRACT

Efforts to discern the role of an activated carbon's surface functional groups on the adsorption of elemental mercury (Hg0) and mercuric chloride demonstrated that chlorine (Cl) impregnation of a virgin activated carbon using dilute solutions of hydrogen chloride leads to increases (by a factor of 2-3) in fixed-bed capture of these mercury species. A commercially available activated carbon (DARCO FGD, NORITAmericas Inc. [FGD])was Cl-impregnated (Cl-FGD) [5 lb (2.3 kg) per batch] and tested for entrained-flow, short-time-scale capture of Hg0. In an entrained flow reactor, the Cl-FGD was introduced in Hg0-laden flue gases (86 ppb of Hg0) of varied compositions with gas/solid contact times of about 3-4 s, resulting in significant Hg0 removal (80-90%), compared to virgin FGD (10-15%). These levels of Hg0 removal were observed across a wide range of very low carbon-to-mercury weight ratios (1000-5000). Variation of the natural gas combustion flue gas composition, by doping with nitrogen oxides and sulfur dioxide, and the flow reactor temperature (100-200 degrees C) had minimal effects on Hg0 removal bythe Cl-FGD in these carbon-to-mercury weight ratios. These results demonstrate significant enhancement of activated carbon reactivity with minimal treatment and are applicable to combustion facilities equipped with downstream particulate matter removal such as an electrostatic precipitator.


Subject(s)
Carbon/chemistry , Mercuric Chloride/chemistry , Mercury/analysis , Refuse Disposal , Adsorption , Chemical Precipitation , Coal , Environmental Pollution/prevention & control , Incineration , Mercury/isolation & purification , Static Electricity
SELECTION OF CITATIONS
SEARCH DETAIL
...