Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
JAMA Neurol ; 80(12): 1277-1283, 2023 Dec 01.
Article in English | MEDLINE | ID: mdl-37902733

ABSTRACT

Importance: The STROKE AF study found that in patients with prior ischemic stroke attributed to large-artery atherosclerotic disease (LAD) or small-vessel occlusive disease (SVD), 12% developed AF over 1 year when monitored with an insertable cardiac monitor (ICM). The occurrence over subsequent years is unknown. Objectives: To compare the rates of AF detection through 3 years of follow-up between an ICM vs site-specific usual care in patients with prior ischemic stroke attributed to LAD or SVD. Design, Setting, and Participants: This multicenter, randomized (1:1) clinical trial took place at 33 sites in the US with enrollment between April 2016 and July 2019 and 3-year follow-up through July 2022. Eligible patients were aged 60 years or older, or aged 50 to 59 years with at least 1 additional stroke risk factor and had an index ischemic stroke attributed to LAD or SVD within 10 days prior to ICM insertion. Of the 496 patients enrolled, 492 were randomized and 4 were excluded. Interventions: ICM monitoring vs site-specific usual care. Main Outcomes and Measures: The prespecified long-term outcome of the trial was AF detection through study follow-up (up to 3 years). AF was defined as an episode lasting more than 30 seconds, adjudicated by an expert committee. Results: In total, 492 patients were randomized and included in the analyses (median [IQR] age, 66 [60-74] years; 307 men [62.4%] and 185 women [37.6%]), of whom 314 completed 3-year follow-up (63.8%). The incidence rate of AF at 3 years was 21.7% (46 patients) in the ICM group vs 2.4% (5 patients) in the control group (hazard ratio, 10.0; 95% CI, 4.0-25.2; P < .001). Conclusions and Relevance: Patients with ischemic stroke attributed to LAD or SVD face an increasing risk of AF over time and most of the AF occurrences are not reliably detected by standard medical monitoring methods. One year of negative monitoring should not reassure clinicians that patients who have experienced stroke will not develop AF over the next 2 years. Trial Registration: ClinicalTrials.gov Identifier: NCT02700945.


Subject(s)
Atrial Fibrillation , Ischemic Stroke , Stroke , Male , Humans , Female , Aged , Atrial Fibrillation/epidemiology , Stroke/epidemiology , Stroke/etiology , Stroke/physiopathology , Risk Factors , Ischemic Stroke/complications
2.
JAMA Neurol ; 80(1): 99-103, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36374508

ABSTRACT

Importance: The Stroke of Known Cause and Underlying Atrial Fibrillation (STROKE AF) trial found that approximately 1 in 8 patients with recent ischemic stroke attributed to large- or small-vessel disease had poststroke atrial fibrillation (AF) detected by an insertable cardiac monitor (ICM) at 12 months. Identifying predictors of AF could be useful when considering an ICM in routine poststroke clinical care. Objective: To determine the association between commonly assessed risk factors and poststroke detection of new AF in the STROKE AF cohort monitored by ICM. Design, Setting, and Participants: This was a prespecified analysis of a randomized (1:1) clinical trial that enrolled patients between April 1, 2016, and July 12, 2019, with primary follow-up through 2020 and mean (SD) duration of 11.0 (3.0) months. Eligible patients were selected from 33 clinical research sites in the US. Patients had an index stroke attributed to large- or small-vessel disease and were 60 years or older or aged 50 to 59 years with at least 1 additional stroke risk factor. A total of 496 patients were enrolled, and 492 were randomly assigned to study groups (3 did not meet inclusion criteria, and 1 withdrew consent). Patients in the ICM group had the index stroke within 10 days before insertion. Data were analyzed from October 8, 2021, to January 28, 2022. Interventions: ICM monitoring vs site-specific usual care (short-duration external cardiac monitoring). Main Outcomes and Measures: The ICM device automatically detects AF episodes 2 or more minutes in length; episodes were adjudicated by an expert committee. Cox regression multivariable modeling included all parameters identified in the univariate analysis having P values <.10. AF detection rates were calculated using Kaplan-Meier survival estimates. Results: The analysis included the 242 participants randomly assigned to the ICM group in the STROKE AF study. Among 242 patients monitored with ICM, 27 developed AF (mean [SD] age, 66.6 [9.3] years; 144 men [60.0%]; 96 [40.0%] women). Two patients had missing baseline data and exited the study early. Univariate predictors of AF detection included age (per 1-year increments: hazard ratio [HR], 1.05; 95% CI, 1.01-1.09; P = .02), CHA2DS2-VASc score (per point: HR, 1.54; 95% CI, 1.15-2.06; P = .004), chronic obstructive pulmonary disease (HR, 2.49; 95% CI, 0.86-7.20; P = .09), congestive heart failure (CHF; with preserved or reduced ejection fraction: HR, 6.64; 95% CI, 2.29-19.24; P < .001), left atrial enlargement (LAE; HR, 3.63; 95% CI, 1.55-8.47; P = .003), QRS duration (HR, 1.02; 95% CI, 1.00-1.04; P = .04), and kidney dysfunction (HR, 3.58; 95% CI, 1.35-9.46; P = .01). In multivariable modeling (n = 197), only CHF (HR, 5.06; 95% CI, 1.45-17.64; P = .05) and LAE (HR, 3.32; 1.34-8.19; P = .009) remained significant predictors of AF. At 12 months, patients with CHF and/or LAE (40 of 142 patients) had an AF detection rate of 23.4% vs 5.0% for patients with neither (HR, 5.1; 95% CI, 2.0-12.8; P < .001). Conclusions and Relevance: Among patients with ischemic stroke attributed to large- or small-vessel disease, CHF and LAE were associated with a significantly increased risk of poststroke AF detection. These patients may benefit most from the use of ICMs as part of a secondary stroke prevention strategy. However, the study was not powered for clinical predictors of AF, and therefore, other clinical characteristics may not have reached statistical significance. Trial Registration: ClinicalTrials.gov Identifier: NCT02700945.


Subject(s)
Atrial Fibrillation , Cardiomyopathies , Heart Failure , Ischemic Stroke , Stroke , Male , Humans , Female , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Stroke/complications , Risk Factors , Ischemic Stroke/complications
3.
JAMA ; 325(21): 2169-2177, 2021 06 01.
Article in English | MEDLINE | ID: mdl-34061145

ABSTRACT

Importance: Patients with ischemic stroke attributed to large- or small-vessel disease are not considered at high risk for atrial fibrillation (AF), and the AF incidence rate in this population is unknown. Objectives: To determine whether long-term cardiac monitoring is more effective than usual care for AF detection in patients with stroke attributed to large- or small-vessel disease through 12 months of follow-up. Design, Setting, and Participants: The STROKE-AF trial was a randomized (1:1), multicenter (33 sites in the US) clinical trial that enrolled 496 patients between April 2016 and July 2019, with primary end point follow-up through August 2020. Eligible patients were aged 60 years or older or aged 50 to 59 years with at least 1 additional stroke risk factor and had an index stroke attributed to large- or small-vessel disease within 10 days prior to insertable cardiac monitor (ICM) insertion. Interventions: Patients randomized to the intervention group (n = 242) received ICM insertion within 10 days of the index stroke; patients in the control group (n = 250) received site-specific usual care consisting of external cardiac monitoring, such as 12-lead electrocardiograms, Holter monitoring, telemetry, or event recorders. Main Outcomes and Measures: Incident AF lasting more than 30 seconds through 12 months. Results: Among 492 patients who were randomized (mean [SD] age, 67.1 [9.4] years; 185 [37.6%] women), 417 (84.8%) completed 12 months of follow-up. The median (interquartile range) CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke or transient ischemic attack, vascular disease, age 65 to 74 years, sex category) score was 5 (4-6). AF detection at 12 months was significantly higher in the ICM group vs the control group (27 patients [12.1%] vs 4 patients [1.8%]; hazard ratio, 7.4 [95% CI, 2.6-21.3]; P < .001). Among the 221 patients in the ICM group who received an ICM, 4 (1.8%) had ICM procedure-related adverse events (1 site infection, 2 incision site hemorrhages, and 1 implant site pain). Conclusions and Relevance: Among patients with stroke attributed to large- or small-vessel disease, monitoring with an ICM compared with usual care detected significantly more AF over 12 months. However, further research is needed to understand whether identifying AF in these patients is of clinical importance. Trial Registration: ClinicalTrials.gov Identifier: NCT02700945.


Subject(s)
Atrial Fibrillation/diagnosis , Electrocardiography, Ambulatory/methods , Intracranial Arterial Diseases/complications , Stroke/etiology , Aged , Atrial Fibrillation/complications , Electrocardiography , Electrocardiography, Ambulatory/adverse effects , Electrocardiography, Ambulatory/instrumentation , Electrodes, Implanted , Female , Humans , Ischemic Attack, Transient/etiology , Male , Middle Aged , Risk Factors , Stroke/prevention & control
4.
J Stroke Cerebrovasc Dis ; 29(9): 104934, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32807411

ABSTRACT

BACKGROUND AND PURPOSE: Use of implantable cardiac monitors (ICMs) has increased diagnosis of atrial fibrillation (AF) in cryptogenic stroke (CS) patients. Identifying AF predictors may enhance the yield of AF detection. Recurrent strokes after CS are not well described. We aimed to assess the predictors for AF detection and the characteristics of recurrent strokes in patients after CS. METHODS: We reviewed electronic medical records of CS patients who were admitted between February 2014 and September 2017 and underwent ICM placement with minimum one-year follow-up. Patient demographics, stroke characteristics, pre-defined risk factors as well as recurrent strokes were compared between patients with and without AF detection. RESULTS: 389 patients with median follow-up of 548 days were studied. AF was detected in 102 patients (26.2%). Age (per decade increase, OR 2.10, CI 1.64-2.68, with vs. without AF) and left atrium diameter (per 5 mm increase, OR 1.91, CI 1.33-2.74) were identified as AF predictors. Intracranial large vessel stenosis >50% irrelevant to the index strokes was associated with AF detection within 30 days (OR 0.24, CI 0.09-0.69, >30 vs. <30 days). Recurrent strokes occurred in 14% patients with median follow-up about 2.5 years. Topography of these strokes resembled embolic pattern and was comparable between patients with and without AF. Among recurrent strokes in patients with AF, the median time to AF detection was much shorter (90 vs. 251 days), and the median time to first stroke recurrence was much longer (422 vs. 76 days) in patients whose strokes recurred after AF detection than those before AF detection. CONCLUSIONS: Older age and enlarged left atrium are predictors for AF detection in CS patients. Intracranial atherosclerosis is more prevalent in patients with early AF detection within 30 days. Recurrent strokes follow the embolic pattern, and early AF detection could delay the stroke recurrence.


Subject(s)
Atrial Fibrillation/diagnosis , Embolism/diagnosis , Remote Sensing Technology/instrumentation , Stroke/diagnosis , Age Factors , Aged , Aged, 80 and over , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Delayed Diagnosis , Electronic Health Records , Embolism/epidemiology , Embolism/physiopathology , Female , Heart Rate , Humans , Male , Middle Aged , North Carolina/epidemiology , Predictive Value of Tests , Prevalence , Prognosis , Recurrence , Risk Assessment , Risk Factors , Stroke/epidemiology , Stroke/physiopathology , Time Factors
5.
Circulation ; 140(8): 658-664, 2019 08 20.
Article in English | MEDLINE | ID: mdl-31238700

ABSTRACT

BACKGROUND: In patients with acute minor ischemic stroke or high-risk transient ischemic attack enrolled in the POINT trial (Platelet-Oriented Inhibition in New TIA and Minor Ischemic Stroke [POINT] Trial), the combination of clopidogrel and aspirin for 90 days reduced major ischemic events but increased major hemorrhage in comparison to aspirin alone. METHODS: In a secondary analysis of POINT (N=4881), we assessed the time course for benefit and risk from the combination of clopidogrel and aspirin. The primary efficacy outcome was a composite of ischemic stroke, myocardial infarction, or ischemic vascular death. The primary safety outcome was major hemorrhage. Risks and benefits were estimated for delayed times of treatment initiation using left-truncated models. RESULTS: Through 90 days, the rate of major ischemic events was initially high then decreased markedly, whereas the rate of major hemorrhage remained low but relatively constant throughout. With the use of a model-based approach, the optimal change point for major ischemic events was 21 days (0-21 days hazard ratio 0.65 for clopidogrel-aspirin versus aspirin; 95% CI, 0.50-0.85; P=0.0015, in comparison to 22-90 days hazard ratio, 1.38; 95% CI, 0.81-2.35; P=0.24). Models showed benefits of clopidogrel-aspirin for treatment delayed as long as 3 days after symptom onset. CONCLUSIONS: The benefit of clopidogrel-aspirin occurs predominantly within the first 21 days, and outweighs the low, but ongoing risk of major hemorrhage. When considered with the results of the CHANCE trial (Clopidogrel in High-Risk Patients With Non-disabling Cerebrovascular Events), a similar trial treating with clopidogrel-aspirin for 21 days and showing no increase in major hemorrhage, these results suggest that limiting clopidogrel-aspirin use to 21 days may maximize benefit and reduce risk after high-risk transient ischemic attack or minor ischemic stroke. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT00991029.


Subject(s)
Aspirin/therapeutic use , Clopidogrel/therapeutic use , Drug Therapy, Combination/adverse effects , Drug-Related Side Effects and Adverse Reactions/prevention & control , Hemorrhage/prevention & control , Ischemia/drug therapy , Ischemic Attack, Transient/drug therapy , Platelet Aggregation Inhibitors/therapeutic use , Stroke/drug therapy , Time Factors , Acute Disease , Aspirin/adverse effects , Clinical Protocols , Clopidogrel/adverse effects , Hemorrhage/etiology , Humans , Platelet Aggregation Inhibitors/adverse effects , Proportional Hazards Models , Risk , Risk Assessment
7.
Neurorehabil Neural Repair ; 29(10): 911-22, 2015.
Article in English | MEDLINE | ID: mdl-25653225

ABSTRACT

BACKGROUND: Evidence supports peroneal nerve functional electrical stimulation (FES) as an effective alternative to ankle foot orthoses (AFO) for treatment of foot drop poststroke, but few long-term, randomized controlled comparisons exist. OBJECTIVE: Compare changes in gait quality and function between FES and AFOs in individuals with foot drop poststroke over a 12-month period. METHODS: Follow-up analysis of an unblinded randomized controlled trial (ClinicalTrials.gov #NCT01087957) conducted at 30 rehabilitation centers comparing FES to AFOs over 6 months. Subjects continued to wear their randomized device for another 6 months to final 12-month assessments. Subjects used study devices for all home and community ambulation. Multiply imputed intention-to-treat analyses were utilized; primary endpoints were tested for noninferiority and secondary endpoints for superiority. Primary endpoints: 10 Meter Walk Test (10MWT) and device-related serious adverse event rate. Secondary endpoints: 6-Minute Walk Test (6MWT), GaitRite Functional Ambulation Profile, and Modified Emory Functional Ambulation Profile (mEFAP). RESULTS: A total of 495 subjects were randomized, and 384 completed the 12-month follow-up. FES proved noninferior to AFOs for all primary endpoints. Both FES and AFO groups showed statistically and clinically significant improvement for 10MWT compared with initial measurement. No statistically significant between-group differences were found for primary or secondary endpoints. The FES group demonstrated statistically significant improvements for 6MWT and mEFAP Stair-time subscore. CONCLUSIONS: At 12 months, both FES and AFOs continue to demonstrate equivalent gains in gait speed. Results suggest that long-term FES use may lead to additional improvements in walking endurance and functional ambulation; further research is needed to confirm these findings.


Subject(s)
Electric Stimulation Therapy/methods , Gait Disorders, Neurologic/etiology , Gait Disorders, Neurologic/therapy , Peroneal Nerve/physiology , Stroke/complications , Aged , Ankle/physiopathology , Chronic Disease , Female , Foot Orthoses , Humans , Longitudinal Studies , Male , Middle Aged , Severity of Illness Index , Time Factors , Treatment Outcome , Walking/physiology
8.
Neurorehabil Neural Repair ; 28(7): 688-97, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24526708

ABSTRACT

BACKGROUND: Evidence supports peroneal nerve functional electrical stimulation (FES) as an effective alternative to ankle-foot orthoses (AFO) for treatment of foot drop poststroke, but few randomized controlled comparisons exist. OBJECTIVE: To compare changes in gait and quality of life (QoL) between FES and an AFO in individuals with foot drop poststroke. METHODS: In a multicenter randomized controlled trial (ClinicalTrials.gov #NCT01087957) with unblinded outcome assessments, 495 Medicare-eligible individuals at least 6 months poststroke wore FES or an AFO for 6 months. Primary endpoints: 10-Meter Walk Test (10MWT), a composite of the Mobility, Activities of Daily Living/Instrumental Activities of Daily Living, and Social Participation subscores on the Stroke Impact Scale (SIS), and device-related serious adverse event rate. Secondary endpoints: 6-Minute Walk Test, GaitRite Functional Ambulation Profile (FAP), Modified Emory Functional Ambulation Profile (mEFAP), Berg Balance Scale (BBS), Timed Up and Go, individual SIS domains, and Stroke-Specific Quality of Life measures. Multiply imputed intention-to-treat analyses were used with primary endpoints tested for noninferiority and secondary endpoints tested for superiority. RESULTS: A total of 399 subjects completed the study. FES proved noninferior to the AFO for all primary endpoints. Both the FES and AFO groups improved significantly on the 10MWT. Within the FES group, significant improvements were found for SIS composite score, total mFEAP score, individual Floor and Obstacle course time scores of the mEFAP, FAP, and BBS, but again, no between-group differences were found. CONCLUSIONS: Use of FES is equivalent to the AFO. Further studies should examine whether FES enables better performance in tasks involving functional mobility, activities of daily living, and balance.


Subject(s)
Electric Stimulation Therapy , Gait Disorders, Neurologic/rehabilitation , Peroneal Nerve/physiopathology , Stroke Rehabilitation , Aged , Ankle/innervation , Ankle/physiopathology , Chronic Disease , Female , Foot/innervation , Foot/physiopathology , Foot Orthoses , Gait Disorders, Neurologic/etiology , Gait Disorders, Neurologic/physiopathology , Humans , Male , Middle Aged , Quality of Life , Recovery of Function , Stroke/complications
9.
BMJ ; 328(7443): 789, 2004 Apr 03.
Article in English | MEDLINE | ID: mdl-15070626
SELECTION OF CITATIONS
SEARCH DETAIL
...