Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 13(1): 22082, 2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38086907

ABSTRACT

Lithium-ion batteries (LIBs) have become essential components that power most current technologies, such as smartphones and electric vehicles, thus making various safety evaluations necessary to ensure their safe use. Among these evaluations, heating tests remain the most prominent source of safety issues. However, information on the phenomena occurring inside batteries during heating has remained inaccessible. In this study, we demonstrate the first in situ neutron imaging method to observe the internal structural deformation of LIBs during heating. We developed an airtight aluminium chamber specially designed to prevent radioactive contamination during in situ neutron imaging. We successfully observed the liquid electrolyte fluctuation inside a battery sample and the deformation of the protective plastic film upon heating up to thermal runaway. Hence, this work provides the foundation for future investigations of the internal changes induced in batteries during heating tests and experiments.

2.
J Synchrotron Radiat ; 29(Pt 5): 1258-1264, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36073885

ABSTRACT

An X-ray computed nano-tomography (nano-CT) system has been established at the BL33XU beamline of SPring-8. The optical system consists of pseudo-Köhler illumination with a sector condenser zone plate, an apodization Fresnel zone plate as the objective lens, and a Zernike phase plate. The imaging detector is a fiber-coupling type X-ray camera. The performance of the X-ray nano-CT system was confirmed by imaging an X-ray test chart. The system was subsequently applied to the observation of a microporous layer for polymer electrolyte fuel cells and a simulated microporous layer including liquid water. The nano-CT system, which can perform a computed tomography measurement in less than 4 min, allowed visualization of a spherical water droplet produced in the microporous layer. In the present study, the shape of water droplets in a nanoscale porous structure is investigated.

3.
J Imaging ; 7(11)2021 Nov 02.
Article in English | MEDLINE | ID: mdl-34821863

ABSTRACT

Neutron radiography is regarded as complementary to X-ray radiography in terms of transmittance through materials, but its spatial resolution is still insufficient. In order to achieve higher resolution in neutron imaging, several approaches have been adopted, such as optical magnification and event centroiding. In this paper, the authors focused on modification of the scintillator. A Gd3Al2Ga3O12:Ce single-crystal scintillator was applied to neutron radiography for the first time and a spatial resolution of 10.5 µm was achieved. The results indicate that this material can be a powerful candidate for a new neutron scintillator providing a resolution in micrometer order by optimizing the optical system and increasing the scintillator luminosity.

4.
Phys Chem Chem Phys ; 23(2): 1062-1071, 2021 Jan 21.
Article in English | MEDLINE | ID: mdl-33346285

ABSTRACT

This study is the first report on liquid water and ice imaging conducted at a pulsed spallation neutron source facility. Neutron imaging can be utilised to visualise the water distribution inside polymer electrolyte fuel cells (PEFCs). Particularly, energy-resolved neutron imaging is a methodology capable of distinguishing between liquid water and ice, and is effective for investigating ice formation in PEFCs operating in a subfreezing environment. The distinction principle is based on the fact that the cross sections of liquid water and ice differ from each other at low neutron energies. In order to quantitatively observe transient freezing and thawing phenomena in a multiphase mixture (gas/liquid/solid) within real PEFCs with high spatial resolution, a pulsed neutron beam with both high intensity and wide energy range is most appropriate. In the validation study of the present work, we used water sealed in narrow capillary tubes to simulate the flow channels of a PEFC, and a pulsed neutron beam was applied to distinguish ice, liquid water and super-cooled water, and to clarify freezing and thawing phenomena of the water within the capillary tubes. Moreover, we have enabled the observation of liquid water/ice distributions in a large field of view (300 mm × 300 mm) by manufacturing a sub-zero environment chamber that can be cooled down to -30 °C, as a step towards in situ visualisation of full-size fuel cells.

5.
Science ; 366(6472): 1492-1496, 2019 Dec 20.
Article in English | MEDLINE | ID: mdl-31857480

ABSTRACT

The failure of polycrystalline materials used in infrastructure and transportation can be catastrophic. Multiscale modeling, which requires multiscale measurements of internal stress fields, is the key to predicting the deformation and failure of alloys. We determined the three-dimensional intragranular stress tensor fields in plastically deformed bulk steel using a high-energy x-ray microbeam. We observed intragranular local stresses that deviated greatly from the grain-averaged stresses and exceeded the macroscopic tensile strength. Even under deformation smaller than the uniform elongation, the intragranular stress fields were in highly triaxial stress states, which cannot be determined from the grain-averaged stresses. The ability to determine intragranular stress tensor fields can facilitate the understanding and prediction of the deformation and failure of materials through multiscale modeling.

SELECTION OF CITATIONS
SEARCH DETAIL
...