Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Synchrotron Radiat ; 27(Pt 3): 590-598, 2020 May 01.
Article in English | MEDLINE | ID: mdl-32381758

ABSTRACT

The Advanced Photon Source 1-ID beamline, operating in the 40-140 keV X-ray energy range, has successfully employed continuously tunable saw-tooth refractive lenses to routinely deliver beams focused in both one and two dimensions to experiments for over 15 years. The practical experience of implementing such lenses, made of silicon and aluminium, is presented, including their properties, control, alignment, and diagnostic methods, achieving ∼1 µm focusing (vertically). Ongoing development and prospects towards submicrometre focusing at these high energies are also mentioned.

2.
Struct Dyn ; 6(1): 014501, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30868086

ABSTRACT

Long-standing evidence suggests that plasticity in metals may proceed in an intermittent fashion. While the documentation of intermittency in plastically deforming materials has been achieved in several experimental settings, efforts to draw connections from dislocation motion and structure development to stress relaxation have been limited, especially in the bulk of deforming polycrystals. This work uses high energy x-ray diffraction measurements to build these links by characterizing plastic deformation events inside individual deforming grains in both the titanium alloy, Ti-7Al, and the magnesium alloy, AZ31. This analysis is performed by combining macroscopic stress relaxation data, complete grain stress states found using far-field high energy diffraction microscopy, and rapid x-ray diffraction spot measurements made using a Mixed-Mode Pixel Array Detector. Changes in the dislocation content within the deforming grains are monitored using the evolution of the full 3-D shapes of the diffraction spot intensity distributions in reciprocal space. The results for the Ti-7Al alloy show the presence of large stress fluctuations in contrast to AZ31, which shows a lesser degree of intermittent plastic flow.

3.
J Microsc ; 255(2): 71-7, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25131662

ABSTRACT

The prior ß grain structure and orientations in the central stir zone of friction stir-processed Ti-6Al-4V were reconstructed from measured α phase orientations obtained by three-dimensional serial sectioning in a dual-beam focused ion beam scanning electron microscope. The data were processed to obtain the α colony and ß grain size distributions in the volume. Several ß grains were individually analysed to determine the total number of unique α variants and the respective volume fractions of each. The analysis revealed that some grains experienced overwhelming variant selection (i.e. one variant dominated) whereas other ß grains contained a more evenly distributed mixture of all 12 variants.

4.
J Microsc ; 248(2): 172-86, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23078117

ABSTRACT

A method for automatically aligning consecutive data sets of large, two-dimensional multi-tile electron backscatter diffraction (EBSD) scans with high accuracy was developed. The method involved first locating grain and phase boundaries within search regions containing overlapping data in adjacent scan tiles, and subsequently using cross-correlation algorithms to determine the relative position of the individual scan tiles which maximizes the fraction of overlapping boundaries. Savitzky-Golay filtering in two dimensions was used to estimate the background, which was then subtracted from the cross-correlation to enhance the peak signal in samples with a high density of interfaces. The technique was demonstrated on data sets with a range of interface densities. The equations were implemented as enhancements to a recently published open source code for stitching of multi-tile EBSD data sets.

5.
J Microsc ; 244(2): 181-6, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21810094

ABSTRACT

Recent software and hardware advances in the field of electron backscatter diffraction have led to an increase in the rate of data acquisition. Combining automated stage movements with conventional beam control have allowed researchers to collect data from significantly larger areas of samples than was previously possible. This paper describes a LabVIEW™ and AutoIT(©) code which allows for increased flexibility compared to commercially available software. The source code for this software has been made available in the online version of this paper.

SELECTION OF CITATIONS
SEARCH DETAIL