Article in English | MEDLINE | ID: mdl-38443707

ABSTRACT

INTRODUCTION: Cardiac implantable electronic device (CIED) functions are susceptible to electromagnetic interference (EMI) from electromagnetic fields (EMF). Data on EMI risks from new-generation electronic appliances (EA) are limited. OBJECTIVE: We performed a systematic literature review on the mechanisms of EMI, current evidence, and recently published trials evaluating the effect of EMF on CIEDs from electric vehicles (EV), smartphone, and smartwatch technology and summarize its safety data. METHODS: Electronic databases, including PubMed and EMBASE, were searched for in vivo studies evaluating EMF strength and incidence between CIEDs and commercial EVs, new-generation smartphones, and new-generation smartwatches. RESULTS: A total of ten studies (three on EVs, five on smartphones, one on smartphones, one on smartphones and smartwatches) were included in our systematic review. There was no report of EMI incidence associated with EVs or smartwatches. Magnet-containing smartphones (iPhone 12) can cause EMI when placed directly over CIEDs - thereby triggering the magnet mode; otherwise, no report of EMI was observed with other positions or smartphone models. CONCLUSION: Current evidence suggests CIED recipients are safe from general interaction with EVs/HEVs, smartphones, and smartwatches. Strictly, results may only be applied to commercial brands or models tested in the published studies. There is limited data on EMI risk from EVs wireless charging and smartphones with MagSafe technology.

6.
J Cardiovasc Electrophysiol ; 34(11): 2382-2385, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37679961

ABSTRACT

BACKGROUND: Dual occlusive closure mechanism (disc and lobe type), Amulet device (Abbott; a second-generation device that has replaced Amplatzer Cardiac Plug) was approved by the Food and Drug Administration (FDA) in August 2021 for percutaneous left atrial appendage occlusion (LAAO). However, real-world safety data on the delivery system (Amplatzer Cardiac Plug and Amplatzer Amulet device) are lacking. OBJECTIVE: We sought to assess the type of adverse events associated with the Amplatzer LAAO delivery system using the FDA Manufacturer and User Facility Device Experience (MAUDE) database. METHODS: A MAUDE database search was conducted on March 31, 2023, for reports received between February 2013 and March 2023 to capture all adverse events. RESULTS: A total of 59 adverse events were reported, of which 58 were sheath-related events, and one was a wire-related event. The most commonly encountered issue was air embolism (19%, 11 events), followed by sheath thrombosis (13.8%, eight events, two of which were also associated with device thrombosis), kinked sheath (10.3%, six events), and sheath deformation (8.6%, five events). Patient-related adverse events included pericardial effusion requiring pericardiocentesis (22.4%, 13 events), vascular complications (20.7%, 12 events), and device dislodgement (5.2%, three events). CONCLUSION: LAAO-related adverse events are increasingly being reported using the Amplatzer LAAO delivery sheath. It is anticipated that improvements in device technology, the advent of steerable sheaths, and operator experience will minimize these complications.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Septal Occluder Device , Stroke , Thrombosis , United States , Humans , Atrial Appendage/diagnostic imaging , United States Food and Drug Administration , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/complications , Cardiac Catheterization/adverse effects , Thrombosis/etiology , Treatment Outcome , Stroke/etiology , Stroke/prevention & control , Septal Occluder Device/adverse effects
7.
Am J Cardiol ; 205: 1-9, 2023 10 15.
Article in English | MEDLINE | ID: mdl-37573632

ABSTRACT

Transcatheter aortic valve replacement (TAVR) carries a risk of high-grade AV block requiring cardiac implantable electronic device (CIED) implantation, which has been associated with a higher mortality rate. However, the outcomes of TAVR in patients with preexisting CIEDs are not well understood. We conducted a retrospective analysis of consecutive patients who underwent TAVR from December 2014 to December 2019 at our institution. Patients were categorized into 3 groups: preexisting CIED pre-TAVR (group 1), CIED implanted within 30 days after TAVR (group 2), and no CIED implanted (group 3). Cox proportional hazard was conducted to determine the primary end point of all-cause mortality. A total of 366 patients were included, of whom 93 (25.4%), 51 (13.9%), and 222 (60.7%) comprised group 1, 2, and 3, respectively. The median follow-up time was 2.3 years. The all-cause mortality rate was higher in group 1 than group 2 (hazard ratio [HR] 2.60, 95% confidence interval [CI] 1.09 to 6.18, p = 0.03) and group 3 (HR 1.96, 95% CI 1.24 to 3.08, p = 0.004). On the multivariate analysis, there was no statistically significant difference in mortality among the groups (group 1 vs group 2: HR 1.95, 95% CI 0.70 to 5.44, p = 0.20 and group 1 vs group 3: HR 1.27, 95% CI 0.66 to 2.43, p = 0.47). Preoperative hemoglobin ≤12 g/100 ml was an independent predictor of all-cause mortality (HR 1.75, 95% CI 1.10 to 2.80, p = 0.02). Group 1 had a higher 1 year congestive heart failure readmission rate (29%) than group 2 (17.6%) and group 3 (8.1%; p <0.0001). In conclusion, there was no difference in the adjusted long-term survival based on the CIED grouping. However, patients with preexisting CIEDs had higher all-cause mortality and 1-year congestive heart failure readmission rates owing to their higher co-morbidity burden, irrespective of their Society of Thoracic Surgeons score. This can be taken into account for preoperative risk stratification.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/complications , Retrospective Studies , Treatment Outcome , Risk Factors , Heart Failure/complications , Aortic Valve/surgery
9.
J Cardiovasc Electrophysiol ; 34(6): 1469-1471, 2023 06.
Article in English | MEDLINE | ID: mdl-37209414

ABSTRACT

BACKGROUND: Leadless pacemaker (LP) offers an innovative approach for treating bradyarrhythmia, thus avoiding pacemaker pocket and lead-related complications. The Food and Drug Administration (FDA) has recently approved the Aveir™ leadless pacing system (screw-in type LP). METHODS: We queried the FDA MAUDE database to study the safety profile and assess the types of complications with this relatively novel device technology. A MAUDE database search was conducted on January 20, 2023, for reports received post-FDA approval to capture all adverse events. RESULTS: A total of 98 medical device report were reported for Aveir™ LP. After excluding duplicate, programmer-related, or introducer-sheath-related entries (n = 34), 64 entries were included. The most commonly encountered problem was high threshold/noncapture (28.1%, 18 events), followed by stretched helix (17.2%, 11 events) and device dislodgement (15.6%, ten events-5 intraprocedural, while 5 in the postoperative Day 1). Other reported events included high impedance (14.1%, nine events), sensing issues (12.5%, eight events), bent/broken helix (7.8%, five events), premature separation (4.7%, three events), interrogation problem (3.1%, two events), low impedance (3.1%, two events), premature battery depletion (1.6%, one event) and inadvertent MRI mode switch (1.6%, one event) and miscellaneous (15.6%, n = 10). There were eight serious patient injury events-pericardial effusion requiring pericardiocentesis (7.8%, five events) due to cardiac perforation that resulted in two deaths (3.1%) followed by sustained ventricular arrhythmias (4.6%, n = 3). CONCLUSION: In our study assessing the real-world safety profile of the Aveir™ LP, serious adverse events have been reported-life-threatening ventricular arrhythmias, pericardial effusion, device explantation/reimplantation, and death.


Subject(s)
Pacemaker, Artificial , Pericardial Effusion , Virtual Reality , United States , Humans , United States Food and Drug Administration , Pericardial Effusion/etiology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Pacemaker, Artificial/adverse effects
11.
J Interv Card Electrophysiol ; 66(3): 561-566, 2023 Apr.
Article in English | MEDLINE | ID: mdl-35469052

ABSTRACT

BACKGROUND: There has been increasing interest in physiologic pacing techniques that directly activate the specialized conduction system. We aimed to assess outcomes of conduction system pacing (CSP) in patients with prosthetic heart valves. METHODS: This systematic review was performed according to PRISMA guidelines. Freeman-Tukey double arcsine transformation with the random-effect model was used to summarize the data. Outcomes studied were 1) implant success (defined as ability to recruit the His-Purkinje system or the distal Purkinje system); (2) lead parameters at implant and follow-up; and (3) procedure-related complications. RESULTS: This systematic review of 7 studies included 267 unique patients in whom CSP was attempted with either HBP or LBBAP for pacing indications after a prosthetic valve. HBP was attempted in 38% (n = 108), while LBBAP in 62% (n = 175) patients. The overall success rate of CSP was 87%, while in patients post-TAVR, the overall success rate was 83.2%. In the subgroup analysis, LBBAP had a significant higher overall success rate compared to HBP (94.3% vs. 76.5%, p interaction = 0.02) and post-TAVR patients (94.3 vs. 66.9%, p interaction < 0.01), respectively. The LBBAP thresholds were significantly lower compared to HBP both at implant (0.67 ± 0.4 @ 0.44 ms vs. 1.35 ± 1 @ 0.85 ms, p interaction < 0.01) and at a mean follow-up of 12.4 ± 8 months (0.73 ± 0.1 @ 0.44 ms vs. 1.39 ± 1 @ 0.85 ms, p interaction < 0.01), respectively. CONCLUSION: CSP is safe and feasible in patients with a prosthetic valve, with a significantly higher success rate and superior lead parameters with LBBAP than HBP, especially in patients post-TAVR.


Subject(s)
Bundle of His , Cardiac Pacing, Artificial , Humans , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Heart Conduction System , Cardiac Conduction System Disease , Heart Valves , Treatment Outcome
12.
J Cardiovasc Electrophysiol ; 34(1): 219-224, 2023 01.
Article in English | MEDLINE | ID: mdl-36335616

ABSTRACT

BACKGROUND: Monomorphic ventricular tachycardia (VT) is rare in patients with hypertrophic cardiomyopathy (HCM), management of which is challenging. Limited data exists on the utility of catheter ablation for the treatment of VT in this population. OBJECTIVES: We aimed to assess clinical outcomes of catheter ablation for VT in HCM patients. METHODS: A systematic search, without language restriction, using PubMed, EMBASE, SCOPUS, Google Scholar, and ClinicalTrials.gov was performed. The meta-analysis was performed using a meta-package for R version 4.0/RStudio version 1.2 and Freeman Tukey double arcsine method to establish the variance of raw proportions. Outcomes measured included (1) acute procedure success (defined as noninducible for clinical VT), (2) freedom from VT at follow-up, (3) mortality. RESULTS: This systematic review of six studies (three from the United States and three from Japan) incorporated a total of 68 drug-refractory HCM patients who underwent VT radiofrequency catheter ablation (mean age 57.6 ± 13.3 years, mean LVEF 45.8 ± 15.4%, 85% men, maximum septal wall thickness 17.4 ± 4.6 mm, and 32.3% with an apical aneurysm). Acute procedural success was achieved in 84.5% patients (95% confidence interval [CI]: 70.6%-95.2%) with 27.9% patients had recurrent VT requiring multiple ablations (median 1, IQR 1-3). During the follow-up period (18.3 ± 11.7 months), the pooled incidence of freedom from recurrent VT after index procedure was 70.2% (95% CI: 51.9%-86.2%), while after the last ablation was 82.8% (95% CI: 57%-99.2%). There were two deaths during follow-up, one from heart failure and one from SCD 0.8% (95% CI: 0%-5.8%). CONCLUSION: The results of our pooled analysis demonstrated that catheter ablation for VT in HCM patients was associated with high acute procedural success, and reduced VT recurrence-findings comparable to previously published reports in other disease substrates.


Subject(s)
Cardiomyopathy, Hypertrophic , Catheter Ablation , Heart Failure , Tachycardia, Ventricular , Male , Humans , Adult , Middle Aged , Aged , Female , Recurrence , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/etiology , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/diagnostic imaging , Catheter Ablation/methods , Heart Failure/etiology , Treatment Outcome
14.
J Innov Card Rhythm Manag ; 13(5): 5004-5008, 2022 May.
Article in English | MEDLINE | ID: mdl-35655806

ABSTRACT

Ventricular lead perforation is an infrequent and potentially fatal complication of pacemakers and implantable cardioverter-defibrillators that typically presents shortly following device implantation. Delayed lead perforations occurring 1 month after implantation are not widely reported and can have a wide range of presentations ranging from asymptomatic to potentially fatal cardiac tamponade. We describe a case of successful percutaneous lead extraction and revision in a patient who presented 9 months following implantation with an active fixation right ventricular pacing lead with apical perforation. Perforation was suspected when device interrogation showed ventricular sensing without ventricular capture, but with diaphragm stimulation. After an initial X-ray and transthoracic echocardiogram failed to detect it, computed tomography angiography confirmed the myocardial perforation. This case demonstrates the importance of recognizing such a complication following cardiac implantable electronic device implantation regardless of the timeline of presentation. It also serves to highlight the importance of clinical suspicion and awareness of the limitations of imaging for perforation. Transvenous percutaneous lead extraction and revision remains a favored approach due to reduced patient trauma when compared to the open surgical approach.

17.
Pacing Clin Electrophysiol ; 45(4): 567-570, 2022 04.
Article in English | MEDLINE | ID: mdl-35199863

ABSTRACT

BACKGROUND: Thromboembolic (TE) events are among the most common and devastating adverse events in patients with continuous-flow left ventricular assist device (cf-LVAD). Given the high burden of AF among cf-LVAD patients, we sought to evaluate the effect of concomitant surgical LAAO in patients receiving cf-LVAD. METHODS: A systematic search using electronic databases was performed using the keywords: "left atrial appendage occlusion" and "left ventricular assist device." Statistical analysis was performed using metapackage for R version 4.0 and Rstudio version 1.2. Mantel-Haenszel risk ratio (RR) random-effects model was used to summarize data between two groups. The primary outcomes included: (a) stroke; (b) LVAD pump thrombosis; (c) all-cause mortality RESULTS: Three studies with a total of 305 patients (LAAO = 68 and No-LAAO = 237) were included in the analysis. HeartMate II (39%) and Heartware (27.5%) were the two most common cf-LVADs utilized, while only 5% received HeartMate III. At a mean follow up of 1.47 years, LAAO group had a lower risk of stroke (8.8% vs. 15.2%, RR 0.64; 95% CI 0.28-1.49), LVAD pump thrombosis (1.5% vs. 3.8%, RR 0.28; 95% CI 0.05-1.55) and all-cause mortality (5.9% vs. 20.2%, RR 0.69; 95% CI 0.19-2.52) when compared with no-LAAO group, but the difference did not reach statistical significance. CONCLUSION: Concomitant surgical LAAO at the time of cf-LVAD implantation demonstrated a trend toward positive outcomes and was not associated with adverse outcomes during the follow-up period, though the results were not statistically significant.


Subject(s)
Atrial Appendage , Heart Failure , Heart-Assist Devices , Stroke , Thromboembolism , Thrombosis , Atrial Appendage/surgery , Heart Failure/complications , Heart-Assist Devices/adverse effects , Humans , Retrospective Studies , Stroke/complications , Thromboembolism/etiology , Thrombosis/etiology , Treatment Outcome
20.
Rev Cardiovasc Med ; 23(1): 34, 2022 Jan 19.
Article in English | MEDLINE | ID: mdl-35092226

ABSTRACT

BACKGROUND: Perioperative anticoagulation management with uninterrupted or minimally interrupted anticoagulation during atrial fibrillation (AF) ablation is thought to be critical to minimize thromboembolic complications. Protamine is often administered to neutralize the effects of heparin and expedite vascular hemostasis post-procedure. OBJECTIVE: We performed a systematic review and meta-analysis to determine the effectiveness of protamine to expedite vascular hemostasis and ambulation in patients undergoing AF ablation. METHODS: Electronic searches on PubMed, The Cochrane Library, EMBASE, EBSCO, Web of Science, and CINAHL databases from the inception through August 7, 2021, were performed. The primary outcomes included-time to hemostasis (minutes) and time to ambulation (minutes). The secondary outcomes included - any vascular complications (excluding minor hematoma), minor hematoma, or cerebrovascular accidents (CVA). RESULTS: A total of 5 eligible studies (3 retrospective cohort studies and two randomized trials) consisting of 1012 patients (515 patients received protamine group and 497 patients did not receive protamine group) were included in the meta-analysis. There was a significant reduction in time to ambulation [weighted mean difference (WMD) -176.6 minutes, 95% Confidence interval (CI) -266.9 to -86.3; p < 0.01] and time to hemostasis (WMD -13.72 minutes, 95% CI -22 to -5.4, p < 0.01) in the protamine group compared to the contrary. At a follow-up up to 3 months, there was no statistical difference between the two groups with regards to vascular complications (2.9% vs. 7.4%; Risk ratio (RR) 0.46 95% CI 0.17 to 1.24; p = 0.12), minor hematoma (2.1% vs. 5.8%; RR 0.43, 95% CI 0.16 to 1.2; p = 0.11) or CVA (0 vs. 0.3%; RR 0.62, 95% CI 0.08 to 4.98; p = 0.65). CONCLUSION: Protamine administration was associated with reduced time to ambulation (176 minutes reduction) and time to hemostasis (13 minutes reduction) without an increase in any adverse events.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Anticoagulants/adverse effects , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Humans , Protamines/adverse effects , Retrospective Studies , Treatment Outcome