1.
J Glob Health ; 14: 04086, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38751318

ABSTRACT

Background: It is imperative to maintain accurate documentation of clinical interventions aimed at enhancing the quality of care for newborns and sick children. The National Newborn Health and IMCI programme of Bangladesh led the development of a standardised register for managing newborns and sick children under five years of age during inpatient care through stakeholder engagement. We aimed to assess the implementation outcomes of the standardised register in the inpatient department. Methods: We conducted implementation research in two district hospitals and two sub-district hospitals of Kushtia and Dinajpur districts from November 2022 to January 2023 to assess the implementation outcomes of the standardised register. We assessed the following World Health Organization implementation outcome variables: usability, acceptability, adoption (actual use), fidelity (completeness and accuracy), and utility (quality of care) of the register against preset benchmarks. We collected data through structured interviews with health care providers; participant enrolment; and data extraction from inpatient registers and case record forms. Results: The average usability and acceptability scores among health care providers were 73 (standard deviation (SD) = 14) and 82 (SD = 14) out of 100, respectively. The inpatient register recorded 96% (95% confidence interval (CI) = 95-97) of under-five children who were admitted to the inpatient department (adoption - actual use). The proportions of completed data elements in the inpatient register were above the preset benchmark of 70% for all the assessed data elements except 'investigation done' (24%; 95% CI = 23-26) (fidelity - completeness). The percentage agreements between government-appointed nurses posted and study-appointed nurses were above the preset benchmark of 70% for all the reported variables (fidelity - accuracy). The kappa coefficient for the overall level of agreement between these two groups regarding reported variables indicated moderate to substantial agreement. The proportion of newborns with sepsis receiving injectable antibiotics was 62% (95% CI = 47-75) (utility - quality of care). We observed some variability in the completeness and accuracy of the inpatient register by district and facility type. Conclusions: The inpatient register was positively received by health care providers, with evaluations of implementation outcome variables showing encouraging results. Our findings could inform evidence-based decision-making on the implementation and scale-up of the inpatient register in Bangladesh, as well as other low- and middle-income countries.


Subject(s)
Registries , Humans , Bangladesh , Infant, Newborn , Infant , Child, Preschool , Health Facilities/standards , Hospitalization/statistics & numerical data , Inpatients/statistics & numerical data , Quality of Health Care
2.
EClinicalMedicine ; 50: 101511, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35795715

ABSTRACT

Background: Pulse oximetry has potential for identifying hypoxaemic pneumonia and substantially reducing under-five deaths in low- and middle-income countries (LMICs) setting. However, there are few examples of introducing pulse oximetry in resource-constrained paediatric outpatient settings, such as Integrated Management of Childhood Illness (IMCI) services. Methods: The National IMCI-programme of Bangladesh designed and developed a district implementation model for introducing pulse oximetry in routine IMCI services through stakeholder engagement and demonstrated the model in Kushtia district adopting a health system strengthening approach. Between December 2020 and June 2021, two rounds of assessment were conducted based on WHO's implementation research framework and outcome variables, involving 22 IMCI service-providers and 1680 children presenting with cough/difficulty-in-breathing in 12 health facilities. The data collection procedures included structured-observations, re-assessments, interviews, and data-extraction by trained study personnel. Findings: We observed that IMCI service-providers conducted pulse oximetry assessments on all eligible children in routine outpatient settings, of which 99% of assessments were successful; 85% (95% CI 83,87) in one attempt, and 69% (95% CI 67,71) within one minute. The adherence to standard operating procedure related to pulse oximetry was 92% (95% CI 91,93), and agreement regarding identifying hypoxaemia was 97% (95% CI 96,98). The median performance-time was 36 seconds (IQR 20,75), which was longer among younger children (2-11 months: 44s, IQR 22,78; 12-59 months: 30s, IQR 18,53, p < 0.01) and among those classified as pneumonia/severe-pneumonia than as no-pneumonia (41s, IQR 22,70; 32s, IQR 20,62, p < 0.01). We observed improvements in almost all indicators in round-2. IMCI service-providers and caregivers showed positive attitudes towards using this novel technology for assessing their children. Interpretation: This implementation research study suggested the adoption, feasibility, fidelity, appropriateness, acceptability, and sustainability of pulse oximetry introduction in routine IMCI services in resource-poor settings. The learning may inform the evidence-based scale-up of pulse oximetry linked with an oxygen delivery system in Bangladesh and other LMICs. Funding: This research was funded by the UK National Institute for Health Research (NIHR) (Global Health Research Unit on Respiratory Health (RESPIRE); 16/136/109) using UK aid from the UK Government to support global health research.

3.
J Glob Health ; 12: 04036, 2022.
Article in English | MEDLINE | ID: mdl-35493782

ABSTRACT

Background: Hypoxaemia is one of the strongest predictors of mortality among children with pneumonia. It can be identified through pulse oximetry instantaneously, which is a non-invasive procedure but can be influenced by factors related to the specific measuring device, health provider and patient. Following WHO's global recommendation in 2014, Bangladesh decided to introduce pulse oximetry in paediatric outpatient services, ie, the Integrated Management of Childhood Illness (IMCI) services in 2019. A national committee updated the existing IMCI implementation package and decided to test it by assessing the pulse oximetry performance of different types of assessors in real-life inpatient settings. Methods: We adopted an observational design and conducted a technology assessment among children admitted to a rural district hospital. Eleven nurses and seven paramedics received one-day training on pulse oximetry as assessors. Each assessor performed at least 30 pulse oximetry measurements on children with two types of handheld devices. The primary outcome of interest was obtaining a successful measurement of SpO2, defined as observing a stable (±1%) reading for at least 10 seconds. Performance time, ie, time taken to obtain a successful measurement of SpO2 was considered the secondary outcome of interest. In addition, we used Generalized Estimating Equation to assess the effect of different factors on the pulse oximetry performance. Results: The assessors obtained successful measurements of SpO2 in all attempts (n = 1478) except one. The median time taken was 30 (interquartile range (IQR) = 22-42) seconds, and within 60 seconds, 92% of attempts were successful. The odds of obtaining a successful measurement within 60 seconds were 7.3 (95% confidence interval (CI) = 3.7-14.2) times higher with a Masimo device than a Lifebox device. Similarly, assessors aged >25 years were 4.8 (95% CI = 1.2, 18.6) times more likely to obtain a successful measurement within 60 seconds. The odds of obtaining a successful measurement was 2.6 (95% CI = 1.6, 4.2) times higher among children aged 12-59 months compared to 2-11 months. Conclusions: Our study indicated that assessors could achieve the necessary skills to perform pulse oximetry successfully in real-life inpatient settings through a short training module, with some effect of device-, provider- and patient-related factors. The National IMCI Programme of Bangladesh can use these findings for finalising the national IMCI training modules and implementation package incorporating the recommendation of using pulse oximetry for childhood pneumonia assessment.


Subject(s)
Child, Hospitalized , Pneumonia , Bangladesh , Child , Humans , Hypoxia , Oximetry , Pneumonia/diagnosis
4.
BMC Pregnancy Childbirth ; 21(Suppl 1): 233, 2021 Mar 26.
Article in English | MEDLINE | ID: mdl-33765963

ABSTRACT

BACKGROUND: Policymakers need regular high-quality coverage data on care around the time of birth to accelerate progress for ending preventable maternal and newborn deaths and stillbirths. With increasing facility births, routine Health Management Information System (HMIS) data have potential to track coverage. Identifying barriers and enablers faced by frontline health workers recording HMIS source data in registers is important to improve data for use. METHODS: The EN-BIRTH study was a mixed-methods observational study in five hospitals in Bangladesh, Nepal and Tanzania to assess measurement validity for selected Every Newborn coverage indicators. We described data elements required in labour ward registers to track these indicators. To evaluate barriers and enablers for correct recording of data in registers, we designed three interview tools: a) semi-structured in-depth interview (IDI) guide b) semi-structured focus group discussion (FGD) guide, and c) checklist assessing care-to-documentation. We interviewed two groups of respondents (January 2018-March 2019): hospital nurse-midwives and doctors who fill ward registers after birth (n = 40 IDI and n = 5 FGD); and data collectors (n = 65). Qualitative data were analysed thematically by categorising pre-identified codes. Common emerging themes of barriers or enablers across all five hospitals were identified relating to three conceptual framework categories. RESULTS: Similar themes emerged as both barriers and enablers. First, register design was recognised as crucial, yet perceived as complex, and not always standardised for necessary data elements. Second, register filling was performed by over-stretched nurse-midwives with variable training, limited supervision, and availability of logistical resources. Documentation complexity across parallel documents was time-consuming and delayed because of low staff numbers. Complete data were valued more than correct data. Third, use of register data included clinical handover and monthly reporting, but little feedback was given from data users. CONCLUSION: Health workers invest major time recording register data for maternal and newborn core health indicators. Improving data quality requires standardised register designs streamlined to capture only necessary data elements. Consistent implementation processes are also needed. Two-way feedback between HMIS levels is critical to improve performance and accurately track progress towards agreed health goals.


Subject(s)
Data Collection/statistics & numerical data , Documentation/statistics & numerical data , Hospitals/statistics & numerical data , Perinatal Care/organization & administration , Registries/statistics & numerical data , Bangladesh/epidemiology , Data Accuracy , Female , Health Personnel/organization & administration , Health Personnel/statistics & numerical data , Humans , Infant, Newborn , Maternal Death/prevention & control , Nepal/epidemiology , Perinatal Care/statistics & numerical data , Perinatal Death/prevention & control , Pregnancy , Stillbirth , Tanzania/epidemiology