Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE Trans Med Imaging ; 37(12): 2704-2717, 2018 12.
Article in English | MEDLINE | ID: mdl-29994472

ABSTRACT

The mechanical behavior of long bones and fractures has been under investigation for many decades due to its complexity and clinical relevance. In this paper, we report a new subject-specific methodology to predict and analyze the mechanical behavior of the soft tissue at a bone interface with the intent of identifying the presence and location of bone abnormalities with high accuracy, spatial resolution, and contrast. The proposed methodology was tested on both intact and fractured rabbit femur samples with finite element-based 3-D simulations, created from actual femur computed tomography data, and ultrasound elastography experiments. The results included in this study demonstrate that elastographic strains at the bone/soft tissue interface can be used to differentiate fractured femurs from the intact ones on a distribution level. These results also demonstrate that coronal plane axial shear strain creates a unique contrast mechanism that can be used to reliably detect fractures (both complete and incomplete) in long bones. Kruskal-Wallis test further demonstrates that the contrast measure for the fracture group (simulation: 2.1286±0.2206; experiment: 2.7034 ± 1.0672) is significantly different from that for the intact group (simulation: 0 ± 0; experiment: 1.1540±0.6909) when using coronal plane axial shear strain elastography ( < 0.01). We conclude that: 1) elastography techniques can be used to accurately identify the presence and location of fractures in a long bone and 2) the proposed model-based approach can be used to predict and analyze strains at a bone fracture site and to better interpret experimental elastographic data.


Subject(s)
Elasticity Imaging Techniques/methods , Femoral Fractures/diagnostic imaging , Femur/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Animals , Biomechanical Phenomena , Finite Element Analysis , Phantoms, Imaging , Rabbits , Stress, Mechanical
2.
J Surg Res ; 210: 244-252, 2017 04.
Article in English | MEDLINE | ID: mdl-28457335

ABSTRACT

BACKGROUND: To assess the integrity of hernia repair, imaging modalities such as computed tomography or ultrasound (US) are commonly used. Neither modality has currently the capacity to simultaneously image the mesh and quantify a prosthetic and surrounding tissue stiffness. In this pilot study, we hypothesize that US shear wave elastography (SWE) can be used to identify a polyester mesh and a biologic graft and to assess their stiffness noninvasively in a rat model of bridging hernia repair. METHODS: Lewis rats underwent hernia creation and repair with Parietex or Strattice at 30 d. After 3 mo, the animals were euthanized, and the Young's Modulus was measured using SWE. Three-dimensional reconstructions of the hernia pre- and post-repair were performed using in-house image processing algorithms. RESULTS: SWE was capable of accurate and real-time assessment and diagnosis of the hernia defects in vivo. Young's Modulus of Parietex meshes and Strattice grafts as estimated from the shear wave elastograms were found to be statistically different from each other (P < 0.05). Accurate three-dimensional reconstructions of the hernia defects pre- and post-repair were generated. CONCLUSIONS: In this study, we demonstrate the feasibility of using US SWE to detect ventral hernias and evaluate mesh repair in vivo. Our results indicate that the presence of a hernia and repair can be reliably visualized by SWE and three dimensionally reconstructed. Thus, this technique may provide both structural and functional information regarding the hernia and the repair.


Subject(s)
Elasticity Imaging Techniques/methods , Hernia, Ventral/diagnostic imaging , Herniorrhaphy/instrumentation , Incisional Hernia/diagnostic imaging , Surgical Mesh , Animals , Feasibility Studies , Hernia, Ventral/surgery , Incisional Hernia/surgery , Pilot Projects , Random Allocation , Rats , Rats, Inbred Lew , Treatment Outcome
3.
Phys Med Biol ; 61(1): 131-50, 2016 Jan 07.
Article in English | MEDLINE | ID: mdl-26611328

ABSTRACT

We report on the use of elastographic imaging techniques to assess the bone/soft tissue interface, a region that has not been previously investigated but may provide important information about fracture and bone healing. The performance of axial strain elastograms and axial shear strain elastograms at the bone/soft tissue interface was studied ex vivo on intact and fractured canine and ovine tibias. Selected ex vivo results were corroborated on intact sheep tibias in vivo. The elastography results were statistically analyzed using elastographic image quality tools. The results of this study demonstrate distinct patterns in the distribution of the normalized local axial strains and axial shear strains at the bone/soft tissue interface with respect to the background soft tissue. They also show that the relative strength and distribution of the elastographic parameters change in the presence of a fracture and depend on the degree of misalignment between the fracture fragments. Thus, elastographic imaging modalities might be used in the future to obtain information regarding the integrity of bones and to assess the severity of fractures, alignment of bone fragments as well as to follow bone healing.


Subject(s)
Cartilage/diagnostic imaging , Elasticity Imaging Techniques/methods , Tibia/diagnostic imaging , Animals , Dogs , Male , Sheep
SELECTION OF CITATIONS
SEARCH DETAIL