Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
2.
Pediatr Radiol ; 54(5): 671-683, 2024 May.
Article in English | MEDLINE | ID: mdl-38231400

ABSTRACT

Primary pediatric lung tumors are uncommon and have many overlapping clinical and imaging features. In contrast to adult lung tumors, these rare pediatric neoplasms have a relatively broad histologic spectrum. Informed by a single-institution 13-year retrospective record review, we present an overview of the most common primary pediatric lung neoplasms, with a focus on the role of positron emission tomography (PET), specifically 18F-fluorodeoxyglucose (FDG) PET and 68Ga-DOTATATE PET, in the management of primary pediatric lung tumors. In addition to characteristic conventional radiographic and cross-sectional imaging findings, knowledge of patient age, underlying cancer predisposition syndromes, and PET imaging features may help narrow the differential. While metastases from other primary malignancies remain the most commonly encountered pediatric lung malignancy, the examples presented in this pictorial essay highlight many of the important conventional radiologic and PET imaging features of primary pediatric lung malignancies.


Subject(s)
Fluorodeoxyglucose F18 , Lung Neoplasms , Positron-Emission Tomography , Radiopharmaceuticals , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/therapy , Child , Positron-Emission Tomography/methods , Adolescent , Retrospective Studies , Organometallic Compounds , Diagnosis, Differential
3.
Pediatr Radiol ; 53(9): 1951-1960, 2023 08.
Article in English | MEDLINE | ID: mdl-37150788

ABSTRACT

OBJECTIVE: To delineate pediatric interventional radiology (IR) inpatient consult growth and resulting collections after implementation of a pediatric IR consult service. METHODS: An inpatient IR consult process was created at a single academic children's hospital in October 2019. IR consult note templates were created in Epic (Epic Systems Corporation, Verona, Wisconsin) and utilized by 4 IR physicians. Automatic charge generation was linked to differing levels of evaluation and management (E&M) service relating to current procedural terminology (CPT) inpatient consult codes 99251-99255. The children's hospital informatics division identified IR consult notes entered from the implementation of the consult service: October 2019 to January 2022. The university radiology department billing office provided IR service E&M charge, payment, and relative value units (RVU) information during this study period. A chart review was performed to determine the IR procedure conversion rate. Mann-Whitney and a two-sample t-test statistical analyses compared use of the 25-modifier, monthly consult growth and monthly payment growth. P-value < 0.05 was considered statistically significant.  RESULTS: Within this 27-month period, a total of 2153 inpatient IR consults were performed during 1757 Epic hospital encounters; monthly consult peak was reached 5 months into the study period. Consult level breakdown by CPT codes: 99251-8.7%, 99252-81.7%, and 99253-8.8%. 69.7% of IR consults had consult-specific billing with payments in 96.4% resulting in $143,976 new revenue. From 2020 to 2021, IR consult volume trended upward by 13.4% (P =0.069), and consult-specific payments increased by 84.1% (P<0.001). IR consult procedure conversion rate was 96.5%. CONCLUSION: An inpatient pediatric IR consult service was quickly established and maintained by four physicians over a 27-month study period. Annual IR consult volume trended upward and consult-specific payments increased, resulting in previously uncaptured IR service revenue.


Subject(s)
Physicians , Radiology, Interventional , Child , Humans , Inpatients , Referral and Consultation
4.
Pediatr Radiol ; 52(8): 1581-1591, 2022 07.
Article in English | MEDLINE | ID: mdl-35460037

ABSTRACT

A central venous catheter is typically made of silicone rubber or polyurethane and inserted into a large central vein to provide prolonged and direct access to central venous circulation. These catheters provide a safe and effective method to administer intravenous medications, nutritional supplements, fluids and blood products. However, a myriad of complications is associated with central venous catheters, including, but not limited to, mechanical malfunction or fracture, kinking, erroneous placement, line infection, fibrin sheath formation and venous thrombosis. Following clinical and radiographic evaluation, contrast-enhanced line studies constitute the next best diagnostic tool to assess the functionality of central venous catheters. However, there is a lack of standardization in the literature outlining how these studies should be performed. In addition, the interpretation of these studies can be problematic for general pediatric radiologists, many of whom are often not familiar with placement or manipulation of these catheters. In this pictorial review, we highlight the challenges associated with performing and interpreting fluoroscopically guided contrast injection studies, using case studies drawn from a large tertiary children's hospital database for illustration. Revealing these challenges and understanding their causative mechanisms can improve the performance of these line studies.


Subject(s)
Catheterization, Central Venous , Catheterization, Peripheral , Central Venous Catheters , Catheterization, Central Venous/methods , Catheterization, Peripheral/methods , Catheters, Indwelling , Child , Humans , Radiologists , Retrospective Studies
5.
Pediatr Radiol ; 52(8): 1492-1499, 2022 07.
Article in English | MEDLINE | ID: mdl-35386015

ABSTRACT

BACKGROUND: Assessment of the ureter is a fundamental part of the radiologic evaluation of the urinary tract. Abnormal ureteral dilation warrants further investigation to assess the etiology, which includes obstruction and/or reflux. Despite this fundamental need, there are no established normative values in children based on imaging. OBJECTIVE: To provide normative values for ureteral diameter in pediatric patients with age-related ranges. MATERIALS AND METHODS: We retrospectively reviewed all magnetic resonance (MR) urography studies and chose only normal ureters for assessment. The images were analyzed on commercially available software to assess maximum internal diameter. Manual measurements were done in cases where the images were below the resolution for automated assessment. Maximum intraluminal ureteral diameters were measured in upper, mid and lower thirds and the average of the three maximum ureteral diameters was used to obtain the average widest internal ureteral diameter. Multivariable linear regression was performed to test the association between the calculated diameter and gender. Differences in sizes between the left and right ureter were assessed using paired Wilcoxon signed rank test. RESULTS: One hundred twenty-one MR urography studies were selected, which included 160 ureter units. The diameter increases progressively with age, ranging from 3.2 mm during infancy to 5.0 mm in patients older than 16 years of age. After 9 years of age, the average widest internal ureteral diameter is slightly larger in males compared to females (odds ratio [OR]=1.91, 95% confidence interval [CI] [1.63, 2.25], P<0.0001). The right ureter was slightly larger than the left (3.9 mm vs. 3.7 mm, P=0.004) among 39 patients in whom both right and left ureter units were included. The average mid ureteral diameter is widest, followed by the distal third then proximal third. CONCLUSION: We present the normative values for the average widest internal ureteral diameter based on laterality and different segments. In the pediatric population, 3.8 mm should be considered the average widest internal ureteral diameter.


Subject(s)
Ureter , Adolescent , Child , Dilatation, Pathologic , Female , Humans , Male , Retrospective Studies , Ureter/diagnostic imaging , Ureter/pathology
6.
Pediatr Radiol ; 52(10): 1948-1962, 2022 09.
Article in English | MEDLINE | ID: mdl-35476071

ABSTRACT

Mediastinal masses are commonly identified in the pediatric population with cross-sectional imaging central to the diagnosis and management of these lesions. With greater anatomical definition afforded by cross-sectional imaging, classification of mediastinal masses into the traditional anterior, middle and posterior mediastinal compartments - as based on the lateral chest radiograph - has diminishing application. In recent years, the International Thymic Malignancy Interest Group (ITMIG) classification system of mediastinal masses, which is cross-sectionally based, has garnered acceptance by multiple thoracic societies and been applied in adults. Therefore, there is a need for pediatric radiologists to clearly understand the ITMIG classification system and how it applies to the pediatric population. The main purpose of this article is to provide an updated review of common pediatric mediastinal masses and mediastinal manifestations of systemic disease processes in the pediatric population based on the new ITMIG classification system.


Subject(s)
Mediastinal Neoplasms , Thymus Neoplasms , Adult , Child , Humans , Mediastinal Neoplasms/diagnostic imaging , Mediastinum/diagnostic imaging , Public Opinion , Thymus Neoplasms/diagnostic imaging , Thymus Neoplasms/pathology , Tomography, X-Ray Computed
7.
Pediatr Radiol ; 51(13): 2588-2595, 2021 12.
Article in English | MEDLINE | ID: mdl-34254153

ABSTRACT

BACKGROUND: Spinal administration of medications is challenging in patients with complete posterior spinal fusion. We describe percutaneous image-guided intrathecal port placement for administration of the antisense oligonucleotide nusinersen for children and young adults with spinal muscular atrophy. OBJECTIVE: To describe and present our initial experience with a new technique for administering nusinersen in patients with spinal muscular atrophy and posterior spinal fusion. MATERIALS AND METHODS: We reviewed medical records of 13 patients who received intrathecal ports using DynaCT, biplane fluoroscopy and iGuide from April 2018 through June 2019, and we describe the clinical course over 1 year. RESULTS: Image-guided catheter and port implantation was successful in all cases. Two ports were subsequently removed, one for persistent cerebrospinal fluid leak and one for superficial infection. The other 11 have functioned successfully for a minimum of 23 months. CONCLUSION: We report our experience with image-guided intrathecal port placement in children with complete posterior spine fusion. The implanted port permits dosing in an outpatient setting and avoids the need for multiple future radiologic procedures, and it reduces discomfort, procedural costs and potential risks and sequelae of multiple anesthetics and radiation exposures. Further studies are needed to define the relative risks and benefits of intrathecal ports compared to other approaches such as repeated transforaminal lumbar punctures.


Subject(s)
Muscular Atrophy, Spinal , Spinal Fusion , Catheters , Child , Humans , Injections, Spinal , Muscular Atrophy, Spinal/diagnostic imaging , Muscular Atrophy, Spinal/drug therapy , Oligonucleotides
8.
Eur J Radiol Open ; 7: 100291, 2020.
Article in English | MEDLINE | ID: mdl-33304940

ABSTRACT

BACKGROUND: A multidisciplinary team approach to the management of esophageal cancer patients leads to better clinical decisions. PURPOSE: The contribution of CT, endoscopic and laparoscopic ultrasound to clinical staging and treatment selection by multidisciplinary tumor boards (MTB) in patients with esophageal cancer is well documented. However, there is a paucity of data addressing the role that FDG-PET/CT (PET/CT) plays to inform the clinical decision-making process at MTB conferences. The aim of this study was to assess the impact and contribution of PET/CT to clinical management decisions and to the plan of care for esophageal cancer patients at the MTB conferences held at our institution. MATERIALS AND METHODS: This IRB approved study included all the cases discussed in the esophageal MTB meetings over a year period. The information contributed by PET/CT to MTB decision making was grouped into four categories. Category I, no additional information provided for clinical management; category II, equivocal and misguiding information; category III, complementary information to other imaging modalities, and category IV, information that directly changed clinical management. The overall impact on management was assessed retrospectively from prospectively discussed clinical histories, imaging, histopathology, and the official minutes of the MTB conferences. RESULTS: 79 patients (61 males and 18 females; median age, 61 years, range, 33-86) with esophageal cancer (53 adenocarcinomas and 26 squamous cell carcinomas) were included. The contribution of PET/CT-derived information was as follows: category I in 50 patients (63%); category II in 3 patients (4%); category III in 8 patients (10%), and category IV information in 18 patients (23%). Forty-five patients (57%) had systemic disease, and in 5 (11%) of these, metastatic disease was only detected by PET/CT. In addition, PET/CT detected previously unknown recurrence in 4 (9%) of 43 patients. In summary, PET/CT provided clinically useful information to guide management in 26 of 79 esophageal cancer patients (33%) discussed at the MTB. CONCLUSION: The study showed that PET/CT provided additional information and changed clinical management in 1 out of 3 (33%) esophageal cancer cases discussed at MTB conferences. These results support the inclusion whenever available, of FDG-PET/CT imaging information to augment and improve the patient management decision process in MTB conferences.

9.
Environ Monit Assess ; 170(1-4): 59-63, 2010 Nov.
Article in English | MEDLINE | ID: mdl-19888661

ABSTRACT

A sensitive adsorptive stripping voltammetric method for the determination of simeton with universal buffer solution has been described. The method was based on the adsorption accumulation of simeton at a hanging mercury drop electrode. The overall reduction process is under controlled diffusion. The adsorptive peak was observed at -0.8 V vs SCE in acidic solution 2

Subject(s)
Electrochemical Techniques/methods , Herbicides/analysis , Soil Pollutants/analysis , Triazines/analysis , Vegetables/chemistry , Environmental Monitoring , Herbicides/chemistry , Pesticide Residues/analysis , Pesticide Residues/chemistry , Soil Pollutants/chemistry , Triazines/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...