1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(4): 430-433, 2024 Jul 30.
Article in Chinese | MEDLINE | ID: mdl-39155258

ABSTRACT

Objective: To investigate the impact of different infusion media on the flow rate of infusion pumps. Methods: Ten infusion pumps were randomly selected and tested for infusion rates using deionized water, saline solution, glucose solution, and parenteral nutrition solution. The infusion flow rate was set at 30 mL/h, and the testing methodology conformed to the standards for the calibration and quality control of syringe pumps and infusion pumps. Results: For infusion set A, the infusion rate was unaffected by the infusion media, remaining within the acceptable quality control standards. For infusion set B, when infused with deionized water, saline solution, and glucose solution, the infusion errors were within the quality control standards. However, when using parenteral nutrition solution as the infusion medium, the infusion error exceeded the acceptable quality control standards. Conclusion: Both the infusion set and the infusion medium can affect the flow rate of infusion pumps. It is crucial to calibrate the flow rate according to the specific infusion medium to reduce medical risks associated with infusion pumps during clinical use.


Subject(s)
Infusion Pumps , Glucose/administration & dosage , Saline Solution/administration & dosage , Quality Control , Calibration , Parenteral Nutrition Solutions , Water
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(1): 111-113, 2024 Jan 30.
Article in Chinese | MEDLINE | ID: mdl-38384229

ABSTRACT

Objective: To explore the effect of routine reusable pipeline and disposable pipeline on ventilator quality control results. Methods: 17 ventilators were randomly selected to conduct quality control using routine reusable pipeline and disposable pipeline respectively. Quality control data were recorded and then paired t-test method was used to analyze whether the difference between the two pipelines was significant or not. Results: There were no significant differences in respiratory rate, tidal volume and end airway pressure between the two types of pipes ( P>0.05). The airway peak pressure of routine reusable pipeline was significantly higher than disposable pipeline ( P<0.05), but the difference was very small, only about 0.2 mbar which would not affect the conclusion of quality control. Conclusion: Quality control of ventilator is not affected by routine reusable pipeline and disposable pipeline, which can be replaced by each other.


Subject(s)
Disposable Equipment , Ventilators, Mechanical , Tidal Volume
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 47(2): 229-232, 2023 Feb 08.
Article in Chinese | MEDLINE | ID: mdl-37096483

ABSTRACT

OBJECTIVE: To combine data analysis and data visualization with medical devices, provide a set of data analysis and data visualization solutions. This solutions can deeply excavate the data of the whole life cycle of medical equipment, and then play a guiding role in business. METHODS: With the help of mature tools in the Internet field, YIYI and YOUSHU, we can quickly complete data collection and rich visualization effects, and introduce the concept of data analysis to deeply mine data. RESULTS: Taking the maintenance data of infusion pump as an example, the data collection is completed through YIYI, and the maintenance system is built on YOUSHU. CONCLUSIONS: The maintenance system of infusion pump system is simple and clear, with good visualization effect. It can quickly analyze maintenance failures, reduce maintenance times and maintenance costs, ensure the safety of the equipment. Moreover, the system can be easily transferred to other medical equipment, and can carry on the whole life cycle data research.


Subject(s)
Data Visualization , Infusion Pumps , Costs and Cost Analysis , Data Analysis
4.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(4): 255-258, 2019 Jul 30.
Article in Chinese | MEDLINE | ID: mdl-31460715

ABSTRACT

In this paper, the classification and location of neuroblastoma in NMR images are realized by using Deep Neural Network(CNN) algorithm as the core technology. The module is integrated to realize the development of computer-aided diagnostic software. It is used to make up for the gap in the field of intelligent identification and accurate positioning of neuroblastoma in the current nuclear magnetic resonance detection technology, effectively reduce the work intensity of doctors reading films, and further promote the clinical application and technical development of nuclear magnetic resonance detection technology in the diagnosis of neuroblastoma.


Subject(s)
Algorithms , Deep Learning , Neuroblastoma , Humans , Magnetic Resonance Imaging , Neural Networks, Computer , Neuroblastoma/diagnostic imaging
5.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(2): 150-153, 2019 Mar 30.
Article in Chinese | MEDLINE | ID: mdl-30977619

ABSTRACT

Based on the Kraljic model,this paper established the scoring standard system for medical equipment procurement,and determined the weight coefficients of each evaluation factor by the analytic hierarchy process (AHP),then the procurement classification model of medical equipment was successfully established.It is proved that this model can classify medical equipment effectively,which enables the purchasing personnel to adopt corresponding purchasing strategies according to different classification.This model can be extended to all medical equipment procurement,realizing the delicacy and individualized procurement management of the equipment,which has strong operability and guiding significance.


Subject(s)
Equipment and Supplies , Equipment and Supplies/economics , Models, Theoretical
6.
Zhongguo Yi Liao Qi Xie Za Zhi ; 42(4): 259-261, 2018 Jul 30.
Article in Chinese | MEDLINE | ID: mdl-30112889

ABSTRACT

This study is aimed to design the testing system of multiple parameters of the incubators, and to make their quality control plans. Also it is required to establish a model of data collection and processing based on MCU, and to program the host computer software in order to analyze data. The result shows that the testing system is accurate and stable; also it is convenient to collect the data. This testing system is a good complement of the quality control of incubators. It has a high practical value in improving medical safety and reducing the occurrence of adverse events.


Subject(s)
Incubators, Infant/standards , Quality Control , Software , Incubators , Infant, Premature
7.
Zhongguo Yi Liao Qi Xie Za Zhi ; 42(4): 303-304, 2018 Jul 30.
Article in Chinese | MEDLINE | ID: mdl-30112902

ABSTRACT

With the continuous improvement and wide application of hospital information, more and more medical equipment is integrated into the hospital information systems, which brings new work contents and challenges for the traditional clinical engineers. This paper reviews and evaluates the current situation of networked medical equipment in the hospital. By applying the ISO 80001 and the MDS2(Manufacturer Disclosore Statement for Medical Device Security), the paper puts forward the measures and suggestions for the security management of networked medical equipment.


Subject(s)
Equipment Safety , Hospital Information Systems , Equipment and Supplies , Safety Management
8.
Zhongguo Yi Liao Qi Xie Za Zhi ; 42(3): 173-175, 2018 May 30.
Article in Chinese | MEDLINE | ID: mdl-29885121

ABSTRACT

This paper proposes a clinical alarm management system based on the theory of the closed loop control. The alarm management mechanism can be divided into the expected standard, improving execution rule, rule execution, medical devices with alarm functions, results analysis strategy and the output link. And, we make relevant application and discussion. Results showed that the mechanism can be operable and effective.


Subject(s)
Clinical Alarms , Decision Support Systems, Clinical
9.
Zhongguo Yi Liao Qi Xie Za Zhi ; 41(6): 460-463, 2017 Nov 30.
Article in Chinese | MEDLINE | ID: mdl-29862712

ABSTRACT

OBJECTIVES: The article aims at survey and analysis on ventilator alarm status in pediatric hospital. METHODS: First, we design the statistical table of ventilator, and analyze the reliability of statistical table. Then we evaluate the effectiveness of the alarm. Finally, we evaluate the alarm information synthetically through investigation and statistics. RESULTS: The ventilator alarm is ineffective, a large number of nonsensical alarms, leading to lower alert sensitivity of medical staff. CONCLUSIONS: According to the survey results, we should analyze the cause of the problem, and propose the corresponding alarm management method.


Subject(s)
Clinical Alarms , Intensive Care Units , Respiration, Artificial/instrumentation , Child , Humans , Monitoring, Physiologic , Reproducibility of Results , Surveys and Questionnaires
10.
Zhongguo Yi Liao Qi Xie Za Zhi ; 40(1): 13-6, 2016 Jan.
Article in Chinese | MEDLINE | ID: mdl-27197489

ABSTRACT

The content related to the quality during life-cycle in operation of medical device includes daily use, repair volume, preventive maintenance, quality control and adverse event monitoring. In view of this, the article aims at discussion on the quality evaluation method of medical devices during their life cycle in operation based on the Analytic Hierarchy Process (AHP). The presented method is proved to be effective by evaluating patient monitors as example. The method presented in can promote and guide the device quality control work, and it can provide valuable inputs to decisions about purchase of new device.


Subject(s)
Decision Support Techniques , Durable Medical Equipment/standards , Equipment Design , Quality Control
11.
Zhongguo Yi Liao Qi Xie Za Zhi ; 39(4): 265-7, 2015 Jul.
Article in Chinese | MEDLINE | ID: mdl-26665946

ABSTRACT

As the dressings currently used in clinic settings unflat shape in general, they can't be fitted completely on occiput, heel, elbow, knee and other body parts unflat. This paper developed one kind of foam dressing of special shape based on local anatomy. The foam dressing is waterproof and air permeable, it can cover the wound closely enough to prevent bacteria from invasion and infection. With a saturated absorption ratio of 1: 8 or higher, it can keep the wound clean and moisture by absorbing large amounts of wound inflammatory secretions and is almost completely permeable to oxygen and carbon dioxide. Assuring safety and effect meanwhile, it has better outcomes than common dressings in the same application settings.


Subject(s)
Bandages , Wound Healing
12.
Zhongguo Yi Liao Qi Xie Za Zhi ; 38(4): 270-3, 2014 Jul.
Article in Chinese | MEDLINE | ID: mdl-25330608

ABSTRACT

This paper analyzed current problems and challenges facing hospitals in alarm management both abroad and at home. Based on a survey conducted on alarm management in hospitals, plus an analysis on different kinds of data interfaces and data exchange protocols of the medical equipment used in ICUs, a solution of alarm management is put forwarded which is based on alarm information integration and processing. It aims at improving medical equipment alarm management and reducing relevant adverse events.


Subject(s)
Clinical Alarms , Electronic Data Processing , Intensive Care Units
13.
Zhongguo Yi Liao Qi Xie Za Zhi ; 34(5): 386-8, 2010 Sep.
Article in Chinese | MEDLINE | ID: mdl-21179722

ABSTRACT

Investigated and analyzed the graphical symbols commonly used in medical equipment, their benefits and drawbacks. From the perspective of human factors engineering, some root causes of poor pictogram as well as their relations with medical equipment adverse events were addressed. Furthermore, how to deal with the problems with current pictogram aiming at reducing use error was also discussed.


Subject(s)
Equipment and Supplies , Product Labeling , Equipment Design
14.
Zhongguo Yi Liao Qi Xie Za Zhi ; 29(1): 54-6, 2005 Jan.
Article in Chinese | MEDLINE | ID: mdl-15875697

ABSTRACT

Based on the structure and principle of transducers for medical ventilators, this paper analyzes the causes of transducers' failures, and introduces some corresponding calibration methods. Besides, some suggestions about how to reduce different kind of transducer failures are put forward.


Subject(s)
Respiration, Artificial/instrumentation , Transducers , Ventilators, Mechanical , Calibration , Equipment Failure , Equipment Failure Analysis/methods , Equipment Failure Analysis/standards , Equipment Safety/methods , Maintenance