Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Polymers (Basel) ; 15(21)2023 Oct 24.
Article in English | MEDLINE | ID: mdl-37959881

ABSTRACT

Chronic wounds and the failure of conventional treatment are relatively common in veterinary medicine. Recently, there has been a growing interest in alternative therapeutic approaches and the utilization of biodegradable materials. Their potential application in wound therapy may offer a novel and more suitable option compared to conventional treatment methods. Biodegradable materials can be classified into two main categories: natural, synthetic, and a combination of both, which have the potential to have synergistically enhanced properties. In this study, four domestic dogs with clinical symptoms of chronic wounds were enrolled. These wounds underwent treatment utilizing a novel biodegradable composite material composed of gelatin sponge combined with two electrospun layers of polycaprolactone (PCL) along with polyvinylpyrrolidone (PVP) fibers containing povidone-iodine complex (PVP-I). The initial phase of the study was dedicated to evaluating the antibacterial properties of iodine against Staphylococcus aureus and Escherichia coli. On average, wound healing in domestic dogs took 22 days from the initial treatment, and iodine concentrations demonstrated a significant antibacterial effect against Escherichia coli and Staphylococcus aureus. Based on the favorable outcomes observed in wound management, we believe that the utilization of a blend of natural and synthetic biodegradable materials holds promise as an effective wound therapy option.

2.
Nanomaterials (Basel) ; 12(16)2022 Aug 17.
Article in English | MEDLINE | ID: mdl-36014682

ABSTRACT

The present study is focused on the synthesis and structural properties of amorphous terbium metal-organic framework thin film (TbMOF-TF) and its transformation to terbium oxide by pyrolysis at 450 °C in the air. The crystalline (cTbMOF) and amorphous (aTbMOF) films were prepared by solvothermal synthesis using different amounts (0.4 and 0.7 mmol) of the modulator (sodium acetate), respectively. The powders were characterized by differential scanning calorimetry (DSC), thermogravimetry (TG), Fourier transform infrared (FTIR), Raman spectroscopy, and scanning electron microscopy (SEM). The varied chemical composition of the surface of TbMOFs and TbxOy was investigated by X-ray photoelectron spectroscopy (XPS). X-ray diffraction (XRD) and transmission electron microscopy (TEM) revealed that aTbMOF had been fully transformed to a Tb4O7 phase with a cubic crystal structure at 450 °C. The amorphous aTbMOF-TF film was prepared by dropping a colloidal solution of amorphous precursor nanocrystals on the SiO2/Si substrates covered with Pt as an interlayer. XPS confirmed the presence of Tb in two states, Tb3+ and Tb4+. The amorphous film has a rough, porous microstructure and is composed of large clusters of worm-like particles, while terbium oxide film consists of fine crystallites of cubic fluorite cF-TbOx, c-Tb4O7, and c-Tb2O3 phases. The surface topography was investigated by a combination of confocal (CM) and atomic force microscopy (AFM). The amorphous film is porous and rough, which is contrast to the crystalline terbium oxide film.

3.
Sci Rep ; 12(1): 3460, 2022 03 02.
Article in English | MEDLINE | ID: mdl-35236912

ABSTRACT

Polymer-coated metals may act as biodegradable orthopedic implants with adjustable corrosion rates. Metallic surfaces represent a dynamic system with specific interactions occurring after the material is implanted into the human body. An additional layer, in the form of polymeric thin film, changes the nature of this metal-body fluids interface. Moreover, the interaction between polymer and metal itself can differ for various systems. Iron-based material modified with a thin layer of polyethyleneimine (PEI) coating was prepared and studied as potential absorbable implant. Computational methods were employed to study the interaction between the metallic surface and polymer functional monomer units at atomic levels. Various spectroscopical and optical methods (SEM, AFM, Confocal, and Raman spectroscopy) were also used to characterize prepared material. Electrochemical measurements have been chosen to study the polymer adsorption process onto the iron surface and corrosion behavior which is greatly influenced by the PEI presence. The adsorption mechanism of PEI onto iron was proposed alongside the evaluation of Fe and Fe-PEI degradation behavior studied using the impedance method. Bonding via amino -NH2 group of PEI onto Fe and enhanced corrosion rate of coated samples were observed and confirmed.


Subject(s)
Iron , Polyethyleneimine , Absorbable Implants , Corrosion , Humans , Metals , Polymers/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL