Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Clin Chim Acta ; 559: 119677, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38636694

ABSTRACT

BACKGROUND: Daratumumab (DARA) is a commonly used monoclonal antibody (mAb) drug for the treatment of multiple myeloma (MM). Its appearance as a visible abnormal band in the γ-region of a serum protein electrophoresis (SPEP) gel may interfere with the SPEP result interpretation. With the advantages of portability and rapid testing capabilities, up-conversion fluorescence lateral-flow immunoassay (LFA) can be an ideal solution to detect DARA interference. METHODS: An up-conversion fluorescence LFA strip was designed and constructed to perform semi-quantitative DARA testing in clinical samples. The LFA strip test was evaluated for limit of detection (LOD), dynamic range, and analytical interference. RESULTS: To demonstrate the clinical utility of the LFA strip, 43 SPEP-positive patient serum samples were tested for the presence of DARA, and the results exactly matched the DARA usage history in patient medical records. CONCLUSIONS: The performance of the up-conversion fluorescence LFA strip meets the purpose of clarifying DARA interference in SPEP results. It may be used as an independent and objective confirmation of the presence of DARA in clinical samples. The LFA strip offers a cost-effective rapid on-site test to check for DARA interference alongside standard SPEP equipment, which significantly improves the interpretation of ambiguous SPEP results involving DARA, and does not intervene the current SPEP workflow in clinical laboratory practice.

2.
Sci Rep ; 13(1): 14974, 2023 09 11.
Article in English | MEDLINE | ID: mdl-37696850

ABSTRACT

Cerebrospinal fluid (CSF) leak can be diagnosed in clinical laboratories by detecting a diagnostic marker ß2-transferrin (ß2-Tf) in secretion samples. ß2-Tf and the typical transferrin (Tf) proteoform in serum, ß1-transferrin (ß1-Tf), are Tf glycoforms. An innovative affinity capture technique for sample preparation, called microprobe-capture in-emitter elution (MPIE), was incorporated with high-resolution mass spectrometry (HR-MS) to study the Tf glycoforms and the primary structures of ß1-Tf and ß2-Tf. To implement MPIE, an analyte is first captured on the surface of a microprobe, and subsequently eluted from the microprobe inside an electrospray emitter. The capture process is monitored in real-time via next-generation biolayer interferometry (BLI). When electrospray is established from the emitter to a mass spectrometer, the analyte is immediately ionized via electrospray ionization (ESI) for HR-MS analysis. Serum, CSF, and secretion samples were analyzed using MPIE-ESI-MS. Based on the MPIE-ESI-MS results, the primary structures of ß1-Tf and ß2-Tf were elucidated. As Tf glycoforms, ß1-Tf and ß2-Tf share the amino acid sequence but contain varying N-glycans: (1) ß1-Tf, the major serum-type Tf, has two G2S2 N-glycans on Asn413 and Asn611; and (2) ß2-Tf, the major brain-type Tf, has an M5 N-glycan on Asn413 and a G0FB N-glycan on Asn611. The resolving power of the innovative MPIE-ESI-MS method was demonstrated in the study of ß2-Tf as well as ß1-Tf. Knowing the N-glycan structures on ß2-Tf allows for the design of more novel test methods for ß2-Tf in the future.


Subject(s)
Brain , Transferrin , Humans , Amino Acid Sequence , Cerebrospinal Fluid Leak , Mass Spectrometry
3.
J Clin Virol ; 164: 105468, 2023 07.
Article in English | MEDLINE | ID: mdl-37119583

ABSTRACT

BACKGROUND: Tests that sensitively detect the presence of actively replicating SARS-CoV-2 may improve patient care by allowing the safe and timely discontinuation of isolation. Correlates of active replication include nucleocapsid antigen and virus minus-strand RNA. METHODS: Qualitative agreement of the DiaSorin LIAISON SARS-CoV-2 nucleocapsid antigen chemiluminescent immunoassay (CLIA) with minus-strand RNA was determined using 402 upper respiratory specimens from 323 patients previously tested using a laboratory-developed SARS-CoV-2 strand-specific RT-qPCR. Nucleocapsid antigen levels, minus-strand and plus-strand cycle threshold values, as well as virus culture, were used to evaluate discordant specimens. Receiver operating characteristic curves were also used to identify virus RNA thresholds for active replication, including values harmonized to the World Health Organization International Standard. RESULTS: Overall agreement was 92.0% [95% confidence interval (CI): 89.0 - 94.5], positive percent agreement was 90.6% (95% CI: 84.4 - 95.0), and negative percent agreement was 92.8% (95% CI: 89.0 - 95.6). The kappa coefficient was 0.83 (95% CI: 0.77 - 0.88). Discordant specimens contained low levels of nucleocapsid antigen and minus-strand RNA. 84.8% (28/33) were negative by culture. Sensitivity-optimized plus-strand RNA thresholds for active replication were 31.6 cycles or 3.64 log10 IU/mL; resulting in 100.0% sensitivity (95% CI: 97.6 to 100.0) and 55.9 specificity (95% CI: 49.7 to 62.0). CONCLUSIONS: Detection of nucleocapsid antigen by CLIA performs equivalently to minus-strand detection via strand-specific RT-qPCR, though these methods may overestimate replication-competent virus compared to culture. Careful implementation of biomarkers for actively replicating SARS-CoV-2 has the potential to inform infection control decision-making and patient management.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2/genetics , Nucleocapsid , Polymerase Chain Reaction , RNA, Viral/genetics , Sensitivity and Specificity , COVID-19 Testing
4.
J Mass Spectrom Adv Clin Lab ; 28: 99-104, 2023 Apr.
Article in English | MEDLINE | ID: mdl-36937810

ABSTRACT

Introduction: Therapeutic drug monitoring (TDM) of immunosuppressants is essential for optimal care of transplant patients. Immunoassays and liquid chromatography-mass spectrometry (LC-MS) are the most commonly used methods for TDM. However, immunoassays can suffer from interference from heterophile antibodies and structurally similar drugs and metabolites. Additionally, nominal-mass LC-MS assays can be difficult to optimize and are limited in the number of detectable compounds. Objectives: The aim of this study was to implement a mass spectrometry-based test for immunosuppressant TDM using online solid-phase extraction (SPE) and accurate-mass full scan-single ion monitoring (FS-SIM) data acquisition mode. Methods: LC-MS analysis was performed on a TLX-2 multi-channel HPLC with a Q-Exactive Plus mass spectrometer. TurboFlow online SPE was used for sample clean up. The accurate-mass MS was set to positive electrospray ionization mode with FS-SIM for quantitation of tacrolimus, sirolimus, everolimus, and cyclosporine A. MS2 fragmentation pattern was used for compound confirmation. Results: The method was validated in terms of precision, analytical bias, limit of quantitation, linearity, carryover, sample stability, and interference. Quantitation of tacrolimus, sirolimus, everolimus, and cyclosporine A correlated well with results from an independent reference laboratory (r = 0.926-0.984). Conclusions: Accurate-mass FS-SIM can be successfully utilized for immunosuppressant TDM with good correlation with results generated by standard methods. TurboFlow online SPE allows for a simple "protein crash and shoot" sample preparation protocol. Compared to traditional MRM, analyte quantitation by FS-SIM facilitates a streamlined assay optimization process.

5.
Clin Chem ; 69(1): 56-67, 2023 01 04.
Article in English | MEDLINE | ID: mdl-36308334

ABSTRACT

BACKGROUND: Identification of hemoglobin (Hb) variants is of significant value in the clinical diagnosis of hemoglobinopathy. However, conventional methods for identification of Hb variants in clinical laboratories can be inadequate due to the lack of structural characterization. We describe the use of neutral-coating capillary electrophoresis coupled with high-resolution mass spectrometry (CE-HR-MS) to achieve high-performance top-down identification of Hb variants. METHODS: An Orbitrap Q-Exactive Plus mass spectrometer was coupled with an ECE-001 capillary electrophoresis (CE) unit through an EMASS-II ion source. A PS1 neutral-coating capillary was used for CE. Samples of red blood cells were lysed in water and diluted in 10 mM ammonium formate buffer for analysis. Deconvolution of raw mass spectrometry data was carried out to merge multiple charge states and isotopic peaks of an analyte to obtain its monoisotopic mass. RESULTS: The neutral-coating CE could baseline separate individual Hb subunits dissociated from intact Hb forms, and the HR-MS could achieve both intact-protein analysis and top-down analysis of analytes. A number of patient samples that contain Hb subunit variants were analyzed, and the variants were successfully identified using the CE-HR-MS method. CONCLUSIONS: The CE-HR-MS method has been demonstrated as a useful tool for top-down identification of Hb variants. With the ability to characterize the primary structures of Hb subunits, the CE-HR-MS method has significant advantages to complement or partially replace the conventional methods for the identification of Hb variants.


Subject(s)
Electrophoresis, Capillary , Hemoglobinopathies , Humans , Mass Spectrometry/methods , Electrophoresis, Capillary/methods , Erythrocytes , Hemoglobins/genetics
7.
Clin Infect Dis ; 75(1): e314-e321, 2022 08 24.
Article in English | MEDLINE | ID: mdl-35079772

ABSTRACT

BACKGROUND: An immunodiagnostic assay that sensitively detects a cell-mediated immune response to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is needed for epidemiological investigation and for clinical assessment of T- cell-mediated immune response to vaccines, particularly in the context of emerging variants that might escape antibody responses. METHODS: The performance of a whole blood interferon-gamma (IFN-γ) release assay (IGRA) for the detection of SARS-CoV-2 antigen-specific T cells was evaluated in coronavirus disease 2019 (COVID-19) convalescents tested serially up to 10 months post-infection and in healthy blood donors. SARS-CoV-2 IGRA was applied in contacts of households with index cases. Freshly collected blood in the lithium heparin tube was left unstimulated, stimulated with a SARS-CoV-2 peptide pool, and stimulated with mitogen. RESULTS: The overall sensitivity and specificity of IGRA were 84.5% (153/181; 95% confidence interval [CI]: 79.0-89.0) and 86.6% (123/142; 95% CI: 80.0-91.2), respectively. The sensitivity declined from 100% (16/16; 95% CI: 80.6-100) at 0.5-month post-infection to 79.5% (31/39; 95% CI: 64.4-89.2) at 10 months post-infection (P < .01). The IFN-γ response remained relatively robust at 10 months post-infection (3.8 vs 1.3 IU/mL, respectively). In 14 households, IGRA showed a positivity rate of 100% (12/12) and 65.2% (15/23), and IgG of 50.0% (6/12) and 43.5% (10/23) in index cases and contacts, respectively, exhibiting a difference of + 50% (95% CI: +25.4 to +74.6) and +21.7% (95% CI: +9.23 to +42.3), respectively. Either IGRA or IgG was positive in 100% (12/12) of index cases and 73.9% (17/23) of contacts. CONCLUSIONS: The SARS-CoV-2 IGRA is a useful clinical diagnostic tool for assessing cell-mediated immune response to SARS-CoV-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , COVID-19/diagnosis , Humans , Immunoglobulin G , Interferon-gamma Release Tests , Sensitivity and Specificity
8.
J Clin Virol ; 145: 105020, 2021 12.
Article in English | MEDLINE | ID: mdl-34736075

ABSTRACT

BACKGROUND: Our institution utilizes an antigen/antibody screening test followed by a confirmatory antibody assay for preliminary positive results. Given the low prevalence for HIV infections in our institution's county, we suspect that a substantial portion of the reactive screens are false positives. OBJECTIVES: We aimed to characterize the false positivity rate of the HIV screening test performed at Stanford Health Care. In parallel, we modified our reporting workflow to release both the screening and confirmatory results simultaneously to mitigate the stress of a presumptive positive test. STUDY DESIGN: We reviewed 45,296 eligible HIV screen specimens that underwent the Abbott ARCHITECT™ 4th generation HIV antigen/antibody combination assay between August 5, 2016 and March 16, 2021. Final sample signal/cutoff (S/CO) ratios ≥ 1 were deemed positive, which triggers a reflex order for the confirmatory Bio-Rad Geenius™ HIV 1/2 Supplemental Assay. Additional chart review was performed for positive screen cases with negative or indeterminate confirmatory results. RESULTS: Our institution demonstrated a 0.28% (128/45,296) positive screen rate, with 12.5% (16/128) of these samples confirmed as false positives based on a negative HIV-1 RNA test. Median S/CO ratios of true positive screens were significantly higher than those with negative or indeterminate confirmatory tests (602.27vs 2.98; p = 0.0000323). We implemented a new synchronized reporting system for positive screens, which co-releases screen and confirmatory reports without compromise in the overall turnaround time. CONCLUSIONS: Our study demonstrates a relatively high percentage of false positive screens. Subsequently, by providing a more complete picture up front, our new reporting pipeline may reduce anxiety of a stand-alone positive screen and optimize downstream clinical decision-making.


Subject(s)
HIV Infections , HIV-1 , Algorithms , HIV Antibodies , HIV Infections/diagnosis , HIV Infections/epidemiology , HIV-2 , Humans , Mass Screening , Prevalence , Sensitivity and Specificity , Workflow
9.
AACE Clin Case Rep ; 7(5): 315-319, 2021.
Article in English | MEDLINE | ID: mdl-34522772

ABSTRACT

OBJECTIVE: Severe hypertriglyceridemia (SHTG; plasma triglycerides >1000 mg/dL) is a rare but serious complication in children who develop diabetic ketoacidosis (DKA) from uncontrolled or new-onset type 1 diabetes. METHODS: We present the case of a severely malnourished 16-year-old with a 10-month history of presumed type 2 diabetes managed with lifestyle modifications and metformin, who presented with SHTG, acute pancreatitis, and DKA. On examination, there was no evidence of lipemia retinalis, cutaneous xanthomas, or xanthelasma. He was initially treated with an insulin infusion and intravenous fluids. Despite this treatment, his pancreatitis symptoms worseneed and lipase level increased, necessitating 2 courses of plasmapheresis that immediately resolved his symptoms and dramatically improved his clinical status. He was discharged on hospital day 5. During his hospital admission, islet cell antigen 512, insulin, glutamic acid decarboxylase 65, and zinc transporter 8 autoantibodies were positive in the presence of insulinopenia, consistent with type 1 diabetes. RESULTS: Hypertriglyceridemia and hypercholesterolemia did not recur during follow-up, suggesting that the underlying mechanism for SHTG was insulin deficiency. CONCLUSION: This report of SHTG, DKA, and pancreatitis in an adolescent highlights the safe, early initiation of plasmapheresis as an effective treatment. To our knowledge, plasmapheresis has rarely been used so early in the course of treatment for an adolescent with SHTG, DKA, and acute pancreatitis.

10.
Article in English | MEDLINE | ID: mdl-34224962

ABSTRACT

Monitoring estrogen levels, especially estradiol (E2), is amongst others important for determining menopausal status and guidance of breast cancer treatment. We validated a serum E2 and estrone (E1) liquid chromatography tandem-mass spectrometry assay (LC-MS/MS) suitable for quantitation in human subjects. In addition, we compared our method with an E2 immunoassay (IA) and established preliminary reference values. Validation parameters were within the predetermined acceptance criteria. Assay linearity ranges were 4-1500 pmol/L for E1 and 4-2500 pmol/L for E2. Imprecision ranged from 7.4 to 9.6%. The lower limit of quantitation for E2 (8.0 pmol/L) was 11.4 times lower than the IA. The method comparison revealed differences in E2 quantitation up to 155% between both methods. The method allowed quantitation of E1 in all healthy volunteers, while E2 could not be detected in 95% versus 40% of the post-menopausal women using IA and LC-MS/MS, respectively. Male, pre-, peri- and postmenopausal female reference values were estimated. An LC-MS/MS based method combining E1 and E2 analysis was validated with superior E2 analytical sensitivity when compared to the IA.


Subject(s)
Chromatography, Liquid/methods , Estradiol/blood , Estrone/blood , Immunoassay/methods , Tandem Mass Spectrometry/methods , Adolescent , Adult , Female , Humans , Limit of Detection , Linear Models , Male , Menopause , Middle Aged , Reference Values , Reproducibility of Results , Young Adult
11.
Endocr Pract ; 27(11): 1114-1118, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34217894

ABSTRACT

OBJECTIVE: To evaluate the significance of antithyroglobulin and antithyroid peroxidase antibody levels associated with locoregional metastatic disease in patients with well-differentiated thyroid cancer. METHODS: Patients underwent initial treatment for well-differentiated thyroid cancer at our institution between 2014 and 2018. The following variables were collected: age, sex, pre-operative thyroid-stimulating hormone, thyroglobulin, antithyroglobulin antibody (TgAb), antithyroid peroxidase antibody (TPOAb), the extent of surgery, T-stage, N-stage, extrathyroidal extension (ETE), extranodal extension (ENE), lymphovascular invasion, and multifocal disease. The relationships between disease status and pre-operative TPOAb, TgAb, thyroglobulin, and thyroid-stimulating hormone were analyzed. RESULTS: A total of 405 patients (mean age, 52 years) were included in the study, of which 66.4% were women. Elevated TgAb was associated with the presence of lymph node metastases (LNM) in both the central and lateral neck (P < .01), with a stronger correlation to N1b versus N1a disease (P = .03). The presence of ETE was inversely related to the TgAb titer (P = .03). TPOAb was associated with a lower T-stage (P = .04), fewer LNM (P = .04), and a lower likelihood of ETE (P = .02). From multivariable analysis, TgAb ≥40 IU/mL was an independent predictive factor for a higher N-stage (P < .01 for N0 vs N1; P = .01 for N1a vs N1b), and ENE (P < .01). TPOAb ≥60 IU/mL was associated with a lower T-stage (P = .04 for T <3) and absence of ETE (P = .01). CONCLUSION: Elevated pre-operative TgAb was an independent predictor of nodal metastases and ENE, while elevated TPOAb was associated with a lower pathologic T- and N-stage. Pre-operative antithyroid antibody titers may be useful to inform the disease extent and features.


Subject(s)
Thyroglobulin , Thyroid Neoplasms , Autoantibodies , Female , Humans , Lymphatic Metastasis , Middle Aged , Neoplasm Staging , Thyroid Neoplasms/pathology , Thyroid Neoplasms/surgery , Thyrotropin
12.
Diagn Microbiol Infect Dis ; 100(3): 115365, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33865070

ABSTRACT

We present the case of an inpatient with pneumonia and repeatedly negative nasopharyngeal SARS-CoV-2 testing. In such challenging cases, alternative diagnostic options include lower respiratory tract and plasma SARS-CoV-2 RNA testing, of which the latter may be particularly useful where bronchoscopy is deferred due to clinical factors or transmission risk.


Subject(s)
COVID-19/diagnosis , Plasma/virology , SARS-CoV-2/isolation & purification , Adult , COVID-19 Nucleic Acid Testing , Humans , Male , Nasopharynx/virology , RNA, Viral/genetics , Specimen Handling
13.
Clin Chem ; 67(7): 977-986, 2021 07 06.
Article in English | MEDLINE | ID: mdl-33720347

ABSTRACT

BACKGROUND: Laboratory-based methods for SARS-CoV-2 antibody detection vary widely in performance. However, there are limited prospectively-collected data on assay performance, and minimal clinical information to guide interpretation of discrepant results. METHODS: Over a 2-week period, 1080 consecutive plasma samples submitted for clinical SARS-CoV-2 IgG testing were tested in parallel for anti-nucleocapsid IgG (anti-N, Abbott) and anti-spike IgG (anti-S1, EUROIMMUN). Chart review was conducted for samples testing positive or borderline on either assay, and for an age/sex-matched cohort of samples negative by both assays. CDC surveillance case definitions were used to determine clinical sensitivity/specificity and conduct receiver operating characteristics curve analysis. RESULTS: There were 52 samples positive by both methods, 2 positive for anti-N only, 34 positive for anti-S1 only, and 27 borderline for anti-S1. Of the 34 individuals positive for anti-S1 alone, 8 (24%) had confirmed COVID-19. No anti-S1 borderline cases were positive for anti-N or had confirmed/probable COVID-19. The anti-N assay was less sensitive (84.2% [95% CI 72.1-92.5%] vs 94.7% [95% CI 85.4-98.9%]) but more specific (99.2% [95% CI 95.5-100%] vs 86.9% [95% CI 79.6-92.3%]) than anti-S1. Abbott anti-N sensitivity could be improved to 96.5% with minimal effect on specificity if the index threshold was lowered from 1.4 to 0.6. CONCLUSION: Real-world concordance between different serologic assays may be lower than previously described in retrospective studies. These findings have implications for the interpretation of SARS-CoV-2 IgG results, especially with the advent of spike antigen-targeted vaccination, as a subset of patients with true infection are anti-N negative and anti-S1 positive.


Subject(s)
Antibodies, Viral/blood , COVID-19/diagnosis , Immunoglobulin G/blood , Nucleocapsid/immunology , SARS-CoV-2/metabolism , Spike Glycoprotein, Coronavirus/immunology , Adult , Area Under Curve , COVID-19/virology , Case-Control Studies , Enzyme-Linked Immunosorbent Assay , Female , Humans , Male , Middle Aged , ROC Curve , Reagent Kits, Diagnostic , Retrospective Studies , SARS-CoV-2/isolation & purification
14.
Emerg Infect Dis ; 27(1)2021 Jan.
Article in English | MEDLINE | ID: mdl-33256889

ABSTRACT

Large-scale, 1-time testing of >12,000 asymptomatic healthcare personnel in California, USA, during April-June 2020 showed that prevalence of severe acute respiratory syndrome coronavirus 2 was low (<1%). Testing might identify asymptomatic and presymptomatic persons, including some with high viral burden, enabling prompt implementation of measures to limit nosocomial spread.


Subject(s)
Asymptomatic Infections , COVID-19/diagnosis , Health Personnel , SARS-CoV-2 , Adult , COVID-19 Testing , Female , Humans , Male , Middle Aged , Prevalence
15.
Clin Chim Acta ; 510: 687-690, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32910980

ABSTRACT

BACKGROUND: We report our findings of test performance especially specificity of a fully automated Abbott Architect anti-SARS-CoV-2 CMIA IgG and Euroimmun anti-SARS-CoV-2 ELISA IgA/IgG in human plasma. METHODS: We used positive cohort of 97 samples from Covid-19 patients or healthcare workers, collected at late time points from symptom onsets. We also included another cohort of 215 samples as negative controls, 78 of which had positive serology test results of other infectious diseases or autoimmunity. Assay specificity was assessed by using a total of 847 anonymized samples which were collected before the Covid-19 pandemic from local patient populations seeking clinical care for rheumatoid diseases, thyroid cancer, and therapeutic drug monitoring. RESULTS: Abbott IgG, Euroimmun IgG/IgA had high precision, demonstrated by both intra- and inter-day CVs of <2%. There was no Abbott or Euroimmun IgG assay cross reactivity in the 78 samples with positive serology of non-SARS-CoV-2 infectious diseases and positive autoimmune antibodies. The Abbott IgG has specificity of 99.6%, while Euroimmun IgG and IgA were as high as 91.5% and 71.5%, respectively. CONCLUSIONS: Our evaluation confirmed high specificity of the Abbott IgG assay, while it was lower for Euroimmun IgG. Euroimmun IgA has suboptimal specificity which may limit its clinical use. Assay sensitivity was high for both Abbott and Euroimmun IgG assays.


Subject(s)
Betacoronavirus/immunology , Enzyme-Linked Immunosorbent Assay/methods , Immunoglobulin A/blood , Immunoglobulin G/blood , Luminescent Measurements , Humans , Immunoglobulin A/immunology , Immunoglobulin G/immunology , Limit of Detection , SARS-CoV-2
16.
Endocrine ; 67(1): 190-197, 2020 01.
Article in English | MEDLINE | ID: mdl-31535345

ABSTRACT

PURPOSE: Serum cortisol measurements after ACTH stimulation are currently used to evaluate for adrenal insufficiency in children. We aim to determine if salivary cortisol measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS) can confirm or replace serum cortisol during high dose ACTH stimulation test to improve test compliance and interpretation. We also aim to gain preliminary understanding of normal ranges of salivary cortisol in normal children at am, bedtime, and midnight. METHODS: Children aged 6-17 years meeting study criteria and tested for adrenal insufficiency were recruited to concomitantly collect saliva and serum samples during high dose ACTH stimulation test. Normal children aged 3-18 years were recruited to collect morning, bedtime, and midnight saliva samples. Salivary cortisol was measured using LC-MS/MS while serum cortisol was determined by an immunoassay. RESULTS: Salivary cortisol in normal children were higher at am and lower at bedtime and midnight (p value <0.0002 and <0.007, respectively). The midnight and bedtime levels were not sufficiently different (p value 0.36). Salivary cortisol during ACTH stimulation test positively and closely correlated with serum cortisol with 100% specificity and sensitivity when 18 µg/dL for serum and 500 ng/dL for salivary cortisol were used as cutoff values respectively for adrenal sufficiency. CONCLUSIONS: Measurement of salivary cortisol by LC-MS/MS is less invasive, more convenient and better time controlled in busy pediatric clinic, therefore is better suited for young children to be used during high dose ACTH stimulation test to evaluate for adrenal insufficiency and to assist interpretation of test results by serum cortisol.


Subject(s)
Adrenal Insufficiency , Hydrocortisone , Adolescent , Adrenal Insufficiency/diagnosis , Adrenocorticotropic Hormone , Child , Child, Preschool , Chromatography, Liquid , Humans , Saliva , Tandem Mass Spectrometry
17.
Sci Rep ; 9(1): 15615, 2019 10 30.
Article in English | MEDLINE | ID: mdl-31666635

ABSTRACT

Hepatitis B virus (HBV) infection has a global reach with high prevalence in resource-limited areas like China and Africa. HBV patients in these areas have limited access to the currently used, costly HBV assays, which are performed in centralized clinical laboratories using single-plexed assays with bulky and expensive instruments. We aim to overcome these limitations by developing a simple and affordable HBV diagnostic platform to allow for timelier diagnosis and intervention of HBV infection. Using giant magnetoresistive (GMR) biosensor chips, we developed an automated and multiplexed quantitative platform for the measurement of a panel of HBV serology markers, including HBV "e" antigen (HBeAg), HBV surface antigen (HBsAg), and the antibody against HBsAg (anti-HBs). Our assay platform was able to detect each HBV marker with high specificity and sensitivity (with three orders of magnitude in dynamic range for each marker). Blinded analysis of HBV patient sera showed excellent correlation between our multiplexed quantitative HBsAg results and the qualitative results obtained using FDA-approved immunoassays, as well as those obtained using quantitative, single-plexed, enzyme-linked immunosorbent assays (ELISAs). The portable, automated, multiplexed, quantitative HBV serology assay platform we designed shows great promise as a more accessible alternative for HBV screening, diagnosis, and treatment monitoring.


Subject(s)
Biosensing Techniques/instrumentation , Hepatitis B/diagnosis , Point-of-Care Systems , Automation , Hepatitis B/transmission , Humans
18.
J Appl Lab Med ; 4(3): 383-390, 2019 11.
Article in English | MEDLINE | ID: mdl-31659075

ABSTRACT

BACKGROUND: The quantification of hepatitis B (HBV) DNA in serum is critical to identify patients requiring antiviral therapy and to monitor the response to treatment. METHOD: This study describes the evaluation of the Aptima HBV Quant Dx assay (Aptima HBV) performed on the automated Panther system. RESULTS: Aptima HBV was linear from 1.70 to 7.70 log10 IU/mL with a commercial reference panel, as well as clinical specimens representing genotypes B and C, and total imprecision, as measured by the percentage coefficient of variation (%CV) at 2.0 log10 IU/mL was <10%. The specificity of Aptima HBV was 94.7% (126/133) and 96.6% (84/87) for serum specimens from individuals without HBV exposure and individuals with resolved HBV infection, respectively. The qualitative agreement and quantitative accuracy of Aptima HBV was compared to the COBAS AmpliPrep/COBAS TaqMan HBV Test v2.0 (CAP/CTM). Overall agreement was 90.8% (187/206) with a κ statistic of 0.708 (standard error, 0.063; 95% CI, 0.585-0.831). Passing-Bablok regression revealed a regression line of y = 0.953x + 0.075 (95% CI of the slope, 0.883-1.011; intercept, -0.100 to 0.299), and Bland-Altman analysis (Aptima - CAP/CTM) showed a slight negative bias (-0.054 log10 IU/mL, and 95% limits of agreement of -1.093 to 0.984). CONCLUSIONS: The Aptima HBV test affords a suitable alternative to CAP/CTM for serum virus load testing and provides a key component of the diagnostic algorithm for the global eradication of viral hepatitis.


Subject(s)
DNA, Viral , Hepatitis B virus/genetics , Hepatitis B/diagnosis , Hepatitis B/virology , Real-Time Polymerase Chain Reaction/methods , Viral Load , Antiviral Agents/therapeutic use , Hepatitis B/drug therapy , Humans , Real-Time Polymerase Chain Reaction/standards , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
19.
Steroids ; 146: 65-69, 2019 06.
Article in English | MEDLINE | ID: mdl-30951757

ABSTRACT

BACKGROUND: 24 h urinary free cortisol measurement is a clinically important first-line screening test for Cushing's syndrome (CS). Tandem mass spectrometry (LC-MS/MS) assays have superior sensitivity and specificity compared to immunoassays. Our goal was to improve and validate a LC-MS/MS method to measure urinary free cortisol in both adult and pediatric patients and to characterize its clinical diagnostic performance of CS by chart review. METHODS: We improved a LC-MS/MS method previously reported for urinary free cortisol to be able to measure urinary and salivary cortisol in the same batch for increased efficiency. The sample preparation was by liquid-liquid extraction using dichloromethane followed by stepwise washing with acidic, basic and neutral solutions. The assay's analytical performance was characterized, and a retrospective patient chart review was conducted to evaluate the assay's clinical performance in diagnosing CS. RESULTS: The LC-MS/MS assay demonstrated enhanced sensitivity and was linear within an analytical measurement range of 10-10,000 ng/dL. Assay accuracy was satisfactory as determined by spike and recovery studies and highly correlated with a reference LC-MS/MS method. The assay's clinical diagnostic sensitivity and specificity in detecting CS was 96% and 91%, respectively, when compared to a urinary cortisol excretion of at least 50 µg/24 h. CONCLUSIONS: The improved LC-MS/MS method is both sensitive and specific with enhanced analytical performance and clinical diagnostic utility to screen for CS. The clinical diagnostic sensitivity and specificity were superior based on retrospective patient chart review.


Subject(s)
Hydrocortisone/urine , Limit of Detection , Tandem Mass Spectrometry , Urinalysis/methods , Adolescent , Adult , Aged , Aged, 80 and over , Child , Cushing Syndrome/urine , Female , Humans , Linear Models , Male , Middle Aged , ROC Curve , Retrospective Studies , Time Factors , Young Adult
20.
J Pediatr Endocrinol Metab ; 32(3): 305-310, 2019 Mar 26.
Article in English | MEDLINE | ID: mdl-30730839

ABSTRACT

Background Neonatal severe hyperparathyroidism (NSHPT) is commonly treated with either parathyroidectomy or pharmacologic agents with varying efficacy and numerous side effects. Reports of using cinacalcet for NSHPT have increased, however, the effective dose for pediatric patients from the onset of symptoms through infancy has not been established. Case presentation We describe the clinical course of a newborn with a de novo R185Q mutation in the calcium-sensing receptor (CASR) gene, causing NSHPT. The infant received cinacalcet from the first days of life until 1 year of age. Conclusions Cinacalcet therapy effectively controlled the patient's serum calcium, phosphorus, and parathyroid hormone (PTH) levels without side effects.


Subject(s)
Calcium-Regulating Hormones and Agents/therapeutic use , Cinacalcet/therapeutic use , Hyperparathyroidism/drug therapy , Mutation , Receptors, Calcium-Sensing/genetics , Humans , Hyperparathyroidism/genetics , Infant , Infant, Newborn , Male , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...